MAURY USCG vessel records Sign in
← All vessels

PUDU

PUDU is a 1989 freight ship. The Coast Guard has recorded 36 inspections since 1990, most recently in March 2008, along with 38 deficiencies and 4 operational controls.

Records from 1990 to 2008. Most recent: inspection, 1 March 2008.

Built
1989
Last inspected
1 March 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8701492 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
337856
Flag
LIBERIA
—
Maury page id
psix-337856

Inspections, by type

…with no type recorded26
Years with a record 14 calendar years (1990–2008)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it12516 - Convention (Subpart B), Net Ton
21399 - Convention (Subpart B), Gross Ton
33230 - Dead Weight, Ton
42210 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

1 March 2008 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3155545
28 February 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3157473
4 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3109613
26 November 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3104423
26 November 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3104652
21 November 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3105033
26 June 2007 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · Deficiency Check · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2968461
22 June 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2974216
4 January 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2560946
1 January 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2559040
9 September 2004 ISPS II Exam · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2191675
7 January 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1977263
6 January 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1976508
18 July 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1648313
4 March 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1488832
11 February 2001 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 287058
31 October 2000 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 283673
30 July 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 280947
22 February 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274877
27 July 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 430978
25 January 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 424718
3 November 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 422012
30 March 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 414258
5 August 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 406434
29 January 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 533339
22 November 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 397842
2 April 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 389581
23 January 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387079
13 October 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 371394
24 September 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 519257
4 September 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 370256
18 August 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 465203
9 February 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348716
23 August 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 338792
23 May 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 337210
25 January 1990 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 490253

Deficiency record · 38

Navigation › Collision/Grounding Avoidance › Radar
Issued 28 February 2008 Resolved
Received notification that the S-band radar onboard was malfunctioning during M/V Pudu's voyage from Mexico. LOD granted to entry in to the San Francisco Bay. Must be repaired by a certified technician
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2008
Resolution: Received a tech report stating the satisfactory repairs done to the radar.
Engineering › Fuel Oil Service System › Piping
Issued 26 November 2007 Resolved
High pressure fuel lines for propulsion diesel found unsecured allowing fuel leakage to escape causing potential fire hazard. Repair within 14days to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 1 March 2008
Resolution: Received Class report. Leaks as per note has been attended to; at time of inspection no leaks visible.
Construction/Loadline › Structures › Ventilators
Issued 26 November 2007 Resolved
All cargo hold ventilators were found poorly maintained; 4 of 6 were found frozen closed with closing/opening gear inoperative. Repair within 30 days to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 1 March 2008
Resolution: Received Class report: Vents to cargo holds has all been attended to; at time of inspection all cargo vents operating satisfactory.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 June 2007 Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation act of 2004.
Action required: 705 - Other - as specified
Resolved 26 November 2007
Resolution: [name withheld] reviewed and found everything to be in order.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 June 2007 Resolved
There are two extra sets of valves and hoses attached to the oily water separator that allow oily water to be pumped into the engine room space. The vessel does not have any documentation that states the nature of the extra valves and hoses and it must provide documentation that authorizes this arrangement or remove the valves and hoses.
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 26 November 2007
Resolution: Class report states extra equipment has been removed
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 June 2007 Resolved
During the course of the engine room inspection, the PSCO noted inconsistencies between the piping diagram for the oily water separator and the actual piping connected to the system. The vessel must provide documentation that verifies that the currant piping arrangement is authorized.
Action required: 705 - Other - as specified
Due 26 July 2007
Resolved 26 November 2007
Resolution: Class survey statement says that a new piping diagram has been submitted to the owners. Also an interim IOPP has been issued.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 January 2006 Resolved
Neither the audible nor the visible alarm for the OWS were operable. Marpol I/16(2).
Due 2 January 2006
Resolved 2 January 2006
Resolution: Both alarms were fixed while inspectors were on board.
Deck/Cargo › Ballast › Piping
Issued 1 January 2006 Resolved
Overboard ballast line for the port ballast pump has a soft patch. SOLAS II-1/21.1.4
Due 2 February 2006
Resolved 26 June 2007
Resolution: The Vessel has satisfied this requirement.
Operations/Management › Pollution › Control of Garbage
Issued 1 January 2006 Resolved
According to vessel's garbage management plan, plastic may be incinerated and Thrown overboard (Chapter 1.4 of the plan). this is a violation of Marpol V/3(1)(a)
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 26 June 2007
Resolution: The Vessel has satisfied this requirement.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 1 January 2006 Resolved
Ballast Water Report from was filled out incorrectly. The vessel was not de-ballasting, therefore section 4 should not have been filled out. The Ballast Water Handling log was filled out incorrectly. All logs required by the vessel's BWM plan should be kept readily available for review, including Sediment Removal and Training logs. 33CFR151.2045
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 26 June 2007
Resolution: The Vessel has satisfied this requirement.
Documentation › Logs/Records › Oil Record Book
Issued 1 January 2006 Resolved
The oil record book is missing codes for several entries. Marpol I/20(4).
Due 2 January 2006
Resolved 2 January 2006
Resolution: Chief Engineer was educated by inspectors on proper record keeping.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 January 2006 Resolved
NOAA charts 18661 and 18663 are not currently corrected. Vessel was not supplied with local notice to mariners. SOLAS 74 V/20.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2006
Resolution: Received fax from agent.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 1 January 2006 Resolved
Several lifejackets onboard were not adequate due to torn seams. There are 19 crew members and 49 lifejackets. Ensure all crew members' lifejackets are not torn. SOLAS 74 III/22(c)(i).
Due 9 January 2006
Resolved 26 June 2007
Resolution: The Vessel has satisfied this requirement.
Navigation › Collision/Grounding Avoidance
Issued 7 January 2004 Resolved
VESSELS 3CM SECONDARY RADAR IS INOPERATIVE. VESSEL IS TO REPAIR RADAR AND SUBMIT TECH REPORT PRIOR TO DEPARTURE. AS REQUIRED BY 33 CFR 164.35(a) LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2004
Resolution: Recieved tech report form [name withheld] attesting to repairs of 3CM Radar.
Operations/Management › Vessel Traffic Service
Issued 7 January 2004 Resolved
VESSEL MADE INBOUND TRANSIT TO COTP PHILADELPHIA WITHOUT REQUESTING LETTER OF DEVIATION FOR 3CM SECONDARY RADAR. VESSELS MASTER WAS EDUCATED ON THE NECESSARY PROCEDURES. AS REQUIRED BY 33 CFR 164.53. LEGACY COMPONENT DESC: Reporting Requirements
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2004
Resolution: MASTER WAS INSTRUCTED ON THE PROPER REPORTING REQUIREMENTS.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 7 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 February 2004
Resolved 9 September 2004
Resolution: Inspected by USCG Boarding team and confirmed repair.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 January 2004 Resolved
VESSEL HAS SOFT PATCH ON SEA WATER SUPPLY LINE LEADING TO STEAM CONDENSING UNIT IN THE E/R. VESSEL IS TO MAKE PERMANENT REPAIRS AND HAVE COAST GUARD ATTEST TO REPAIR. AS REQUIRED BY SOLAS 74/78 CH.II-1/REG.26.1. TO BE CORRECTED PRIOR TO NEXT US PORT AFETR SAILING FOREIGN OR W/IN 30 DAYS. LEGACY COMPONENT DESC: Piping
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 February 2004
Resolved 9 September 2004
Resolution: Inspected by USCG boarding team and confirmed repair.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 March 2002 Resolved
RAIL IN WAY OF PORT LIFEBOAT WASTED, CROP AND RENEW TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Deck/Cargo
Issued 6 March 2002 Resolved
FRESH WATER WASH LINE RUNNING LENGTH OF MAIN DECK WASTED. RENEW LINE TO THE SATISFACTION CLASS BEFORE RETURNING TO U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: FRESH WATER LINE
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Electrical › Electric Supply System (service)
Issued 6 March 2002 Resolved
AMPERAGE GUAGE ON CONTROL PANEL FOR PORTSIDE DECK WINCHES INOPERATIVE. REPAIR OR REPLACE TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: AMPERAGE GUAGE ON PANEL
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Deck/Cargo › Ballast
Issued 6 March 2002 Resolved
#1 AND #2 BALLAST PUMP GUARDS MISSING. PLACE GUARDS IN FRONT OF ROTATING SHAFT, TO THE SATISFACTION OF CLASS BEFORE RETURNING TO U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Pumps
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Engineering › Steam System (auxiliary)
Issued 6 March 2002 Resolved
STEAM VALVE TO MANIFOLD IN WAY OF #5A FUEL OIL TANK LEAKS EXCESSIVELY. REPAIR TO THE SATISFACTION OF CLASS BEFORE RETURNING TO U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Accommodation/Occupational Safety › Ventilation
Issued 6 March 2002 Resolved
MAINTENANCE PUMP IN WAY OF A/C HAS SEVERAL EXPOSED WIRES, REMOVE OR REPAIR TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: AIR CONDITIONING
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Engineering › Steam System (auxiliary)
Issued 6 March 2002 Resolved
FUEL LINE TO AUX. BOILER LEAKING, REPAIR REPLACE CONNECTION TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Deck/Cargo
Issued 4 March 2002 Resolved
MOTOR ON #1 GRAB LEAKING HYDRAULIC FLUID, REPAIR OR REPLACE TO MAKE LEAK FREE TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: MOTOR ON #1 GRAB
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 4 March 2002 Resolved
REPAIR/ REPLACE LIGHT BULBS MISSING FROM OILY WATER SEPARATOR CONTROL PANEL TO THE SATISFACTION OF CLASS BEFORE RETUNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Engineering › Steam System (auxiliary)
Issued 4 March 2002 Resolved
#2 CIRCULATING PUMP FOR AUX. BOILER INOPERATIVE, REPAIR OR REPLACE PUMP TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT06APR02 LEGACY COMPONENT DESC: PUMP
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 4 March 2002 Resolved
AFT ENTRANCE DOOR CLOSING BRACKET INOPERATIVE, REPAIR OR REPLACE BRACKET TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Open Deck Space
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Engineering
Issued 4 March 2002 Resolved
OPEN ENDED PIPES COMING FROM TANK UNDER DRIVE SHAFT, BLANK PIPES OR MAKE CONTINUOUS TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: OPEN ENDED PIPES
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 4 March 2002 Resolved
SLUDGE TANK PUMP INOPERATIVE, REPAIR OR REPLACE TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: SLUDGE TANK PUMP
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 20 July 2002
Resolution: Item corrected.
Documentation
Issued 3 November 1998 Resolved
Provide written policy on vessel familiarization for new crewmembers per STCW 95, REG. VI/1. Provide prior to next U.S. Port after sailing foreign.
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Lifesaving
Issued 2 April 1996 Resolved
REPLACE ALL FOOD RATIONS IN PORT & STARBORD LIFE BOAT, WITHIN 30 DAYS_x001C_ OF BOARDING DATE. FOOD RATIONS HAVE LOST THEIR VACCUUM SEAL.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Accommodation/Occupational Safety
Issued 23 January 1996 Resolved
Make permanent repairs to the temporarily patched area on the aft side of the MSD tank, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Engineering
Issued 23 January 1996 Resolved
Make permanent repairs to the leaking weld on the condensate cooler S/W inlet pipe outboard of cooler valve, prior to the next U.S. port call._x001C_ _x001C_ Soals Ch II-1, Reg 26
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Engineering
Issued 23 January 1996 Resolved
Repair the AE emergency start filter inlet gauge (no reading achieved due to missing needle), prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Engineering
Issued 23 January 1996 Resolved
Provide proper mechanical closures (threaded) for fuel/lube oil containment, prior to the next U.S. port call._x001C_ _x001C_ 33 CFR 155
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Engineering
Issued 23 January 1996 Resolved
Identify the source of the constant small leak from the boiler and correct to eliminate the dripping of water to the lower decks, prior to the next U.S. port call._x001C_ Solas Ch II-1, Reg 26
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Engineering
Issued 23 January 1996 Resolved
Make permanent repairs to the metal banded rubber patch on the leaking S/W recirculation pipe for the M/E cooler, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.