Records from 1990 to 2008. Most recent: inspection, 1 March 2008.
- Built
- 1989
- Last inspected
- 1 March 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8701492 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8LY9
337856
Flag
LIBERIA
—
Maury page id
psix-337856
Inspections, by type
…with no type recorded26
Years with a record
14 calendar years (1990–2008)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it12516 - Convention (Subpart B), Net Ton
21399 - Convention (Subpart B), Gross Ton
33230 - Dead Weight, Ton
42210 - Displacement, Ton
21399 - Convention (Subpart B), Gross Ton
33230 - Dead Weight, Ton
42210 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
1 March 2008
Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3155545
28 February 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3157473
4 December 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3109613
26 November 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3104423
26 November 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3104652
21 November 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3105033
26 June 2007
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · Deficiency Check · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2968461
22 June 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2974216
4 January 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2560946
1 January 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2559040
9 September 2004
ISPS II Exam · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2191675
7 January 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1977263
6 January 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1976508
18 July 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1648313
4 March 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1488832
11 February 2001
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 287058
31 October 2000
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 283673
30 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 280947
22 February 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274877
27 July 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 430978
25 January 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 424718
3 November 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 422012
30 March 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 414258
5 August 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 406434
29 January 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 533339
22 November 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 397842
2 April 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 389581
23 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387079
13 October 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 371394
24 September 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 519257
4 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 370256
18 August 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 465203
9 February 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348716
23 August 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 338792
23 May 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 337210
25 January 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 490253
Deficiency record · 38
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 February 2008
Resolved
Received notification that the S-band radar onboard was malfunctioning during M/V Pudu's voyage from Mexico. LOD granted to entry in to the San Francisco Bay. Must be repaired by a certified technician
Engineering › Fuel Oil Service System › Piping
Issued 26 November 2007
Resolved
High pressure fuel lines for propulsion diesel found unsecured allowing fuel leakage to escape causing potential fire hazard. Repair within 14days to the satisfaction of class.
Construction/Loadline › Structures › Ventilators
Issued 26 November 2007
Resolved
All cargo hold ventilators were found poorly maintained; 4 of 6 were found frozen closed with closing/opening gear inoperative. Repair within 30 days to the satisfaction of class.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 June 2007
Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation act of 2004.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 June 2007
Resolved
There are two extra sets of valves and hoses attached to the oily water separator that allow oily water to be pumped into the engine room space. The vessel does not have any documentation that states the nature of the extra valves and hoses and it must provide documentation that authorizes this arrangement or remove the valves and hoses.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 June 2007
Resolved
During the course of the engine room inspection, the PSCO noted inconsistencies between the piping diagram for the oily water separator and the actual piping connected to the system. The vessel must provide documentation that verifies that the currant piping arrangement is authorized.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 January 2006
Resolved
Neither the audible nor the visible alarm for the OWS were operable. Marpol I/16(2).
Deck/Cargo › Ballast › Piping
Issued 1 January 2006
Resolved
Overboard ballast line for the port ballast pump has a soft patch. SOLAS II-1/21.1.4
Operations/Management › Pollution › Control of Garbage
Issued 1 January 2006
Resolved
According to vessel's garbage management plan, plastic may be incinerated and Thrown overboard (Chapter 1.4 of the plan). this is a violation of Marpol V/3(1)(a)
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 1 January 2006
Resolved
Ballast Water Report from was filled out incorrectly. The vessel was not de-ballasting, therefore section 4 should not have been filled out. The Ballast Water Handling log was filled out incorrectly. All logs required by the vessel's BWM plan should be kept readily available for review, including Sediment Removal and Training logs. 33CFR151.2045
Documentation › Logs/Records › Oil Record Book
Issued 1 January 2006
Resolved
The oil record book is missing codes for several entries. Marpol I/20(4).
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 January 2006
Resolved
NOAA charts 18661 and 18663 are not currently corrected. Vessel was not supplied with local notice to mariners. SOLAS 74 V/20.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 1 January 2006
Resolved
Several lifejackets onboard were not adequate due to torn seams. There are 19 crew members and 49 lifejackets. Ensure all crew members' lifejackets are not torn. SOLAS 74 III/22(c)(i).
Navigation › Collision/Grounding Avoidance
Issued 7 January 2004
Resolved
VESSELS 3CM SECONDARY RADAR IS INOPERATIVE. VESSEL IS TO REPAIR RADAR AND SUBMIT TECH REPORT PRIOR TO DEPARTURE. AS REQUIRED BY 33 CFR 164.35(a) LEGACY COMPONENT DESC: Radar
Operations/Management › Vessel Traffic Service
Issued 7 January 2004
Resolved
VESSEL MADE INBOUND TRANSIT TO COTP PHILADELPHIA WITHOUT REQUESTING LETTER OF DEVIATION FOR 3CM SECONDARY RADAR. VESSELS MASTER WAS EDUCATED ON THE NECESSARY PROCEDURES. AS REQUIRED BY 33 CFR 164.53. LEGACY COMPONENT DESC: Reporting Requirements
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 7 January 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 January 2004
Resolved
VESSEL HAS SOFT PATCH ON SEA WATER SUPPLY LINE LEADING TO STEAM CONDENSING UNIT IN THE E/R. VESSEL IS TO MAKE PERMANENT REPAIRS AND HAVE COAST GUARD ATTEST TO REPAIR. AS REQUIRED BY SOLAS 74/78 CH.II-1/REG.26.1. TO BE CORRECTED PRIOR TO NEXT US PORT AFETR SAILING FOREIGN OR W/IN 30 DAYS. LEGACY COMPONENT DESC: Piping
Accommodation/Occupational Safety › Occupational Safety
Issued 6 March 2002
Resolved
RAIL IN WAY OF PORT LIFEBOAT WASTED, CROP AND RENEW TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Deck Rail
Deck/Cargo
Issued 6 March 2002
Resolved
FRESH WATER WASH LINE RUNNING LENGTH OF MAIN DECK WASTED. RENEW LINE TO THE SATISFACTION CLASS BEFORE RETURNING TO U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: FRESH WATER LINE
Electrical › Electric Supply System (service)
Issued 6 March 2002
Resolved
AMPERAGE GUAGE ON CONTROL PANEL FOR PORTSIDE DECK WINCHES INOPERATIVE. REPAIR OR REPLACE TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: AMPERAGE GUAGE ON PANEL
Deck/Cargo › Ballast
Issued 6 March 2002
Resolved
#1 AND #2 BALLAST PUMP GUARDS MISSING. PLACE GUARDS IN FRONT OF ROTATING SHAFT, TO THE SATISFACTION OF CLASS BEFORE RETURNING TO U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Pumps
Engineering › Steam System (auxiliary)
Issued 6 March 2002
Resolved
STEAM VALVE TO MANIFOLD IN WAY OF #5A FUEL OIL TANK LEAKS EXCESSIVELY. REPAIR TO THE SATISFACTION OF CLASS BEFORE RETURNING TO U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Valve
Accommodation/Occupational Safety › Ventilation
Issued 6 March 2002
Resolved
MAINTENANCE PUMP IN WAY OF A/C HAS SEVERAL EXPOSED WIRES, REMOVE OR REPAIR TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: AIR CONDITIONING
Engineering › Steam System (auxiliary)
Issued 6 March 2002
Resolved
FUEL LINE TO AUX. BOILER LEAKING, REPAIR REPLACE CONNECTION TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: Piping
Deck/Cargo
Issued 4 March 2002
Resolved
MOTOR ON #1 GRAB LEAKING HYDRAULIC FLUID, REPAIR OR REPLACE TO MAKE LEAK FREE TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: MOTOR ON #1 GRAB
Pollution Prevention/Response › Prevention Equipment
Issued 4 March 2002
Resolved
REPAIR/ REPLACE LIGHT BULBS MISSING FROM OILY WATER SEPARATOR CONTROL PANEL TO THE SATISFACTION OF CLASS BEFORE RETUNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Engineering › Steam System (auxiliary)
Issued 4 March 2002
Resolved
#2 CIRCULATING PUMP FOR AUX. BOILER INOPERATIVE, REPAIR OR REPLACE PUMP TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT06APR02 LEGACY COMPONENT DESC: PUMP
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 4 March 2002
Resolved
AFT ENTRANCE DOOR CLOSING BRACKET INOPERATIVE, REPAIR OR REPLACE BRACKET TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02. LEGACY COMPONENT DESC: Open Deck Space
Engineering
Issued 4 March 2002
Resolved
OPEN ENDED PIPES COMING FROM TANK UNDER DRIVE SHAFT, BLANK PIPES OR MAKE CONTINUOUS TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: OPEN ENDED PIPES
Pollution Prevention/Response › Prevention Equipment
Issued 4 March 2002
Resolved
SLUDGE TANK PUMP INOPERATIVE, REPAIR OR REPLACE TO THE SATISFACTION OF CLASS BEFORE RETURNING TO THE U.S. AFTER GOING FOREIGN. NLT 06APR02 LEGACY COMPONENT DESC: SLUDGE TANK PUMP
Documentation
Issued 3 November 1998
Resolved
Provide written policy on vessel familiarization for new crewmembers per STCW 95, REG. VI/1. Provide prior to next U.S. Port after sailing foreign.
Lifesaving
Issued 2 April 1996
Resolved
REPLACE ALL FOOD RATIONS IN PORT & STARBORD LIFE BOAT, WITHIN 30 DAYS_x001C_ OF BOARDING DATE. FOOD RATIONS HAVE LOST THEIR VACCUUM SEAL.
Accommodation/Occupational Safety
Issued 23 January 1996
Resolved
Make permanent repairs to the temporarily patched area on the aft side of the MSD tank, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26
Engineering
Issued 23 January 1996
Resolved
Make permanent repairs to the leaking weld on the condensate cooler S/W inlet pipe outboard of cooler valve, prior to the next U.S. port call._x001C_ _x001C_ Soals Ch II-1, Reg 26
Engineering
Issued 23 January 1996
Resolved
Repair the AE emergency start filter inlet gauge (no reading achieved due to missing needle), prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26
Engineering
Issued 23 January 1996
Resolved
Provide proper mechanical closures (threaded) for fuel/lube oil containment, prior to the next U.S. port call._x001C_ _x001C_ 33 CFR 155
Engineering
Issued 23 January 1996
Resolved
Identify the source of the constant small leak from the boiler and correct to eliminate the dripping of water to the lower decks, prior to the next U.S. port call._x001C_ Solas Ch II-1, Reg 26
Engineering
Issued 23 January 1996
Resolved
Make permanent repairs to the metal banded rubber patch on the leaking S/W recirculation pipe for the M/E cooler, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26