Records from 2016 to 2026. Most recent: inspection, 10 June 2026.
Inspection history · 19
10 June 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8400957
16 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8235270
14 November 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8029731
17 September 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004223
21 June 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7956767
7 February 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861291
19 October 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7580363
13 October 2022
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7576826
3 October 2022
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7577153
8 June 2022
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472330
6 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7376267
1 February 2021
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7134652
20 August 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7038196
15 November 2019
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6851983
16 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6608483
23 October 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6567098
1 February 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6346092
8 February 2017
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6084923
19 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6023750
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis for all crewmembers that occupy a position as required by the vessel's Certificate of Inspection; Master onboard the vessel was not on the covered list of employees for random chemical testing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 October 2022
Resolved 21 October 2022
Resolution: Successful DAPI Audit
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 February 2021
Resolved
Observed missing/deteroiorated heat insulation on engine hatch covers. Replace missing heat insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Observed satisfactory installation of heat insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2021
Resolved
Observed deteriorated grab lines on ring buoy. Replace/repair damaged grab lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Operator installed new ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 November 2019
Resolved
Prove proper operation of the Installed "Fire Boy" system.
46 CFR 181.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2019
Resolved 18 November 2019
Resolution: All required indications and shutdowns were tested satisfactorily for the Fire Boy system.
Fire Fighting › Fire Bucket › Quantity
Issued 9 February 2017
Resolved
Have a minimum of 3 fire buckets onboard (vessel ony had one) 46CFR181.610
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 March 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 February 2017
Resolved
Lsbel the number of lifejackets kept onboard. 46CFR180.78
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 March 2017
Construction/Loadline › Hull › Side Shell
Issued 19 October 2016
Resolved
Quarter sized hole located on portside quarter. Grind back to solid material utilizing adequate scarf and renew to original lay-up schedule
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 31 October 2016
Resolution: Hole in hull properly repaired.
Construction/Loadline › Hull › Side Shell
Issued 19 October 2016
Resolved
1/2 in crack located on starboard bow in way of upper fender mounting bracket. Grind back to good material utilizing adequate scarf and renew to original lay-up schedule.
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 31 October 2016
Construction/Loadline › Hull › Hull Plating
Issued 19 October 2016
Resolved
Crack located on shaft tube. Provide repair proposal.
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 31 October 2016