MAURY USCG vessel records
← All vessels

J.D. HANSON

J.D. HANSON is a 1987 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 9 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 10 June 2026.

Built
1987
Last inspected
10 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

338176
Flag
UNITED STATES
Maury page id
psix-338176

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

10 June 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8400957
16 September 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8235270
14 November 2024 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8029731
17 September 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004223
21 June 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7956767
7 February 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861291
19 October 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7580363
13 October 2022 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7576826
3 October 2022 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7577153
8 June 2022 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472330
6 January 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7376267
1 February 2021 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7134652
20 August 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7038196
15 November 2019 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6851983
16 January 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6608483
23 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6567098
1 February 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6346092
8 February 2017 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6084923
19 October 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6023750

Deficiency record · 9

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2022 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis for all crewmembers that occupy a position as required by the vessel's Certificate of Inspection; Master onboard the vessel was not on the covered list of employees for random chemical testing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 October 2022
Resolved 21 October 2022
Resolution: Successful DAPI Audit
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 February 2021 Resolved
Observed missing/deteroiorated heat insulation on engine hatch covers. Replace missing heat insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Observed satisfactory installation of heat insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2021 Resolved
Observed deteriorated grab lines on ring buoy. Replace/repair damaged grab lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Operator installed new ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 November 2019 Resolved
Prove proper operation of the Installed "Fire Boy" system. 46 CFR 181.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2019
Resolved 18 November 2019
Resolution: All required indications and shutdowns were tested satisfactorily for the Fire Boy system.
Fire Fighting › Fire Bucket › Quantity
Issued 9 February 2017 Resolved
Have a minimum of 3 fire buckets onboard (vessel ony had one) 46CFR181.610
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 March 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 February 2017 Resolved
Lsbel the number of lifejackets kept onboard. 46CFR180.78
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 March 2017
Construction/Loadline › Hull › Side Shell
Issued 19 October 2016 Resolved
Quarter sized hole located on portside quarter. Grind back to solid material utilizing adequate scarf and renew to original lay-up schedule
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 31 October 2016
Resolution: Hole in hull properly repaired.
Construction/Loadline › Hull › Side Shell
Issued 19 October 2016 Resolved
1/2 in crack located on starboard bow in way of upper fender mounting bracket. Grind back to good material utilizing adequate scarf and renew to original lay-up schedule.
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 31 October 2016
Construction/Loadline › Hull › Hull Plating
Issued 19 October 2016 Resolved
Crack located on shaft tube. Provide repair proposal.
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 31 October 2016

Ownership record