MAURY USCG vessel records Sign in
← All vessels

BETSY ROSS

BETSY ROSS is a 1944 school ship. The Coast Guard has recorded 48 inspections since 1989, most recently in December 2005, along with 100 deficiencies.

Records from 1989 to 2005. Most recent: inspection, 10 December 2005.

Built
1944
Last inspected
10 December 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

338228
Flag
UNITED STATES
—
Maury page id
psix-338228

Inspections, by type

…with no type recorded4
Years with a record 16 calendar years (1989–2005)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it262 - Regulatory (Subpart C or D), Net Ton
560 - Regulatory (Subpart C or D), Gross Ton
935 - Dead Weight, Ton
465 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 48

10 December 2005 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2549299
14 January 2003 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1730268
13 November 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1701475
2 August 2002 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1633936
30 January 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1482866
30 November 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 772587
7 November 2001 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1075829
1 November 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1075650
27 July 2001 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1466789
20 October 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 823198
8 August 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1432366
17 May 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 818623
14 April 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 817234
2 March 2000 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 817436
3 February 2000 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372887
22 October 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1126870
6 October 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1437620
4 August 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1110867
20 July 1999 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1378745
4 June 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 806175
18 September 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 799402
11 August 1998 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1131182
17 July 1998 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 795270
26 March 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 788593
7 January 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786413
19 November 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1110543
18 July 1997 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402505
25 November 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1363855
12 July 1996 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1380648
14 June 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453138
3 November 1994 Deficiency Check · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389914
20 September 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1180364
11 August 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 118824
28 June 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1335096
6 June 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379983
15 June 1993 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1439417
13 April 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 834757
20 January 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1139912
12 November 1992 Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961055
11 June 1992 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 955848
21 April 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 948305
17 December 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1268099
1 October 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 938079
10 July 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1245279
14 June 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 903062
14 June 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1215249
15 June 1990 Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 917312
23 October 1989 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1226514

Deficiency record · 100

Construction/Loadline › Structures
Issued 13 November 2002 Resolved
Descale tank top of aft peak tank for further visual evaluation. Provide gauging report of tank top thickness and provide a repair proposal based on visual finding & gauging report. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 14 January 2003
Resolution: Vessel no longer in Certificated Service.
Lifesaving › Inflatable Liferafts
Issued 1 November 2001 Resolved
Liferafts need to be placed where they can be moved, during an emergency, to either side in a quickly and unobstructive manner.
Condition: Unknown
Due 5 January 2002
Resolved 22 January 2002
Resolution: Liferafts were relocated to an appropriate location.
Lifesaving
Issued 27 July 2001 Resolved
PROVIDE CERTIFICATION FOR MATERIAL & BREAKING STRENGTH OF WIRE ROPE USED ONLIFE BOAT FALL AS REQUIRED BY 46 CFR 199.153.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
PROVIDE APPROVED RELIEF VALVE WITH LIFTING DEVICE FOR BOTH START AIR RECEIVERS IAW 46 CFR 54.15-10.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
PERFORM UNDERWAY OPERATIONAL TEST OF VESSEL, RESCUE BOAT, AND MAN OVERBOARDDRILL. 46 CFR 167.15-1
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
MAKE #3P & #4S FUEL TANKS AVAILABLE FOR INSPECTION BY GAS FREEING AND PROVIDE ATTENDING MARINE INSPECTOR WITH A VALID MARINE CHEMIST CERTIFICATE.46 CFR 167.15-40
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Lifesaving
Issued 27 July 2001 Resolved
IN THE PRESENCE OF A MARINE INSPECTOR, CONDUCT A 10% OVERLOAD TEST OF THE LIFEBOAT & RESCUE BOAT LAUNCHING APPARTUS IAW 46 CFR 199.45.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
PROVIDE LIFEJACKET LIGHTS FOR EACH IMMERSION SUIT ON BOARD IAW 46 CFR 199.273.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
PROVIDE ALL REQUIRED EQUIPMENT FOR LIFEBOAT AND RESCUE BOAT IAW 46 CFR 199.175.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Navigation
Issued 27 July 2001 Resolved
PROVIDE DECK MARKINGS TO INDICATE PROPER RUDDER ANGLE DURING EMERGENCY STEERING OPERATIONS TO MEET THE INTENT OF 46 CFR 58.25-25.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 8 August 2000 Resolved
PROVIDE OPERATING, MAINTENANCE, EMERGENCY PROCEDURES FOR NEWLY INSTALLED BOILER.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Electrical
Issued 8 August 2000 Resolved
PROVIDE PROPER WATERTIGHT ELECTRICAL CONNECTIONS FOR THROUGHOUT ENGINEROOM ESPECIALLY FOR PORT ENGINE._x001C_
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Fire Fighting
Issued 8 August 2000 Resolved
PROVIDE PROPER REPAIR TO PITTING IN HYDRANT STANDPIPE LOCATED ON BOW.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Electrical
Issued 8 August 2000 Resolved
PROPERLY LABEL ALL EMERGENCY LIGHTING.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Engineering
Issued 3 February 2000 Resolved
Replace both nonmetalic expansion joints in engine room. Both joints are over 10 years in age.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Fire Fighting
Issued 6 October 1999 Resolved
CONDUCT REVIEW OF CO2 FIXED FIRE FIGHTING SYSTEM, INCLUDING PIPING, ACTUATORS, TIME DELAY, AND DISCHARGE ALARM, AND SUBMIT PROPOSED CHANGES TO THE OCMI FOR APPROVAL. CO2 FIXED FIRE FIGHTING SYSTEM SHOULD NOT BE ABLE TO BE DISCHARGED INTO AN OCCUPIED SPACE WITHOUT TIME DELAY OR ALARMS.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 20 July 1999 Resolved
Properly mark general alarm in forward and after crew spaces.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Fire Fighting
Issued 20 July 1999 Resolved
Review fixed fire system instructions and submit for approval by the OCMI.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 20 July 1999 Resolved
Repair forepeak deck hatch where wasted on forward edge or replace hatch.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Engineering
Issued 20 July 1999 Resolved
Provide closing device for vent stack on starboard side of forecastle near bow peak.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 20 July 1999 Resolved
Blank off open breakers in engineroom box light panel LF 105
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 20 July 1999 Resolved
Vessel is restricted to rivers route and lakes bays and sounds only until immersion suits required by 46 CFR 199 are aboard for all crew members.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Electrical
Issued 20 July 1999 Resolved
Properly mark the amps of breakers in light panel LF 106 in forward hold
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Engineering
Issued 20 July 1999 Resolved
Repair as original flex hose to port engine emergency salt water cooling line.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Fire Fighting
Issued 20 July 1999 Resolved
Conduct electrical conductivity test on fire extinguisher at base of ladderin number 1 hold.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 20 July 1999 Resolved
Prove proper operation of bilge system.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 20 July 1999 Resolved
Repair or replace cracked vent fitting on deck on starboard side just aft of forepeak compartment.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Engineering
Issued 20 July 1999 Resolved
Conduct hydro test of boiler and open mounts for inspection.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Construction/Loadline
Issued 20 July 1999 Resolved
Repair lower knife edge on #2 watertight door where metal is wasted.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Navigation
Issued 17 July 1998 Resolved
RE-CALIBRATE MAGNETIC COMPASS OR PROVIDE UP-TO-DATE DEVIATION CARD.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Construction/Loadline
Issued 17 July 1998 Resolved
REPAIR HOLE IN NUMBER 2 CARGO HATCH COAMING AFT SIDE CENTER LINE OF COAMING.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Construction/Loadline
Issued 17 July 1998 Resolved
REPLACE RUBBER GASKET IN WATERTIGHT DOOR NUMBER 1 AND CONDUCT CHALK TEST.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 17 July 1998 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON PORT AND STARBOARD BRIDGE WING RING BUOYS.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Accommodation/Occupational Safety
Issued 17 July 1998 Resolved
MODIFY EGRESS ROUTE THROUGH EMERGENCY ESCAPE LEADING FROM MACHINERY SPACE TO ENSURE AT LEAST 18 INCHES OF CLEARANCE IS AVAILABLE.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Fire Fighting
Issued 17 July 1998 Resolved
DEMONSTRATE PROPER OPERATION OF FIRE DETECTION SYSTEM FOR CARGO HOLDS 1 AND2 AND THE FORWARD PAINT LOCKER.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Electrical
Issued 17 July 1998 Resolved
REPAIR/REPLACE LIGHT FIXTURE BEHIND MAIN SWITCHBOARD IN MACHINERY SPACE.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Electrical
Issued 17 July 1998 Resolved
REMOVE CABLE LOCATED ABOVE AFT END OF NUMBER 1 MAIN DIESEL ENGINE, IN ITS ENTIRETY OR PROPERLY DEADEND.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Electrical
Issued 17 July 1998 Resolved
REMOVE GRAY CABLE PENETRATING PORT SIDE TOP OF MAIN SWITCHBOARD OR PROPERLYINSTALL WITH CORRECT PENETRATION.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Accommodation/Occupational Safety
Issued 17 July 1998 Resolved
REPAIR/REPLACE ESCAPE HATCH LEADING FROM MACHINERY SPACE. DOGS DO NOT PROPERLY LAND ON STRIKER PLATES OR AFFORD A PROPER SEAL.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Construction/Loadline
Issued 19 November 1997 Resolved
CROP AND RENEW THAT PORTION OF BULKHEAD BETWEEN AMMO AND BOSN STORES AT SECOND DECK LEVEL.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Construction/Loadline
Issued 19 November 1997 Resolved
MAKE REPAIRS TO AFT ROSE BOX IN CHAIN LOCKER WHERE WASTED.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Construction/Loadline
Issued 19 November 1997 Resolved
REATTACH LADDER IN HOLD NUMBER 2 WHERE BROKEN.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Electrical
Issued 18 July 1997 Resolved
INSTALL WATERTIGHT RECEPTICLE ABOVE AUX BOILER IN MACHINERY SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Engineering
Issued 18 July 1997 Resolved
INSTALL METAL TRAYS OR BOWLS UNDER RACOR FILTERS IN THE MACHINERY SPACE FORTHE MAIN ENGINES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 18 July 1997 Resolved
REMOVE DEAD ENDED CABLE FROM LINEN CLOSET._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 18 July 1997 Resolved
PROPERLY CLOSE JUNCTION BOX IN THE LINEN CLOSET._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 18 July 1997 Resolved
PROVE WATER TIGHTNESS OF WTD NUMBER 2 AND THE WTD IN AFT CREWS QUARTERS TO STEERING GEAR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 18 July 1997 Resolved
HYDROSTATICALLY TEST CO2 EXTINGUISHER LOCATED INSIDE FOCSLE DOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 18 July 1997 Resolved
FREE UP GATE VALVE TO FOREPEAK BILGE SUCTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 18 July 1997 Resolved
INSTALL CO2 WARNING SIGNS AT CO2 ALARM IN THE MACHINERY SPACE AND PAINT LOCKER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Engineering
Issued 25 November 1996 Resolved
INSTALL LOW F/O PRESSURE SWITCH IAW 46CFR61.35-3(a)(4) AND CONDUCT TEST IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Engineering
Issued 12 July 1996 Resolved
Make H/W boiler available for fire & waterside examinations.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Provide evidence of calibration of pressure gage on H/W boiler.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996 Resolved
Permanently affix electrical outlet on port bridgewing and renew electricalwiring at outlet.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996 Resolved
Properly ventilate battery boxes on the port boat deck.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996 Resolved
Replace grabline on two ring buoys.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Engineering
Issued 12 July 1996 Resolved
Demonstrate operation of L/O shutdowns on the generator (100 KW) engines.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Cover the exposed electrical parts on the fwd battery charger (adjacent to CO2 bank).
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Repair the spliced cables to the port battery charger in the engineroom.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Engineering
Issued 12 July 1996 Resolved
Overspeed both main engines in the presence of a CG inspector.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996 Resolved
Replace the deteriorated electrical mat behind the main switchboard.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Make all boiler mounts and connecting studs available for inspection.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996 Resolved
Provide a dead man stick for the engineroom switchboard.
Condition: Unknown
Due 31 October 1996
Resolved 7 October 1996
Lifesaving
Issued 12 July 1996 Resolved
Extend waterlight line to ring buoys to 18 feet.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Remove all dead ended electrical cables from the engineroom and cargo holds.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Navigation
Issued 12 July 1996 Resolved
Provide charts updated to most recent Notice to Mariners for route specified on COI.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996 Resolved
Make permanent repairs to the davit foundation to the rescue boat.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 12 July 1996 Resolved
Prove proper operation of the port 100 KW generator engine.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Accommodation/Occupational Safety
Issued 12 July 1996 Resolved
Reroute the drain from the potable water pump away from the ballast pump motor.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996 Resolved
Mount guards over the rotating couplings on the carious engineroom pumps.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Repack all loose cable stuffing tubes in the engineroom fwd bulkhead.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Provide a guard over the electrical throw switch for the port battery tray in the engineroom.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Electrical
Issued 12 July 1996 Resolved
Remove all dead ended wires in the wheel house crawl space.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Lifesaving
Issued 12 July 1996 Resolved
Renew EPIRB battery and hydrostatic release.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Navigation
Issued 12 July 1996 Resolved
Prove operation of signal lamp.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Construction/Loadline
Issued 12 July 1996 Resolved
Repair as original, port & stbd emergency gear watertight hatch aft of wheel house.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Documentation
Issued 12 July 1996 Resolved
Establish valid random drug testing for vessel crew members.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Accommodation/Occupational Safety
Issued 12 July 1996 Resolved
Replace the wooden deck plates in the engineroom with steel.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Fire Fighting
Issued 12 July 1996 Resolved
Provide a label on the fire pump controller switch.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Provide evidence of satisfactory ASME testing of the 600lb relief valves.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Demonstrate the operation of the reverse current relay on both generators.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Provide shutdown controls for the H/W boiler burner, FOTP and other oil pumps. Controls are to be external from the space.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Repair the oil leaks about the F/O filters.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Electrical
Issued 12 July 1996 Resolved
Provide steel bands on the new overhead electrical cables in the engineroom.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Engineering
Issued 12 July 1996 Resolved
Provide evidence that MAWP of S/S and control air receivers is 150 psi or retest relief valves at or below 100 psi.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Engineering
Issued 12 July 1996 Resolved
Test boiler safety valve in presence of Marine Inspector.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Demonstrate operation of boiler automation: temp controls, burner purge / ignition, low water cut outs, ignition failure and low F/O pressure.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Hydro boiler waterside at 1.5 MAWP (22.5 psi) in presence of CG inspector.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Engineering
Issued 12 July 1996 Resolved
Provide containment about the F/O & L/O vents, fill stations or evidence ofportable containment use.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 12 July 1996 Resolved
Renew all batteries in the PFD lights.
Condition: Unknown
Due 31 October 1996
Resolved 25 September 1996
Engineering
Issued 6 June 1994 Resolved
TEST THE TWO 600 PSI AIR RECEIVER RELIEF VAVLES AS PER 46 CFR 61.10-5(i) TOTHE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Fire Fighting
Issued 6 June 1994 Resolved
PROVIDE ONE ADDITIONAL PRESSURE-DEMAND, OPEN-CIRCUIT, SELF-CONTAINED BREATHING APPARATUS PRIOR TO GETTING VESSEL UNDERWAY.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Construction/Loadline
Issued 12 November 1992 Resolved
REPAIR FRACTURE IN SEAM BETWEEN 'A' STRAKE AND CVK PORT SIDE AT FR 57.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Engineering
Issued 11 June 1992 Resolved
REPAIR ENGINEROOM VENTILATION BLOWERS.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Engineering
Issued 11 June 1992 Resolved
LABEL REMOTE VENTILATION SHUTDOWNS FOR ENGINEROOM BLOWERS.
Condition: Unknown
Due 21 July 1992
Resolved 21 July 1992
Lifesaving
Issued 11 June 1992 Resolved
REPAIR OR REPLACE LIFEBOAT DAVIT BRAKE DRUM.
Condition: Unknown
Due 21 July 1992
Resolved 21 July 1992
Electrical
Issued 11 June 1992 Resolved
SUBMIT REVISED ELECTRICAL PLANS FOR NEW A/C GEN INSTALLATION. DO NOT OPERATE UNTIL APPROVED PLANS ARE RECEIVED AND INSTALLATION TESTS CONDUCTED.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Fire Fighting
Issued 11 June 1992 Resolved
POST FIRE CONTROL PLAN IN MAIN PASSAGEWAY.
Condition: Unknown
Due 21 July 1992
Resolved 21 July 1992
Electrical
Issued 14 June 1991 Resolved
INSTALL OR SHOW PROPER (IF PRESENTLY EXISTING) OPERATION OF EXISTING_x001C_ LOW L/O SHUTDOWNS ON BOTH SHIPS SERVICE AND AUX GENERATORS.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Deck/Cargo
Issued 14 June 1991 Resolved
INSTALL OWS MONITOR FOR CONTROL OF OWS TO NOT DISCHARGE MORE THAN 15 PPM._x001C_ ALL WASTE OIL TO BE RETAINED ON BOARD UNTIL INSTALLATION AND TESTING.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.