Records from 2016 to 2026. Most recent: inspection, 22 April 2026.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 April 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2026
Resolution: Vessel purchased new EPIRB and registered with NOAA. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2026
Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION, THE OWNER OR MANAGING OPERATOR MUST BE PREPARED TO CONDUCT TESTS AND HAVE THE VESSEL READY FOR INSPECTION OF ITS FIRE PROTECTION EQUIPMENT, INCLUDING: INSPECTION AND TESTING OF ALARMS FOR EACH FIXED GAS FIRE EXTINGUISHING SYSTEM AND DETECTION SYSTEMS TO DETERMINE THAT THE SYSTEM IS IN OPERATING CONDITION. MI OBSERVED VESSEL'S FIRE BOY DID NOT OPERATE AS DESIGNED DURING TESTING.
46 CFR 176.810(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2026
Resolution: Vessel purchased new FireBoy, tested override and was all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2026
Resolved
A VESSEL ON AN OCEANS, COASTWISE, LIMITED COASTWISE OR GREAT LAKES ROUTE MUST CARRY: SIX HAND RED FLARE DISTRESS SIGNALS AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. MI OBSERVED VESSEL ONLY HAD THREE RED HAND FLARES AND THREE HAND ORANGE SMOKE DISTRESS SIGNALS ONBOARD.
46 CFR 180.68
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2026
Resolution: Vessel purchased required amount of flares.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2026
Resolved
ELECTRICAL EQUIPMENT AMD INSTALLATIONS MUST BE SUITABLE FOR THE ROLL, PITCH, AND VIBRATION OF THE VESSEL UNDERWAY. MI OBSERVED STBD ENGINE STARTER "BOOST SOLENOID" UNSECURED AND LOOSE IN ENGINE ROOM.
46 CFR 183.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2026
Resolution: Vessel secured electrical hazard appropriately. All sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 April 2026
Resolved
VESSELS OPERATED SOLELY WITHIN 20 NAUTICAL MILES OF LAND MUST BE EQUIPPED WITH A VHF-DSC RADIOTELEPHONE INSTALLATION MEETING THE REQUIREMENTS OF 47 CFR 80.1101(c)(2). MI OBSERVED VESSEL'S VHF RADIO DID NOT DISPLAY LAT/LONG POSITION.
47 CFR 80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2026
Resolution: Received photographic evidence of VHF programmed with LAT/LONG. Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2025
Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel had exposed wires in engine room. Either pull wires completely from spaces or put dead ends in junction boxes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2025
Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel has potable water lines running in direct contact with battery selector switch and above battery boxes. Prevent potential of electrical and water cross contamination.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 March 2025
Resolved
A vessel of at least 26 feet, a visual alarm must be provided at the operating station to indicate the operation of the automatic bilge pump. Vessels visual bilge light indicator was not operable. Repair. hourly round of the space while underway until repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2025
Resolved
At every vessel inspection all observed unsafe practice, fire hazards and other hazardous situations must be corrected. Vessel has oil and jacket water mixture in the bilge. Make vessel engine room clean for inspection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 June 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perfrom the duties and functins of a position , required by the vessel's certificate of inspection. Vessel was presented for inspection with a Captain not enrolled ion a drug testing program, and with no pre employment drug testing. provide a list of employees that are enrolled in random drug testing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 June 2024
Resolution: Pre employment drug test complete, all crew enrolled in random drug testing program.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 June 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fuel tank fill cap was loose and unable to be secured. Secure the fill cap.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 19 June 2024
Resolution: New fuel cap fitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2024
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Pump indicator light for pump #2 was inoperable. Repair the light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 19 June 2024
Resolution: pump repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 June 2024
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel was observed in a condition unfit for intended route and service. Complete annual inspection prior to operating.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Annual inspection complete.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 June 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Vessel's Master could not produce a valid medical certificate. Acquire the medical certificate.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Medical exam completed, certificate en route.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 June 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Loose and bare wires were noted in the crew accommodation access area in way of the stairwell.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Wires removed or repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel's starboard propulsion shaft seal was observed leaking water into the engine room bilge. Repair the seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Packing on shaft seal repaired, no leaks observed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 4 June 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Master could not provide verification of an accurate MMSI number on the vessel's VHF radio. Provide proof that assigned MMSI number is input into the VHF radio.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Operator displayed correct MMSI number on vessel's VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets were stored with adult. Separate the life jackets.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Lifejackets segregated and stored appropriately.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2024
Resolved
At least one ring life buoy must be fitted with a lifeline with a breaking strength of at least 1,124 pounds. Life ring buoy was found with a degraded lifeline. Replace the lifeline.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Line was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 June 2024
Resolved
A crew accommodation space and a work space must be provided with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew. Stairs leading to crew space found unsafe. Make the stairs safe.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 12 June 2024
Resolution: Operator installed non-slip material affixed to each stair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that The pump is permanently mounted. Vessel's electric bilge pump in the engine room was found not mounted to the deck. Permanently affix the pump to the deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 12 June 2024
Resolution: Bilge pump mounted to the deck and operable.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 June 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel had no portable lights. Acquire the portable lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 12 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 June 2023
Resolved
At every vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. The bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard. Vessel was found to have excessive oil saturated on port engine starter and small accumulation of oil in the engine space bilge. Remove excess oil from engine room bilges and starter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 6 June 2023
Resolution: Received photographic evidence of oil removed from bilge and starter and clean absorbent pad installed in bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
Main diesel fuel strainers shall be provided with caps or plugs to prevent fuel leakage. Starboard main engine strainer is missing cap, replace.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 11 June 2023
Resolution: Received objective evidence from vessel of plugs on fuel filters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2023
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel...installed and maintained to provide adequate protection from personal injury. Vessels main engines were missing machinery belt cover guards, reinstall.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 11 June 2023
Resolution: Received evidence of machinery covers installed on main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023
Resolved
Visual and audible alarm must be provided in all unmanned spaces. Alarm panel did not segregate spaces. Make lights location specific.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 12 June 2023
Resolution: Received evidence that vessel's high level alarms are operable in accordance iwth regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2022
Resolved
On a vessel of more than 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in certain normally unmanned spaces. Visual lights broken for compartment 3 (midship) and compartment 5 (lazarette). Provide proof of repaired visual alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 27 June 2022
Resolution: Received video of newly installed panel. All five compartments shown sat for audible/visual alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2022
Resolved
Each ring life buoy must be marked with Type II retro-reflective material. ring life buoy has worn retro. Provide proof of replaced retro.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 13 June 2022
Resolution: Photo provided, see def docs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 June 2022
Resolved
The master of a vessel shall ensure that one or more garbage handling placards are on board. No placard on board. Provide proof of placard on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 13 June 2022
Resolution: Photo sent of garbage placard, see def docs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2021
Resolved
Life ring light could not be verified to meet 160.050 and battery was expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2021
Resolved 29 April 2021
Resolution: Replaced life ring light with a new approved light and batteries.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 April 2021
Resolved
First aid kit had expired and missing items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2021
Resolved 29 April 2021
Resolution: Replaced first aid kit with unexpired and complete kit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 April 2021
Resolved
Vessel's anchor light was not approved and missing the housing and the stern light was incorrectly mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Replaced anchor light and housing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 April 2021
Resolved
Vessel did not have two operable portable battery lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Portable light batteries were changed and corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2021
Resolved
Remote fuel shutoff was not clearly marked for purpose or for direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Fuel shutoff valves have been marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2021
Resolved
Vessel was missing one of the required three fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Fire buckets were replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2021
Resolved
The bilge pump in the engine room was wired with wire nuts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: The wiring was corrected with approved connector.
Engineering › Fuel Oil Service System › Valve
Issued 24 April 2018
Resolved
Label emergency fuel shutoff vavles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2018
Resolved 11 May 2018
Resolution: Received picture with the satisfactory marking of emergency fuel shut offs.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2017
Resolved
All around white light needs to be working.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Nav Light operational.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 February 2017
Resolved
Engine belt guard is rubbing on belt.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Engine belts repaired.
Engineering › Steering Gear System › Hydraulic Hose
Issued 17 May 2016
Resolved
Steering fluid leak in laz on hydraulic ram. Make repairs as needed to stop leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 13 June 2016
Resolution: Hydraulic ram repaired as needed all found sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2016
Resolved
Bilge wiring needs to have wire supports every 24”. Keep wires out of bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Bilge wiring properly supported and out of bilge.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2016
Resolved
Line for ring buoy needs replaced also line on water light needs replaced along w/ battery that expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Life ring buoy and water light line found sat. Replaced batteries.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2016
Resolved
Add cable clamp to the wire rope for gangway, needs two.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 17 May 2016
Resolution: Cable clamp added.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 May 2016
Resolved
Ladder used for man over board needs cleaned and lubed to work properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 17 May 2016
Resolution: Shackle added to ladder. Ladder works properly.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 May 2016
Resolved
Panel box in engine room needs a new label. Hard to read.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Panel box in engine room properly labeled.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 17 May 2016
Resolved
Review emergency instructions and make changes to align with vessel, and post at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Emergency instructions found sat.
Stability › Watertight Integrity › General
Issued 8 March 2016
Resolved
Make all deck hatches weather-tight, with securing devices, and fix framing of forward door, to make weather-tight. IAW 46 CFR 179.360.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 14 March 2016
Resolution: All deck hatches had securing devices, and weather tight. Forward door had new framing piece installed.