MAURY USCG vessel records Sign in
← All vessels

DUKE

DUKE is a 1990 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1990, most recently in April 2026, along with 256 deficiencies.

Records from 1990 to 2026. Most recent: inspection, 22 April 2026.

Built
1990
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WMD8503
338460
Flag
UNITED STATES
368221180, 368243850
Maury page id
psix-338460

Inspections, by type

…with no type recorded3
Years with a record 33 calendar years (1990–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 18.0 ft × 6.0 ft
Registered tonnagegross 31 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDAUPHIN ISLAND, AL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Net Ton
31 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM8503MMSI 368243850 · active · voluntarily equipped · granted 11 March 2022, expires 11 March 2032
WDM5989MMSI 368221180 · active · compulsorily equipped · granted 30 September 2021, expires 30 September 2031
WDC6706MMSI 367060050 · expired · compulsorily equipped · granted 24 July 2015, cancelled 6 September 2025
WCO7457MMSI not assigned · expired · compulsorily equipped · granted 14 November 1994, cancelled 15 January 2005
WCL4592MMSI not assigned · expired · voluntarily equipped · granted 11 August 1994, cancelled 16 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 72

22 April 2026 COI Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8331887
30 December 2025 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8288422
7 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8130539
7 October 2024 Administrative Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8028230
3 June 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7926207
2 May 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7905447
18 December 2023 Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841194
20 April 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7672373
10 June 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7473463
24 January 2022 In-Service Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7384603
15 April 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7175756
22 June 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6983528
14 February 2020 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6909091
9 April 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6659208
11 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6411919
30 March 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6382116
27 February 2018 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6356524
9 February 2017 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6085506
13 June 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5907055
13 April 2016 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5853716
14 March 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5834018
28 January 2016 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5805543
22 May 2014 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4865311
30 March 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3698641
19 January 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3664517
20 March 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3436862
21 May 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3212101
22 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3172808
12 December 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3111368
25 April 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2898533
14 April 2006 COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2624583
2 December 2005 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2541695
4 October 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2507835
8 September 2005 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2490802
19 April 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2336669
4 September 2004 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 2186490
9 April 2004 In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2041021
24 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2030243
2 December 2003 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1957052
28 April 2003 Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1781908
3 June 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1625495
24 April 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1608616
7 January 2002 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1476292
2 January 2002 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1474836
23 April 2001 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1366289
8 June 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1051208
30 May 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1381909
11 November 1999 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1429246
23 September 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1036658
9 September 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1120532
1 July 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1089429
22 June 1999 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1444180
3 April 1999 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1510196
27 April 1998 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1408102
26 September 1997 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1372001
26 August 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1450076
1 July 1996 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1087035
26 June 1996 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1430230
31 October 1995 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 882890
5 October 1995 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1463921
27 September 1995 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1419508
26 July 1994 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1359878
27 July 1993 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 845712
24 June 1993 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1423789
10 June 1993 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1415852
13 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 165682
4 August 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 939800
8 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263761
20 September 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932730
26 June 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1244481
6 June 1990 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906608
6 June 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 956869

Deficiency record · 256

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 April 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2026
Resolution: Vessel purchased new EPIRB and registered with NOAA. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2026 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION, THE OWNER OR MANAGING OPERATOR MUST BE PREPARED TO CONDUCT TESTS AND HAVE THE VESSEL READY FOR INSPECTION OF ITS FIRE PROTECTION EQUIPMENT, INCLUDING: INSPECTION AND TESTING OF ALARMS FOR EACH FIXED GAS FIRE EXTINGUISHING SYSTEM AND DETECTION SYSTEMS TO DETERMINE THAT THE SYSTEM IS IN OPERATING CONDITION. MI OBSERVED VESSEL'S FIRE BOY DID NOT OPERATE AS DESIGNED DURING TESTING. 46 CFR 176.810(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2026
Resolution: Vessel purchased new FireBoy, tested override and was all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2026 Resolved
A VESSEL ON AN OCEANS, COASTWISE, LIMITED COASTWISE OR GREAT LAKES ROUTE MUST CARRY: SIX HAND RED FLARE DISTRESS SIGNALS AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. MI OBSERVED VESSEL ONLY HAD THREE RED HAND FLARES AND THREE HAND ORANGE SMOKE DISTRESS SIGNALS ONBOARD. 46 CFR 180.68
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2026
Resolution: Vessel purchased required amount of flares.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2026 Resolved
ELECTRICAL EQUIPMENT AMD INSTALLATIONS MUST BE SUITABLE FOR THE ROLL, PITCH, AND VIBRATION OF THE VESSEL UNDERWAY. MI OBSERVED STBD ENGINE STARTER "BOOST SOLENOID" UNSECURED AND LOOSE IN ENGINE ROOM. 46 CFR 183.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2026
Resolution: Vessel secured electrical hazard appropriately. All sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 April 2026 Resolved
VESSELS OPERATED SOLELY WITHIN 20 NAUTICAL MILES OF LAND MUST BE EQUIPPED WITH A VHF-DSC RADIOTELEPHONE INSTALLATION MEETING THE REQUIREMENTS OF 47 CFR 80.1101(c)(2). MI OBSERVED VESSEL'S VHF RADIO DID NOT DISPLAY LAT/LONG POSITION. 47 CFR 80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2026
Resolution: Received photographic evidence of VHF programmed with LAT/LONG. Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2025 Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel had exposed wires in engine room. Either pull wires completely from spaces or put dead ends in junction boxes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2025 Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel has potable water lines running in direct contact with battery selector switch and above battery boxes. Prevent potential of electrical and water cross contamination.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 March 2025 Resolved
A vessel of at least 26 feet, a visual alarm must be provided at the operating station to indicate the operation of the automatic bilge pump. Vessels visual bilge light indicator was not operable. Repair. hourly round of the space while underway until repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 March 2025 Resolved
At every vessel inspection all observed unsafe practice, fire hazards and other hazardous situations must be corrected. Vessel has oil and jacket water mixture in the bilge. Make vessel engine room clean for inspection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Received objective evidence of deficiencies rectified.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 June 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perfrom the duties and functins of a position , required by the vessel's certificate of inspection. Vessel was presented for inspection with a Captain not enrolled ion a drug testing program, and with no pre employment drug testing. provide a list of employees that are enrolled in random drug testing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 June 2024
Resolution: Pre employment drug test complete, all crew enrolled in random drug testing program.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fuel tank fill cap was loose and unable to be secured. Secure the fill cap.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 19 June 2024
Resolution: New fuel cap fitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2024 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Pump indicator light for pump #2 was inoperable. Repair the light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 19 June 2024
Resolution: pump repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 June 2024 Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel was observed in a condition unfit for intended route and service. Complete annual inspection prior to operating.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Annual inspection complete.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 June 2024 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Vessel's Master could not produce a valid medical certificate. Acquire the medical certificate.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Medical exam completed, certificate en route.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Loose and bare wires were noted in the crew accommodation access area in way of the stairwell.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Wires removed or repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel's starboard propulsion shaft seal was observed leaking water into the engine room bilge. Repair the seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Packing on shaft seal repaired, no leaks observed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 4 June 2024 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Master could not provide verification of an accurate MMSI number on the vessel's VHF radio. Provide proof that assigned MMSI number is input into the VHF radio.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Operator displayed correct MMSI number on vessel's VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets were stored with adult. Separate the life jackets.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Lifejackets segregated and stored appropriately.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2024 Resolved
At least one ring life buoy must be fitted with a lifeline with a breaking strength of at least 1,124 pounds. Life ring buoy was found with a degraded lifeline. Replace the lifeline.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2024
Resolution: Line was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 June 2024 Resolved
A crew accommodation space and a work space must be provided with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew. Stairs leading to crew space found unsafe. Make the stairs safe.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 12 June 2024
Resolution: Operator installed non-slip material affixed to each stair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that The pump is permanently mounted. Vessel's electric bilge pump in the engine room was found not mounted to the deck. Permanently affix the pump to the deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 12 June 2024
Resolution: Bilge pump mounted to the deck and operable.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 June 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel had no portable lights. Acquire the portable lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 12 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 June 2023 Resolved
At every vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. The bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard. Vessel was found to have excessive oil saturated on port engine starter and small accumulation of oil in the engine space bilge. Remove excess oil from engine room bilges and starter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 6 June 2023
Resolution: Received photographic evidence of oil removed from bilge and starter and clean absorbent pad installed in bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023 Resolved
Main diesel fuel strainers shall be provided with caps or plugs to prevent fuel leakage. Starboard main engine strainer is missing cap, replace.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 11 June 2023
Resolution: Received objective evidence from vessel of plugs on fuel filters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel...installed and maintained to provide adequate protection from personal injury. Vessels main engines were missing machinery belt cover guards, reinstall.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 11 June 2023
Resolution: Received evidence of machinery covers installed on main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023 Resolved
Visual and audible alarm must be provided in all unmanned spaces. Alarm panel did not segregate spaces. Make lights location specific.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 12 June 2023
Resolution: Received evidence that vessel's high level alarms are operable in accordance iwth regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2022 Resolved
On a vessel of more than 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in certain normally unmanned spaces. Visual lights broken for compartment 3 (midship) and compartment 5 (lazarette). Provide proof of repaired visual alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 27 June 2022
Resolution: Received video of newly installed panel. All five compartments shown sat for audible/visual alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2022 Resolved
Each ring life buoy must be marked with Type II retro-reflective material. ring life buoy has worn retro. Provide proof of replaced retro.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 13 June 2022
Resolution: Photo provided, see def docs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 June 2022 Resolved
The master of a vessel shall ensure that one or more garbage handling placards are on board. No placard on board. Provide proof of placard on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 13 June 2022
Resolution: Photo sent of garbage placard, see def docs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2021 Resolved
Life ring light could not be verified to meet 160.050 and battery was expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2021
Resolved 29 April 2021
Resolution: Replaced life ring light with a new approved light and batteries.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 April 2021 Resolved
First aid kit had expired and missing items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2021
Resolved 29 April 2021
Resolution: Replaced first aid kit with unexpired and complete kit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 April 2021 Resolved
Vessel's anchor light was not approved and missing the housing and the stern light was incorrectly mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Replaced anchor light and housing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 April 2021 Resolved
Vessel did not have two operable portable battery lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Portable light batteries were changed and corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2021 Resolved
Remote fuel shutoff was not clearly marked for purpose or for direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Fuel shutoff valves have been marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2021 Resolved
Vessel was missing one of the required three fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 5 May 2021
Resolution: Fire buckets were replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2021 Resolved
The bilge pump in the engine room was wired with wire nuts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: The wiring was corrected with approved connector.
Engineering › Fuel Oil Service System › Valve
Issued 24 April 2018 Resolved
Label emergency fuel shutoff vavles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2018
Resolved 11 May 2018
Resolution: Received picture with the satisfactory marking of emergency fuel shut offs.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2017 Resolved
All around white light needs to be working.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Nav Light operational.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 February 2017 Resolved
Engine belt guard is rubbing on belt.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Engine belts repaired.
Engineering › Steering Gear System › Hydraulic Hose
Issued 17 May 2016 Resolved
Steering fluid leak in laz on hydraulic ram. Make repairs as needed to stop leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 13 June 2016
Resolution: Hydraulic ram repaired as needed all found sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2016 Resolved
Bilge wiring needs to have wire supports every 24”. Keep wires out of bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Bilge wiring properly supported and out of bilge.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2016 Resolved
Line for ring buoy needs replaced also line on water light needs replaced along w/ battery that expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Life ring buoy and water light line found sat. Replaced batteries.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2016 Resolved
Add cable clamp to the wire rope for gangway, needs two.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 17 May 2016
Resolution: Cable clamp added.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 May 2016 Resolved
Ladder used for man over board needs cleaned and lubed to work properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 17 May 2016
Resolution: Shackle added to ladder. Ladder works properly.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 May 2016 Resolved
Panel box in engine room needs a new label. Hard to read.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Panel box in engine room properly labeled.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 17 May 2016 Resolved
Review emergency instructions and make changes to align with vessel, and post at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 13 June 2016
Resolution: Emergency instructions found sat.
Stability › Watertight Integrity › General
Issued 8 March 2016 Resolved
Make all deck hatches weather-tight, with securing devices, and fix framing of forward door, to make weather-tight. IAW 46 CFR 179.360.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 14 March 2016
Resolution: All deck hatches had securing devices, and weather tight. Forward door had new framing piece installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 March 2010 Resolved
Retape 18 life jackets as discussed and replace the 3 adult life jackets that were rejected and 1 child life jacket.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: All issued with the life jackets were resolved.
Personnel › Training › First Aid/CPR
Issued 30 March 2010 Resolved
Provide proof of crews first aid and CPR training.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The crew had the cards proving they attend the training.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 March 2010 Resolved
Properly label life jacket stowage and separate the adult and child life jackets.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The stowage areas were properly labeled and separated.
Navigation › Piloting/Steering › Marine Charts
Issued 30 March 2010 Resolved
Provide charts for the area being navigated.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: New charts were onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2010 Resolved
Provide an approved first aid kit or equivalent with list of contents.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: A new first aid kit was purchased.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 30 March 2010 Resolved
Provide and install a cover for the junction box located in the engine room on the starboard main engine stringer.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: A cover was installed on the junction box.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 March 2010 Resolved
Provide and install hose clamps on the port and starboard main engine exhaust to meet the double hose clamp requirements.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The required hose clamps were installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2010 Resolved
Properly secure the insulation in the overhead of the engine room.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The insulation was properly secured.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 30 March 2010 Resolved
Provide and install fuel shut off valves at both main engines.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The valves were installed.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 30 March 2010 Resolved
Make repairs to both main engines to secure lube oil leaks.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 18 April 2011
Resolution: New engines were installed since deficiency was issued.
Engineering › Bilge Water Management System › Valve
Issued 30 March 2010 Resolved
Provide and install an overboard discharge through hull penetration and shut off valve for the bilge pump in the forepeak.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The through hull penetration and valve was installed.
Engineering › Bilge Water Management System › Not Operational
Issued 30 March 2010 Resolved
Prove proper operation of the bilge pump in the forepeak .
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The pump was proven.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 30 March 2010 Resolved
Properly label bilge high level alarm and bilge pump indicator light panels at the operating station.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: The bilge high level alarms and bilge pumps were labeled
Communications › Radio Communications › EPIRB
Issued 30 March 2010 Resolved
Service the EPIRB to replace the deteriorated lines on the unit.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 6 May 2010
Resolution: A new EPIRB was purchased and registered.
Lifesaving › Lifefloat › Float-free Link
Issued 30 March 2010 Resolved
Properly stow the life floats and provide a weak link and properly install in an approved spool canister for the painter line.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 18 April 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 January 2010 Resolved
Provide and install a guard over the chain/sprocket assembly for the trawler net.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: A rotating guard was placed over the chain/sprocket assembly as required.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 January 2010 Resolved
Prove proper operation of hatch leading to the lazarette.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Hatch was inspected and found to be in satisfactory condition.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 January 2010 Resolved
Remove used oil buckets, battery charger, and other misc items from in front of pre-engineered fire system.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: All items were removed from in front of fixed fire system as required.
Construction/Loadline › Structures › Superstructure
Issued 19 January 2010 Resolved
Make proper repairs or replace pilot house window.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Pilot house window was replaced with approved materials and found to be in satisfactory condition.
Construction/Loadline › Structures › Ventilators
Issued 19 January 2010 Resolved
Replace starboard side vent below pilot house.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Vent was replaced as required and found in satisfactory condition.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 January 2010 Resolved
Provide and install mounting screw on hydraulic tank for steering.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Mounting screw was installed and upon inspection the tank was found to be satisfactory.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 19 January 2010 Resolved
Make repairs to stop excessive lube oil leaks on both main diesel engines.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Excessive lube oil leaks were repaired and engines were found to be in satisfactory condition.
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2010 Resolved
Make repairs to hull as discussed and marked.
Action required: 705 - Other - as specified
Resolved 27 January 2010
Resolution: Vessel hull repairs were satisfactory.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 January 2010 Resolved
Make propellers available for inspection.
Action required: 705 - Other - as specified
Resolved 27 January 2010
Resolution: Props were made available to inspectors and were found in satisfactory condition.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 19 January 2010 Resolved
Make lazarette ready for inspection.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Lazarette was pumped out and upon inspection was found to be in satisfactory condition.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 16 April 2009 Resolved
Secure oil leaks on both main engines per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Oil leaks were secured.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 16 April 2009 Resolved
Repair handle of emergency fuel shut-off for port engine per 46 CFR 182.20-40.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Fuel shut-off was repaired and is operable.
Lifesaving › Lifefloat › Painter
Issued 16 April 2009 Resolved
Arrange painter of lifefloat for float-free operation per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Painter is arranged for float-free operation.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2009 Resolved
Replace expired battery in waterlight for lifefloat per 46 CFR 185.726.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Battery was replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 2008 Resolved
Prove proper operation of starboard navigation light.
Due 22 May 2008
Resolved 22 April 2008
Resolution: Operator replaced bulb, light proved operable.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 April 2008 Resolved
Replace 9 rejected lifejackets and 1 missing lifejacket so that vessel will have a total of 51 adult lifejackets as required by COI.
Due 22 May 2008
Resolved 21 May 2008
Resolution: Nine new lifejackets were purchase and properly marked and placed on the vessel.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 April 2008 Resolved
Replace deteriorated electric winch used on the on/off ramp on bow.
Due 22 May 2008
Resolved 21 May 2008
Resolution: The winch used to lift the ramp was replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 April 2008 Resolved
Prove proper operation of the pre-engineered fire fighting system. Currently, when the engines do not shut off when the system is activated.
Due 22 May 2008
Resolved 21 May 2008
Resolution: The operations of the pre-engineered fire suppression system were proven.
Engineering › Sea-water System (primary cooling) › Pump
Issued 22 April 2008 Resolved
Replace leaking raw water cooling pump for starboard main engine.
Due 22 May 2008
Resolved 21 May 2008
Resolution: The leaking raw water cooling pump on the starboard engine was replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 22 April 2008 Resolved
Properly vent both main engine valve covers.
Due 22 May 2008
Resolved 21 May 2008
Resolution: Bothe main engine valve covers were properly vented.
Documentation › Logs/Records › Logbook (official)
Issued 22 April 2008 Resolved
Properly log monthly tests of the EPIRB.
Due 22 May 2008
Resolved 21 May 2008
Resolution: The monthly test of the EPIRB was logged.
Construction/Loadline › Hull › Bottom Plating
Issued 12 December 2007 Resolved
Repair/replace bad patch on hull starboard side approximately 5 ft from bow on/next to keel.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Hull › Bottom Plating
Issued 12 December 2007 Resolved
Grind and reglass all areas on hull that are marked with chalk.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 December 2007 Resolved
Make propellers ready for inspection.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 12 December 2007 Resolved
Prove proper operation of valve for starboard engine raw water intake.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 December 2007 Resolved
Make forepeak tank watertight and hose test newly installed hatch prior to vessel operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2008
Resolved 30 January 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Repair stanchion on starboard side located at aft entrance on the starboard quarter (forward of two stanchions).
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 December 2007 Resolved
Make both port and starboard exhaust watertight at the hull.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Repair deck transom located in vicinity of aft stanchion approximately 4 ft in from port side on stern.
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Hull › Strut/Cross Tie
Issued 12 December 2007 Resolved
Crop/renew deck beam located in forward storage area on port side off of centerline.
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 December 2007 Resolved
Repair/replace closet bulkheads located in forward storage area.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Hull › Strut/Cross Tie
Issued 12 December 2007 Resolved
Grind/reglass two areas located in forward storage area; one on starboard side above storage compartment, other on port side above storage compartment.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Structures › Superstructure
Issued 12 December 2007 Resolved
Make Pilothouse weather tight.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Engineering › Steering Gear System › Rudder
Issued 12 December 2007 Resolved
Make rudder ready for inspection after repairs are made.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Structures › Superstructure
Issued 12 December 2007 Resolved
Crop/renew rotten wood located on main deck starboard side breezeway leading from pilothouse to passenger area.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Stability › Watertight Integrity › General
Issued 12 December 2007 Resolved
Make penetration for hydraulic hose for trawler leading from main deck to lazerette watertight.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Fire Fighting › Fire Main › Valves
Issued 12 December 2007 Resolved
provide plug for ball valve for fire main located in mid-body compartment.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Engineering › Lubricating Oil Service System › Tank
Issued 12 December 2007 Resolved
Secure leak on hydraulic tank in mid-body compartment.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 December 2007 Resolved
Replace cutlass bearings and make shafts ready for inspection.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 December 2007 Resolved
Crop/renew/reglass longitudinal deck beams located in engine room overhead deck stringers port and starboard inboard of each main engine as marked.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 December 2007 Resolved
Crop/renew/reglass longitudinal deck stringers port to starboard, entire breath of vessel, aft of main engines.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Stability › Watertight Integrity › General
Issued 12 December 2007 Resolved
Seal up all bulkhead penetrations for bulkhead forward of mid-body compartment.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 14 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2007 Resolved
Replace the broken lens on the starboard running light.
Due 25 May 2007
Resolved 25 May 2007
Resolution: The broken lens was replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 April 2007 Resolved
Remove the wire nuts or place inside an electrical junction box and tape for the stern light as per 46 CFR 183.340 (i).
Due 25 May 2007
Resolved 25 May 2007
Resolution: A junction box was installed and the connections were properly taped inside the box.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 25 April 2007 Resolved
Prove proper operation of the ship's horn as per 46 CFR 86.
Due 25 May 2007
Resolved 25 May 2007
Resolution: The horn was repaired.
Lifesaving › Hand Flares › Storage
Issued 25 April 2007 Resolved
Properly stow the flares and smoke signals in a water tight container and stow in the wheel house as per 46 CGR 185.614.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A water tight container was provided and stowed in the wheel house.
Communications › Public Address System › Announcing Station
Issued 25 April 2007 Resolved
Prove proper operation of the public address system as per 46 CFR 184.610.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A new system was installed and tested with satisfactory results.
Stability › Weathertight Integrity › General
Issued 25 April 2007 Resolved
Provide and install the missing securing device for the center forward window in the wheel house as per 46 CFR 176.800.
Due 25 May 2007
Resolved 25 May 2007
Resolution: Proper repairs were made to the securing device.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2007 Resolved
Provide and install a latch for the gate on the starboard side aft railing as per 46 CFR 177.900.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A latch was installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2007 Resolved
Provide a first aid kit of an approved type as per 46 CFR 184.710.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A new Coast Guard approved first aid kit was provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 April 2007 Resolved
Prove the pre-engineered fixed fire extinguishing system meets all the safety requirements in that the pull cable in the engine room is exposed and could easily be pulled inadvertently as per 46 CFR 176.800.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A new pre-engineered system was installed and properly test.
Engineering › Bilge Water Management System › Pump
Issued 25 April 2007 Resolved
Replace the deteriorated (dry rotten) flexible hose on the discharge side of the fire/bilge Pump as per 46 CFR 181.310.
Due 25 May 2007
Resolved 26 April 2007
Resolution: The hose was replaced.
Engineering › Bilge Water Management System › Pump
Issued 25 April 2007 Resolved
Prove proper operation of the fire/bilge pump as per 46 CFR 181.310.
Due 25 May 2007
Resolved 26 April 2007
Resolution: The pump was rebuilt and tested.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 April 2007 Resolved
Make proper repairs to the broken securing device for the raw water strainer for the port main engine as per 46 CFR 176.800.
Due 25 May 2007
Resolved 25 May 2007
Resolution: The securing device was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 25 April 2007 Resolved
Prove proper operation of both main engine starters in accordance with 46 CFR 176.800.
Due 25 May 2007
Resolved 25 May 2007
Resolution: Both main engine starter were rebuilt and tested.
Engineering › Bilge Water Management System › Valve
Issued 25 April 2007 Resolved
Provide and install a valve handle for the stop valve on the bilge manifold as per 46 CFR 182.510.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A valve handle was installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 April 2007 Resolved
Remove all dead end cables in the engine room and mid body compartment as per 46 CFR 183.340.
Due 25 May 2007
Resolved 25 May 2007
Resolution: The cables were removed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 April 2007 Resolved
Provide and install a cover for the electrical junction box on the forward engine room bulkhead as per 46 CFR 183.340.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A cover was installed on the box.
Lifesaving › Lifefloat › Netting
Issued 25 April 2007 Resolved
Replace the 22 person life float, the retainer straps for the netting are deteriorated and broken as per 46 CFR 180.200.
Due 25 May 2007
Resolved 26 April 2007
Resolution: A new life float was purchased and placed onboard with the proper marking and equipment.
Lifesaving › Lifefloat › Markings
Issued 25 April 2007 Resolved
Properly mark the 12 persons life float with the vessel's name and the capacity as per 46 CFR 185.604(a).
Due 25 May 2007
Resolved 25 May 2007
Resolution: The life float was properly marked.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2007 Resolved
Properly mount the bilge high level alarm in the lazarette as per 46 CFR 182.510.
Due 25 May 2007
Resolved 25 May 2007
Resolution: The alarm was properly mounted.
Engineering › Bilge Water Management System › Not Installed
Issued 25 April 2007 Resolved
Provide and install a valve at the through hull fitting for the independent electric submersible bilge pump overboard discharge as per 46 CFR 182.510.
Due 25 May 2007
Resolved 25 May 2007
Resolution: A valve was install at the through hull fitting.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2006 Resolved
Support all electrical wiring with metal wire supports every 24 inches throughout the vessel. in accordance with 46 CFR 183.340
Due 14 May 2006
Resolved 1 May 2006
Resolution: Metal wire were installed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 April 2006 Resolved
Replace hoses clamps on the sewage tank non-metallic piping.
Due 14 May 2006
Resolved 1 May 2006
Resolution: Hose clamps were installed on the piping.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 April 2006 Resolved
Provide and install cover for the electrical distribution panel board in the forward compartment in accordance with 46 CFR 183.200
Due 14 May 2006
Resolved 1 May 2006
Resolution: Covers were installed on the panels.
Engineering › Bilge Water Management System › Pump
Issued 14 April 2006 Resolved
Provide and install an indicator light at the operating station to indicate the bilge pumps are operating in accordance with 46 CFR182.520.
Due 14 May 2006
Resolved 1 May 2006
Resolution: Indicator light were installed at the operating station.
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2006 Resolved
Provide two means of securing the fuel to both main diesel engines in accordance with 46 CFR 182.455.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The valves were installed as required.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 April 2006 Resolved
Double clamp all hoses through out the engine room in accordance with 46CFR 182.715
Due 14 May 2006
Resolved 1 May 2006
Resolution: All hoses were double clamped.
Engineering › Bilge Water Management System › Valve
Issued 14 April 2006 Resolved
Provide and install a valve handle on the bilge overboard discharge valve on the starboard side of the engine room.
Due 14 May 2006
Resolved 1 May 2006
Resolution: Installed a valve handle on the bilge overboard discharge valve on the starboard side of the engine room.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 14 April 2006 Resolved
Make repairs to the excessive oil leaks on the port main engine
Due 14 May 2006
Resolved 1 May 2006
Resolution: Repairs to the excessive leaking on the port main engine were made
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 April 2006 Resolved
Prove and installed guards over rotating machinery for both main engines in accordance with 46 CFR 177.960
Due 14 May 2006
Resolved 5 July 2006
Resolution: Guards were installed over rotating machinery for both main engines
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2006 Resolved
Provide a first aid kit that meets the requirements of 46 CFR 160.041 or an equivalent.
Due 14 May 2006
Resolved 1 May 2006
Resolution: A new Coast Guard approved was purchased.
Lifesaving › Buoyant Apparatus › Marking
Issued 14 April 2006 Resolved
Properly mark the forward life float in accordance with 46 CFR 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2006
Resolved 1 May 2006
Resolution: The life float was properly was marked.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 April 2006 Resolved
Properly attach the paddles to the life float in accordance with 46 CFR 180.75
Due 14 May 2006
Resolved 1 May 2006
Resolution: The paddles were properly attached.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 April 2006 Resolved
Either service the aft 12 persons life float and bring it up to standards or replace in accordance with 46 CFR 180.200.
Due 14 May 2006
Resolved 1 May 2006
Resolution: A new 12 persons life float was purchased and install onboard the vessel.
Lifesaving › Buoyant Smoke Signals › General
Issued 14 April 2006 Resolved
Provide three smoke distress signals as required by 46 CFR 180.68
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2006
Resolved 1 May 2006
Resolution: Three smoke signals were purchased and put on board.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 April 2006 Resolved
Provide and install a visual light for the bilge high level alarm at the operating station in accordance with 46 CFR 182.530
Due 14 May 2006
Resolved 1 May 2006
Resolution: The visual light/alarm was installed at the operating station.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 14 April 2006 Resolved
Prove proper operation of GSP in accordance with 46 CFR 176.800.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The system repaired.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 April 2006 Resolved
Prove proper operation of the radar in accordance with 46 CFR 176.800.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The radar is not required because of the route so it was removed.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Prove proper operation of the ship's signaling device in accordance with 33 CFR 86.
Due 14 May 2006
Resolved 1 May 2006
Resolution: Proper operation of the ship''''s signaling device was proven.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Provide an updated coast pilot in accordance with 46 CFR 184.420.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The applicable section of the coast pilot was on board.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Provide current charts of the area of operations in accordance with 46 CFR 184.420.
Due 14 May 2006
Resolved 1 May 2006
Resolution: New charts were onboard.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Post emergency instructions in accordance with 46 CFR 185.510.
Due 14 May 2006
Resolved 1 May 2006
Resolution: Emergency instruction were posted.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Provide a current bridge log in accordance with 46 CFR 185.702.
Due 14 May 2006
Resolved 5 July 2006
Resolution: A current bridge was provide.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Provide a life saving equipment maintenance record with required entries in accordance with 46 CFR 185.702
Due 14 May 2006
Resolved 5 July 2006
Resolution: A life saving equipment maintenance record was provide.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 April 2006 Resolved
Provide a training log book in accordance with 46 CFR 185.420.
Due 14 May 2006
Resolved 5 July 2006
Resolution: A training log book was provided.
Documentation › Certificates/Documents › Stability Letter
Issued 14 April 2006 Resolved
Post the stability letter in accordance with 46 CFR 176.306.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The stability was posted.
Documentation › Certificates/Documents › FCC SSL
Issued 14 April 2006 Resolved
Provide a current marine radio operator's permit.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The Master had a marine radio operator''s permit.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 14 April 2006 Resolved
Provide a current FCC safety certificate in accordance with 47 CFR 902.
Due 14 May 2006
Resolved 1 May 2006
Resolution: The was a current FCC safety certificate onboard.
Operations/Management › Drills/Instruction › Fire
Issued 14 April 2006 Resolved
Complete all underway drill and engine room operational test.
Due 14 May 2006
Resolved 10 July 2006
Resolution: Got underway and conducted drills and operational test of the main engines with satisfactory results.
Construction/Loadline › Structures › Scuttle
Issued 2 December 2005 Resolved
Repair or renew lazarette hatch on main deck aft and prove watertightness to the satisfaction of the attending Marine inspector as required by 46 CFR 179.360
Due 22 February 2006
Resolved 14 April 2006
Resolution: A new hatch was installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 December 2005 Resolved
Have vessel fumigated to rid of cockroaches.
Action required: 705 - Other - as specified
Resolved 16 February 2006
Resolution: Vessel bugged bombed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2005 Resolved
Mast head light hidden behind radar renew as per 72 COLREGS.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 11 May 2005
Resolution: Mast headlight was raised.
Communications › Audible Communications › Horn/Whistle
Issued 19 April 2005 Resolved
Renew/repair horn as per 33 CFR Part 86.
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 11 May 2005
Resolution: Horn was replaced as requested.
Communications › Radio Communications › EPIRB
Issued 19 April 2005 Resolved
Renew/Replace EPIRB battery as per 46 CFR 180.64.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Resolution: EPIRB battery was replaced.
Communications › Radio Communications › EPIRB
Issued 19 April 2005 Resolved
Replace EPIRB hydrostatic release in accordance with 46 CFR 180.64.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Resolution: EPIRB hydrostatic release was replaced.
Lifesaving › Lifefloat › Painter
Issued 19 April 2005 Resolved
Provide line connecting lifefloats long enough to allow each to float free as per 46 CFR 180.137(e)(3).
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 11 May 2005
Resolution: Line was replaced with longerline allowing the life floats to float freely from one another.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 April 2005 Resolved
Renew/replace retroreflective material on 2 children's PFDs as per 46 CFR 185.604(h).
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 11 May 2005
Resolution: Retro-reflective tape was replaced.
Communications › Alarms/Indicators › High Water Alarm
Issued 19 April 2005 Resolved
Renew/repair high water bilge alarms in lazarett and engine room in accordance with 46 CFR 182.53.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Resolution: High water alarms were replaced with new ones.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 April 2005 Resolved
Remove excess oil from engine room bilge as required by 46 CFR 176.830.
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 11 May 2005
Resolution: Oil in engineroom was removed.
Documentation › Logs/Records › Drug Test Records
Issued 24 May 2004 Resolved
Provide proof of drug testing enrollment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2004
Resolved 28 May 2004
Resolution: Proof of drug testing program was presented to inspector.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 May 2004 Resolved
Make all deck hatches watertight IAW 46 CFR 171.124
Action required: 705 - Other - as specified
Due 24 May 2004
Resolved 28 May 2004
Resolution: Made all deck hatches watertight
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 May 2004 Resolved
Provide retro reflective tape for two adult PFD's IAW 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2004
Resolved 28 May 2004
Resolution: Installed retro reflective on PFD''s
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 24 May 2004 Resolved
Provide flame shields for racor filters
Due 24 June 2004
Resolved 28 May 2004
Resolution: installed flame shields for fuel filters
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 24 May 2004 Resolved
Provide means of engine shut down IAW 183.465
Due 24 June 2004
Resolved 24 May 2004
Resolution: provided means for MDE shutdown
Operations/Management › Equipment Service/Testing
Issued 24 March 2004 Resolved
Replace expire EPIRB battery. Vessel limited to lakes, bays and sounds until corrected. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Resolved 24 March 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 March 2004 Resolved
Replace corroded fire extinguisher and bracket in engine room (discharged).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2004
Resolution: Received fax copy of purchase invoice for fire extinguisher.
Lifesaving › Buoyant Apparatus
Issued 24 March 2004 Resolved
Replace weak link on life floats with Coast Guard approved links. Vessel limited to lakes, bays and sounds until corrected.
Action required: 705 - Other - as specified
Resolved 1 April 2004
Lifesaving › Buoyant Apparatus
Issued 24 March 2004 Resolved
Attach oars to life floats with lanyards and stencil with vessel name. Vessel limited to lakes, bays and sounds until corrected.
Action required: 705 - Other - as specified
Resolved 1 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 March 2004 Resolved
Service all fire extinguishers prior to May 2004 (include Fire Boy System in e/r). LEGACY COMPONENT DESC: Service
Due 31 May 2004
Resolved 1 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2004 Resolved
Life floats are inaccessible from the main deck. Provide a proposal for access to the life float stowage area. Vessel limited to lakes, bays and sounds until corrected.
Action required: 705 - Other - as specified
Resolved 1 April 2004
Lifesaving › Buoyant Apparatus
Issued 24 March 2004 Resolved
Install approved brackets for float lights on life floats. Vessel limited to lakes, bays and sounds until corrected.
Action required: 705 - Other - as specified
Resolved 1 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2004 Resolved
Install guards over engine pulleys. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 24 April 2004
Resolved 1 April 2004
Electrical › Electrical Distribution System (service)
Issued 24 March 2004 Resolved
Install covers over exposed electrical connections: circuit breaker on aft e/r bulkhead, lugs on main battery bus bar, and battery charger connections.
Due 24 April 2004
Resolved 1 April 2004
Engineering › Generator (propulsion-electric)
Issued 24 March 2004 Resolved
Battery boxes are not permanently mounted. Mount boxes and brace batteries from shifting. LEGACY COMPONENT DESC: Battery
Due 24 April 2004
Resolved 1 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2004 Resolved
"A" frame for trawling net needs to be more substantially braced. Provide proposal for "A" frame bracing.
Due 24 April 2004
Resolved 1 April 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 March 2004 Resolved
Replace pipe hanger on hoses inboard of stbd engine with permanent bracket.
Due 24 April 2004
Resolved 1 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 March 2004 Resolved
Replace all expire medicine in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 24 April 2004
Resolved 1 April 2004
Operations/Management › Navigation Safety
Issued 24 March 2004 Resolved
Provide tidal current table or extracts from the publication. 46 CFR 184.420(b) LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 24 April 2004
Resolved 1 April 2004
Operations/Management › Equipment Service/Testing
Issued 24 March 2004 Resolved
Register EPIRB prior to 30APR04. LEGACY COMPONENT DESC: EPIRB
Due 30 April 2004
Resolved 1 April 2004
Construction/Loadline › Penetrations
Issued 24 March 2004 Resolved
Seal bulkhead penetrations between rudder room and e/r.
Due 24 April 2004
Resolved 1 April 2004
Stability › Watertight Integrity
Issued 24 March 2004 Resolved
Replace gasket on hatch for rudder room.
Due 24 April 2004
Resolved 1 April 2004
Electrical › Electrical Distribution System (service)
Issued 24 March 2004 Resolved
Re-wire or remove dead end wires under wheelhouse console. LEGACY COMPONENT DESC: Wiring
Due 24 April 2004
Resolved 1 April 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 March 2004 Resolved
Replace inoperable tachometer for port engine in wheelhouse.
Due 24 April 2004
Resolved 1 April 2004
Communications › Radio Communications
Issued 22 July 2003 Resolved
Provide updated FCC operators license, FCC Station license, and FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 4 September 2003
Resolution: FCC Safety Certificate provided (others not required).
Documentation › Markings/Placards
Issued 22 July 2003 Resolved
Post emergency broadcast placard in accordance with 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 4 September 2003
Resolution: Emergency broadcast placard posted.
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 July 2003 Resolved
Provide Coast Guard approved first aid kit or equivalent.
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 July 2003 Resolved
Provide 5 adult life jackets to bring to full compliance. Vessel is limited to 44 passengers until complete.
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Navigation › Collision/Grounding Avoidance
Issued 22 July 2003 Resolved
Paint side shields on navigation lights matt black. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Electrical › Electrical Distribution System (service)
Issued 22 July 2003 Resolved
Provide cover for light switch at enterance to engine room. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Electrical › Electrical Distribution System (service)
Issued 22 July 2003 Resolved
Remove dead end wires and wire nuts in engine room, inboard side of starboard engine. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Electrical › Electrical Distribution System (service)
Issued 22 July 2003 Resolved
Connect ground wire near starboard engine. LEGACY COMPONENT DESC: Grounding Conductor
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Lifesaving › Rigid Liferafts
Issued 22 July 2003 Resolved
Replace life floats to capacity of 50% of passengers. LEGACY COMPONENT DESC: Buoyant Material
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 19 September 2003
Electrical › Electrical Distribution System (service)
Issued 28 April 2003 Resolved
Provide proper wire hangers for engine room wiring (no wire ties). LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 13 August 2003
Lifesaving
Issued 23 April 2001 Resolved
Vessel restricted to within 3 miles of land until approved hydro static release is provided for EPIRB.
Condition: Unknown
Due 24 May 2001
Resolved 22 July 2003
Resolution: Cleared by CORMS Act# 1781908.
Lifesaving
Issued 30 May 2000 Resolved
1. REPLACE/REPAIR INOP LIFE RING STROBE LIGHT._x001C_ _x001C_ 2. REPLACE/REPAIR INOP LIFE FLOAT STROBE LIGHT.
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000
Lifesaving
Issued 30 May 2000 Resolved
MAKE LIFE-FLOATS READY FOR INSPECTION. (REMOVE FROM OVERHEAD CANOPY)
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000
Engineering
Issued 30 May 2000 Resolved
ADJUST STARBOARD SIDE EMERGENCY FUEL SHUTOFF VALVE FOR PROPER OPERATION.
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000
Accommodation/Occupational Safety
Issued 30 May 2000 Resolved
REPLACE SMALL BROKEN PILOT HOUSE WINDOW. (PORT SIDE)
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000
Lifesaving
Issued 22 June 1999 Resolved
PROCURE 6 ORANGE SMOKE FLARES PRIOR TO VENTURING FURTHER THAN LAKES, BAYS AND SOUNDS.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Fire Fighting
Issued 22 June 1999 Resolved
INSTALL PROPER INSULATION IN ENGINEROOM OVRHEAD IAW Q SPECS.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Fire Fighting
Issued 22 June 1999 Resolved
REPAIR HALON SYSTEM IN ENGINEROOM AS ORIGINAL AND AS PER 46 CFR 181.400.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Lifesaving
Issued 22 June 1999 Resolved
PROVE VESSEL IS ARRANGED, EQUIPPED AND MANUEVERABLE TO RECOVER A HELPLESS PERSON FROM THE WATER.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Lifesaving
Issued 27 April 1998 Resolved
PROVIDE,INSTALL, AND REGISTER (1) FCC TYPE ACCEPTED CATEGORY I 406 MHZ EPIRB, INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE I.A.W. 46CFR180.15(i), 180.64, AND PROVIDE TESDT LOG AS PER 185.728. VESSEL RESTRICTED TO LAKES BAYS AND SOUNDS UNTIL EPRIB INSTALLED.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Electrical
Issued 26 August 1997 Resolved
Replace electrical distribution panals with proper marine grade panals as per 46 CFR 183.330.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Electrical
Issued 26 August 1997 Resolved
Replace all wire not approved for marine application, and correct all jury rigging in electrical system with acceptable marine practice as per 46 CFR 183.340.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Electrical
Issued 26 August 1997 Resolved
Replace all plastic wire ties with metal ties as per 46 CFR 183.340.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Electrical
Issued 26 August 1997 Resolved
Properly label all electrical distribution panels as per 46 CFR 183.220.
Condition: Unknown
Due 3 October 1997
Resolved 3 October 1997
Construction/Loadline
Issued 26 August 1997 Resolved
Lock sewage overboard valve closed while in port as per 46 CFR 176.818.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Documentation
Issued 26 August 1997 Resolved
Initiate and maintain vessel training log as per 46 CFR 185.420.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Post COI, Stability letter, Lifejacket Placard, Emergency Broadcast Placard.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Store emergency distress signals in proper container as per 46 CFR 180.68.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Outfit, stow and maintain vessel lifefloat as per 46 CFR176.180.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Provide CG Approved water lights for all PFD's on board as per 46 CFR 180.75.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Clean reflective tape on all PFD's as per 46 CFR 185.604.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Provide vessel with 52 adult PFD's as per 46 CFR 180.71.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Properly oufit and stow vessel lifering as per 46 CFR180.70.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Properly outfit vessels first aid kit as per 46 CFR 160.041.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Fire Fighting
Issued 26 August 1997 Resolved
Inspect, tag and maintain vessels fire extinguishers as per 46 CFR 181.500.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Fire Fighting
Issued 26 August 1997 Resolved
Prove proper operation of vessel fire and bilge pump as per 46 CFR 181.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Lifesaving
Issued 26 August 1997 Resolved
Provide public address system for vessel as per 46 CFR 184.610.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Accommodation/Occupational Safety
Issued 26 August 1997 Resolved
Properly seal MSD tank as per 46 CFR 176.818.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Navigation
Issued 26 August 1997 Resolved
Provide all proper charts and pubs required for operation as per 46 CFR 184.420.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Navigation
Issued 26 August 1997 Resolved
Install flatback backgrounds on all navigation lightd as per 46 CFR 183.420.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Navigation
Issued 26 August 1997 Resolved
Provide light for compass as per 46 CFR 184.402.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Engineering
Issued 26 August 1997 Resolved
Label "FUEL EMERGENCY SHUTOFF VALVES" as per 46 CFR 176.804._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Construction/Loadline
Issued 26 August 1997 Resolved
Prove proper operation of all battery operated bilge pumps as per 46 CFR 176.804.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Construction/Loadline
Issued 26 August 1997 Resolved
Install and prove proper operation of all high level bilge alarms as per 46CFR 182.530.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Construction/Loadline
Issued 26 August 1997 Resolved
Clean all oil from bilges as per 46 CFR 176.830.
Condition: Unknown
Due 26 August 1997
Resolved 3 October 1997
Construction/Loadline
Issued 26 August 1997 Resolved
Properly plug all transverse bulkhead penetrations as per 46 CFR 170.310.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Construction/Loadline
Issued 26 August 1997 Resolved
Install lanyards on all hatch covers as per 46 CFR179.360.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Navigation
Issued 26 August 1997 Resolved
Replace both steering system hoses as per 46 CFR 176.800.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Engineering
Issued 26 August 1997 Resolved
Prove proper operation of engine starts and stops from bridge, remove all jury rigs from engine control system, properly secure both main engine heatexchangers, prove operation of engine gauges on the bridge, repair starboard packing gland, install rotating machinery guards.
Condition: Unknown
Due 26 August 1997
Resolved 2 October 1997
Engineering
Issued 26 June 1996 Resolved
Replace flame screens in fuel tank vent with 30/30 mesh screens.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Lifesaving
Issued 26 June 1996 Resolved
Provide 6 red flares and 6 orange smoke signals.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Fire Fighting
Issued 26 June 1996 Resolved
Install nozzle on firefighting hose.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Lifesaving
Issued 26 June 1996 Resolved
Outfit both lifefloats acording to 46 CFR Part 180.10-1 before getting vessel underway.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Fire Fighting
Issued 26 June 1996 Resolved
Provide portable firefighting pump before getting underway.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Fire Fighting
Issued 26 June 1996 Resolved
Have engineroom halon bottle inspected.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Electrical
Issued 5 October 1995 Resolved
Repair stern light fixture.
Condition: Unknown
Due 5 October 1995
Resolved 10 October 1995
Documentation
Issued 5 October 1995 Resolved
Provide up to date Certificate of Documentation.
Condition: Unknown
Due 5 October 1995
Resolved 10 October 1995
Electrical
Issued 5 October 1995 Resolved
Provide covers for battery boxes and clean boxes.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Engineering
Issued 5 October 1995 Resolved
Repair pilothouse main engine shutdowns.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Lifesaving
Issued 24 June 1993 Resolved
POST EMERGENCY CHECK-OFF PROCEDURES PRIOR TO GETTING UNDERWAY FOR HIRE.
Condition: Unknown
Due 24 June 1993
Resolved 28 June 1993
Construction/Loadline
Issued 24 June 1993 Resolved
SEAL PIPING AND CABLE PENETRATIONS IN FORWARD AND AFTER BULKHEADS OF MSD COMPARTMENT.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Lifesaving
Issued 24 June 1993 Resolved
PROVIDE ADEQUATE BOUYANT APPARATUS PRIOR TO SAILING FOR HIRE ON COASTWISE ROUTE.
Condition: Unknown
Due 16 July 1993
Resolved 19 July 1993
Construction/Loadline
Issued 24 June 1993 Resolved
RENEW FAILED GASKET ON LAZERETTE SCUTTLE.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Engineering
Issued 10 June 1993 Resolved
Replace starboard propeller._x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Construction/Loadline
Issued 10 June 1993 Resolved
Make permanent repairs to fractured butt seams at bottom chine._x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Engineering
Issued 26 June 1991 Resolved
REMOVE ALL PETCOCKS FROM FUEL FILTER IN ENGINEROOM.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Engineering
Issued 26 June 1991 Resolved
INSTALL BACKING PLATE ON HYD. CYLINDER MOUNT.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Fire Fighting
Issued 26 June 1991 Resolved
SERVICE HALON BOTTLE
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Navigation
Issued 26 June 1991 Resolved
PROVIDE AND INSTALL MAST HEAD LIGHT IN ACCORDANCE WITH 72 COLREGS.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Navigation
Issued 26 June 1991 Resolved
REMOUNT ANCHOR LIGHT.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991

Ownership record