Records from 2010 to 2025. Most recent: inspection, 17 July 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)30.0 ft × 12.0 ft × 4.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGALAIDI CORP · TAMUNING, GUAM · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portINARAJAN, GU
Trade endorsementsRegistry
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Net Ton
6 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
12 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
17 July 2025
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8187743
5 September 2024
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7990823
11 June 2023
Annual Inspection · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7711735
24 May 2023
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7715448
4 November 2022
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7589293
25 October 2021
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7338856
1 August 2020
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7021863
1 April 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6945392
11 September 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6814545
25 November 2018
Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6586257
29 November 2017
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6315272
21 November 2016
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6045648
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 01 Adult life jacket's foam was un-serviceable. Replace in kind. Passenger count lowered to 43.
46 CFR 180.71(a)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2025
Resolution: New life jacket added to vessel. Labelled with vessel name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942.
All the flexible piping used between engines and portable fuel tanks are SAE J1527, which is for recreational use only. Replace with SAE J1942 flexible hose.
46 CFR 182.720(e)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2025
Resolution: SAE J1942 hoses installed on both engines and both fuel tanks.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 July 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
Maintain log of drills.
46 CFR 185.520(a)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2025
Resolution: Log book created and kept in office.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 4 November 2022
Resolved
Official number in port side void is missing a number and peeling.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 November 2022
Resolved
Retroreflective tape for 5 adult life jackets needs to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 October 2021
Resolved
Gauges to indicate engine revolutions per minute (RPM) must be provided for all propulsion engines installed in the vessel. Vessel does not have operational RPM gauges. 46CFR182.410
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 4 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 October 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Replace four adult life jackets that are beyond serviceable. Vessel is restricted to a total of 42 adults. 46CFR180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 28 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2019
Resolved
Rejected 7 adult and 1 child type 1 life jackets
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2018
Resolved
Stbd side fuel line was found to be rotted and in need of replacement. 46 CFR 182.15-40(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 22 January 2019
Resolution: Fuel line replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2018
Resolved
Independent fuel tanks found to be cracked an din need of replacement. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 22 January 2019
Resolution: Fuel tanks replaced with new tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2018
Resolved
Vessel does not have strainers or drip pand installed. 46 CFR 182.15-40
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 22 January 2019
Resolution: Strainers and drip pans installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2018
Resolved
Wiring for the bilge pump is hanging and not properly secured. 46 CFR 111.01-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 22 January 2019
Resolution: Wires secured properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018
Resolved
16 of 46 lifejackets were wasted or torn and removed from service. 46 CFR 176.808 (b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 November 2018
Resolved 27 November 2018
Resolution: Company had enough extra lifejackets in storage to replace ones taken out of service.
Communications › Alarms/Indicators › High Water Alarm
Issued 21 November 2016
Resolved
Install starboard side high water alarm with marine service screws instead of epoxy.
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 21 November 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 November 2016
Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 21 November 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 November 2016
Resolved
Properly mark number and type of life jackets at storage locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 November 2016
Resolved
Provide new retro material on 04 child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 28 November 2016
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 November 2016
Resolved
Provide donning placards for each type of life jacket carried on board.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 28 November 2016
Electrical › Electric Supply System (service) › Cable
Issued 21 November 2016
Resolved
Properly secure the newly installed wiring for the starboard high water alarm.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Documentation › Markings/Placards › Vessel Number (state)
Issued 21 November 2016
Resolved
Mark stern of vessel with the vessel name and hailing port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Documentation › Markings/Placards › Garbage Placard
Issued 21 November 2016
Resolved
Provide updated MARPOL V placard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 1 December 2016