Records from 2002 to 2009. Most recent: inspection, 8 December 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
8 December 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3646379
1 November 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3365622
3 July 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2981861
28 September 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2787050
29 June 2006
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2696013
27 October 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2468041
4 June 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2088396
25 November 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1954264
30 August 2002
Plan Review "T" Boat · Initial Certification · Simplified Stability Test · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1668778
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 September 2006
Resolved
Port engine did not shut down after testing auto shut down. Show proper operation of fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2006
Resolution: Engine shut down system had a blown fuse which did not allow the engine to be shut down. The fuse was replaced and shutdown was witnessed operational on todays date.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 September 2006
Resolved
Provide operational waterlight for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2006
Resolved 10 October 2006
Resolution: Light replaced with new unit.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 June 2006
Resolved
Deck rail on starboard bow of main deck has complete fracture of weld and bottom rail course on aft starboard quarter of second deck has complete fracture of weld. have both areas welded.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 24 July 2006
Resolution: Received statement from owner that hand rails have been welded.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 June 2006
Resolved
Attach aft railing posts (three total) on second deck to the deck.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 24 July 2006
Resolution: Received a statement from vsl rep that rails have been attached.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 October 2005
Resolved
Post COI in a conspicuous place.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 18 December 2005
Resolution: Posted COI in a conspicuous place.
Documentation › Certificates/Documents › Stability Letter
Issued 27 October 2005
Resolved
Post stability letter in conspicuous place.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 18 December 2005
Resolution: Posted stability letter in conspicuous place.
Lifesaving › Lifefloat › Lifeline
Issued 27 October 2005
Resolved
Replace grab lines on both life floats.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 18 December 2005
Resolution: Replaced grab lines on both life floats.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 October 2005
Resolved
Provide a corrosion resistant clip on ring buoy prior to operating at night.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 18 December 2005
Resolution: Provided a corrosion resistant clip on ring buoy prior to operating at night.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 October 2005
Resolved
Provide 3/8" inch line on water light on both life floats and ring buoy.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 18 December 2005
Resolution: Provided 3/8" inch line on water light on both life floats and ring buoy.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 October 2005
Resolved
Repair anchor light prior to operating at night.
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 18 December 2005
Resolution: Repaired anchor light prior to operating at night.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 October 2005
Resolved
Issued letter of warning for failure to ensure periodic inspection was conducted within 90 days of anniversary date on COI, August, 30.
Action required: 705 - Other - as specified
Due 27 October 2005
Resolved 27 October 2005
Resolution: Conducted periodic exam.
Accommodation/Occupational Safety › Cooking Systems
Issued 25 November 2003
Resolved
Provide sea rails on galley range.
Due 20 December 2003
Resolved 2 February 2004
Documentation
Issued 25 November 2003
Resolved
Provide 46 CFR Subchapter T
Due 20 December 2003
Resolved 28 November 2003
Lifesaving › Lifebuoys
Issued 25 November 2003
Resolved
Replace hand line on ring lifebuoy
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2003
Resolved 29 November 2003