MAURY USCG vessel records Sign in
← All vessels

IBIZA

IBIZA is a 1990 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1990, most recently in April 2025, along with 122 deficiencies and 2 operational controls.

Records from 1990 to 2025. Most recent: inspection, 8 April 2025.

Built
1990
Last inspected
8 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK2114
338815
Flag
UNITED STATES
368032550
Maury page id
psix-338815

Inspections, by type

…with no type recorded4
Years with a record 30 calendar years (1990–2025)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)66.6 ft × 17.9 ft × 5.3 ft
Registered tonnagegross 92 / net 27
ITC dimensions (L × B × D)66.6 ft × 17.9 ft × 5.3 ft
ITC tonnagegross 92 / net 27
BuilderMID-CITY & SKIPPERLINER · LA CROSSE WI, UNITED STATES · built 1990
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMARINA DEL REY, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Convention (Subpart B), Net Ton
92 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK2114MMSI 368032550 · active · compulsorily equipped · granted 12 April 2018, expires 12 April 2028
WDE9350MMSI 367416330 · expired · compulsorily equipped · granted 24 June 2009, cancelled 24 August 2019 · licensed under a name not among this hull’s recorded names (not shown)
WBY8062MMSI not assigned · expired · compulsorily equipped · granted 29 May 1998, cancelled 25 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

8 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075353
17 April 2023 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7628249
24 January 2023 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7522512
29 March 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7405531
11 August 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7284238
3 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188107
23 March 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7161311
23 March 2021 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7163184
7 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6977416
7 August 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6776269
17 April 2019 Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6648871
19 April 2018 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6393724
8 May 2017 Deficiency Check · Plan Review "T" Boat · Drydock Exam · Examination of Repairs · Construction Oversight · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6147777
27 July 2012 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4411698
29 June 2012 Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4347726
28 September 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3856364
7 January 2010 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3660201
15 July 2009 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3536364
15 July 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3537276
9 June 2008 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3231769
16 April 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3185427
2 April 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3176770
12 July 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2989874
11 July 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2991580
30 May 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2940160
18 May 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2934006
12 May 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2640899
7 April 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2622491
28 April 2005 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2338995
7 December 2004 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2347764
27 October 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1935577
15 April 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1771517
13 October 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1689325
14 August 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1661109
7 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366637
3 April 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399586
12 June 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369749
6 June 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 819516
13 April 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412089
15 April 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416870
26 February 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397094
5 November 1998 Deadweight Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440079
14 April 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421488
23 November 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 776371
21 May 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1104442
14 April 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411445
28 February 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407834
17 April 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367703
3 January 1996 Type not recorded
No type recorded · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 677005
3 January 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 716305
27 April 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 865966
15 February 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1162937
19 August 1994 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394173
13 May 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859654
3 May 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168567
13 July 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155600
4 May 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1152145
13 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1138114
2 January 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1140903
3 December 1992 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 961965
7 May 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 943098
22 January 1992 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1259124
17 May 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1001306
17 April 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1234495
12 April 1990 Plan Review "T" Boat · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1221482

Deficiency record · 122

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 April 2025 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Master was unable to provide evidence of a valid U.S. Coast Guard issued medical certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 14 April 2025
Resolution: O/O provided image of certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Master was unable to provide evidence of a valid Radiotelephony certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 1 May 2025
Resolution: Valid Comms Act Radiotelephony Cert
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025 Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. MI observed numerous life jackets with deteriorated or missing retro-reflective tape.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 April 2025
Resolved 8 April 2025
Resolution: The operator replaced the retroreflective tape for the necessary amount of lifejackets that had the retroreflective tape peeling off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 April 2023 Resolved
46 CFR 184.420: Charts and nautical publicationsAs appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. MI observed vessel was missing the following pubs: Light list, Tide Tables, Tidal current tables and current charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 25 April 2023
Resolution: MI observed publications/charts onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 April 2023 Resolved
184.710 First-aid kits. A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MI observed missing items in First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 25 April 2023
Resolution: Owner purchased new First Aid, USCG approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2022 Resolved
AN EXPOSED HAZARD, SUCH AS GEARS OR ROTATING MACHINERY, MUST BE PROPERLY PROTECTED BY A COVER, GUARD, OR RAIL. USCG MARINE INSPECTOR OBSERVED MISSING ROTATING MACHINERY GUARD ON PORT ENGINE. INSTALL MACHINERY GUARD ON PORT ENGINE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 27 April 2022
Resolution: Vessel fabricated and installed machinery guard.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 August 2021 Resolved
AIS Class A device, The following vessels must have on board a properly installed, operational USCG Type approved AIS Class A device: A self-propelled vessel of 65 feet or more in length, engaged in commercial service. Vessel does not have an operation USCG Type approved AIS Class A device onboard the vessel. Vessel required appropriate operable AIS system to be installed onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 29 October 2021
Resolution: Verified AIS was properly functioning and device installed was a Class A.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 May 2021 Resolved
On a vessel more than 65', must have a fire pump of 60psi/50gpm. Pump must be fitted with a gauge. Fire pump missing gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 19 May 2021
Resolution: Pressure gauge installed and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021 Resolved
A suitable hull strainer must be installed in the circulating raw water intake line. Strainer is installed but not mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 19 May 2021
Resolution: Strainer mounted properly. All appeared SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2020 Resolved
All vessels 26ft and great shall be provided with bilge lines and bilge suction. Vessel could not dewater the forward compartment. Prove proper operation to the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2020
Resolved 7 July 2020
Resolution: Witnessed proper operation of bilge suction in all spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2020 Resolved
A visual and audible alarm must be provided at operators station. Fwd bilge compartment visual alarm was not operational. Demonstrate proper operation to the attending marine inspector
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 30 July 2020
Resolution: Witnessed proper operation of audio and visual alarm bilge alarms.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 August 2019 Resolved
SHUTOFF VALVE AT FUEL TANK SHALL BE OPERABLE FROM OUTSIDE THE TANK COMPARTMENT. SHUTOFF VALVE NOT OPERABLE FROM OUTSIDE SPACE. PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2019
Resolution: Vessel renewed valves and proved proper operation of the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2019 Resolved
ALL VESSELS OF 26FT IN LENGTH AND OVER SHALL BE PROVIDED WITH INDIVIDUAL BILGE LINES AND BILGE SUCTIONS FOR EACH WATERTIGHT COMPARTMENT. BILGE SUCTION IN FORWARD AC PUMP COMPARTMENT IS INOPERABLE. PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2019
Resolution: Vessel proved proper operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 August 2019 Resolved
Every vessel subject to part III title III of the communications act must have a detailed inspection of the radio installation by an FCC licensed technician in accordance with 80.54 once every 5 years. Vessel was unable to produce radiotelephony certificate. Prove presence of valid certificate or acquire via scheduling inspection with licensed FCC technician.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Vessel provided Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 August 2019 Resolved
A VESSEL MUST AFFORD ADEQUATE PRECAUTION AGAINST HAZRADS THAT MIGHT ENDANGER PERSONS BEING TRANSPORTED. VESSEL DID NOT HAVE ANY MEANS OF RECOVERING MAN OVERBOARD IN TIMELY AND EFFICIENT MANNER. RECOVERY AREA HAS 3+ FEET OF FREEBOARD. PROVIDE SATISFACTORY MEANS OF RECOVERING MAN OVERBOARD.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 12 September 2019
Resolution: Vessel provided satisfactory means for recovery of man overboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 August 2019 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel exceeded 3 month interval on 19JUL2019. Vessel is required to undergo satisfactory annual inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2019
Resolved 30 August 2019
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 19 April 2018 Resolved
PROVIDE PERMANENT DRAFT MARKS AT EACH END OF THE VESSEL BY NEXT DRYDOCK DATE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. (CITE: 46 CFR 185.30-3 HULL MARKINGS)
Condition: Invalid
Due 31 July 2019
Resolved 18 April 2019
Resolution: Owner placed draft marks on hull to the satisfaction of the MI.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 April 2018 Resolved
Provide lanyard to attach ring buoy waterlight to ring buoy.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 April 2018
Resolved 19 April 2018
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 April 2018 Resolved
Conduct a satisfactory man-overboard drill proving proficiency and crew knowledge.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 April 2018
Resolved 19 April 2018
Resolution: Conducted satisfactory 2nd MOB Drill.
Engineering › Bilge Water Management System › Pump
Issued 19 April 2018 Resolved
Prove proper operation of port engine attached bilge pump.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 April 2018
Resolved 19 April 2018
Resolution: See Narrative of MISLE ACTIVITY ID#6147777: As noted by the inspector on 4-13-2018, the pump did not operate. The impeller on the port engine attached pump was replaced and conducted satisfactory operatonal test on 19APR2018.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2018 Resolved
Provide a battery in the ring buoy water-light, and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 19 April 2018
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 July 2012 Resolved
Vessel may not operate with passengers for hire until a credit dry-dock exam has been completed by USCG Marine Inspectors. 46CFR176.600(c)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2013
Electrical › Electrical Distribution System (service) › Cable
Issued 29 June 2012 Resolved
Remove SJOOW cable from distribution panel. 46 CFR183.340
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 April 2018
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 29 June 2012 Resolved
Provide blank or spare breaker for open slot in electrical distribution panel. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 19 April 2018
Electrical › Electric Supply System (service) › Cable
Issued 29 June 2012 Resolved
Provide repair plan for shore connection electrical distribution. 46 CFR 183.310
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 April 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2012 Resolved
Prove proper operation of DC source and distribution system. 46 CFR 183.330
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 April 2018
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 September 2010 Resolved
Install circuit breaker blank in after 110V panel board located in main passageway closet.
Due 5 October 2010
Resolved 1 October 2010
Resolution: O/O provided picture.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 September 2010 Resolved
Install cover on receptacle box in way of starboard side canopy rope lighting.
Due 5 October 2010
Resolved 1 October 2010
Resolution: O/O provided picture.
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 September 2010 Resolved
Replace inoperative fuel shut off valves at fuel tank located in lazarette.
Due 5 October 2010
Resolved 1 October 2010
Resolution: O/O provided picture.
Documentation › Logs/Records › Drug Test Records
Issued 15 July 2009 Resolved
Company could not provide an exceptable proof of five-panel testing as required by 46 CFR 16.113.
Due 14 August 2009
Resolved 31 July 2009
Resolution: Company provide valid proof of five-panel testing.
Documentation › Logs/Records › Drug Test Records
Issued 15 July 2009 Resolved
Company could not provide results/exemptions for pre-employment testing prior to working in a safety sensative position as required by 46 CFR 16.210.
Due 15 August 2009
Resolved 31 July 2009
Resolution: Company e-mailed copies of employee pre-employment test.
Documentation › Logs/Records › Drug Test Records
Issued 15 July 2009 Resolved
Pre-employment documentation has not been kept for entire employment period as required by 46 CFR 16.210.
Due 15 August 2009
Resolved 31 July 2009
Resolution: Company e-mailed copies of employee pre-employment test.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Company has signed up with a consortium. Both the company and consortium receive pre-employment results.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Company did not have records of pre-employments as required by 46 CFR 16.210.
Due 5 July 2008
Resolved 24 September 2010
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 5 July 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium is currently using a computer based selection program for the company''s random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Statistically based method not currently being used to determine when random testing takes place as required by 46 CFR 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium is currently using a computer based selection program for the company''s random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Company and consortium drafted a list of all safety-sensative personnel to be tested.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: EAP policy posted on all vessels.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium provided 2 hours worth of EAP training to company''''s supervisors.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Employer does not have a Substance Abuse Professional (SAP) name and contact information as required by 49 CFR 40.287.
Due 5 July 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: EAP hotline phone number posted with EAP policy on all vessels.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008 Resolved
MIS form not submitted by March 15 s required by 46 CFR 16.500
Due 5 July 2008
Resolved 3 July 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 April 2008 Resolved
Provide correct number of portable extinguishers on board IAW 46CFR 181.500(a). Properly service and mount in respective area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Construction/Loadline › Structures › Superstructure
Issued 2 April 2008 Resolved
Renew broken windows.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Construction/Loadline › Structures › Superstructure
Issued 2 April 2008 Resolved
Repair bulwark on STBD side aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2008
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 9 July 2007 Resolved
Mark vessel IAW 46 CFR 185.602 (a) & 46 CFR 67.123.
Due 27 August 2007
Resolved 17 April 2008
Construction/Loadline › Structures › Superstructure
Issued 9 July 2007 Resolved
Replace 2 Identified cracked windows main deck portside.
Due 12 August 2007
Resolved 20 August 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 9 July 2007 Resolved
Properly install fluorescent light fixture in liquor stores IAW 46 CFR 183.410.
Due 12 August 2007
Resolved 20 August 2007
Resolution: Removed fixture.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 July 2007 Resolved
Properly install electrical outlet box outside, portside fwd IAW 46 CFR 183.340.
Due 12 August 2007
Resolved 20 August 2007
Fire Fighting › Fire Pumps › Power Source
Issued 9 July 2007 Resolved
Install guard for port main engine fire pump IAW 46 CFR 177.960.
Due 12 August 2007
Resolved 20 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2007 Resolved
Properly deadend all identified wires and provide two outlet covers under steering console.
Due 12 August 2007
Resolved 20 August 2007
Documentation › Manuals/Policy Documentation › First Aid Manual
Issued 9 July 2007 Resolved
Provide onboard 50% CPR/First Aid training for Master and crew.
Due 27 August 2007
Resolved 17 April 2008
Communications › Internal Communications System › Portable Radios
Issued 9 July 2007 Resolved
Demonstrate proper communication between operator and crew, during shipboard evolutions (i.e.: Drills, Daily Ops).
Due 12 August 2007
Resolved 20 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2007 Resolved
Properly mount and support all identified wires and outlet covers in sewage space and storage room space, IAW 46 CFR 183.340.
Due 12 August 2007
Resolved 20 August 2007
Construction/Loadline › Hull › Bottom Plating
Issued 30 May 2007 Resolved
Provide repair proposal and make repairs to hull on the starboard side bow in way of pinhole, and to hull in way of wastage in forepeak between the first longitudinals port and starboard from the keel in way of collision bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2007
Construction/Loadline › Hull › Bottom Plating
Issued 30 May 2007 Resolved
In the sewage space, replace bottom hull plate from the portside shell aft to the fourth longitudinal in between the aft bulkhead and the first frame forward. In addition, replace wasted section of aft bulkhead near the port sideshell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 30 May 2007 Resolved
Properly adjust intake valve to the auxiliary pump so it seats properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 18 May 2007 Resolved
Vessel restricted from carrying passengers for hire until a credit hull exam and new certificate of inspection is completed by an attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2007
Resolved 20 August 2007
Engineering › Bilge Water Management System › Pump
Issued 12 May 2006 Resolved
Demonstrate operation of both required bilge pumps. This item must be demonstrated to the satisfaction of an attending marine inspector prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 17 May 2006
Personnel › Training › Search and Rescue
Issued 12 May 2006 Resolved
Demonstate a man-overboard drill using man-overboard retrievel equipment installed on vessel. This item must be corrected to the satisfaction of an attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 17 May 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 May 2006 Resolved
Provide emergency instructions. This item must be corrected to the satisfaction of an attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 17 May 2006
Lifesaving › Rescue Boat › Carriage Requirement
Issued 12 May 2006 Resolved
Provide a rescue boat as per 46 CFR 180.210 or equipment and means to recover a helpless person from the water. This item must be corrected to the satisfaction of an attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 17 May 2006
Engineering › Compressed Air System (control) › Valve
Issued 12 May 2006 Resolved
Provide an operable relief valve for the air cylinder under the bridge console which relieves at no more than 125 psi. This item must be corrected to the satisfaction of an attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2006
Resolved 17 May 2006
Engineering › Sea-water System (primary cooling) › Pump
Issued 12 May 2006 Resolved
Properly mount the air conditioner condensor raw cooling water pump in the engine room.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 12 May 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 12 May 2006 Resolved
Properly wire the air conditioner raw cooling water water pump motor.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Electrical › Electric Supply System (service) › Battery Conductor
Issued 12 May 2006 Resolved
Install battery cut-off switches as per 46 CFR 183.380(i).
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 12 May 2006 Resolved
Provide properly sized cable to the navigation lights.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Electrical › Electrical Distribution System (service) › Fuse
Issued 12 May 2006 Resolved
Provide properly sized overcurrent protection for the bilge pump D.C. clutch.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 12 May 2006 Resolved
Provide a properly sized and designed electrical system for the 12VDC under console battery system under the pilothouse control console.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Fire Fighting › Nozzles › Type
Issued 12 May 2006 Resolved
Provide a proper type fire nozzle for both port and starboard fire hoses.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2007
Fire Fighting › Nozzles › Condition
Issued 12 May 2006 Resolved
Make the starboard fire hose nozzle operable.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 12 May 2006 Resolved
Provide a Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2007
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 May 2006 Resolved
Include entire crew in the drug testing program.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 May 2006 Resolved
Provide 156 adult lifejackets. The number of persons on-board is limited to the number of adult lifejackets carried.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 May 2006 Resolved
Provide a crew training record.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 17 May 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 12 May 2006 Resolved
Provide a single line electrical drawing for the battery and navigation lighting curcuits under the wheelhouse control console. When the drawing is approved, the system must be installed as per 46 CFR 183.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 April 2006 Resolved
Conduct annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2006
Resolved 17 May 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 December 2004 Resolved
Operator did not have proof of enrollment for all crew in approved drug testing program.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 21 December 2004
Resolution: Provided proof of enrollment for all crew members.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 December 2004 Resolved
Operator did not have training records of abandon ship or fire fighting drills available.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 December 2004
Resolved 21 December 2004
Resolution: Logs provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2004 Resolved
Bilge high level alarm for the mid (storage) compartment and a visual/audible alarm at the operating station.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 21 December 2004
Resolution: Bilge high level alarm for the mid (storage) compartment and visual/audible alarm installed and operable.
Documentation › Certificates/Documents
Issued 27 October 2003 Resolved
Post Certificate of Inspection under glass in a conspicuous place. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2003
Resolved 27 October 2003
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction
Issued 27 October 2003 Resolved
Throw lifering during man overboard drill. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 27 October 2003
Resolved 27 October 2003
Resolution: Corrected on the spot.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 October 2003 Resolved
Mount emergency instructions at operating station.
Action required: 705 - Other - as specified
Due 27 October 2003
Resolved 27 October 2003
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service)
Issued 14 August 2002 Resolved
Rewire exterior outlet on port bow with approved UL boat cable. LEGACY COMPONENT DESC: Outlet Box
Due 14 September 2002
Resolved 12 September 2002
Resolution: [name withheld] called and stated that the rewiring was completed.
Fire Fighting
Issued 14 August 2002 Resolved
Re-service halon fire extinguisher stored in bar, as gauge reads low pressure. LEGACY COMPONENT DESC: Portable HALON fire ext.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2002
Resolved 15 August 2002
Resolution: Vessel rep faxed over report from servicing company stating gauge was replaced and extinguisher was properly charged.
Engineering › Bilge Water Management System
Issued 14 August 2002 Resolved
Install bilge high level alarms in engine room and lazarette, per 46 CFR 182.530. Until this item is cleared, crew must make hourly rounds while passengers are aboard.
Action required: 705 - Other - as specified
Due 14 October 2002
Resolved 13 October 2002
Resolution: Received fax from [name withheld] stating that bilge high level alarms in engine room and lazarette are installed and operating correctly.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 August 2002 Resolved
COI was expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2002
Resolution: Satisfactorily conducted COI exam; Issued COI.
Fire Fighting
Issued 7 May 2001 Resolved
Replace and test both fire hoses prior to operation with passengers.
Condition: Unknown
Due 3 November 2001
Resolved 3 November 2001
Unknown
Issued 7 May 2001 Resolved
Replace mooring spring line NLT 14 May 2001 to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 3 November 2001
Resolved 3 November 2001
Fire Fighting
Issued 13 April 2000 Resolved
Repair and prove proper operation of port main engine fire pump.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Fire Fighting
Issued 13 April 2000 Resolved
Lable aft electrical door indicating fire extinguisher is inside.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Fire Fighting
Issued 13 April 2000 Resolved
Mount fire extinguisher in galley.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Electrical
Issued 13 April 2000 Resolved
Provide approved plans and permanently wire new A/C fresh water pump.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Documentation
Issued 15 April 1999 Resolved
Display valid FCC Radio Safety Certificate.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Electrical
Issued 14 April 1998 Resolved
Provide light covers on 12 volt light in liquor locker and engine room.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Lifesaving
Issued 14 April 1998 Resolved
Post placard designating storage location and number of child PFD's.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Lifesaving
Issued 14 April 1998 Resolved
Provide ring buoy with retro reflective tape.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Navigation
Issued 14 April 1998 Resolved
Provide 46 CFR parts 166-199, Light Lists, Local Notice To Mariners and Tide Tables on vessel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Electrical
Issued 21 May 1997 Resolved
Complete wiring of the upper deck outlet and lighting circuit in accordancewith the provisions of subchapter "T". The circuit is to be tagged out andnot used until such time as a marine inspector has approved the installtion.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Fire Fighting
Issued 14 April 1997 Resolved
Hydro-test port side fire hose as per 46CFR176.810 or replace hose.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Electrical
Issued 14 April 1997 Resolved
Replace non-approved wire for upper passenger deck lighting and starboard side exterior lighting with cable of an approved size and type.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Engineering
Issued 28 February 1997 Resolved
Replace port cutlass bearing.
Condition: Unknown
Due 7 March 1997
Resolved 10 March 1997
Documentation
Issued 17 April 1996 Resolved
Initiate a random chemical testing program for all crew members.
Condition: Unknown
Due 10 May 1996
Resolved 22 May 1996
Construction/Loadline
Issued 17 April 1996 Resolved
Label bilge manifold._x001C_
Condition: Unknown
Due 10 May 1996
Resolved 22 May 1996
Navigation
Issued 17 April 1996 Resolved
update charts or provide maintain recent local notice to mariners
Condition: Unknown
Due 10 May 1996
Resolved 22 May 1996
Documentation
Issued 3 May 1994 Resolved
PROVIDE FCC MARINE RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Documentation
Issued 3 May 1994 Resolved
PROVIDE PROOF OF CONTINUED PARTICIPATION, AND OF RANDOM TESTING, IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 3 May 1994 Resolved
PROVIDE LABELING FOR CHILD PFD STORAGE.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 4 May 1993 Resolved
PROVIDE COMPASS DEVIATION CARD/TABLE IN ACCORDANCE WITH OFFICER IN CHARGE OF MARINE INSPECTIONS, LOS ANGELES-LONG BEACH, CA. MEMO DATED 27MARCH 1992.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 4 May 1993 Resolved
PROVE PROPER OPERATION OF INTERNAL COMMUNICATIONS AND PUBLIC ADDRESS SYSTEMS.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Lifesaving
Issued 4 May 1993 Resolved
PROPERLY LABEL PERSONAL FLOTATION DEVICE STOWAGE COMPARTMENT ON LOWER DECK.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Documentation
Issued 4 May 1993 Resolved
PROVIDE PROOF OF VALID FCC RADIOSTATION LICENSE CERTIFICATE.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 4 May 1993 Resolved
PROVE PROPER OPERATION OF FATHOMETER AND SPEEDOMETER.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 4 May 1993 Resolved
PROVIDE UPDATED/CORRECTED CHARTS AND PUBLICATIONS IN ACCORDANCE WITH OFFICER IN CHARGE OF MARINE INSPECTIONS, LOS ANGELES-LONG BEACH, CA. MEMO DATED 01 JUNE 1992.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Construction/Loadline
Issued 4 May 1993 Resolved
INSTALL DRAFT OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3 PRIOR TO COMPLETION OF THE NEXT ROUTINE DRYDOCKING.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Documentation
Issued 4 May 1993 Resolved
PROVIDE PROOF OF VESSEL MASTER, PIERRE DESMET, POSSESSING VALID MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Documentation
Issued 13 January 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 January 1993
Resolved 13 January 1993
Construction/Loadline
Issued 13 January 1993 Resolved
PROVIDE PROPER VENTILATION FOR THE FUEL OIL TANK COMPARTMENT/LAZARETTE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1993
Resolved 13 January 1993
Construction/Loadline
Issued 13 January 1993 Resolved
PROVIDE AT LEAST THREE INCHES OF COAMING ON THE PORT AND STARBOARD FORWARD_x001C_AND STARBOARD STERN DOORS ON THE MAIN DECK.
Condition: Unknown
Due 13 January 1993
Resolved 13 January 1993
Unknown
Issued 17 April 1991 Resolved
Provide proof of Documentation to the attending Coast Guard Marine Inspector.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Engineering
Issued 17 April 1991 Resolved
Provide a second self priming bilge pump.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.