Records from 1992 to 2009. Most recent: inspection, 2 December 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
2 December 2009
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3643607
22 January 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3393172
19 February 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3139692
10 January 2007
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2853860
15 February 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2550503
4 April 2005
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2326365
7 January 2005
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2275207
24 November 2004
Administrative Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2226471
31 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 773079
26 September 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1074831
14 May 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397644
24 July 2000
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1051721
9 May 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365792
25 January 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1436327
18 June 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1094672
10 May 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393159
1 June 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386306
12 January 1998
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400702
17 November 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1027193
19 May 1997
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388309
26 July 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1088604
20 June 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078457
10 June 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1405920
23 October 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1182321
26 June 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1190909
18 April 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164435
27 June 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420889
27 May 1994
Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861130
25 May 1994
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 859339
10 May 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1169750
9 May 1994
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1180924
25 March 1994
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166383
21 March 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165322
2 March 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867692
18 January 1994
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160970
28 October 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831910
22 October 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154255
24 September 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1158888
1 July 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846980
24 June 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843741
16 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842292
7 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142508
10 May 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1141991
29 December 1992
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 829770
7 December 1992
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1133137
28 October 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264951
19 September 1992
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957726
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 February 2008
Resolved
Install searails for cook top.
Action required: 705 - Other - as specified
Resolved 19 February 2008
Electrical › Electric Supply System (service) › Cable
Issued 19 February 2008
Resolved
Properly support electrical cables in fwd compartment and lazarrate.
Action required: 705 - Other - as specified
Resolved 19 February 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 January 2007
Resolved
Properly mark vessel's name on two liferings that have faded. In addition, provide proper length of lifeline to each lifering.
Action required: 705 - Other - as specified
Due 11 January 2007
Resolved 11 January 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 January 2007
Resolved
Properly dead end all identifed exposed wiring in engine room.
Action required: 705 - Other - as specified
Due 11 January 2007
Resolved 11 January 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2007
Resolved
Properly arrange port and stbd sidelights to meet requirements of 72 COLREGS.
Action required: 705 - Other - as specified
Due 11 January 2007
Resolved 5 February 2007
Fire Fighting › Fire Bucket › Availability
Issued 15 February 2006
Resolved
Vessel owner was only able to produce one fire bucket. Obtain onboard two (2) additional fire buckets as required by 46 CFR 181.610.
Due 15 February 2006
Resolved 15 February 2006
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 15 February 2006
Resolved
Found two wires in the lazarette, port side, that were not connected to any circuit and were not dead-ended. Either connect the wires to its applicable circuit or properly dead-end IAW 46 CFR 183.200.
Due 15 February 2006
Resolved 15 February 2006
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 23 February 2005
Resolved
Make engine room door fume tight and constructed of non-combustable material.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2005
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 23 February 2005
Resolved
Make fume tight the area aft of engine room that commmunicates with the lazzerette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 February 2005
Resolved
Properly connect and show proper operation of fuel oil shut-off valves from station at stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 February 2005
Resolved
Prove proper operation of fixed gass fire fighting system equipment shut downs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 23 February 2005
Resolved
Demonstrate vessel safety orientation.
Due 23 February 2005
Resolved 23 February 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 7 January 2005
Resolved
Mark all life preservers with vessel name.
Due 23 February 2005
Resolved 23 February 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 January 2005
Resolved
Provide on board and properly post the COD with owner and operator information corrected through the NVDC.
Due 23 February 2005
Resolved 23 February 2005
Documentation › Logs/Records › Drug Test Records
Issued 7 January 2005
Resolved
Prove that all employee's are enrolled in an approved drug testing program.
Due 23 February 2005
Resolved 23 February 2005
Navigation › Piloting/Steering › Marine Charts
Issued 7 January 2005
Resolved
Provide on board updated charts for the vessel operating area.
Due 23 February 2005
Resolved 23 February 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 January 2005
Resolved
Install corrosion resistant clip for water light attached to life ring.
Due 23 February 2005
Resolved 23 February 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 January 2005
Resolved
Install double pole circuit breakers on distribution panel for all 110 volt circuits.
Due 23 February 2005
Resolved 23 February 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 January 2005
Resolved
Provide updated plans reflecting addion of double pole circuit breakers to 110 volt electrical distribution panel.
Due 23 February 2005
Resolved 23 February 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 7 January 2005
Resolved
Provide at operating station an emergency broadcast placard.
Due 23 February 2005
Resolved 23 February 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 7 January 2005
Resolved
Post emergency procedures for crew and passengers.
Due 23 February 2005
Resolved 23 February 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 January 2005
Resolved
Conspicuously post life jacket donning procedures placard at lounge, upper aft deck, and pilot station.
Due 23 February 2005
Resolved 23 February 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 January 2005
Resolved
Remove battery installation from bilge area and install above bilge.
Due 23 February 2005
Resolved 23 February 2005
Construction/Loadline › Hull › Bottom Plating
Issued 24 November 2004
Resolved
Repair approx 3" blister on hull, starboard side forward near keel.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 7 December 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2004
Resolved
Repair delamination on port and starboard side of aft bulkhead in chain locker.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 7 February 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 24 November 2004
Resolved
Remove wire nuts on all electrical connections throughout vessel or place in an enclosure iaw 183.340.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 February 2005
Engineering › Bilge Water Management System › Not Operational
Issued 24 November 2004
Resolved
Replace rubber household overboard discharge plugs on starboard side in sewage space with threaded marine type.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 7 December 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 24 November 2004
Resolved
Prove proper operation iaw. the manufacturers instructions, the type 1 marine sanitation device.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 February 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 24 November 2004
Resolved
Prove engine room fixed FE241 Fire system of 1100 cu.ft. is large enough for engine room, sewage and fuel tank spaces. Note: Engine room has free communication with both adjacent spaces.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 February 2005
Resolution: Engine room made vapor tight in way of both forward and aft bulkheads.
Engineering › Bilge Water Management System › Valve
Issued 24 November 2004
Resolved
Provide shut off valves at overboard discharge for bilge pumps iaw. 182.520
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 December 2004
Construction/Loadline › Hull › Stringer
Issued 24 November 2004
Resolved
Aft of engine room hatch, put overhead stringer beams #2 and #3 back into original position.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 February 2005
Construction/Loadline › Hull › Side Shell
Issued 24 November 2004
Resolved
Fill screw holes on starboard side around passenger embarkation area.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 February 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 November 2004
Resolved
Fix top step of staircase above machinery space opening.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 7 February 2005
Electrical
Issued 9 May 2000
Resolved
SUBMIT ELECTRICAL PLANS IAW 46 CFR 176.700 CONTAINING INFORMATION REQUIRED BY 46 CFR 177.202(b)(4) FOR NEW GENERATOR. ITEM MUST BE COMPLETED AND INSTALLATION APPROVED PRIOR TO OPERATING GENSET WITH PASSENGERS ABOARD.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Fire Fighting
Issued 9 May 2000
Resolved
HAVE ANNUAL SERVICING PERFORMED ON PORTABLE AND FIXED FIRE EXTINGUISHERS. ITEM TO BE COMPLETED PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Unknown
Issued 9 May 2000
Resolved
PROVIDE PROOF OF CURRENCY FOR DRUG TESTING PROGRAM.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Construction/Loadline
Issued 10 May 1999
Resolved
INSTALL AUDIBLE AND VISUAL BILGE HIGH LEVEL ALARMS I.A.W. 46 CFR 182.530.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 10 May 1999
Resolved
PROVIDE CORRECTLY SIZED FIXED FIRE FIGHTING SYSTEM FOR ENGINE ROOM. SYSTEMIS TO BE INSTALLED I.A.W. 46 CFR 181.420
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 19 May 1997
Resolved
Properly secure steps leading into the engineroom.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Engineering
Issued 19 May 1997
Resolved
Install a proper fuel valve pull handle for starboard fuel valve. Demonstrate proper operation.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 19 May 1997
Resolved
Properly secure spare 12 volt battery from movement.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Fire Fighting
Issued 10 June 1996
Resolved
REMOVE NON-CG/UL APPROVED FIXED HALON FIRE FIGHTING SYSTEM FROM VESSEL. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Navigation
Issued 26 June 1995
Resolved
Prior to operation in reduced visibility, demonstrate proper operation of stern light.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Fire Fighting
Issued 26 June 1995
Resolved
Demonstrate proper operation of smoke detector.
Condition: Unknown
Due 26 June 1995
Resolved 26 June 1995
Lifesaving
Issued 27 May 1994
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL A NEW BATTERY IN SMOKE DETECTOR.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 27 May 1994
Resolved
REPLACE AFT HEAD CIRCUIT BREAKER WITH 10 AMP BREAKER. 15 AMP BREAKER TO REMAIN SECURED TILL REQUIREMENT MET.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 27 May 1994
Resolved
BILGE PUMP BREAKERS TO BE CHANGED TO 5 AMPS EACH.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 27 May 1994
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE, REPLACE 10 AWG WIRE FROM GENERATOR TO 60 AMP CIRCUIT BREAKER WITH 8 AWG WIRE.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 27 May 1994
Resolved
DEMONSTRATE THE INTERNAL PROTECTION FOR THE GENERATOR.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Accommodation/Occupational Safety
Issued 27 May 1994
Resolved
PROPERLY VENT MSD SYSTEM WITH 30 X 30 MESH FLAME SCREEN.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Accommodation/Occupational Safety
Issued 27 May 1994
Resolved
DEMONSTRATE HIGH LEVEL ALARM ON MSD SYSTEM.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Electrical
Issued 10 May 1994
Resolved
PRIOR TO CERTIFICATION, SATISFACTORILY ADDRESS ALL COMMENTS FROM ELECTRICALPLAN REVIEW TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Accommodation/Occupational Safety
Issued 10 May 1994
Resolved
SUBMIT PLANS AND SATISFACTORILY ADDRESS ALL COMMENTS, FOR NEW MARINE SANITATION DEVICE, FROM PLAN REVIEW BY MARINE SAFETY OFFICE SAN FRANCISCO BAY.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Documentation
Issued 10 May 1994
Resolved
PRIOR TO CERTIFICATION, DEMONSTRATE TO THE COGNIZANT O.C.M.I. THAT THE VESSEL'S DRUG TESTING PROGRAM IS BEING USED (PRE-EMPLOYMENT).
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994