SUNDIVER is a 1989 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in May 2026, along with 52 deficiencies, 3 operational controls and 1 casualty investigation in 2008.

Records from 2008 to 2026. Most recent: inspection, 4 May 2026.

Built
1989
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI4978
339349
Flag
UNITED STATES
Maury page id
psix-339349

Documentation record

Registered dimensions (L × B × D)53.0 ft × 16.8 ft × 3.0 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRADOVCHICH BOATWORKS · WILMINGTON, CA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

4 May 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8332068
14 April 2026 Hull Examination · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8304924
19 September 2025 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8240403
5 February 2025 Plan Review "T" Boat · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8069102
23 November 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8037821
21 May 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7882579
24 April 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7882575
2 April 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7888172
6 December 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7834707
6 June 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7706369
4 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7668248
31 March 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655266
28 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613969
2 December 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7603000
9 October 2022 Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 7592946
26 May 2022 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7465865
4 May 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7443794
12 March 2022 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7410646
7 November 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7346751
3 May 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188004
13 May 2020 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6955487
7 January 2020 Administrative Inspection · COI Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6884575
23 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6646313
30 May 2018 Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414148
29 May 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414101
21 February 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6361627
15 May 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6142950
8 August 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5969364
21 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5848701
21 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5795285

Deficiency record · 52

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2026 Resolved
(a) Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. STBD side amidships railing missing 1 bolt on both stanchions causing railing to be weak and not secure. Secure railing to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2026
Resolved 6 May 2026
Resolution: Attended vsl and verified satisfactory repairs of railing. All sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 May 2026 Resolved
A proper certificate issued by the federal communications commission shall be regarded as evidence that the radio installation, if any, is in compliance with the requirements of that agency. FCC radio station license was expired. Renew and make certificate available to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 24 June 2026
Resolution: Recieved satisfactory payment reciept for FCC certificate.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 May 2026 Resolved
At each initial and subsequent inspection for certification, the inspector shall examine and test all items in the ships outfit, such as ground tackle, navigation lights, compass, etc.. which are required to be carried by the regulations in this sub chapter. Ships stern light was inoperable. Make light operational and make available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
Resolution: Verified satisfactory operation of stern light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 February 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. Port main engine had a fuel leak on return line.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 19 February 2025
Resolved 26 February 2025
Resolution: Operator replaced fuel lines with OEM parts, MI witnessed satisfactory operation of port MDE.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 5 February 2025 Resolved
For life float - approved under series 160.027 Life float was deteriorated and not serviceble, restricted to 22 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2025
Resolved 26 February 2025
Resolution: MI witnessed repaired life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 February 2025 Resolved
Bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Suction foot in bunkroom and head compartment did not have strainer.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 26 February 2025
Resolution: MI witnessed bilge suction strainers in place.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 February 2025 Resolved
The owner or operator shall be provided to test the steering system to determine suitable condition and fit for service. Port rudder post packing leaked excessively during operational test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 26 February 2025
Resolution: MI witnessed port rudder post steering with minimal leakage underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2024 Resolved
Fuel Oil Service. STBD AFT MDE shutdown inoperable. Repaired on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 April 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2024 Resolved
Hull Structure. Focsle longitudinal deck beam at access coming louver deteriorating. Deferred to dry dock.
Action required: 705 - Other - as specified
Resolved 31 May 2024
Resolution: Metal and Doug Fir support beams added to support Focsle Deck.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2024 Resolved
Hull structure. Lazarette deck plate wood is soft. Deferred to dry dock 31May24.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 31 May 2024
Resolution: Sister beams added to lazarette. Deck plate satisfactory to next drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2024 Resolved
Main Propulsion System. MI identified port shaft packing excessively leaking.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 April 2024
Resolution: Operator stated packing was tightened.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2024 Resolved
Not later than April 1, 2024, an operator of an overnight fishing charter not in compliance with such section 3306(n)(3)(A)(v) shall submit to the Commandant a plan for complying with such requirements. A plan for IFR compliance has not been submitted to the cognizant [name withheld] are prohibited access to overnight accommodation spaces. NDAA FY24 Section 3531(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 February 2025
Resolution: Vessel installed watch alerter and provided plans for galley egress modification.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2023 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessel is restricted from overnight accomidation operations until plans for system are submitted. 46CFR185.410(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 28 January 2025
Resolution: Vessels COI has been updated & will no longer be allowed to carry overnight passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2023 Resolved
Except as otherwise provided in this section vessels in ocean service shall carry sufficient life floats for all persons on board. One of vessels 22 life floats serving 22 pax is currently being serviced and has been replace with 12 pax life float. Restrict pax count to 34 until vessel receives 22 pax life float from servicing company. 46CFR180.10-5
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 June 2023
Resolution: 22 Pax life float serviced and properly installed. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2023 Resolved
The bilge suction shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Engine room fwd bilge suction missing strainer. 46CFR182.25-5(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 6 June 2023
Resolution: Operator satisfactory replaced missing strainer. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2023 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. MI observed excessive water from shaft packing and minimal water from port/stbd rudder posts. 46 CFR 176.25-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 6 June 2023
Resolution: MI observed satisfactory shaft packing and rudder posts while U/W. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI identified loose wires that were not supported and numerous dead end wires located in the laz.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 6 June 2023
Resolution: Loose/dead end wires properly supported and addressed. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2023 Resolved
The painter must be of dark color if synthetic or of a type certified to be resistant to deterioration from ultraviolet light. MI observed minimal deterioration on life float line serving 22 pax.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 6 June 2023
Resolution: Painter line replaced. All Sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 28 December 2022 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessel has not submitted plans or installed the required Watchmen system. Vessel is restricted from carrying overnight passengers until deficiency is rectified. 46CFR185.410(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 January 2023
Resolved 29 December 2022
Resolution: Vessel Operator submitted plans for watchkeeper system and interconnected fire detectin system.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. Vessel has not installed an interconnected Fire detection system as required. Vessel is restricted to no more than Limited Coastwise route until deficency is rectified. 46CFR181.450
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 January 2023
Resolved 6 June 2023
Resolution: Vessel installed interconnected fire detection system.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 May 2022 Resolved
As id'd during the dry dock exam, vessel is required to repair/resurface the deck due to excessive cracking and de-surfacing effects.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2022
Resolved 6 June 2023
Resolution: Mi observed satisfactory surface on deck. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 26 May 2022 Resolved
Vessel required to remove-treat rotten wood as id'd on bulkhead located in passenger/accommodation space which seems to be the effect from a leaking shower drain located above in the wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2022
Resolved 1 December 2022
Resolution: MI verified repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2022 Resolved
Vessel required to remove-clean-treat angel rot wood in the engine room as id'd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2022
Resolved 1 December 2022
Resolution: MI verified repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 May 2022 Resolved
Vessel required to replace 1 1/2" ball valve on portside used for freshwater overflow tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2022
Resolved 1 December 2022
Resolution: MI observed properly installed new 1 1/2" ball valve.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 May 2022 Resolved
Prior to carrying overnight passengers owner shall provide documentation proving mattresses comply with the required standard.
Action required: 705 - Other - as specified
Due 30 May 2023
Resolved 6 June 2023
Resolution: Operator removed mattresses from vsl. All Sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 May 2022 Resolved
Operator was not able to prove proper operation of required public address system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2022
Resolved 1 December 2022
Resolution: Operator proved proper operation of P/A system.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 May 2022 Resolved
vessel is missing required marking for max allowed passengers on upperdeck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 6 June 2023
Resolution: Marking for allowed pax on upper deck. All Sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2022 Resolved
vessel is missing labeling for escape hatch location outside of head.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 6 June 2023
Resolution: Vsl escape hatch properly marked. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2021 Resolved
Each life jacket carried on a vessel on oceans route must have a life jacket light approved and securely attached to the jacket. Vessel only has 32 life jackets with working lights. Vessel to provide 04 lights for life jackets. Vessel restricted to 32 total persons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 17 June 2021
Resolution: Vessel provided life jacket lights.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 May 2021 Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the bridge-to-bridge act. Vessel is missing FCC Certificates. Vessel to provide certificates.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 17 June 2021
Resolution: Vessel provided certificate.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 May 2021 Resolved
Provision shall be made by means plugs, covers, etc., to prevent the admission of air into space protected. Dampers did not actuate. Vessel was able to prove proper operation prior to the end of the exam.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 3 May 2021
Resolution: Vessel operator was able to demonstrate compliance prior to the end of the inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 5 February 2020 Resolved
All mattresses must comply with either FF 4-72.16 or IMO Res A.688(17), and may only contain polyurethane foam when tested to Res A.688(17). Provide proof of mattresses complying with regulations or plan to replace mattresses that are approved.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 4 May 2022
Resolution: reissued deficiency (see activity #7443794) vessel is restricted from conducting overnight operations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 June 2019 Resolved
Except as otherwise provided in this section, vessels in ocean service shall carry sufficient life floats for all persons on board. One 22 person life float discoivered in unserviceable condition. restrict pax count to 22 until rectified (replaced). 46 CFR 180.10-5(a) (Old-T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: lifefloat replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 June 2019 Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached. Tag on STBD life float weak link missing. Prove breaking strength or replace (along with whole STBD life float) prior to carriage of full pax. 46 CFR 160.073-20(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: weak link replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 June 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. Restricted / night diving light non-functional. prove proper operation. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 8 August 2019
Resolution: Burnt out light replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 June 2019 Resolved
A vessel of 12 meters or more in length shall be provided w/ a whistle. Fixed horn is non-functional. Prove proper operation. 33 CFR 83.33(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 8 August 2019
Resolution: sound signaling device provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 April 2019 Resolved
All other vessel must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) of this section. (b)(1) Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is currently overdue for required annual inspection. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
Resolution: Conducted satisfactory annual inspection.
Lifesaving › Lifefloat › Serviceable
Issued 29 May 2018 Resolved
Provide satisfactory/servicable life float. Max total persons onboard reduced to 22 until satisfactory replacement provided.
Action required: 705 - Other - as specified
Due 4 June 2018
Resolved 5 February 2020
Resolution: Operator replaced unservicable life float IAW with applicalble regulations. Verified SAT. Total persons onboard restored to COI allowance of 36.
Stability › Unintentional Flooding › General
Issued 29 May 2018 Resolved
Repair light for engine room high bilge alarm
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 July 2018
Resolution: working properly
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2018 Resolved
make temporary wiring into junction box in engine room permanent and route appropriately.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2018
Resolved 5 July 2018
Resolution: repaired
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 29 May 2018 Resolved
Vessel didn't have complete/current MIS report onboard. Corrected prior to end of exam.
Action required: 10 - Deficiency Rectified
Due 4 June 2018
Resolved 4 June 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 February 2018 Resolved
Complete satisfactory drydock inspection for credit.
Action required: 705 - Other - as specified
Resolved 5 July 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2017 Resolved
Prove proper operation of fuel shutoff valves prior to carrying passengers. 46CFR182.20-40(b)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 May 2017 Resolved
Provide rail courses on embarkation gate on port side so that spacing between courses does not exceed 12 inches. 46CFR177.35-1(b)
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 15 May 2017
Resolution: Rail course netting installed
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2017 Resolved
Install shutoff valves for generators so that they are operable from outside the tank space prior to operating generators. 46CFR182.20-40(b)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 May 2017
Resolution: Installed and working properly
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 May 2017 Resolved
Prove proper operation of smoke detector in bunk room prior to carrying overnight passengers. 46CFR181.450
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2017
Resolution: New smoke detector installed
Lifesaving › Lifefloat › Float-free Link
Issued 21 April 2016 Resolved
Provide correct weak link with tag for port side lifefloat. 46 CFR 180.130
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 8 August 2016
Resolution: Weak link with tag provided and properly installed for port side lifeboat
Lifesaving › Lifefloat › Serviceable
Issued 21 April 2016 Resolved
Make starboard lifefloat orange in color. 46 CFR 185.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 8 August 2016
Resolution: Starboard lifefloat properly made orange in color.
Lifesaving › Lifefloat › Serviceable
Issued 21 April 2016 Resolved
Repair holes in starboard lifefloat. 46 CFR 185.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 8 August 2016
Resolution: All holes repaired on starboard lifefloat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 April 2016 Resolved
Renew FCC Safety Radio Certificate with correct call sign matching current FCC Station License in accordance with 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 7 November 2021
Resolution: Safety Radio Certificate has correct call sign.
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 January 2016 Resolved
Loosen ball valve for intake on port MDE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 29 January 2016
Resolution: Replaced ball valve
Engineering › Steering Gear System › Rudder Bearing
Issued 21 January 2016 Resolved
Tighten packing on port rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 29 January 2016
Resolution: Repacked port rudder

Casualty record · 1

17 August 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3301183