Records from 1989 to 2008. Most recent: inspection, 30 January 2008.
Inspection history · 53
30 January 2008
Ballast Water Examination · COC-TVE Annual · Deficiency Check · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3135663
16 March 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2887399
22 January 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2860202
18 January 2007
ISPS II Exam · COC-TVE Renew · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2857336
18 January 2007
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2858148
16 January 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2856848
10 October 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 282445
19 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 276822
30 January 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 493635
3 November 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 434290
8 September 1999
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457691
6 September 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 432539
2 February 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 504218
6 December 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 23548
6 December 1997
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 780871
6 November 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 409672
11 August 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 406687
12 May 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 403962
2 May 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 643543
17 April 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 170831
17 April 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 211893
24 March 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 89303
5 December 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 398336
21 October 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 501061
6 July 1996
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 392782
23 May 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 391462
21 May 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 391381
22 November 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 385281
11 September 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 647907
26 July 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 677205
21 July 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 188927
20 July 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 199780
20 July 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 494190
7 May 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 446726
7 May 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 872901
1 May 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 512056
5 March 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 496183
5 March 1994
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 855397
27 December 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 647896
10 December 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852553
8 December 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 677206
7 December 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 57559
7 December 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 514586
16 March 1993
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1144186
25 July 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 499427
11 April 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 502915
21 November 1991
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253343
16 May 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 471571
19 September 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 929725
29 April 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 531792
20 October 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 333187
20 October 1989
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895121
20 October 1989
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206247
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 22 January 2007
Resolved
Received notification that the gyrocompass repeater onboard were inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2007
Resolution: Received tech report that repairs have be completed.
Construction/Loadline › Structures › Deck Plating
Issued 17 January 2007
Resolved
Several holes have been cut into the main deck fish plate, compromising containment if oil/cargo spills on deck. Make permanent repairs to the satisfaction of class society/ flag representatives. 33CFR155.310(a)(3)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Documentation › Certificates/Documents › NLS Certificate
Issued 17 January 2007
Resolved
Vessel did not have a valid NLS certificate onboard. Previous certificate expired on December 31, 2006 and was not extended by the administration. An interim certificate was issued by class for the cargo currently on board. Provide copy of full term valid NLS certificate to cognizant captain of the port prior to cargo operations at next u.s. port. Marpol II/10.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 January 2008
Resolution: Verified valid NLS certificate
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 17 January 2007
Resolved
Cargo transfer procedures do not meet u.s. requirements. 33CFR155.750 -fix prior to transferring cargo.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2007
Resolution: Received & reviewed satisfactory cargo transfer procedures.
Lifesaving › Lifebuoys › Size
Issued 17 January 2007
Resolved
Life buoys on port and starboard bridge wings are not of sufficient weight to operate the quick release device. Life buoys must weigh at least 4kgs. Solas 74(am) III/31.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2007
Resolution: received proof of proper lifebuoy purchase from agent.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 17 January 2007
Resolved
Vapor control line pin is not at the 12 o'clock position on the port forward and starboard aft lines. Correct/relabel lines prior to next u.s. port. 46CFR39.20-1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 January 2008
Resolution: Verified proper placement of pin on vapor connection flange between bolt holes, and in line with the bolt hole pattern.
Lifesaving › Launching Appliances › Davit
Issued 17 January 2007
Resolved
Both lifeboat davits reach the stops prior to activating the limit switches, potentially overstressing the falls. Fix/ address to the satisfaction of class society/ flag representative. *port aft bracket is also damaged* Solas 74(am) III/48.2.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 January 2007
Resolved
Fire control plan does not accurately reflect the use of spaces and layout of spaces (on main deck, laundry/linen spaces are being used as chemical and general stores; layout of boat deck not correct). To the satisfaction of class society/ flag representative, ensures proper fire protection of spaces for current use and update fire plan to accurately reflect conditions onboard. Solas 74(am) II-2/6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 January 2007
Resolved
Fuel oil tank next to the emergency fire pump space is leaking fuel oil, soaking the insulation, indicating a possible crack/hole in the tank and creating a fire hazard. identify cause and repair/replace insulation to the satisfactory of class society/flag representative. Solas 74(am) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 17 January 2007
Resolved
Main inert gas blower leaks inert gas from the shaft seal. Belt slipping secondary blower. Repair/ address and demonstrate proper operation of calibration, safetys, and alarms, and full operationof the system to the satisfaction of class society/ flag representative. Solas 74(am) II-2/62
Due 18 March 2007
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 January 2007
Resolved
Sounding pipes for forward fuel oil tanks (in bos'n stores) are leaking fuel oil. Fix/ repair to the satisfaction of class society/ flag representative. Solas 74(am) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Fire Fighting › Ventilation Systems › Smoke Extraction System
Issued 17 January 2007
Resolved
Exhaust ventilation for emergency fire pump space is wasted and holed at the upper level of the ladder. Repair to the satisfaction of class/ flag representative. Solas 74(am) I/11
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Fire Fighting › Structural - B Class Divisions › Machinery Spaces
Issued 17 January 2007
Resolved
B-O door to engine office is damaged and will not provide intended level of fire protection. Fix/ repair to the satisfaction of class society/ flag representative. Sloas 74(am) II-2/3.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 17 January 2007
Resolved
Valve position indicators on both manifolds and on crossover valves are damaged/ inoperable, unable to show whether valves are open or clo0sed. Fix/ repair to the satisfaction of class society/ flag representative. 33CFR156.120
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 17 January 2007
Resolved
Stern tube has a continuous leak of lubricating oil. Fix/repair to the satisfaction of class society/flag representative.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2007
Resolution: Item cleared due to receipt of Class Report dated 20 JAN 07.
Engineering › Steering Gear System › Pump
Issued 16 January 2007
Resolved
Received notification that the starboard steering pump is inoperable. Vessel must have a certified technician make repairs and fax a copy of the report to the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2007
Resolution: Received satisfactory class report that repairs have been made.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 10 October 2000
Resolved
VESSEL HAD EXCESSIVE IG LEAKS IN BLOWER ROOM FROM PIPES AND SEALS.
Condition: Unknown
Due 11 October 2000
Resolved 18 January 2007
Resolution: Cleared deficiency due to it''s extreme age and issued revised def under Sector San Fran Activity # 2857336
Documentation
Issued 10 October 2000
Resolved
Vessel failed to have COFR Certificate on board.
Condition: Unknown
Due 10 October 2000
Resolved 20 October 2000
Fire Fighting
Issued 10 October 2000
Resolved
Fire fighting and lifesaving drills were unsat.
Condition: Unknown
Due 10 October 2000
Resolved 20 October 2000
Lifesaving
Issued 10 October 2000
Resolved
Vessel had approximately 30 drums of waste oil sotered on deck. Required master dispose of to a proper reception facility.
Condition: Unknown
Due 10 October 2000
Resolved 20 October 2000
Deck/Cargo
Issued 10 October 2000
Resolved
THERE WERE NO SPAN GASES FOR THE CALIBRATION OF THE FIXED AND PORTABLE OXYGEN, COMBUSTABLE GAS, AND FLAMMABLE VAPOR DETECTION SYSTEMS.
Condition: Unknown
Due 10 October 2000
Resolved 8 November 2000
Deck/Cargo
Issued 10 October 2000
Resolved
THERE WAS NOT A MAINTENANCE PROGRAM IN PLACE AND MAINTENANCE HAD NOT BEEN CONDUCTED ON THE PORTABLE AND FIXED OXYGEN AND GAS DETECTION INSTRUMENTS.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 10 October 2000
Resolved
MAINTENANCE PROGRAM AND PROCEDURES WERE NONE EXISTENT FOR THE FIXED AND PORTABLE OXYGEN AND GAS DETECTION SYSTEMS.
Condition: Unknown
Due 24 October 2000
Resolved 18 January 2007
Resolution: Maintenance Program inplace and up to date.
Deck/Cargo
Issued 10 October 2000
Resolved
VESSEL USED 2 IM201 PORTABLE TANKS TO SATISFY THE REQUIREMENT FOR SLOP TANKS. REQUESTED THAT THE MASTER VERIFY WITH THE NEW FLAG STATE THAT THE PORTABLE TANKS SATISFY THE SLOP TANK REQUIREMENTS.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Lifesaving
Issued 10 October 2000
Resolved
VESSEL'S CREW COULD NOT LOWER THE LIFEBOAT NOR START THE LIFEBOAT ENGINES.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Fire Fighting
Issued 10 October 2000
Resolved
THE VESSEL'S FIRE EXTINGUISHING SYSTEMS HAD NOT BEEN SERVICED OR INSPECTED IN AN EXTENDED PERIOD. THEY INTENDED TO SERVICE THE SYSTEMS WHEN THEY WERE IN LAKE CHARLES, LA IN AUGUST BUT DUE TO SCHEDULES AND COST DECIDED TO PUT IT OFF. UNITOR HAD RECOMMENDED ALMOST FULL REPLACEMENT.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Documentation
Issued 10 October 2000
Resolved
VESSEL DID NOT HAVE A USCG APPROVED VESSEL RESPONSE PLAN. THE COMPANY HAD BEEN AFFORDED 1 TIME TRANSITS IN OTHER PORTS.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 October 2000
Resolved
DECK HYDRAULIC SYSTEM HAD NUMEROUS LEAKS ON DECK AND IN THE HYDRAULIC ROOM BY THE CO2 FLAT. THE CREW HAD TO MAINTAIN A READY SUPPLY OF HYDRAULIC FLUIDBECAUSE OF LEAKS. THERE WAS A JABSCO PUMP MAINTAINED IN A 55 GAL DRUM WITH A HOSE LEAD TO THE RESERVOIR.
Condition: Unknown
Due 10 December 2000
Resolved 18 January 2007
Resolution: Leaks corrected by replacement of hydraulic fittings.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 October 2000
Resolved
Vessel did not have a procedure in place to properly dispose of partially incinerated plastics(clinkers). Evidence showed that they had been mixing plastic residue with regular ash. Vessel shall provide a procedure to ensure proper disposal of incinerated plastics.
Condition: Unknown
Due 24 October 2000
Resolved 18 January 2007
Resolution: Incineration of plastics no longer permitted IAW Garbage Management Plan issued by new owners.
Engineering › Fuel Oil Service System › Piping
Issued 10 October 2000
Resolved
PURIFIER FLAT WAS COVERED IN OIL. THERE WERE SEVERAL PLACES WHERE THERE WERE A FEW INCHES OF BUILD-UP.
Condition: Unknown
Due 11 October 2000
Resolved 18 January 2007
Resolution: Purifier Flat was cleaned up.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 10 October 2000
Resolved
THE ENGINE, WIRE TRAYS, MOTORS AND EQUIPMENT NEXT TO ENGINES WERE COATED WITH FUEL OIL. THE CONDITION AROUND THE ENGINES CREATED A FIRE HAZARD.
Condition: Unknown
Due 11 October 2000
Resolved 18 January 2007
Resolution: Area cleaned up at time of COC inspection.
Engineering
Issued 10 October 2000
Resolved
THERE WAS A WEEP IN THE SALTWATER COOLING LINE FOR THE AUXILLARY BOILER.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Engineering
Issued 10 October 2000
Resolved
THE BOILER BLOW-DOWN VALVE ON THE STBD SIDE IN SHAFT ALLEY WAS WASTED TO THE POINT OF CONCERN.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Documentation
Issued 10 October 2000
Resolved
VESSEL DID NOT HAVE A COPY OF THE TWO APPLICABLE VOLUMES OF 33 CFR.
Condition: Unknown
Due 10 October 2000
Resolved 9 November 2000
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 10 October 2000
Resolved
The condition of the inert gas system was found to be substandarad. Many defects were found and had to be corrected prior to cargo discharge.
Condition: Unknown
Due 10 October 2000
Resolved 20 October 2000
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 October 2000
Resolved
Many fire doors were found to unable of closing/sealing. Doors for accom spaces were found missing handles. Mechanical tie backs were used to hold doors open. Required master have doors fixed to ensure they are operable. Of particular interest galley, main ladderwell, and engine room escape.
Condition: Unknown
Due 10 December 2000
Resolved 18 January 2007
Resolution: Condition corrected by means of door replacement and or repair.
Deck/Cargo
Issued 8 September 1999
Resolved
VESSEL TO MAKE AVAILABLE FOR INSPECTION THE PUMP ROOM, BY CERTFIYING GAS FREE WITH MARINE CHEMIST.
Condition: Unknown
Due 8 September 1999
Resolved 14 September 1999
Navigation
Issued 8 September 1999
Resolved
VESSEL TO MAKE REPAIRS TO #1 STEERING PUMP DUE TO EXCESSIVE HYDRAULIC OIL LEAKS AT DIRECTIONAL CONTROL VALVE. REPAIRS SHALL BE TO THE SATISFACTION OFCLASS SOCIETY PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 9 September 1999
Resolved 14 September 1999
Navigation
Issued 6 September 1999
Resolved
THE #2 STEERING PUMP IS LEAKING HYDROLIC OIL. MUST REPAIR LEAK TO THE SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 September 1999
Resolved 10 September 1999
Navigation
Issued 6 November 1997
Resolved
VESSEL REQUESTED LETTER OF DEVIATION FOR INOPERABLE SECOND MARINE RADAR. LETTER OF DEVIATION WAS ISSUED. SERVICE REPORT WAS RECEIVED AND DEFICIENCY WAS CORRECTED.
Condition: Unknown
Due 12 November 1997
Resolved 12 November 1997
Engineering
Issued 12 May 1997
Resolved
RENEW CORRODED DRAIN PLUGS IN FIXED CONTAINMENT FOR STARBOARD FUEL VENT NEAR CO2 ROOM.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Fire Fighting
Issued 12 May 1997
Resolved
HOSEBOX #32 MISSING CLOSURE HASP.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 12 May 1997
Resolved
INSTALL RETRO TAPE ON BOTTOM OF STARBOARD LIFEBOAT.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Fire Fighting
Issued 12 May 1997
Resolved
FIRE PLUG #7 MISSING END CAP.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Accommodation/Occupational Safety
Issued 12 May 1997
Resolved
PROPERLY INSTALL HANDLES ON THE FOLLOWING DOORS: a) DOOR ON STARBOARD WEATHER DECK NEAR LIFEBOAT. b) DOOR BETWEEN WELDING SHOP AND ENGINE ROOM.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Unknown
Issued 12 May 1997
Resolved
INSTALL PROPER FIRE EXTINGUISHER AT STATION #17.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Construction/Loadline
Issued 5 December 1996
Resolved
Make(paint) loadline markings to contrast hull. Repair/renew prior to return to U.S. Waters.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Deck/Cargo
Issued 5 December 1996
Resolved
Portside Inert Gas System blower carron seal leaking. Repair/renew and provide class report.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Documentation
Issued 21 May 1996
Resolved
VSL'S 1ST ASSISTANT ENG. HAS ONBOARD EXPIRED 3RD ENG. LIBERIAN LICENSE. CONFIRMED THRU RESTON, VA (LIBERIAN SEAFARERS SERVICE) THAT NEW LICENSE _x001C_ FOR 1ST ASSISTANT ENG. WAS SENT OUT 20MAY96, #462689 TO EXP. IN MAY 2001._x001C_
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Engineering
Issued 21 May 1996
Resolved
VSL'S OILY WATER SEPARATOR NOT OPERATING PROPERLY. VSL TO RETAIN ONBOARD ALL OIL SLOPS & HAVE OWS TESTED TO THE SATISFACTION OF U.S. COAST GUARD PRIOR TO DEPARTING NEXT U.S. PORT.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Deck/Cargo
Issued 5 March 1994
Resolved
MAKE PERMANENT REPAIRS TO INERT GAS SYSYTEM HIGH O2 ALARM.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Navigation
Issued 5 March 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 March 1994
Resolved 15 March 1994
Unknown
Issued 16 March 1993
Resolved
VESSEL DID NOT HAVE THE REQUIRED SECTIONS OF THE OPA-90 AREA RESPONSE PLAN ONBOARD.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993