Records from 2011 to 2026. Most recent: inspection, 24 March 2026.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 35.0 ft × 6.5 ft
Registered tonnagegross 99 / net 79
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROS. BOAT BLDRS. · FREELAND, WA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKEBAY, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Simplified, Gross Ton
79 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
24 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8311731
10 April 2025
Annual Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8109174
9 September 2024
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7999216
26 February 2024
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7867959
3 November 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7820008
14 April 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7671284
15 September 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7667973
19 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7425478
12 April 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7174016
10 September 2020
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7055207
5 May 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6948904
1 March 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6635016
8 January 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6607325
7 September 2018
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6535114
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360363
7 November 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6302040
18 October 2016
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6022490
20 September 2016
Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6001670
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 February 2024
Resolved
Current man overboard recovery arrangements (rescue platform and ladder) are not designed nor adequate for the recovery of a helpless person from the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 16 April 2024
Resolution: Lifesling installed for MOB recovery (160.064/3729/0) and satisfactory MOB drill performed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024
Resolved
Hoses to and from new secondary fuel filters (on bulkheads) are not SAE J-1942 and fittings do not meet SAE J-1475. Provide fuel hoses meeting SAE J-1942 with end fittings meeting SAE J-1475.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 16 April 2024
Resolution: Hoses to and from scondary fuel filters renewed with hose and fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024
Resolved
Marine gear lube oil cooler hoses and to stainless steal filter housing are not fire rated (both engines). Provide fire sleeve to these hoses in accordance with SAE J-1942-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 16 April 2024
Resolution: Fire sleeves installed over lube oil cooler hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2024
Resolved
Fixed bilge system is unable to take suction from #5 Steering Void. Vessel temporarily authorized to maintain portable gas powered dewatering pump and portable hand pump until satisfactory repairs to fixed system.
Action required: 705 - Other - as specified
Resolved 16 April 2024
Resolution: Foot valve on #5 steering void bilge pick-up repaired and sucttion taken from fixed bilge system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 February 2024
Resolved
Vehicle runway end nets were installed below acceptable rail height requirements, with the lowest points of the nets approximately 21" from the deck. Net courses improperly secured with bungee cord tie-downs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 16 April 2024
Resolution: Vehicle runway nets raised and secured more approriately to stancions.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 April 2022
Resolved
SUITABLE COVERS, GUARDS, OR RAILS SHALL BE INSTALLED IN WAY OF ALL EXPOSED AND HAZARDOUS PLACES SUCH AS GEARS, MACHINERY, ETC. BELTS ON BOTH MAIN ENGINES WERE EXPOSED WITH NO GUARDS IN PLACE. CITE: 46 CFR 177.35-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 5 May 2022
Resolution: Received photograph showing guards in place of belts on main engine.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 April 2022
Resolved
ALL ESCAPE HATCHES AND OTHER EMERGENCY EXITS SHALL BE MARKED ON BOTH SIDES USING AT LEAST ONE INCH LETTERS: "EMERGENCY EXIT, KEEP CLEAR." ENGINE ROOM EMERGENCY EXIT WAS NOT PROPERLY MARKED. PROVIDE PROOF OF EMERGENCY EXIT MARKING. CITE: 46 CFR 185.30-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 5 May 2022
Resolution: Received photograph showing proper marking for emergency escape hatch.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 April 2022
Resolved
PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED AND LOCATED TO THE SATISFACTION OF THE [name withheld] REQUIRED FOR CARRIAGE OF PROPANE TANK TRUCKS LOOSE ON SHELF IN ENGINE ROOM. PROVIDE PROOF THAT FIRE EXTINGISHERS ARE PROPERLY SECURED. CITE: 46 CFR 181.30-10b.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 5 May 2022
Resolution: Operator provided proof that fire extinguishers are properly secured.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 May 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 every five years. If the ship passes the inspection the technician will issue a Communications Act Safety Radio Telephony Certificate. Vessel was found to have an expired Safety Radiotelephony Certificate. Have radio equipment inspected and renew certificate.
47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2020
Resolved 28 May 2020
Resolution: Vessel had radio instillation inspected and submitted FCC Certificate to be uploaded to MISLE
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 March 2019
Resolved
The owner/operator failed to make the vessel available for the annual inspection within three months before or after the anniversary date of the Certificate of Inspection (COI), in accordance with 46 CFR 176.502 the COI became invalid on January 25, 2019.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2019
Resolution: Conducted COI renewal with SAT results. Took possession of vessel log book with dates from 01JAN2019-present. Turned log book into CG Investigations office, Sector Puget Sound.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 March 2019
Resolved
Ring life buoy water light line is degraded and must be replaced.
Action required: 10 - Deficiency Rectified
Due 1 April 2019
Resolved 18 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2019
Resolved
Renew worn retro reflective tape on life jackets.
Action required: 10 - Deficiency Rectified
Due 1 April 2019
Resolved 18 March 2019
Resolution: Retro reflective tape has been renewed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 1 March 2019
Resolved
Unable to meet 2 hour test requirement without alcohol test strips on board.
Action required: 10 - Deficiency Rectified
Due 1 April 2019
Resolved 18 March 2019
Resolution: DOT approved alcohol test strips are on board.
Engineering › Steering Gear System › Rudder
Issued 7 November 2017
Resolved
During next Coast Guard Dry Dock availability, replace packing in both rudder posts to prevent water leakage into Lazerette. Perform rounds daily and record in log. 46 CFR 176.800
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2018
Resolved 3 October 2018
Resolution: Rudder post packing is grease-type; grease applied to both rudder posts. Lines to regularly apply grease have been installed. Routine checks of grease added to onboard checklist.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 November 2017
Resolved
Repair bilge high level alarm in Engine Room. Perform rounds hourly and record in log until alarm is corrected to satisfaction of Marine Inspector. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 14 November 2017
Lifesaving › Hand Flares › Quantity
Issued 7 November 2017
Resolved
Provide distress and smoke signals IAW 46CFR180.68(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 14 November 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 September 2016
Resolved
Provide separation of child and adult sized life jackets within storage container.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 24 September 2016
Resolution: Proper divider was placed within the storage container to separate child and adult life jackets.