Records from 1989 to 2025. Most recent: inspection, 25 November 2025.
Inspection history · 94
25 November 2025
Administrative Inspection · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8297205
3 March 2025
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8087061
9 December 2024
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 8044832
7 February 2024
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7861859
1 February 2024
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7858943
3 March 2023
Internal Structural Exam · Examination of Repairs · In-Service Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7644832
9 February 2023
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7634294
9 December 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7608867
20 October 2022
In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7585154
16 June 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7478953
11 January 2022
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7379643
6 July 2021
In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7246395
26 March 2021
Examination of Repairs · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7188612
16 December 2020
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7117648
23 June 2020
In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6986227
13 May 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6952885
2 October 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6865195
13 May 2019
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6683513
3 May 2019
Deadweight Survey · Inclining Experiment
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6684528
20 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6673965
2 May 2018
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6408666
5 May 2017
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6139338
8 March 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6105589
16 September 2016
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6016406
8 March 2016
Examination of Repairs · Plan Review "T" Boat
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5830454
18 February 2016
COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5816251
26 March 2014
Annual Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4827377
17 January 2012
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4230386
16 January 2012
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4229555
2 July 2011
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4081843
26 October 2010
Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3884535
12 October 2010
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3874152
9 March 2010
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3691513
28 July 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3549207
22 January 2009
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3427857
31 December 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3388500
11 June 2008
DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3626607
9 June 2008
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3231283
25 March 2008
Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3170711
17 May 2007
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2932648
12 March 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2887547
23 May 2006
Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2656405
21 May 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2686531
2 March 2006
Hull Examination · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2594355
7 February 2006
COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2580338
17 October 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2515685
17 October 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2515690
8 October 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2513263
20 May 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2363778
12 May 2005
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2355433
3 November 2004
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2233614
25 March 2004
Deficiency Check · Periodic Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2040364
20 November 2003
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1951186
8 May 2003
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1788840
29 April 2003
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1782367
15 March 2002
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1492629
1 November 2001
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1362506
26 March 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1060767
22 February 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361987
9 April 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048930
21 March 2000
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1047204
21 March 2000
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1047205
16 March 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048180
9 March 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365618
22 February 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 815403
11 January 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 813810
9 December 1999
Plan Review "T" Boat · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1369438
24 September 1999
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 813470
26 May 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801912
6 April 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 786493
30 March 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1360785
28 April 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1124695
10 March 1998
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1121465
21 July 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780241
27 May 1997
Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 773471
15 April 1996
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1080232
6 February 1996
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1185594
6 February 1996
Drydock Extension · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1185844
16 May 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 872000
7 February 1995
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1148033
1 March 1994
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 856478
3 December 1993
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1160310
15 March 1993
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 841041
16 February 1993
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 831987
21 December 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1136627
4 December 1992
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 832801
18 February 1992
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1258276
13 December 1991
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1263053
25 August 1991
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1245705
19 February 1991
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 909349
26 October 1990
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1233502
19 August 1990
Drydock Extension
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 918922
26 July 1990
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1237758
28 February 1989
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1244763
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 December 2020
Resolved
A hatch exposed to the weather must be watertight; replace deteriorated weather sills to the port and starboard engine room hatch covers on the main deck with proper watertight gaskets to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 12 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 December 2020
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. In addition, vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Replace missing barrier where cables/wire penetrate forward port bulkhead between machinery compartment and void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2021
Resolved 20 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 May 2018
Resolved
46CFR182.520: Bilge pump required in aft port and starboard side steering comparments.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 11 May 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 May 2018
Resolved
46CFR182.530: New diode required for stbd high water alarm in aft steering compartment. Stbd high water alarm comes on when port side high water alarm in aft steering is activated.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 6 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 May 2017
Resolved
46CFR185.516: Post correct life jacket donning instructions with one for the type of life jackets currently being carried on board for adult/child life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2017
Resolved 16 June 2017
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 18 February 2016
Resolved
Update the emergency instruction list.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 3 March 2016
Resolution: Corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 February 2016
Resolved
Renew lanyard with detachable clip for lifebuoy.
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Crew fabricated new lanyard.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 12 October 2010
Resolved
Stop use/remove BBQ grill (charcoal).
Due 12 October 2010
Resolved 25 October 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 April 2010
Resolved
Repair port fwd auto bilge pump indicator.
Due 3 May 2010
Resolved 20 April 2010
Engineering › Bilge Water Management System › Pump
Issued 19 April 2010
Resolved
Prove operation of stbd engine driven bilge pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2010
Resolved 22 April 2010
Construction/Loadline › Hull › Hull Plating
Issued 9 March 2010
Resolved
Sand and make available for inspection, crack in paint at hull-to-body joint, fwd, inboard stbd hull.
Due 9 March 2010
Resolved 18 March 2010
Resolution: Paint at crack was removed, FRP laminate appears sound.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 9 March 2010
Resolved
Repair port swim ladder.
19APR10: Extended def until 05MAY10. Grab rails or lines must be installed until corrected.
Due 9 March 2010
Resolved 20 April 2010
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 9 March 2010
Resolved
Replace stbd prop due to pitting at blade flange.
Due 9 March 2010
Resolved 19 April 2010
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 9 March 2010
Resolved
Make stbd strut cutless bearing available for inspection upon removal of stbd prop.
Due 9 March 2010
Resolved 19 April 2010
Engineering › Bilge Water Management System › Strainer
Issued 9 March 2010
Resolved
Clean all bilge strainers.
19APR10: Correct prior to taking pax.
Due 9 March 2010
Resolved 20 April 2010
Fire Fighting › Fire Main › Condition
Issued 9 March 2010
Resolved
Remove rust from galvanized(?) section of firemain piping btw pedro fitting from pump and pedro fitting to firemain system and make available for internal and external inspection.
Due 9 March 2010
Resolved 19 April 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 March 2010
Resolved
Make port collision bhd (plate) watertight. Missing fasteners and not sealed.
19APR10: Correct prior to taking passengers.
Due 9 March 2010
Resolved 20 April 2010
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 March 2010
Resolved
Replace handles on ball valves as needed (PME, SME, firepump).
Due 9 March 2010
Resolved 19 April 2010
Construction/Loadline › Structures › Deck Plating
Issued 9 June 2008
Resolved
Repair deck fractures on upper deck.
Condition: Unknown
Due 30 June 2008
Resolved 17 June 2008
Resolution: Completed satisfactory repairs.
Construction/Loadline › Structures › Superstructure
Issued 9 June 2008
Resolved
Repair fractures on fwd stbd windshield.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 27 January 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 June 2008
Resolved
Repair both fire boy override mode.
Due 30 June 2008
Resolved 10 June 2008
Resolution: Completed satisfactory repairs.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 9 June 2008
Resolved
Inspect port engine fire boy pressure gauge. gauge exhibit over pressurized.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 22 January 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 June 2008
Resolved
Mark vsl name on ring life bouy located on upper deck.
Due 30 June 2008
Resolved 17 June 2008
Resolution: Vessels reps re-stenciled, sat results.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 June 2008
Resolved
Replaced 5 damaged life jackets.
Due 30 June 2008
Resolved 17 June 2008
Resolution: Vessels reps replaced the 5 jackets.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 June 2008
Resolved
Replace retro reflective tapes on 3 life jackets.
Due 30 June 2008
Resolved 17 June 2008
Resolution: Vessels reps replaced the tape on the three effected jackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 June 2008
Resolved
Repair #2 cabin light fixture.
Due 30 June 2008
Resolved 17 June 2008
Resolution: Vessels reps repaired faulty light assmy.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 June 2008
Resolved
Repair loose water pump bracket.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2008
Resolved 17 June 2008
Resolution: Vessels reps repaired faulty bilge pump and bracket assmy, tested and found sat, tested stbd pump which initially failed, vessels reps discovered the suction and discharge hose was opposite, vessels reps repaired and tested unit sat.
Personnel › Training › First Aid/CPR
Issued 9 June 2008
Resolved
Replace expired first aid kit contents.
Due 30 June 2008
Resolved 1 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 March 2008
Resolved
Install steel wire hangors through out vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 24 April 2008
Resolution: Completed satisfactory repairs.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 25 March 2008
Resolved
Replace stbd propeller, prop has major stray current damage around the hub area and all 3 blades.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Completed satisfactory repairs.
Engineering › Bilge Water Management System › Piping
Issued 25 March 2008
Resolved
Add s/s hangors to all the fixed bilge suction piping, all steel hangors are missing and or rotted half off.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps replaced all hangors with s/s rubber hangors.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 March 2008
Resolved
Replace port engine sea strainer bracket, vessels reps used s/s hardware with aluminum plate, plate is rotted away and needs replacement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps replaced the bracket with sat results.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 March 2008
Resolved
Repalce PVC piping in both raw water suction to sea strainers, both port & stbd sides have pvc elbows and nipples which need to be replaced with metalic type.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Completed satisfactory repairs.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 25 March 2008
Resolved
Tighten both port and stbs side raw water belts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps tightend all belts with sat results.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 25 March 2008
Resolved
Port engine driven bilge ITT pump has a severely kinked hose (suction side) which needs an elbow to be intalled to remedy the situation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps installed a 90 degree albow and replaced the hose with sat results.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 March 2008
Resolved
Replace stbd exhaust hose in engine room, hose is collapsed and blocking exhaust gases from going through.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps replaced stbd exhausr hose, all sat.
Engineering › Steering Gear System › Hydraulic Hose
Issued 25 March 2008
Resolved
Secure loose hose for steering gear.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps secured and hung hose with s/s hose clamps, all sat.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 25 March 2008
Resolved
Tighten port shaft strut, strut is a bolted design and in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 April 2008
Resolution: Vessels reps tourqed down the strut with sat results.
Construction/Loadline › Hull › Hull Plating
Issued 25 March 2008
Resolved
Repair bow area fractures where port cat hull adheres to center hull, repair stbd scupper, repair two fractures in the forward storage lockers under windshied both sides have fractures behind the step area at the frame support. Find where the water is entering fwd space in front of collision blkd.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Completed satisfactory repairs.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 March 2008
Resolved
Batteries storage in not comply with the regulation. It shall be as high above the bilge as practical.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 1 May 2008
Resolution: Relocate batteries to meet regulation requirement.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2007
Resolved
Replace anchor light lense and remount stern light.
Due 25 May 2007
Resolved 23 May 2007
Communications › Visual Communication › Warning Sign (gangway)
Issued 16 May 2007
Resolved
Permanently mark upper pax limit.
Due 25 May 2007
Resolved 23 May 2007
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 23 May 2006
Resolved
Identify loose drive train on stbd engine @ coupling.
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 2 June 2006
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 23 May 2006
Resolved
Inspect cutlass bearing.
Action required: 705 - Other - as specified
Resolved 24 May 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2006
Resolved
Install audible bilge alarm capable of being heard with engines running.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 February 2006
Resolved
Replace retroreflective tape on identified life jackets (15).
Due 21 February 2006
Resolved 22 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 February 2006
Resolved
Provide complete first aid kit.
Due 21 February 2006
Resolved 22 February 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 February 2006
Resolved
Replace/repair port fwd bilge indicator.
Due 21 February 2006
Resolved 22 February 2006
Stability › Watertight Integrity › General
Issued 7 February 2006
Resolved
Remove penatrations to collision blkhead or relocate inboard and fit with watertight fittings.
Due 22 March 2006
Resolved 16 May 2007
Stability › Watertight Integrity › General
Issued 7 February 2006
Resolved
Install watertight fittings for all bulkhead penetrations.
Due 22 March 2006
Resolved 16 May 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 12 May 2005
Resolved
Replace retroflective tape.
Due 25 May 2005
Resolved 20 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 May 2005
Resolved
Replace retroflective tape as needed.
Due 25 May 2005
Resolved 20 May 2005
Lifesaving › Lifebuoys › Serviceable
Issued 12 May 2005
Resolved
Replace lifering on upper deck.
Due 25 May 2005
Resolved 20 May 2005
Lifesaving › Lifebuoys › Serviceable
Issued 12 May 2005
Resolved
Re-stencil lifering on lower deck.
Due 25 May 2005
Resolved 20 May 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 May 2005
Resolved
Provide proof of survival craft maintenance.
Due 25 May 2005
Resolved 20 May 2005
Communications › Radio Communications
Issued 25 March 2004
Resolved
Provide copy of Safety Radio Certificate. LEGACY COMPONENT DESC: VHF Radiotelephone
Due 9 April 2004
Resolved 13 April 2004
Communications › Radio Communications
Issued 25 March 2004
Resolved
Provide Radio Operators Permit.
Due 9 April 2004
Resolved 13 April 2004
Operations/Management
Issued 25 March 2004
Resolved
Provide written Waste Management Plan.
Due 9 April 2004
Resolved 13 April 2004
Lifesaving
Issued 25 March 2004
Resolved
Replace retro-reflective tape on life jackets as needed.
Due 9 April 2004
Resolved 13 April 2004
Lifesaving
Issued 25 March 2004
Resolved
Replace retroreflective tape on life rings.
Due 9 April 2004
Resolved 13 April 2004
Lifesaving
Issued 25 March 2004
Resolved
Install weak link on life floats and painter housing to vessel.
Due 9 April 2004
Resolved 13 April 2004
Lifesaving
Issued 25 March 2004
Resolved
Use individual weak links for lifefloats (2) or tie all lifefloats together.
Due 9 April 2004
Resolved 13 April 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 March 2004
Resolved
Have a Drug and Alcohol Program (DAPI) audit conducted.
Due 23 April 2004
Resolved 23 April 2004
Communications › Radio Communications
Issued 15 March 2002
Resolved
Replace expired hydrostatic release on EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 15 April 2002
Resolved 29 April 2003
Resolution: Completed APR02
Unknown
Issued 22 February 2001
Resolved
Company drug and alcohol testing program administrator to contact MSO Guam to schedule annual DAPI audit.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 16 March 2000
Resolved
Attain a contract with a certified drug test collection and analysis labratory.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Fire Fighting
Issued 9 December 1999
Resolved
Provide acceptable method to close ventilation ducts for engine spaces uponactivation of fixed fire extinguishing system.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
Mark bilge manifold suction valves at bilge manifold located on main deck.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide proper markings for bilge pump and emergency fuel shut-off valves.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 30 March 1999
Resolved
Have CO2 portable fire extinguishers that are past due required hydostatic testing serviced in accordance with NFPA 10 by a competent servicing facility.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 30 March 1999
Resolved
Provide a positive shutoff valve at all bilge pump discharge thru hull connections, in accordance with 46 CFR 182.520(e)(7)
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 30 March 1999
Resolved
Install a bilge high level alarm with visual indicator at operating stationfor all spaces with hull penetrations located below the waterline.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Lifesaving
Issued 30 March 1999
Resolved
Obtain missing items to bring 1st Aid Kit up to compliance with 46 CFR 184.710.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Fire Fighting
Issued 30 March 1999
Resolved
Provide proof of purchase of a fixed fire extinguishing system meeting 46 CFR 181.400 for each space containing an internal combustion engine. Vessel COI will be revoked and vessel limited to not more than 6 passengerswithout proof of purchase by 30APR99.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Fire Fighting
Issued 10 March 1998
Resolved
Prove the satisfactory operation of the installed fire pump. The pump shallprovide a sufficient stream of water from the fire hose.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Construction/Loadline
Issued 10 March 1998
Resolved
Maintain a portable bilge pump on board the vessel.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 10 March 1998
Resolved
Provide one B-II size portable fire extinguisher and mount near the hatch to the generator space.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 10 March 1998
Resolved
Provide a corrosion resistant nozzle for the fire hose.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Fire Fighting
Issued 27 May 1997
Resolved
Have all portable fire extinguishers hydostatically tested that are past 5 year required hydro due date.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997
Resolved
Post life jacket donning placard per 46CFR 185.516
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997
Resolved
Obtain three (3) red flare pyro devices.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Navigation
Issued 27 May 1997
Resolved
Post Emergency Communications Broadcast Instructions per 46CFR 184.506&.510
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 6 February 1996
Resolved
Permanently affix vessel official numbers to interior hull of vessel.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Navigation
Issued 6 February 1996
Resolved
Disassemble and inspect rudder quadrant bolts, steering system.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Accommodation/Occupational Safety
Issued 6 February 1996
Resolved
Mark number of passengers allowed on upper deck of vessel.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Documentation
Issued 6 February 1996
Resolved
Post vessel stability letter.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Accommodation/Occupational Safety
Issued 16 February 1993
Resolved
Provide running water for wash basins.
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Documentation
Issued 16 February 1993
Resolved
Provide Garbage plan detailing responsibility and method of garbage disposal.
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Engineering
Issued 16 February 1993
Resolved
Label emergency fuel shut off valves.
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993