MAURY USCG vessel records Sign in
← All vessels

SEA ODYSSEY II

SEA ODYSSEY II is a 1989 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1989, most recently in March 2026, along with 80 deficiencies, 1 operational control and 4 casualty investigations between 2002 and 2024.

Records from 1989 to 2026. Most recent: inspection, 4 March 2026.

Built
1989
Last inspected
4 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW9195
339846
Flag
UNITED STATES
338776000
Maury page id
psix-339846

Inspections, by type

…with no type recorded21
Years with a record 32 calendar years (1989–2026)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 17.0 ft × 7.0 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND DESIGNED BOATS · PITI, GUAM · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationTwin Hull
Hailing portAGANA, GU
Trade endorsementsRegistry
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3449MMSI 338776000 · active · compulsorily equipped · granted 28 July 2026, expires 28 July 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 89

4 March 2026 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8319563
7 April 2025 Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8106115
9 December 2024 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 8044830
1 March 2024 Annual Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7872515
9 January 2024 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7871948
22 November 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7842672
15 October 2023 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 7808858
27 June 2023 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7724468
9 December 2022 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7608853
1 February 2022 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7389387
29 April 2021 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7185197
11 June 2020 Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6976723
8 January 2020 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6907475
3 September 2019 Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6802199
2 January 2019 Administrative Inspection · Construction Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6813600
9 August 2018 Periodic Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6504229
29 January 2018 Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6345111
22 November 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6317279
24 July 2017 Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6514599
23 November 2016 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6046448
16 September 2016 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6016408
7 June 2016 DAPI Audit · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5899721
24 January 2016 Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5802503
30 July 2012 Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4394987
13 July 2012 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4377154
14 June 2012 Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4343308
13 February 2012 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4243030
20 October 2010 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3873253
9 March 2010 Hull Examination · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3690211
16 March 2009 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3433914
21 October 2008 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3348452
3 June 2008 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3225510
22 April 2008 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3189372
10 April 2008 Inclining Experiment
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3181009
11 August 2006 COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2740678
31 May 2006 Hull Examination · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2665538
25 October 2005 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2521354
6 October 2005 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2508629
5 October 2004 Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2213507
1 June 2004 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2093082
18 September 2003 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1907475
20 August 2003 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1881428
9 December 2002 Examination of Repairs · Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1719835
8 December 2002 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1731122
23 October 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1694591
14 October 2002 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1695170
9 October 2002 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1686250
14 May 2002 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1615930
14 August 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366512
29 August 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361680
21 June 2000 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361535
9 March 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1046905
28 December 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 812845
10 December 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 812337
16 November 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 811179
16 September 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 784755
16 August 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1391083
31 August 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 802560
26 August 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1375469
27 July 1998 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1130630
28 June 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 139246
17 November 1997 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1334928
15 October 1997 Excursion Permit
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1110475
9 October 1997 Excursion Permit
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 773632
7 October 1997 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 777248
18 September 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 773967
21 November 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1178790
6 November 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1171903
17 September 1996 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 960312
30 July 1996 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1089891
28 May 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1084401
10 April 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1079751
11 January 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 882517
11 September 1995 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1193742
10 February 1995 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1355087
12 December 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 87200
10 November 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 871713
14 September 1994 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 864629
16 September 1993 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1146936
15 August 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 670940
5 August 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 670941
23 July 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 27928
21 December 1992 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 825854
20 November 1992 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 828031
16 September 1992 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 951147
30 September 1991 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1248776
7 May 1991 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1227405
29 January 1991 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 930028
19 September 1989 Initial Certification · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1215619

Deficiency record · 80

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The visual indicating alarm at the operating station could not be seen when operated. 46 CFR 182.530(a)
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 May 2021 Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards. Crack identified on the third step for the ladder leading to the vessels second deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2021
Resolution: Ladder repaired, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 September 2019 Resolved
Install check valves at some accessible point in the bilge lines leading to bilge suction points. A stop-check valve located at the control point or manifold for each suction line will meet the requirements for both a stop valve and a check valve as required by 46 CFR 182.25-5(c)-"OLD-T" by next dry dock period.
Action required: 705 - Other - as specified
Due 29 February 2020
Resolved 12 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2018 Resolved
Re-apply retroreflective material to 05 adult PFD's.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 August 2018
Resolution: Crew applied new retroreflective material while MI was onboard, Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2018 Resolved
Place solid plugs in the petcocks installed in the bottom of the installed fuel oil filtering devices (Racor's) for both engine compartments.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 9 August 2018
Resolution: Plugs installed while MI was onboard, Corrected on the spot.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 August 2018 Resolved
Replace the lens to the visual alarm for the P-2 high-level alarm at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 August 2018
Resolution: Visual indicator was replaced while MI was onboard, Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2018 Resolved
Re-stencil the vessels name on both ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 August 2018
Resolution: Crew re-stenciled ring buoys while MI was onboard, Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 25 November 2016 Resolved
11 Type III PFD's observed torn/wasted. CG MI destroyed all 11.
Due 25 November 2016
Resolved 25 November 2016
Operations/Management › Vessel Activity › Construction/Repair
Issued 23 November 2016 Resolved
46 CFR 176.700: Port side engine to be replaced with in-kind at discretion of vessel owner. In-service inspection and sea trial to be completed prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 25 November 2016
Stability › Watertight Integrity › General
Issued 7 June 2016 Resolved
Captive chains or devices missing from hatch covers.
Due 8 July 2016
Resolved 16 June 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 July 2012 Resolved
On passenger decks of a vessel on an excursion trip the following must be installed on vessels with 39.5 inch handrails: 1. Bulwarks 2. Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter or 3. Bars, slats, rail courses, or an equivalent spaced at intervals of not more 100 millimeters (4 inches) IAW 46 CFR 177.900 (g)(1) (i)-(iii)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2012
Resolved 18 October 2012
Resolution: Railing modified to meet the 4" requirements.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 October 2010 Resolved
Flame screen on port fuel tank. Replace blocked.
Due 3 November 2010
Resolved 27 October 2010
Lifesaving › Lifebuoys › Serviceable
Issued 20 October 2010 Resolved
Lifering buoys wasted. Replace as new.
Due 20 October 2010
Resolved 27 October 2010
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 October 2008 Resolved
Replace the fuel oil tank and vent hose with approved USCG fuel hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 18 March 2009
Resolution: Vessels reps replaced all hoses with approved CG J type hose, all sat.
Engineering › Bilge Water Management System › Pump
Issued 21 October 2008 Resolved
Secure both engine room bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2008
Resolved 16 March 2009
Resolution: Vessels reps secured both pumps with sat results.
Engineering › Bilge Water Management System › Pump
Issued 21 October 2008 Resolved
High bilge alarm switch needs replacement.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 21 October 2008
Resolution: Vessel reps had new switch installed prior to CG inspection completed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 May 2008 Resolved
Relocate Batteries to location high above the bilge as practical, secure against shifting and moving and not less than 10" head room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 2 June 2008
Resolution: Completed satisfactory repairs.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 October 2005 Resolved
Provide complete first aid kit.
Due 20 October 2005
Resolved 24 October 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 October 2005 Resolved
Secure seating on upper deck.
Due 20 October 2005
Resolved 24 October 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 October 2005 Resolved
Provide means of securing ovbd valve on MSD.
Due 20 October 2005
Resolved 24 October 2005
Engineering › Fuel Oil Service System › Piping
Issued 6 October 2005 Resolved
Install metallic fitting for fuel hoses where penetrating water tight bulkheads.
Due 20 October 2005
Resolved 24 October 2005
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 18 September 2003 Resolved
Prove proper operation of port engine shutdown by use of automatic means (fixed firefighting system).
Due 30 September 2003
Resolved 5 October 2004
Communications › Alarms/Indicators
Issued 9 October 2002 Resolved
Prove audible portion of bilge high level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Due 23 October 2002
Resolved 23 October 2002
Resolution: Audible loud and clear.
Navigation
Issued 10 December 1999 Resolved
Update Apra Harbor Chart with the two new dayboard/light markings for the entrance to Piti Channel.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Lifesaving
Issued 16 August 1999 Resolved
Post emergency instructions on each deck visible to passengers and crew.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
PLACE ON BOARD TWO BUOYANT, PROPERLY MARKED PADDLES FOR LIFEFLOAT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Navigation
Issued 16 August 1999 Resolved
INSTALL UL APPROVED/MARINE GRADE ANCHOR LIGHT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
PROVIDE SUITABLE REFLECTIVE TAPE FOR ALL VESSEL RING BUOYS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
INSTALL PROPER SIZE FLAME SCREENS FOR PORT AND STBD FUEL TANK VENTS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Electrical
Issued 16 August 1999 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING EVERY 24" WITH CORROSIVE RESISTANT METALSUPPORTS, 5/8" WIDE IN PORT AND STBD HULLS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 16 August 1999 Resolved
INSTALL A SECURING DEVICE FOR, AND MAKE ALL MAIN DECK HATCHES WATERTIGHT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Navigation
Issued 16 August 1999 Resolved
REPLACE STERNLIGHT LENS AND RELOCATE STERNLIGHT TO A SUITABLE LOCATION. (ABLE TO BE SEEN CLEARLY FROM ASTERN).
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
PROPERLY GROUND PORT AND STBD FUEL FILL PIPES AND TANKS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Documentation
Issued 16 August 1999 Resolved
PROVIDE A COPY OF A VALID FCC RADIO OPERATORS PERMIT AND RADIO SAFETY_x001C_ CERTIFICATE.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
INSTALL PROPER REFLECTIVE TAPE ON BRIDGE RING BUOY AND INSTALL PROPER LENGTH AND TYPE LANYARD FOR WATERLIGHT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
PLACE ON BOARD A WATERTIGHT FLARE STORAGE BOX.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
PLACE ON BOARD A COMPLETE FIRST AID KIT IN A WATERTIGHT, PROPERLY MARKED CONTAINER.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
INSTALL WATERLIGHT ON BUOYANT APPARATUS WITH AN 18-FOOT LANYARD ON BUOYANT APPARATUS AND LIFEFLOAT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 16 August 1999 Resolved
PROVIDE ADEQUATE ACCESS TO PORT AND STBD SPACES FORWARD OF THE COLLISION BULKHEAD TO ALLOW FOR INSPECTION AND DE-WATERING.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
STENCIL NAME AND CAPACITY ON BUOYANT APPARATUS AND LIFEFLOAT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
POST EMERGENCY OPERATING INSTRUCTION AT THE CONTROL STATION.
Condition: Unknown
Due 16 September 1999
Resolved 18 August 1999
Lifesaving
Issued 16 August 1999 Resolved
INSTALL 12 FEET PENDANTS EVERY 18" ON BUOYANT APPARATUS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 16 August 1999 Resolved
INSTALL RETAINING DEVICE FOR, AND MAKE BAYWOOD DECK HATCHES WATERTIGHT.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
DOUBLE CLAMP ALL RAW WATER HOSES AND EXHAUST PIPING ON PORT AND STBD MDEs_x001C_ AND ALL BILGE PUMP HOSE CONNECTIONS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 16 August 1999 Resolved
PROVIDE VENT CLOSURES FOR PORT AND STBD ENGINE ROOMS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
INSTALL REMOTE FUEL SHUT-OFF VALVE AT THE FUEL TAMK PIPE CONNECTION; PORT_x001C_ AND STBD FUEL TANKS. PROPERLY LABEL AND PROVE OPERATION OF THE REMOTE SHUT-OFF VALVE. OPERATION MUST BE ABLE TO TAKE PLACE FROM OUTSIDE THE FUEL TANK SPACE.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
REPLACE FUEL SUPPLY AND RETURN HOSES WITH SAE J-1942 HOSE AND SAE J-1475 FITTINGS ON PORT AND STBD MDEs AND FUEL TANKS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Engineering
Issued 16 August 1999 Resolved
RENEW EXISTING STBD MDE REMOTE FUEL SHUT-OFF VALVE HANDLE PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 16 August 1999 Resolved
REMOVE OIL ABSORBENT PADS FROM PORT AND STBD ENGINE ROOM BILGES.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Fire Fighting
Issued 26 August 1998 Resolved
Provide proof of yearly servicing of portable fire extinguishers.
Condition: Unknown
Due 9 September 1998
Resolved 31 August 1998
Fire Fighting
Issued 26 August 1998 Resolved
Provide one more B-II sized portable fire extinguisher for vessel bringing total to 3 B-II and 1 B-I.
Condition: Unknown
Due 9 September 1998
Resolved 31 August 1998
Navigation
Issued 7 October 1997 Resolved
Prove operation of compass light to allow night time operation.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Fire Fighting
Issued 7 October 1997 Resolved
Prove operation of vessel's installed fire pump. Pump shall be capable of providing an effective stream from the hose to all sections of the vessel.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Construction/Loadline
Issued 7 October 1997 Resolved
Repair/cover the "vent holes" in the hatch cover, port hull, forward.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Fire Fighting
Issued 7 October 1997 Resolved
Obtain proper mounts/holders for the portable fire extinguishers.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 7 October 1997 Resolved
Install weak link and line for the vessel's Buoyant Apparatus. Weak link to be matched to the Buoyant Apparatus capacity.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Unknown
Issued 7 October 1997 Resolved
Prove training for supervisory personnel as required by 46 CFR 16, DOT/CG Drug and Alcohol Testing Program.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 7 October 1997 Resolved
Provide method to allow Buoyant Apparatus to float free. Buoyant Apparatusmay not be tied down in place unless it can float free.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 17 September 1996 Resolved
Repair or replace ring bouy located on bridge/control station of vessel.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Documentation
Issued 17 September 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Accommodation/Occupational Safety
Issued 17 September 1996 Resolved
Post Garbage Pollution Placard on board vessel.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Lifesaving
Issued 17 September 1996 Resolved
Post emergency check-off list on vessel.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Accommodation/Occupational Safety
Issued 17 September 1996 Resolved
Install second toilet on board to bring total up to two (2) toilets.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Fire Fighting
Issued 17 September 1996 Resolved
Service two (2) B-II portable fire extinguishers that are past due.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Lifesaving
Issued 17 September 1996 Resolved
Mark proper number of life jackets in stowage area.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Engineering
Issued 11 September 1995 Resolved
Install missing 30 x 30 mesh flame screen in f/o tank gooseneck vents.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Construction/Loadline
Issued 11 September 1995 Resolved
Provide ventilation for hull spaces containing fuel oil tanks.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Documentation
Issued 11 September 1995 Resolved
Post oil pollution placard.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Accommodation/Occupational Safety
Issued 11 September 1995 Resolved
Post/lable maximum passenger limit on upper deck.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Documentation
Issued 11 September 1995 Resolved
Post copy of stability letter on bridge.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Lifesaving
Issued 11 September 1995 Resolved
Provide cradle for life float.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Fire Fighting
Issued 11 September 1995 Resolved
Show proof of hydrostatic testing of B-II fire extinguishers.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Lifesaving
Issued 11 September 1995 Resolved
Repair weathered cracking in ring bouys.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Documentation
Issued 11 September 1995 Resolved
Post emergency check off list on bridge.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Engineering
Issued 20 November 1992 Resolved
REPAIR OR REPLACE EXTENSIVELY CORRODED PORT AND STARBOARD DIESEL FUEL TANKS.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Documentation
Issued 16 September 1992 Resolved
CORRECT CURRENT ADDRESS OF OWNER ON CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Lifesaving
Issued 16 September 1992 Resolved
PROVIDE TWO PADDLES FOR LIFEFLOAT.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Engineering
Issued 16 September 1992 Resolved
INSTALL FLAME IMPINGEMENT SHIELDS ON FUEL FILTERS.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Documentation
Issued 16 September 1992 Resolved
PROVIDE FCC RADIO STATION LICENSE.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Lifesaving
Issued 16 September 1992 Resolved
INSTALL CG APPROVED WATER LIGHT ON LIFEFLOAT.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992

Casualty record · 4

14 October 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1695170
22 November 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6317279
22 November 2023Routine · role: Involved in a Marine Casualty · 1 injured · activity 7842672
9 January 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7871948
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.