Inspection history · 22
12 January 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7620412
1 December 2021
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7357044
1 December 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7361650
5 August 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7278786
30 October 2019
Internal Structural Exam · Welding Related Inspections Qualification Testing · Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6843408
1 October 2019
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6825227
30 August 2019
Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6810880
29 March 2019
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6651898
27 March 2019
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6650791
18 December 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6599742
18 December 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6616405
23 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6585624
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6513653
25 May 2018
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6423183
29 January 2018
Examination of Repairs · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6347183
11 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6119663
24 September 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6009776
26 August 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5987750
26 August 2016
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6012489
15 June 2016
Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5973502
27 January 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5860008
15 January 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5796965
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 1 December 2021
No resolution recorded
Except where specifically stated otherwise, an existing vessel must comply with the intact stability and seaworthiness regulations which were applicable to the vessel on March 10, 1996, or, as an alternative, the vessel may comply with the regulations in this part. Found the following items removed from the vessel: port and starboard air conditioning units on the bow, port and starboard sewage tanks in the lazarette, fresh water tank on the outside stern of the vessel. Resubmit stability calculations to the Marine Safety Center.
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 December 2021
No resolution recorded
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with 46 CFR 181.410, or other fixed fire extinguishing system specifically approved by the Commandant for a space containing propulsion machinery. Vessel is considered a new vessel due to lapse in Certificate of Inspection since 31 August 2019. 46 CFR 181.400(a)
Action required: 705 - Other - as specified
Due 1 March 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 December 2021
No resolution recorded
The following spaces must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76, except when a fixed gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed or when the space in manned. Vessel is a new vessel due to lapse in Certificate of Inspection since 31 August 2019. 46 CFR 181.405(a)
Action required: 705 - Other - as specified
Due 1 March 2022 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 October 2019
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations, internal structural examinations. Vessel has gone past their dry dock extension and is not cleared to operate until inspected by USCG Marine inspectors.
Subchapter T 46 CFR 176.600 (A)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2019
Resolved 30 October 2019
Resolution: Attended Hull/ISE.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 1 April 2019
Resolved
Each inlet or discharge pipe that penetrates the hull must have means to prevent water from entering the vessel. Rudder angle indicator in the starboard side aft space is not water tight at its through hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 15 April 2019
Resolution: Rubber boot was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 1 April 2019
Resolved
Each hatch on a watertight truck that extends 17 inches above the weather deck may be weather tight. Weather tight meaning, resisting water ingress. All vessel trunk hatch covers do not provide a weather tight seal requiring maintenance or readjusting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 15 April 2019
Resolution: Gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2019
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Both starboard and port shaft packing should be secured with double nuts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 15 April 2019
Resolution: Both shafts packing glands were double nutted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2019
Resolved
All cable and wire must be installed with metal supports. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations and not used as means of support. Overhead supports for electrical wires were plastic tie wraps and need to be replaced with metal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 15 April 2019
Resolution: Metal supports added.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 1 April 2019
Resolved
A vessel of more than 65 feet in length must be able to sufficiently maneuver and be arranged and equipped to allow the crew to recover a helpless person from the water. Vessel is equipped with rescue platform but does not have sufficient equipment to retrieve an unconscious person from the water onto the weather deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 15 April 2019
Resolution: Platform and rescue winch have been added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing machinery failure. While underway from San Juan to Cataño, the vessel suffered a transmission failure on the starboard engine due to three bolts on the coupling shearing. Must repair coupling prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2019
Resolution: Conducted sea trials and found repairs satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2018
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment suitable for the service in which they are to be employed. Overtightened governor on port side engine caused higher RPMs than expected, resulting in the vessel hitting the pier when manuevering. Must provide a technician's report attesting to the proper operation of the engine and its components.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 20 December 2018
Resolution: the technician loosened the governor on the port side engine and the RPMs slowed while the vessel was in idle.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 December 2018
Resolved
a hatch on a weathertight trunk that exceeds 12 inches above the weather deck must be weathertight. Port side aft hatch sustained damages preventing it from completing a weathertight seal. The seam along the deck compromised the trunk's weathertight integrity. Must providea repair proposal prior to starting repairs.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 20 December 2018
Resolution: the hatch was molded back into shape and the hatch cover fits snug.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 December 2018
Resolved
Gauges to indicate engine revolutions per minute(RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The vessel has two inoperable RPM gauges in the engine room space. Due to the fact that they are onboard, they should be operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2019
Resolved 1 April 2019
Resolution: All gauges were working properly during 2019 annual exam.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2019
Resolved 22 February 2019
Resolution: Vessel operator acknowledged the AIS discrepensy and provided proof from the AIS website.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2017
Resolved
VHF radio must be connected to a GPS receiver or have a VHF-DSC marine radio with integral GPS. The MMSI number must be also entered in the VHF radio. 47CFR80.
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 23 May 2017
Resolution: A new VHF-GPS ready radio was installed. All electrical connections were found satisfactory. Witness the proper operation of VHF radio.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 11 April 2017
Resolved
PFDs have Department of Transportation retroreflective material. Provide approved retro-reflective material on approximatley 20 PFDs.
46CFR160.055
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Resolution: Operator replaced PFDs with approved PFDs with the correct retroreflective material.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 April 2017
Resolved
Main diesel engines do not have covers on fly-wheels. Provide guards for moving parts.
46CFR176.830
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 25 April 2017
Resolution: Covers were installed in both port & stbdside engines.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 April 2017
Resolved
Ring life buoy with self-igniting water light on bow has department of transportation retro reflective tape. Provide approved retro tape.
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 11 April 2017
Resolution: Operator replaced retro-reflective tape on the ring bouy.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 April 2017
Resolved
MTWBs forward found open. Reseal MTWBs.
46CFR164.46
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2017
Resolved 11 April 2017
Resolution: Vessel sealed all MTWB's.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 24 September 2016
Resolved
Port side main diesel engine propulsion failed while vessel underway to Cataño Ferry Terminal. No passenger operations allowed until proper repairs are conducted to the satisfaction of USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2016
Resolved 26 September 2016
Resolution: Repair was conducted up to the satisfaction of CG Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 26 August 2016
Resolved
Properly correct dead-end wires at Stbdside next to the generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 27 August 2016
Resolution: Cables were isolated in a junction box.
Electrical › Electric Supply System (service) › Cable
Issued 26 August 2016
Resolved
All electrical wiring needs to be protected from shaffing and heat sources as indicated during the inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 29 August 2016
Resolution: Cables were secured from heat sources and protected from shaffing.
Electrical › Electric Generation Source (service) › Generator
Issued 26 August 2016
Resolved
Properly correct minor oil leak from the generator valve cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 27 August 2016
Resolution: A missing breather discharge hose was installed to collect the oil.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 August 2016
Resolved
Bilges needs to be cleaned of debris.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 29 August 2016
Resolution: Bilges were cleaned of debris and oily residues and collected in oil drums for disposition.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 August 2016
Resolved
Both port & stbd engine room hatch access must be repaired to prevent the admission of air in the space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 29 August 2016
Resolution: Both hatch covers were repaired preventing the passing of air.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 August 2016
Resolved
All captains and crew members shall demonstrate proficiency and competency during performance of drills to the satisfaction of USCG MI in: Abandon ship, Man Over Board, Fire and Emergency broadcasting.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2016
Resolution: All Crew were trained in Emergency Broadcasting, abandon ship, fire and man over board and practiced to the satisfaction of an attending USCG Marine Inspector present.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 August 2016
Resolved
All captains and crew members shall demonstrate proficiency and competency during performance of drills: MOB, Abandonship, Fire and Emergency Broadcasting. Drills must be logged and documented IAW 46CFR 185.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2016
Resolution: 3rd party contracted trainer, provided training to all captains and crew; and USCG marine Inspector witnessed and practiced all drills on board vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 27 January 2016
Resolved
Prove proper opertions of both main diesel engines.
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 29 August 2016
Resolution: Conducted a 1.5 hrs sea trial on board the vessel and both engines performed successfully.