HOPPER II

HOPPER II is a 1989 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1990, most recently in May 2025, along with 111 deficiencies.

Records from 1990 to 2025. Most recent: inspection, 14 May 2025.

Built
1989
Last inspected
14 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAK4524
339985
Flag
UNITED STATES
—
Maury page id
psix-339985

Inspections, by type

…with no type recorded4
Years with a record 31 calendar years (1990–2025)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.5 ft × 6.4 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER BOATS, INC · FT PIERCE FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portZEPHYR COVE, NV
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 30 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAK4524MMSI not assigned · expired · compulsorily equipped · granted 7 February 1995, cancelled 18 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 55

14 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8127443
25 April 2025 Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8117384
14 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7910073
27 June 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7721922
3 May 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7437687
27 April 2021 Drydock Exam · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182365
12 May 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949178
30 April 2020 Drydock Extension · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946517
10 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681291
11 June 2018 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441499
24 April 2018 Simplified Stability Test · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6398257
8 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6146934
26 April 2016 COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5862914
18 July 2012 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4412953
13 June 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4334525
4 May 2009 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3464000
7 April 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3179336
31 May 2007 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2952262
31 May 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2953630
4 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2640719
4 May 2005 Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2355020
11 May 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2071699
11 May 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2249863
1 April 2003 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1751909
29 March 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1597464
15 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075586
18 May 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1066875
24 April 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379392
27 July 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 821199
24 July 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 819985
28 June 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1361600
22 May 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1410334
27 July 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1107583
4 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 794065
29 March 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1081046
1 March 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804771
20 May 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126968
20 April 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469512
31 March 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092314
16 July 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092941
8 May 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1363707
20 June 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1190889
1 May 1995 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227847
14 July 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868469
30 June 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170855
26 May 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170745
25 May 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150065
23 July 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954138
26 June 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945464
20 August 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257031
17 June 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923397
9 January 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1217370
21 May 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219571
23 March 1990 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1291357
7 March 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1236318

Deficiency record · 111

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2025 Resolved
An adult life jacket must be provided for each person carried onboard a vessel. Identified 1 lifejacket missing clasp to secure it. Vessel is restricted to carriage of 9 passengers until rectified. 46 CFR 180.71
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 May 2025
Resolved 21 May 2025
Resolution: Received photos of replacement life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025 Resolved
Each item of lifesaving equipment determined by the MI to not be in serviceable condition must be repaired or replaced. Identified holes in life ring buoy. Replace to satisfaction of MI. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 21 May 2025
Resolution: Satisfactorily replaced life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 May 2025 Resolved
Each item of lifesaving equipment determined by the MI to not be in serviceable condition must be repaired or replaced. Identified cracked paddles and cracks in life float. Repair life float with manufacturer repair kit and replace paddles to satisfaction of MI. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 21 May 2025
Resolution: Replaced paddles and made repairs to life float
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 May 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired. Vessel's lifefloat shows signs of cracking. Lifefloat to be repaired with manufacturer repair kit. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 July 2024
Resolution: Lifefloat repaired with [name withheld] repair kit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2024 Resolved
Through hull fittings and shutoff valves must be metallic. Through hull fitting was found to be non-metallic on port side of vessel. Correct deficiency prior to credit drydock. 46 CFR 182.720(d)(3)
Action required: 705 - Other - as specified
Resolved 26 April 2025
Resolution: MI verified required thruhulls have been replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 May 2020 Resolved
A preengineered fixed gas fire extinguishing system must be installed in accordance with the manufacturers instructions. Wiring harness connecting to pre-engineered fixed gas extinguisher was found cracked. 46 CFR 181.420 (a)(4)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2020
Resolution: Pre-engineered fire extinguishing system replaced in kind.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 May 2020 Resolved
A visual and audible alarm must be provided at the operating station. Engine room highwater alarm was found inoperable. 46 CFR 182.530 (a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2020
Resolution: Alarm was replaced and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 May 2020 Resolved
Vessels on a lakes, bays, sounds and rivers route must carry flares as required in 180.68 (b). No flares onboard vessel. 46 CFR 180.68 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2020
Resolution: No distress signals provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2020 Resolved
Each life ring buoy onboard a vessel must be fitted with a lifeline and a waterlight with lanyard and clip. Waterlight was found with bulge in side and lanyard was parted. Life ring buoy lifeline was found rotted and coming apart.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2020
Resolution: Ring Buoy and light replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2020 Resolved
Each lifefloat must be fitted with 2 paddles. Lifefloat was missing one paddle. Existing paddle is cracked and needs replacement. 46 CFR 180.175 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2020
Resolution: Two paddles provided for life float.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2020 Resolved
Battery connections must be made to battery terminals with permanent type connections. Battery cables connected with wing nuts. 46 CFR 183.350 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2020
Resolution: Battery connections installed with nuts and lock washers.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2020 Resolved
Placards containing instructions for donning lifejackets must be posted in conspicuous places. Life jacket placard did not demonstrate the correct type of lifejacket carried onboard. 46 CFR 185.516 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2020
Resolution: Life jacket donning instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019 Resolved
Ring Buoy lanyard deteriorated. Floating light damaged not watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2019
Resolved 13 May 2019
Resolution: Ring Buoy and floating light replaced on the spot.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 June 2018 Resolved
Provisions shall be made by means of plugs, covers, etc to prevent admission of air into the space protected. Means are not readily available to secure ventilation to engine room space. 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 10 July 2018
Resolution: Plugs provided next to air intakes for Engineroom.
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 June 2018 Resolved
Shutoff valves shall be installed as to close against the fuel flow. Emergency Fuel Shutoff Valve does not adequately close when pulled. 46 CFR 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 10 July 2018
Resolution: New valve installed for fuel tank. Tested Sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 June 2018 Resolved
Suitable covers, guards shall be installed in way of exposed and hazardous places. Turbo is not covered with exhaust lagging. 46 CFR 177.35-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 21 August 2018
Resolution: Exhaust Lagging installed on exhaust side of turbo.
Lifesaving › Lifefloat › Paddle
Issued 8 May 2017 Resolved
Label life float paddles with vessel name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 May 2017
Resolution: Corrected on the spot.
Fire Fighting › Fire Bucket › Stenciling
Issued 8 May 2017 Resolved
Label fire buckets.
Condition: Improper Installation
Due 8 June 2017
Resolved 8 May 2017
Resolution: Corrected on the spot.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 May 2017 Resolved
All portable fire extinguishers shall be mounted in brackets. 46CFR181.520
Condition: Improper Installation
Due 8 June 2017
Resolved 9 May 2017
Resolution: Observed properly mounted brackets for portable fire extinguishers.
Engineering › Fuel Oil Service System › Hose
Issued 3 May 2016 Resolved
Return Fuel system connectoin at engine fuel injector to flexible hose loose and leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Operator tightened all fuel injector union connections to flexible reurn hose. Mounted flexible hose in manner which relieved stress to connecting fittings. Operated engine and observed no leaks.
Lifesaving › Lifefloat › Serviceable
Issued 13 June 2012 Resolved
Make proper repairs to life float. 46CFR180.15
Due 22 June 2012
Resolved 18 July 2012
Resolution: Made proper repairs to LF using approved repair kit
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 June 2012 Resolved
Provide approved lifeline for life ring. 46CFR180.70
Due 22 June 2012
Resolved 18 July 2012
Resolution: Provided approved lifeline for life ring buoy
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2012 Resolved
Provide ammonia inhalants and burn cream to first aid kit. 46CFR184.710
Due 22 June 2012
Resolved 18 July 2012
Resolution: Provided ammonia inhalants and burn cream to onboard first aid kit.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2012 Resolved
Provide approved hand bilge pump. 46CFR182.520
Due 22 June 2012
Resolved 18 July 2012
Resolution: Provided approved hand bilge pump, attending MI''s witnessed operational test
Lifesaving › Hand Flares › Storage
Issued 13 June 2012 Resolved
Provide colored flares container. 46CFR180.68
Due 22 June 2012
Resolved 18 July 2012
Resolution: Provided new brightly colored container for flares
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 June 2012 Resolved
Provide sound signal. 33CFR86.05
Due 22 June 2012
Resolved 18 July 2012
Resolution: Provided sound signal device
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 October 2009 Resolved
Update all items in first aid kit that are expired
Action required: 705 - Other - as specified
Due 19 October 2009
Resolved 19 October 2009
Resolution: Bought a new First Aid Kit.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 5 October 2009 Resolved
Renew/Replace STBD side B-II fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2009
Resolved 19 October 2009
Resolution: Replaced valve on portable F/E.
Communications › Audible Communications › Horn/Whistle
Issued 4 May 2009 Resolved
Horn/Whistle - Missing
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 5 October 2009
Resolution: Replaced sound producing device.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 4 May 2009 Resolved
Renew/repair stbd aft fire extingusisher due to lack of pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 5 May 2009
Resolution: Mater replaced extinguisher with like kind.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 4 May 2009 Resolved
Replace port bow fire extinguisher bracket with correct size to prpoerly fit extinguisher
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 5 May 2009
Resolution: Corrected bracket with proper size
Engineering › Steering Gear System › Rudder Stock
Issued 4 May 2009 Resolved
Renew/replace rudder packing due to excessive leaking into bilge.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 5 October 2009
Resolution: Replaced rudder packing.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 7 April 2008 Resolved
Install fuse protection on all current carrying conductors (positive) wires at the battery, IAW 46 CFR 183.380.
Due 9 April 2008
Resolved 10 April 2008
Lifesaving › Lifefloat › Painter
Issued 7 April 2008 Resolved
Repack lifefloat painter so it pays out freely IAW 46 CFR 180.137.
Due 9 April 2008
Resolved 10 April 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 April 2008 Resolved
Renew retro reflective tape on ringbouy as required by 46 CFR 160.050
Due 9 April 2008
Resolved 10 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
No company policy.
Condition: Unknown
Due 5 July 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
Drug testing history checks were not being completed.
Due 5 July 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
Company not using a statistically based method to determine who will be randomly tested. Need to use a random number generator or similar program.
Due 5 July 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
No EAP policy is posted.
Due 5 July 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
Supervisors have not received 1 hr of required EAP training.
Due 5 July 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
Employer does not have a Substance Abuse Professional's name and contact information.
Due 5 July 2007
Resolved 17 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007 Resolved
No record of the MIS report being submitted annually.
Due 5 July 2007
Resolved 17 March 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 May 2006 Resolved
Prove proper operation of Emergency fuel oil shutoff valve.
Due 8 May 2006
Resolved 10 May 2006
Operations/Management › Non-double Hull Tank Barges › Emergency Steering Capability
Issued 4 May 2006 Resolved
Prove proper operation of Emergency steering tiller.
Due 8 May 2006
Resolved 10 May 2006
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 4 May 2006 Resolved
Outfit first aid kit In accordance with 46 CFR 184.710
Due 8 May 2006
Resolved 10 May 2006
Engineering › Bilge Water Management System › Valve
Issued 4 May 2005 Resolved
Install a metallic positive shut off valve near the hull penetration for the electric bilge pump overboard piping IAW 46CFR182.520
Due 4 July 2005
Resolved 31 May 2007
Construction/Loadline › Structures › Superstructure
Issued 4 May 2005 Resolved
Renew the wood rot in the lazarette overhead. This must be done for credit drydock.
Action required: 705 - Other - as specified
Due 4 July 2005
Resolved 4 May 2005
Construction/Loadline › Hull › Keel
Issued 4 May 2005 Resolved
Repair spots on the keel as identified IAW NVIC 8-87. This must be done for credit drydock.
Action required: 705 - Other - as specified
Due 4 July 2005
Resolved 4 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 4 May 2005 Resolved
Make sea valves available for inspection.
Due 4 July 2005
Resolved 4 May 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 May 2004 Resolved
Repair all cracks in life floats per manufacturer's instructions. Vessel is restricted from carrying passengers more than 1 nautical mile from shore until repairs are made. LEGACY COMPONENT DESC: Life Float
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 2 May 2005
Lifesaving › Buoyant Apparatus
Issued 11 May 2004 Resolved
Renew all grab lines. LEGACY COMPONENT DESC: Life Float
Action required: 705 - Other - as specified
Resolved 14 May 2004
Resolution: Re-newed grab lines.
Lifesaving › Buoyant Apparatus
Issued 11 May 2004 Resolved
Install missing screw to life float water light. LEGACY COMPONENT DESC: Water Light
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 14 May 2004
Resolution: Installed screw.
Lifesaving › Buoyant Apparatus
Issued 11 May 2004 Resolved
Label life float paddles with vessel's name. LEGACY COMPONENT DESC: Paddles
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 14 May 2004
Resolution: Labeled life float paddles.
Stability › Weathertight Integrity
Issued 11 May 2004 Resolved
Make engine space weather tight in way of water dripping from port and starboard gunnels. LEGACY COMPONENT DESC: Engine Space
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 14 May 2004
Resolution: Sealed weather deck satisfactorily on both port and starboard gunnels above engine space.
Stability › Watertight Integrity
Issued 11 May 2004 Resolved
Correct excessive shaft leakage. LEGACY COMPONENT DESC: Engine Space
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2004
Resolution: Tighted shaft packing glands to stem leakage.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2004 Resolved
Install marine grade wiring along port gunnel for down riggers per ABYC electrical standards. Existing wire was house-hold wire and not marine grade. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 4 May 2005
Stability › Watertight Integrity › General
Issued 11 May 2004 Resolved
Repair bow peak fracture at rub rail. Fracture was located several feet above water line and temporary repair will be accepted until next hull examination. Bow peak permanent repair shall be completed at next hull exam. Vsl is restricted from carrying passengers until temporary repairs are made. LEGACY COMPONENT DESC: Bow Peak
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 4 May 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 May 2004 Resolved
Provide PFD instruction placard. LEGACY COMPONENT DESC: Instruction Placard
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 14 May 2004
Resolution: Provided placard.
Fire Fighting › Ventilation Systems › Ducts
Issued 11 May 2004 Resolved
Provide proper means to secure ventilation to engine space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2004
Resolution: Installed closure panels for both port and starboard wire runs on aft crew cabin bulkhead.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 May 2004 Resolved
Provide proof of training to crew for all vessels (Hopper I, Hopper II, Hopper III, and Prophet)
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 4 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 11 May 2004 Resolved
Install SAE J1942 approved fuel hoses for engine fuel system in way of hoses connected to fuel oil filter. LEGACY COMPONENT DESC: Fuel Hoses
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2004
Resolved 4 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 May 2004 Resolved
Install approved raw water hose connected from engine to wet exhaust elbow. LEGACY COMPONENT DESC: Raw Water Hose
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 4 May 2005
Documentation › Certificates/Documents
Issued 2 April 2003 Resolved
Properly post COI and Stability Letter.
Due 1 May 2003
Resolved 20 May 2003
Resolution: Posted COI and Stability Letter.
Lifesaving › Lifebuoys
Issued 2 April 2003 Resolved
Properly add retroreflective material to life rings.
Due 1 May 2003
Resolved 20 May 2003
Resolution: Retro-flective tape was properly affixed to life rings.
Lifesaving
Issued 2 April 2003 Resolved
Replace waterlight batteries.
Due 1 May 2003
Resolved 20 May 2003
Resolution: Waterlight batteries re-placed with non-expired batteries.
Lifesaving
Issued 2 April 2003 Resolved
Make lifefloat float free by removing weaklink and tie-down system or by replacing weaklink with hydrostatic release. Limited to one mile from shore until complete.
Due 1 May 2003
Resolved 20 May 2003
Resolution: Lifefloat is float free.
Lifesaving
Issued 2 April 2003 Resolved
Move location of weaklink attached to lifefloat painter so line will apply pressure to weaklink when payed out. Vessel limited to one mile from shore until complete.
Due 1 May 2003
Resolved 20 May 2003
Resolution: Weaklind moved to correct location.
Lifesaving › Lifebuoys
Issued 2 April 2003 Resolved
Provide corrosion-resistant clip for waterlight.
Due 2 April 2003
Resolved 2 April 2003
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 March 2002 Resolved
Separately stow and label stowage area for children's life jackets.
Due 29 March 2002
Resolved 29 March 2002
Communications › Radio Communications
Issued 29 March 2002 Resolved
Post Emergency Broadcast Placard in vicinity of VHF-FM Radio
Due 29 March 2002
Resolved 29 March 2002
Lifesaving › Hand Flares › Storage
Issued 29 March 2002 Resolved
Stow flares in brightly colored watertight container marked distress signals.
Due 29 March 2002
Resolved 29 March 2002
Operations/Management › Drills/Instruction
Issued 29 March 2002 Resolved
Conduct first aid/ CPR Training
Due 30 April 2002
Resolved 20 May 2003
Resolution: Provided first aid and CPR cards.
Stability › Watertight Integrity
Issued 29 March 2002 Resolved
Small hole from zinc fitting, port side, under exhaust left un-plugged. Temporary fix approved, to be permanently repaired 02Apr02. Permanent repairs to be examined by attending marine inspector.
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 13 June 2018
Resolution: Permanent repair accomplished by applying fiber glass and epoxy over hole. Verified permenant repairs.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 29 March 2002 Resolved
Conduct Annual servicing on E/R fixed fire fighting system.
Due 29 March 2002
Resolved 29 March 2002
Engineering
Issued 24 April 2001 Resolved
Ensure proper operation of emergency fuel shutoff valve system (frozen cable) prior to operating with passengers.
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Lifesaving
Issued 24 April 2001 Resolved
Improper weak link and deteriorated painter line. Install new painter and weak link for lifesaving appliance (lifefloat) prior to 24 May 01.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Lifesaving
Issued 24 April 2001 Resolved
Replace ring buoy (deteriorated condition) prior to operating with passengers.
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Fire Fighting
Issued 24 April 2001 Resolved
Conduct annual service for fixed firefighting system in engine compartment prior to operating with passengers.
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Construction/Loadline
Issued 28 June 2000 Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARM (46 CFR 182.530)
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Construction/Loadline
Issued 28 June 2000 Resolved
PLUG HOLE IN DECK ABOVE LAZARETTE.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Navigation
Issued 28 June 2000 Resolved
POST EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 28 June 2000
Resolved 21 July 2000
Construction/Loadline
Issued 4 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN ACCORDANCE WITH 46 CFR 182.530
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Lifesaving
Issued 20 April 1998 Resolved
PROVIDE AND POST LIFE JACKET DONNING PLACARD IAW 46CFR185.516.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
RENEW WASTED GRAB LINES ON BUOYANT APPARATUS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 20 April 1998 Resolved
STENCIL VESSEL NAME AND CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT IN ACCORDANCE WITH 46CFRA84.710.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Fire Fighting
Issued 20 April 1998 Resolved
PERFORM ANNUAL SERVICING ON PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 8 May 1996 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR RING BUOY.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996 Resolved
PROVIDE POSTED LIFEJACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996 Resolved
PROVIDE SIX ORANGE FLARES.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Documentation
Issued 1 May 1995 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Navigation
Issued 1 May 1995 Resolved
REDUCE MAGNETIC COMPASS ERROR AND PROVIDE UPDATED DEVIATION TABLE.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Documentation
Issued 1 May 1995 Resolved
PROVIDE COPY OF 46 CFR PARTS 166-199 (SUBCHAPTER "T").
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Documentation
Issued 1 May 1995 Resolved
PROVIDE CURRENT COPY OF RULES OF THE ROAD.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Navigation
Issued 1 May 1995 Resolved
RAISE HEIGHT OF ALL-AROUND WHITE NAVIGATION LIGHT TO ATTAIN FULL ARC OF VISIBILTY.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Electrical
Issued 1 May 1995 Resolved
REWIRE REMOTE CONTROL WIRING TO OUTBOARD TROLLING MOTOR.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Engineering
Issued 30 June 1994 Resolved
BROKEN EMERGENCY FUEL STOP CABLE NEEDS TO BE REPLACED.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Documentation
Issued 30 June 1994 Resolved
REWRITE DRUG TEST PROGRAM IAW DISCUSSION HELD WITH MARINE INSPECTORS ON 30 JUN 94.
Condition: Unknown
Due 30 June 1994
Resolved 18 July 1994
Navigation
Issued 30 June 1994 Resolved
REPAIR OR REPLACE BULB/LIGHT FOR STERN LIGHT.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 25 May 1993 Resolved
MAKE AFT HATCH WATER TIGHT. (RENEW GASKET)
Condition: Unknown
Due 25 June 1993
Resolved 13 July 1993
Construction/Loadline
Issued 25 May 1993 Resolved
PROVE OPERATION OF FIXED HAND BILGE PUMP.
Condition: Unknown
Due 25 June 1993
Resolved 13 July 1993
Documentation
Issued 26 June 1992 Resolved
MOUNT O/B ENGINE GAS CAN OVER SWIM PLATFORM. MARK GAS TANK AREA AS NO SMOKING AREA.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Unknown
Issued 26 June 1992 Resolved
CLEAN HYDRAULIC OIL FROM AFT COMPARTMENT.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Construction/Loadline
Issued 26 June 1992 Resolved
REPAIR OR REPLACE, THEN TEST INSTALLED HAND BILGE PUMP. COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Construction/Loadline
Issued 26 June 1992 Resolved
PROVIDE ADEQUATE LENGTH OF SUCTION HOSE FOR PORTABLE HAND PUMP.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Unknown
Issued 26 June 1992 Resolved
TIGHTEN LEAKING HYDRAULIC FITTING IN AFT COMPARTMENT.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Documentation
Issued 17 June 1991 Resolved
MOUNT MARPOL V PLACARD WHICH DESCRIBES RULES REGARDING THE DISPOSING OF WASTES/PLASTICS IN THE WATER.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Documentation
Issued 17 June 1991 Resolved
PRODUCE WASTE MANAGEMENT PLAN AND KEEP ABOARD THE VESSEL.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Fire Fighting
Issued 17 June 1991 Resolved
PROVIDE/ATTACH HOSE ON HAND FIRE PUMP OF SUFFICIENT LENGTH TO REACH ANY LOCATION ON THE VESSEL.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Navigation
Issued 17 June 1991 Resolved
MOUNT EMERGENCY TILLER IN AREA THAT IS READILY ACCESSABLE.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Engineering
Issued 17 June 1991 Resolved
CLEAN FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.