Records from 2016 to 2025. Most recent: inspection, 30 May 2025.
Inspection history · 8
30 May 2025
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8148314
24 June 2022
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7489472
6 May 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7170936
15 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7108900
24 July 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6754988
19 July 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6485322
12 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6123890
22 April 2016
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5860357
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 May 2021
Resolved
Four out of six automatic bilge pumps located in the pontoon assemblies (port-aft, center-aft, stbd-fwd/aft) are non-functional. Demonstrate proper functioning of the automatic bilge pumps as well as visual indication of the pumps at the operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2021
Resolved 8 June 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 May 2021
Resolved
Vessel's portable fire extinguishers are past due for annual servicing. Provide documentation for annual servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2021
Resolved 8 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2021
Resolved
Vessel is required to have one B-I and one B-II approved portable fire extinguishers, as listed on the COI. Vessel currently has two B-Is and no B-II. Provide proof that vessel possesses, at a minimum, one B-I and one B-II approved portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2021
Resolved 8 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021
Resolved
The 8" long x 1 1/2" diameter flexible fuel fill hose is cracked and deteriorated. Replace fuel fill hose. In addition; repair and/or replace cracked fuel fill housing associated with the fuel fill hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 8 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2019
Resolved
Vessel does not have the required compliment of fire buckets. Provide at least 3 (2.5 gallon) buckets with attached lanyards, in a readily available location, in case of fire. Each bucket must be stenciled with "FIRE BUCKET" in a contrasting color.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2019
Resolved 25 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2019
Resolved
Ring-lifebuoy is not fitted with reflective tape. Fit ring-lifebuoy with Type-I retrofreflective material as instructed by the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 25 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2019
Resolved
Starting battery is not secured to protect against shifting and is not mounted in a tray to protect vessel against leaked electrolyte. Properly mount battery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2019
Resolved 25 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2019
Resolved
The port-aft submersible electric bilge pump is not operational. Demonstrate proper operation of pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 25 August 2019
Resolution: Loose wire discovered.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 July 2019
Resolved
Emergency Instruction List is not mounted at the operating station. Mount Emergency Instruction List.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 25 August 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 July 2018
Resolved
Monthly man-overboard (MOB) drills not documented in vessel's logbook. Provide evidence that monthly MOB drills are being conducted and logged IAW 46 CFR 185.520.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 24 July 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 July 2018
Resolved
Monthly fire drills not documented in vessel's logbook. Provide evidence that monthly fire drills are being conducted and logged IAW 46 CFR 185.524.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 24 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2018
Resolved
Vessel is required to have one B-I and one B-II portable fire extinguishers. Vessel currently has two B-I's, and the B-II is missing. Provide one B-II portable fire extinguisher in stern area IAW 46 CFR 181.500.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2018
Resolved 24 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2018
Resolved
Vessel's ring lifebuoy is deteriorated and not outfitted/installed correctly. Provide new ring lifebuoy and install, outfit, and mark IAW 46 CFR 180.70 and 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2018
Resolved 24 July 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 July 2018
Resolved
Emergency Instruction List not posted, or carried, on vessel. Post (or carry onboard) Emergency Instruction List IAW 46 CFR 185.510.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 24 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 July 2018
Resolved
When testing automatic bilge pumps in the vessel's pontoons, it was discovered that the visual indicator lights at the operating console only intermittently flickered. Demonstrate that when any automatic bilge pump is running that a visual indication is evident at the operating console IAW 46 CFR 182.530(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 24 July 2019