Records from 2016 to 2026. Most recent: inspection, 17 January 2026.
Inspection history · 17
17 January 2026
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8296586
3 December 2025
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8277019
25 March 2025
PSC A
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8097726
27 September 2024
Polar Code Examination · PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8004296
26 January 2024
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7851940
10 May 2023
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7679703
6 October 2022
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7572446
18 October 2021
Ballast Water Examination · Deficiency Check · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7323880
17 July 2020
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7007293
23 October 2019
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6840384
8 October 2019
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6830607
25 January 2019
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6614733
1 February 2018
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6340114
12 May 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6144809
27 July 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5955150
28 January 2016
PI Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5803786
15 January 2016
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5798466
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2025
Resolved
Cylinders when not in use, they must be stowed in a rack, upright position, with the valve protection cap in place. PSCO observed cylinders were stowed without protection caps in place.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 April 2025
Resolved 8 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 October 2021
Resolved
SOLAS 74(2004) CH. II-2/4.1.1 CODE 0750
MEANS SHALL BE PROVIDED TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE THE FOLLOWING FUNCTIONAL REQUIREMENTS MUST BE MET; MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. THE #2 AUX. GENERATOR WAS EXESSIVLY LEAKING FIEL OIL CREATING A FIRE HAZARD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: RECIEVED CLASS REPORT ATTESTING TO SATISFACTORY REPAIRS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 October 2021
Resolved
SOLAS74(1997) CH.II-2/47.1 CODE 0910
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GAS TIGHT AND SELF-CLOSING. MAIN ENGINE ROOM DOOR FAILED TO CLOSE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 19 October 2021
Resolution: RECIEVED CLASS REPORT ATTESTING TO OPERATIN OF DOOR.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 October 2019
Resolved
07110 - Fire fighting equipment and appliances - A fireman's outfit shall consist of a breathing apparatus of an approved type which shall be capable of functioning for at least 30 mins.
SCBA mask is leaking air and will not be able to supply 30 minutes of air.
- 74 SOLAS 97 cons. II-2 Reg 17.1.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2019
Resolved 23 October 2019
Resolution: Performed maintenance on SCBA masks, operating correctly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 January 2019
Resolved
Means of escape systems and appliances shall be kept in good order so as to ensure their required performance if a fire occurs. Doggs on watertight doors were found not in working order. SOLAS 74(14cons)II-2/14.2.1.1.3 40a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 January 2019
Resolved 8 April 2019
Resolution: Vessel submitted Class report and pictures attesting to all the WTDs
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 25 January 2019
Resolved
Fire control plans and booklets shall be kept up to date. The fire control plan does not accurately depict fire boundaries and doors between the galley and crew mess.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 January 2019
Resolved 9 April 2019
Resolution: Recieved Class report attesting to the Fire Control Plan