BLUE HERON II

BLUE HERON II is a 1989 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1990, most recently in December 2025, along with 60 deficiencies and 1 casualty investigation in 2008.

Records from 1990 to 2025. Most recent: inspection, 16 December 2025.

Built
1989
Last inspected
16 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ8676
340746
Flag
UNITED STATES
367324820
Maury page id
psix-340746

Inspections, by type

…with no type recorded3
Years with a record 29 calendar years (1990–2025)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENTERPRIS · LOREAUVILLE LA · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portRIVIERA BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8786MMSI 367324820 · active · compulsorily equipped · granted 17 January 2018, expires 17 January 2028
WBP8076MMSI 367324820 · terminated · compulsorily equipped · granted 29 November 2007, cancelled 9 January 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 51

16 December 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8284334
12 November 2025 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8267455
16 December 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8048051
7 December 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7835858
16 November 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7825914
7 December 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7605459
1 November 2021 Construction Oversight · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7343273
9 September 2021 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7308093
7 January 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7120932
20 December 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6877188
8 October 2019 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6830636
20 December 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6600675
9 January 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6334552
14 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6306401
14 October 2016 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6022276
7 December 2015 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5776452
4 November 2015 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5756976
15 November 2010 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3891420
10 December 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3377411
25 November 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3369927
25 November 2008 Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3371953
25 January 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3136220
13 November 2007 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3097415
26 October 2006 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2794897
8 February 2006 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2581435
10 January 2006 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2568767
8 November 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2530605
9 December 2004 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2256113
1 March 2004 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2015450
13 November 2003 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1935010
19 November 2002 Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1708417
25 October 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1379603
22 October 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1382421
13 December 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450382
10 November 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378865
24 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116565
9 November 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429052
12 November 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113316
5 November 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777754
9 December 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092222
18 December 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871978
26 October 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879168
17 November 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180606
9 December 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158137
14 October 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 837125
15 December 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828677
12 November 1991 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940571
8 May 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306813
8 January 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1240817
18 May 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225839
5 January 1990 Hull Examination · Plan Review "T" Boat · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223525

Deficiency record · 60

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 December 2025 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate Of Documentation. COD expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2025
Resolution: Provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 December 2025 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis. Consortium letter is not current. Swabs are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2025
Resolution: Provided.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 16 December 2025 Resolved
Every vessel subject to Part III of Title II of the Communications Act must have a detailed inspection of the radio installed by an FCC-licensed technician in accordance with 80.59, once every five years. Vessel has bridge-to-bridge certificate but is missing Safety Radiotelephony Certificate. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2026
Resolution: Provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 December 2024 Resolved
The marine employer must have sufficient alcohol testing devices readily accessible. Devices expired. Vessel must be able to conduct alcohol tests within 2 hours.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 December 2024
Resolution: Provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 December 2024 Resolved
An EAP program must include the following elements: Supervisory personnel must receive at least 60 minutes of training. No proof of training provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2023 Resolved
If garden hose is used, it shall be of a good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer rubber cover or of equivalent material, and shall be fitted with a good grade bronze or equivalent metal. Current hose on vessel is not of commercial grade. 46 CFR 181.15-10(e) Old T.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 8 December 2023
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 December 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot [name withheld] List, Tide tables, and Current tables. Charts not up-to-date and pubs are missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 8 December 2023
Resolution: Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2022 Resolved
Battery terminals to cable connections loose. Connectors to be replaced. 46 CFR 183.350
Action required: 705 - Other - as specified
Resolved 14 December 2022
Resolution: Connectors replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 September 2021 Resolved
Due to the freeboard of the vessel, a retrieval system is required to safely bring a man overboard on board. Install a satisfactory retrieval system to the satisfaction of marine inspector. 46 CFR 185.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 23 December 2021
Resolution: Satisfactory swim platform provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 January 2019 Resolved
Provide current FCC Station License. Restricted to no more than 1000 feet from shore. 47 CFR 80.13
Action required: 705 - Other - as specified
Resolved 8 January 2019
Resolution: Current station license provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 January 2019 Resolved
Prove proper operation of bilge high level visual alarm for fuel tank space. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2019
Resolution: Visual alarm functions SAT.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 January 2019 Resolved
Replace expired hydro-static release unit. Restricted to no more than 3 NM from shore. 46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 8 January 2019
Resolution: HRU replaced and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2019 Resolved
Replace wasted emergency fuel shut off valve handle in engine room. 46 CFR 182.440
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2019
Resolution: Valve handle replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2019 Resolved
Separate and label child life jackets. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2019
Resolution: Life jackets separated from adult life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2019 Resolved
Post emergency instructions. 46 CFR 185.510-512
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 18 January 2019
Resolution: Emergency instruction posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2019 Resolved
Move one ring buoy to main deck. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 18 January 2019
Resolution: Ring buoy moved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2019 Resolved
Label breakers in breaker panel. 46 CFR 183.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 18 January 2019
Resolution: Breakers labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2019 Resolved
Remove of cap exposed wire in void space. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 18 January 2019
Resolution: Wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2019 Resolved
Provide permanent type connectors to battery cables at terminals. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 18 January 2019
Resolution: Lock washers added.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 October 2016 Resolved
Provide current crew list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Provided current crew list.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 October 2016 Resolved
Label high water alarms.
Due 18 November 2016
Resolved 31 October 2016
Resolution: Labeled high water alarms.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 October 2016 Resolved
Prove proper operation of stern light prior to night time operations.
Due 14 November 2016
Resolved 31 October 2016
Resolution: Proved proper operqation of stern light.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 October 2016 Resolved
Provide current alcohol swabs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Provided current alcohol swabs.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 October 2016 Resolved
Provide current MIS report.
Due 14 November 2016
Resolved 25 October 2016
Resolution: Provided current MIS report.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 October 2016 Resolved
Provide current consortium enrollment form.
Due 25 October 2016
Resolved 25 October 2016
Resolution: Provided current enrollment form.
Engineering › Bilge Water Management System › Piping
Issued 25 November 2008 Resolved
Bulkhead penetration for bilge/ fireman piping was wasted through. Found steel piping threaded into aluminum fitting. Aluminum fitting wasted through at bottom.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 November 2008 Resolved
Prior to operating, remove all oil and oily mixtures from engine room.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 November 2008 Resolved
Prior to operating, remove all oil and oily mixtures from engine room.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2008
Construction/Loadline › Hull › Bottom Plating
Issued 13 November 2007 Resolved
Found area of hull that was corroded due to exhaust gases. Vessel has exhaust leading to an area under the hull amid ship where it leaves the vessel between bilge strake and keel. Directed owner to provide drawings for approval prior to cropping out the area of concern, addressing the damage. After drawing is approved the owner will crop out and install new approved aluminum material.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 30 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2006 Resolved
Stbd side sewage pumps must be properly wired
Condition: Improper Installation
Due 10 November 2006
Resolved 13 November 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 October 2006 Resolved
Provide corrosion resistent clip for float free- light on stbd topside rlb.
Condition: Improper Installation
Due 10 November 2006
Resolved 13 November 2007
Lifesaving › Hand Flares › Not on Board
Issued 26 October 2006 Resolved
Provide 3 orange smoke flares
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2007
Resolved 13 November 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 October 2006 Resolved
Install a/v alarms at pilothouse for each watertight compartments
Condition: Improper Installation
Due 10 November 2006
Resolved 13 November 2007
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 26 October 2006 Resolved
Renew generator fuel hose
Due 10 November 2006
Resolved 13 November 2007
Stability › Watertight Integrity › General
Issued 26 October 2006 Resolved
Secure and make watertight ER hatch
Due 10 November 2006
Resolved 13 November 2007
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 8 February 2006 Resolved
Provide proof of compliance with chemical testing and EAP training requirements.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2006
Resolved 13 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2006 Resolved
Properly connect wires in fuel holding tank room with pressure connectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2006
Resolved 13 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2006 Resolved
Remove all dead wiring in fuel compartment room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2006
Resolved 13 November 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 February 2006 Resolved
Provide 3-6 feet of line for the floating distress strobe light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 13 November 2007
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2004 Resolved
PROVIDE THE VESSELS STABILITY LETTER AND POST UNDER GLASS AT THE OPERATING STATTION IAW 46 CFR 176.306.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 3 February 2005
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 December 2004 Resolved
Provide a current compass deviation table IAW 46 CFR 185.304(8)
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 3 February 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 December 2004 Resolved
Service all expired portable fire extinguishers IAW NFPA 10 Chapter 4-1-2 and 4-4.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 3 February 2005
Lifesaving › Buoyant Apparatus
Issued 1 March 2004 Resolved
PROVIDE A BUOYANT FLOATING WATERLIGHT FOR LIFE FLOAT iaw 180.15-1(a) LEGACY COMPONENT DESC: floating light
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2004
Resolved 2 March 2004
Navigation › Piloting/Steering › Compass Deviation Table
Issued 1 March 2004 Resolved
PROVIDE A CURRENT COMPASS DEVIATION TABLE IAW 46 CFR 185.304 (8)
Action required: 705 - Other - as specified
Due 15 March 2004
Resolved 3 February 2005
Engineering › Fuel Oil Service System › Filter
Issued 1 March 2004 Resolved
INSTALL A FLAME BOWL AND MATALLIC DRAIN ON THE PORT GENERATOR FUEL OIL FILTER IAW 46 CFR 182.455 (6)
Action required: 705 - Other - as specified
Due 15 March 2004
Resolved 9 December 2004
Communications › Radio Communications
Issued 19 November 2002 Resolved
EPRIB BATTERY AND HYDROSTATIC RELEASE EXPIRED. VESSEL RESTRICTED TO WITHIN THREE MILES OF LAND. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 25 November 2002
Resolved 25 November 2003
Electrical › Lighting (service)
Issued 19 November 2002 Resolved
TWO SPOT LIGHTS NOT WORKING. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 19 December 2003
Engineering › Bilge Water Management System
Issued 19 November 2002 Resolved
TWO HIGH BILGE ALARMS NOT WORKING. LEGACY COMPONENT DESC: HIGH BILGE ALARMS
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2002
Resolved 20 November 2002
Documentation › Manifests/Lists
Issued 19 November 2002 Resolved
PASSENGER LIST NOT PROVIDED. LEGACY COMPONENT DESC: PASSENGER LIST
Action required: 705 - Other - as specified
Due 25 November 2002
Resolved 25 November 2003
Fire Fighting › Ventilation Systems
Issued 19 November 2002 Resolved
ALL VESSEL VENTS NOT PROVIDED WITH CLOUSURE DEVICES. LEGACY COMPONENT DESC: Ducts
Action required: 705 - Other - as specified
Due 25 November 2002
Resolved 25 November 2003
Engineering › Fuel Oil Service System
Issued 19 November 2002 Resolved
GENERATOR FUEL OIL FILTER NOT PROVIDED WITH FLAME BOWL AND MATALLIC DRAIN. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 19 December 2003
Lifesaving
Issued 22 October 2001 Resolved
Replace two waterlights.
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Construction/Loadline
Issued 22 October 2001 Resolved
Prove operation of bilge high level alarms, aft compartment, and engine room.
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Lifesaving
Issued 22 October 2001 Resolved
Provide first aid cards.
Condition: Unknown
Due 22 October 2001
Resolved 27 November 2003
Navigation
Issued 17 November 1994 Resolved
Prove proper operation of VHF radio.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Engineering
Issued 17 November 1994 Resolved
Reattach fuel shut off reach rod.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Engineering
Issued 17 November 1994 Resolved
Extend one vent in machinery space to a point just above the bottom.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Accommodation/Occupational Safety
Issued 17 November 1994 Resolved
Reattach MSD vent.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Documentation
Issued 5 January 1990 Resolved
PLACE ON BOARD VALID RADIO STATION LICENSE.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Documentation
Issued 5 January 1990 Resolved
PLACE ON BOARD VALID RADIO/TELEPHONEY SAFETY CERTIFICATE (FCC).
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990

Casualty record · 1

25 November 2008Routine · role: Involved in a Marine Casualty · activity 3369927
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.