MAURY USCG vessel records Sign in
← All vessels

SIGLOO TOR

SIGLOO TOR is a 1989 tank ship. The Coast Guard has recorded 36 inspections since 1989, most recently in April 2007, along with 13 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1989 to 2007. Most recent: inspection, 12 April 2007.

Built
1989
Last inspected
12 April 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8715895 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
340909
Flag
DENMARK
—
Maury page id
psix-340909

Inspections, by type

…with no type recorded20
Years with a record 15 calendar years (1989–2007)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11191 - Convention (Subpart B), Gross Ton
3357 - Convention (Subpart B), Net Ton
14489 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CORAL PALMATA Tank Ship · MISLE 409601 · 31 March 1997 · activity 70562MISS LAURA Towing Vessel · MISLE 100670 · 11 October 1993 · activity 26319

Inspection history · 36

12 April 2007 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2906635
10 April 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2905131
15 January 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1730943
15 January 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1730961
7 January 2003 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1727216
9 May 2002 Deficiency Check · Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1615211
16 April 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1605361
14 April 2002 Deficiency Check · Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1604836
12 April 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1616636
18 January 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286108
13 September 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281900
13 September 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 824771
27 July 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431023
25 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 525081
12 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416709
12 June 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 791547
28 May 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403946
31 March 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 70562
29 May 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391673
29 May 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1084177
1 April 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1420856
7 March 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167118
28 February 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 364873
29 November 1993 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 851558
11 October 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 26319
28 August 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 360386
28 August 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 830010
17 February 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1145281
2 July 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 539949
3 April 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 349834
11 December 1991 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 347696
11 December 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260518
10 July 1991 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 344658
1 December 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 903336
26 November 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911300
1 December 1989 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1229686

Deficiency record · 13

Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 12 April 2007 No resolution recorded
The vessel's secondary means of starting the emergency generator does not operate properly. The vessel is required to provide documentation from the certificate issuing authority attesting to the proper repair and operation of the secondary means of starting the emergency generator.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 January 2003 Resolved
Vessel suffered a loss of propulsion/power in reverse (33 CFR 160.111 - SOLAS 60/74 I/11). Provide attestation from the certificate issuing authority indicating that the vessel remains in class for Machinery.
Action required: 705 - Other - as specified
Due 15 January 2003
Resolved 16 January 2003
Resolution: Received report from Class attesting to repairs. Vessel cleared to sail.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 14 April 2002 Resolved
Temporary repairs to cargo liquid line on #3 system. IGC 5.3/5.4. Make permanent repairs to liquid line on the #3 system to the satisfaction of the certificate of fitness issuing authority. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 7 January 2003
Resolution: Received class report attesting to satisfactory repairs to cargo liquid line.
Unknown
Issued 13 September 2000 Resolved
Annex I cargoes are on approved list of cargoes / No "oil discharge monitoring equipment" (ODME) on board (33 CFR 157.12 & .29); Remove Annex I cargoes from approved list of cargoes or provide ODME on board. Completeprior to transferring Annex I cargoes in U.S.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Documentation
Issued 13 September 2000 Resolved
No Procedures and Arrangements manual on board. (IBC 16.A.3) Provide approved P&A manual on board prior to transferring chemical cargoes in U.S.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Deck/Cargo
Issued 28 May 1997 Resolved
Vessel's Vapor Control system flanges missing permanently attached stud_x001C_ IAW 46 CFR 39.20-1(e). Vessel is restricted from transferring cargoes requiring VCS in U.S. waters until corrected and inspected by local OCMI._x001C_
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Deck/Cargo
Issued 7 March 1994 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. IAW 33CFR155.750(d) MISSING VCS INFORMATION.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Deck/Cargo
Issued 7 March 1994 Resolved
PROVIDE INDEPENDENT AUDIO/VISUAL ALARMS FOR ONE DECK AREA "HIGH LEVEL AND OVERFILL" IAW 46CFR153.408(b)(1) PRESENT ALARM FUNCTIONS FOR BOTH REQUIREMENTS.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Deck/Cargo
Issued 7 March 1994 Resolved
AMEND CARGO TRANSFER PROCEDURES TO INCLUDE REQUIRED INFORMATION FOR VCS, IAW 33CFR155.750(d)
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Documentation
Issued 26 November 1990 Resolved
SUBMIT THE IMO GAS AND CHEMICAL FITNESS CERTIFICATES TO COMDT USCG FOR APPROVAL AND OBTAIN A VALID SUBCHAPTER "O" ENDORSEMENT PRIOR TO THE NEXT U.S. PORT CALL.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Fire Fighting
Issued 1 December 1989 Resolved
PROVIDE AN ADEQUATE SUPPLY OF SPAN GAS FOR TESTING GAS DETECTOR MONITOR IS ON BOARD.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Documentation
Issued 1 December 1989 Resolved
PROVIDE IOPP WITH PROPER NLS ENDORSEMENT.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Documentation
Issued 1 December 1989 Resolved
UPON RECEIPT OF NEW CERTIFICATE OF FITNESS SUBMIT THE SAME TO COMDT (G-MSC)FOR ISSUANCE OF A NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.