AMAZING GRACE

AMAZING GRACE is a 1990 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in May 2024, along with 67 deficiencies, 3 operational controls and 4 casualty investigations between 2012 and 2023.

Records from 2012 to 2024. Most recent: inspection, 29 May 2024.

Built
1990
Last inspected
29 May 2024
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 May 2024
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD7024
341224
Flag
UNITED STATES
Maury page id
psix-341224

Documentation record

Registered dimensions (L × B × D)58.0 ft × 15.0 ft × 8.0 ft
Registered tonnagegross 34 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDONALD KNOX MCQUISTON · SAN DIEGO, CA, UNITED STATES · built 1990
Hull materialConcrete
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN JUAN, PR
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 24 March 2025 · expires 31 March 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

29 May 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7922775
12 December 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7838192
15 May 2023 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7689313
15 April 2023 Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7669069
31 March 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7663180
12 October 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7576137
28 June 2022 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7485832
25 August 2021 Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7295422
28 June 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7238535
24 February 2021 Examination of Repairs · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7145590
14 January 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7124469
19 November 2020 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7098592
3 January 2020 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6882049
3 October 2019 Drydock Exam · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6827134
3 September 2019 COI Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6802294
22 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6758615
10 January 2019 Damage Survey · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6608456
31 October 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6575377
9 August 2018 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6505628
2 August 2017 Internal Structural Exam · Administrative Inspection · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6228733
6 July 2017 Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6200268
6 July 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6216109
17 May 2017 COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6142482
28 September 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6011264
9 August 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5966903
28 April 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5865390
28 April 2016 Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6109782
22 January 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5801809
11 January 2016 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5794910

Deficiency record · 67

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 April 2023 Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The starboard spreader mount was found damaged on the aft mast. A rigging survey detailing damage and likely cause is required as well as a repair proposal. This is to be reviewed and approved by the attending marine inspector prior to repair work being conducted. Copies of the last inspections of the rigging and last survey shall also be submitted for review to the USCG. 46CFR177.330
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The lifeline fitted to the ring life buoy was found to be degraded due to UV light and shall be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 26 October 2022
Resolution: Lifeline replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2022 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The vessel's name was no longer visible on ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 26 October 2022
Resolution: Name attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. No retroreflective material was present on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 26 October 2022
Resolution: Retro-reflective tape added.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 June 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. None of the stowage locations life-jackets were marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2022
Resolution: The lifejacket locations on board have been clearly labeled with 2 inch lettering.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 June 2022 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. The starboard side netting used as an equivalent to fixed rails did not have a means to secure the bottom aft corner to the bulwark.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2022
Resolution: A padeye was fixed to the bottom aft corner of the stbd bulwark to securely affix the stbd side netting.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 June 2022 Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84). Found that the plastic lens of the Port/STBD side light and stern light were UV damage reducing the intensity as required by the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 12 October 2022
Resolution: The port/stbd/stern nav lights were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The ring buoy becket grab lines were found to be degraded due to UV sun damage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 6 July 2022
Resolution: A new ring buoy has been placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: (1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and (6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. The one (01) required ring buoy was not fitted with a lifeline.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 6 July 2022
Resolution: A 60' lifeline has been attached to the new ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. In the crew cabin, port side, aft the 120 volt AC duplex outlet was missing its cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 28 July 2022
Resolution: Outlet cover replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Found two (02) 14 gallon plastic gas tanks stored in the forward v-berthing, remove fuel tanks from the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2022
Resolved 6 July 2022
Resolution: The two portable 14 gallon plastic diesel tanks have been removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 June 2022 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible where crew are normally employed. The escape route from the forward berthing was missing section of deck that made it difficult to access the overhead escape hatch. 46 CFR 177.15-1(a) Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2022
Resolution: The missing sections of deck used as steps to access the overhead escape hatch in the forward berthing has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Both the port and starboard valves did not indicated the closed position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 6 July 2022
Resolution: The closed position for the remote fuel shutoff stations have been indicated on both port and stbd valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. The following restrictions apply: (1) Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475 (incorporated by reference; see 46 CFR 175.600). Field attachable fittings must be installed following the manufacturer's recommended practice. If special equipment is required, such as crimping machines, it must be of the type and design specified by the manufacturer. If field attachable type fittings are used, each hose assembly must be individually hydrostatically tested to twice the maximum operating pressure of the system. Found no manufacture markings on non-metallic fuel hoses from fuel tank to the propulsion engine, could not verify hose met SAE J-1942 standards. All fuel hoses were double clamped at fittings from the fuel tank to the propulsion engine, not complying with SAE J-1475 hose end fitting standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 12 October 2022
Resolution: New fuel hoses and fittings meeting SAE J-1942 and SAE J-1475 were placed at the fuel shutoff connections and the fuel filters.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Provide adequate scaffolding (or suitable substitute) so that the attending marine inspectors can visually inspect the bowsprit area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Scaffolding provided and inspection conducted.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 August 2021 Resolved
Grind marked area at the port quarter in-way-of the vessel name and hailing port to remove bubbled paint and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Area ground and inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove vessel name bolted panel and make area behind it available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Name unbolted and area inspected. All good.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Grind bubbled hull paint at port and starboard bow (marked areas).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Areas ground and inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Permanently repair area at coaming (at port side) where there is a temporary repair which does not exhibit proper bonding between the exiting and new concrete.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
Resolution: repairs properly carried out.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove the following carriage bolts and nuts and make available for inspection (counting forward to aft): a. Main mast (port side): 1st lag screw b. Main mast (stbd side): 2nd lag screw c. Fore mast (port side): 3rd lag screw d. Fore mast (stbd side): 3rd lag screw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: wasted screws were removed and replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove rudder post base plate where post penetrates the hull, and related bolts and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Removed, checked and new have been installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Replace all three (03) headstays as its service life seems to have reached its end as indicated in the vessel preventative maintenance plan and rigging component’s inventory sheet.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: all three headstays were replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Grind and remove paint on starboard beam to further examine possible areas of water intrusion and wood rot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Successful examined areas.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Make areas around the port side beam in-way-of the main mast chain plates and make available for inspection. There seems to be wood rot in the surrounding areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2022
Resolution: These areas were properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Provide a full 3rd party rigging survey report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2022
Resolution: Third party sail rigging report dated June 11, 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove all paint and corrosion on all exterior chain plates and make available for further inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: All chainplates have been cleaned for detailed inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove all rotted and/or damaged wood at top (cap) of coaming, both port side and starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: All wood have been removed and replaced as in kind.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Clean metallic “Y” assembly connecting the vessel’s running gear below the dolphin striker and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Successfully verified condition.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove damaged/rotted wooden channels supporting the chain plates and make available for inspection. Identify damaged/rotted areas and discuss the proposed repairs with the attending marine inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Removed and repaired as in kind. All securing bolts in all other channels have been replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Clean areas where the inner headstay brackets meet the hull. There are signs of wastage. Make available for further inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Cleaned and verified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Grind/remove all visible corrosion on chain plates and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2021
Resolved 28 April 2022
Resolution: All chainplates have been cleaned and visually inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Remove and clean angle bar supporting H-block (at anchor locker space).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Cleaned and re-installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
At the bow and below the anchor locker, remove concrete repairs (showing signs of fractures) and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: All cleaned, removed and repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Clean and expose concrete areas where angle bar penetrates the concrete hull. There are signs of concrete damage. Make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: All areas cleaned, repaired and inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
At forward space, port side storage area behind 2nd drawer, grind marked area and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: Area was repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
Make proper repairs to ensure that 2nd scuttle overhead hatch cover is weathertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Scuttle has been repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021 Resolved
At main cabin, remove all inner port side chain plates and make available for inspection. This is to include the chainplates behind the refrigerator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Chainplates have been removed, the chainplate behind the refrigerator was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 February 2021 Resolved
Provide the most recent Sail and Rigging 3rd party survey. 46 CFR176.840
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2021
Resolved 12 April 2021
Resolution: Received the 3rd party rigging survey.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 February 2021 Resolved
A hatch on a vessel that operates only on a partially protected waters must be weathertight. The forward hatch cover was found to have rotten areas near the hinges, where it connects with the trunk and is not making a proper weather tight seal, and is not secured by the hinges. Conduct repairs to both the trunk and hatch and make it weather tight.
Action required: 705 - Other - as specified
Due 18 June 2021
Resolved 28 April 2022
Resolution: Hatch was replaced with new wooden access hatch and found to be weathertight upon testing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2021 Resolved
The H block located forward of the watertight hatch cover was found to have both structural support members with missing wood, caused by chafing and friction above deck. Conduct permanent repairs as original design prior granting credit on next dry dock.
Action required: 705 - Other - as specified
Resolved 28 April 2022
Resolution: H block was repaired and reinstalled in place.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 January 2021 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down engines. Current pre-engineered fire extinguishing system failed to prevent the engines from shutting off; once activated, engines couldn't be shut-off. Demonstrate proper operation of emergency override switch to the satisfaction of an attending USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2021
Resolution: Conducted a successful test of the emergency override system after a contracted technician replaced the electronic module that operates the override system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 January 2021 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must be installed in accordance with the manufacturer's instructions. The cable that operates the hook that breaks the ampule is being obstructed by the metal safety guard covering the ampule.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2021
Resolution: The protective guard was returned to its original position, releasing the ampule hook and cable to operate freely.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 January 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The existing visual alarm panel was removed after the installation of the new engine. Install a visual high water alarm at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 27 January 2021
Resolution: A redundant visual high water alarm was installed at the operating station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 January 2021 Resolved
On a vessel of at least 26 feet, a visual and audible alarm must be provided at the operating station to indicate a high water level in the machinery space bilge. A submersible bilge pump # 1 float switch that activates both the pump and the alarm where found inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 27 January 2021
Resolution: The float switch wire was cleaned and re-attached, and was found to be operating properly.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 January 2021 Resolved
VHF-DSC Radio must be properly connected to a GPS receiver or have a VHF-DSC marine radio with integral GPS, and have entered a valid MMSI number. Current installed VHF radio was not displaying GPS coordinates and not having displayed the MMSI number.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 27 January 2021
Resolution: VHF radio was found to be connected to the GPS and MMSI Number was also found to be entered in the radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2021 Resolved
The design, materials and construction of mast, post, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Vessel owner must submit to the OCMI thefollowing documents and plan: 1. Sail and Rigging Preventive Maintenance Plan (PMP) that is amended and updated with the current changes in the rigging and recommended inspection regime. 2. Provide the most recent Sail and Rigging 3rd party survey.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 24 February 2021
Resolution: Preventive Maintenance plan was submitted and found satisfactory. A new separate deficiency will be issued to request the 3rd party rigging survey.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 January 2021 Resolved
Abandon Ship, man overboard, fire drills and training shall be logged or otherwise documented for review by the U.S. Coast Guard upon request. Provide a suitable drills and training log to be on board to document all drills and training conducted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 27 January 2021
Resolution: Drills and training logs were found to be located on board, in a watertight container.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 January 2021 Resolved
As appropriate for the intended voyage the vessel must carry adequate and up to date charts, tide and current tables. Provide current and updated nautical charts, tide tables and current tables to be on board the vessel for the master reference.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 27 January 2021
Resolution: Missing publications were found to be on board and a updated chart was placed on board.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 January 2020 Resolved
A vessel must be fixed with a gas fire extinguishing system capable of shutting down the engine. The extinguishing system does not shutdown the engine. IAW 46 CFR 181.400
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2020
Resolution: Extinguishing system shuts down engine.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 January 2020 Resolved
A vessel must have at least three 2.5 gallon buckets with lanyards and words "FIRE BUCKET" stenciled in a contrasting color. Only one fire bucket was found, without a lanyard and labeling. IAW 46 CFR 181.600
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2020
Resolution: Vessel had three (03) fire buckets labeled with lanyards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020 Resolved
The vessel must provide plans for re-powering of the vessel's engine to the [name withheld] have not been submitted. IAW 46 CFR 176.600
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 January 2020
Resolved 16 January 2020
Resolution: Received plans
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 January 2020 Resolved
A vessel must have sidelights with an arc of the horizon of 112.5 degrees as fixed to show light from right ahead to 22.5 degrees abaft the beam. The sidelights do not have the proper arc of visibility. IAW 33 CFR 83.21(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 16 January 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 January 2020 Resolved
A documented vessel's name must be visible on the exterior of the port and starboard side. The markings are not on the vessel. IAW 46 CFR 67.123
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 13 January 2020
Resolution: Vessel's name is on the exterior of the port and starbord side of the boat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 January 2020 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. The vessel is missing two adult lifejackets. IAW 46 CFR 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 13 January 2020
Resolution: Vessel has the required number of adult lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 January 2020 Resolved
Placards containing instructions for donning and use of lifejackets must be posted in a space accessible to passengers and crew. The vessel does not have a placard posted onboard. IAW 46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 13 January 2020
Resolution: Placard is posted in area accessible to passengers and crew members.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 January 2020 Resolved
Each ring life buoy must be marked with Type II retro reflective material IAW IMO Resolution A.658(16). The ring life buoy does not have retro reflective material. IAW 46 CFR 185.064(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 13 January 2020
Resolution: Ring buoy is marked with Type II retro reflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 3 January 2020 Resolved
A vessel must have a platform if the vessel cannot adequatley recover a person. On the port side, the attachment point must be moved aft to center the opening. The starboard side must have a similar arrangement. IAW 46 CFR 185.524
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 13 January 2020
Resolution: Vessel has adequate platform for the recovery of a person.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 January 2020 Resolved
A vessel must ensure the required crew members are covered by a consortium, if it chooses to satisfy random testing in this manner. The vessel's 2020 consortium list was not available. IAW 46 CFR 16.230(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 16 January 2020
Resolution: Vessel's 2020 consortium is onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 January 2020 Resolved
Each vessel must be equipped with at least two operable portable battery lights at the operating station and access to propulsion machinery space. The vessel does not have two portable lights. IAW 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2020
Resolved 13 January 2020
Resolution: Vessel now has two (02) portable lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2019 Resolved
At each initial and subsequent inspection for certification of a vessel,the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. During COI exam inspector found several severely corroded turnbuckles, pins, terminals and toggles. Head-stay pin at Cranse Iron was pulling out. Turnbuckle on jib boom and starboard whisker on bowsprit are two-blocked. Port side aft shroud chain plate block was crushed and bolt holding shroud was pulled partially out of block. Starboard intermediate aft shroud dead-eye lanyard is worn. Possible crack on starboard chain plate for starboard bobstay. Several wooden blocks show signs of cracking and/or completely broken. Port side port light fasteners severely corroded. Inspection was stopped and a third party rigging survey will be required. During 3rd party survey a CG marine inspector shall be present. 46 CFR 176.802 (a) (3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2019
Resolved 3 January 2020
Resolution: Vessel passed certification of inspection. See Activity #6882049.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 August 2018 Resolved
05109- A United States vessel which transports more than six passenger vessels for hire while such vessel is being navigated on any tidewater within the jurisdictions of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation properly connected to a GPS receiver or have a VHF-DSC marine radio with integral GPS. VHF radio was found not being connected to a GPS nor displaying any coordinates upon testing. 47 CFR 80.901; 80.905; 80.1101(c)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2018
Resolved 10 September 2018
Resolution: VHF radio was connected to a GPS receiver.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 August 2018 Resolved
13103-Gauges to indicate engine revolutions per minute (RPM) must be provided for all propulsion engines installed in the vessel. Prove proper operation of the RPM gauge located in the operating station, which was found to be inoperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2018
Resolved 4 September 2018
Resolution: A new RPM gauge was installed and was found operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 10 August 2018 Resolved
04106-A vessel must be provided with an auxiliary means of steering as required in 46 CFR 182.620(a)(1). Vessel is not equipped with an auxiliary steering system.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2018
Resolved 9 November 2018
Resolution: Vessel issued a special consideration for not having auxiliary means of steering. Uploading document into vessel's certificates.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 6 July 2017 Resolved
Degraded Exhaust Manifold gasket not allowing compression buildup.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Resolution: Replaced the faulty gasket.
Engineering › Steering Gear System › Linkage
Issued 17 May 2017 Resolved
Provide a means of auxiliary steering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2017
Resolved 10 August 2018
Resolution: Deficiency was re-issued on a new CG835V form.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2017 Resolved
Provide a means of resetting the propulsion engine at the operating station.
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 10 August 2018
Resolution: Fireboy brand override control switch was installed next to the operating station in the top deck, next to the wheel.
Construction/Loadline › Hull › Hull Plating
Issued 28 April 2016 Resolved
Provide a dive report to assess the condition of the hull following an accidental grounding.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2016
Resolution: A video was presented at SSJ inspections division showing the entire hull on which it was no damage evident to the vessel hull.

Casualty record · 4

8 September 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 4441145
28 April 2016Routine · role: Involved in a Marine Casualty · activity 5865390
6 July 2017Routine · role: Involved in a Marine Casualty · activity 6216109
31 March 2023Routine · role: Involved in a Marine Casualty · activity 7663180
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.