Records from 2001 to 2024. Most recent: inspection, 30 January 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
30 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7857998
11 May 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2064819
6 January 2004
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1990506
16 December 2003
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1964825
3 November 2003
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1940987
13 August 2003
Construction Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1925748
15 November 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1705581
9 September 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1672769
12 October 2001
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453948
31 August 2001
Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1422118
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 January 2004
Resolved
Provide copy of fire service report for fixed and portable fire fighting equipment.
Due 6 January 2004
Resolved 6 January 2004
Communications › Radio Communications
Issued 6 January 2004
Resolved
Provide copy of valid FCC Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2004.
Stability › Incline Test
Issued 13 August 2003
Resolved
CONDUCT A STABILITY TEST IN ACCORDANCE WITH G-MSC LTR 16710/P006756, SER: H2-0306651 DATED OCTOBER 09, 2003, AND RECEIPT OF AN UP-TO-DATE STABILITY LETTER.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2004
Resolved 6 January 2004
Resolution: Owner had submitted Incline procedures to incrrease passenger count, vessel not in operation and owner decided not to increase passenger due to cost of test, and vessel is up for sale.
Lifesaving › Embarkation Appliances/Stations
Issued 13 August 2003
Resolved
RELOCATE THE HUTCH IN WAY OF FR. 35, MAIN DECK, STBD SIDE, TO THE APPROVED EMERGENCY EVACUATION PLAN AND THE APPROVED STRUCTURAL FIRE PROTECTION PLAN, AS SHOWN ON THE DRAWINGS, OR, RESUBMIT DRAWINGS FOR APPROVAL. LEGACY COMPONENT DESC: Accessability
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2004
Operations/Management › Drills/Instruction
Issued 15 November 2002
Resolved
Perform a fire and man overboard drill in the presence of CG Marine Inspector(s). LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2002
Resolved 6 January 2004
Electrical › Electric Generation Source (service)
Issued 15 November 2002
Resolved
Install generator rating placard on each generator. LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2002
Resolved 6 January 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 15 November 2002
Resolved
Provide adequate guards for the fuel tank sight glasses. LEGACY COMPONENT DESC: Gauge
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2002
Resolved 6 January 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 November 2002
Resolved
Provide evidence of an ongoing drug testing program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2004.
Fire Fighting › Structural Fire Protection - General
Issued 15 November 2002
Resolved
Remove a doorstop from FSD located on the third deck. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2002
Resolved 6 January 2004