MAURY USCG vessel records Sign in
← All vessels

HOUSTON TIDES AND VIBES

HOUSTON TIDES AND VIBES is a 1989 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1989, most recently in June 2026, along with 57 deficiencies.

Records from 1989 to 2026. Most recent: inspection, 9 June 2026.

Built
1989
Last inspected
9 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

342117
Flag
UNITED STATES
—
Maury page id
psix-342117

Inspections, by type

…with no type recorded5
Years with a record 30 calendar years (1989–2026)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 51

9 June 2026 COI Inspection · Administrative Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8406027
7 April 2026 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8332244
29 September 2025 Examination of Repairs · Drydock Exam · Hull Examination · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8243803
11 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8188771
28 March 2025 Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8102611
24 June 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7938574
14 December 2023 Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7839235
25 September 2023 Deadweight Survey · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7796614
14 September 2023 Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7790065
21 October 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7581711
21 December 2021 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7356950
20 May 2021 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7201594
25 November 2019 Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6808549
14 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6856319
7 February 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6618795
12 February 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6355135
30 October 2017 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6297718
17 February 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6094015
13 October 2016 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045173
2 November 2015 Annual Inspection · Hull Examination · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5756507
27 October 2015 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5751935
13 December 2011 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4212782
1 December 2011 Deadweight Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4486800
1 September 2011 Administrative Inspection · In-Service Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4189223
22 February 2010 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3684573
16 January 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3397260
14 March 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3166257
19 January 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2858550
10 January 2007 Simplified Stability Test · COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2852329
5 January 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2852127
8 April 2005 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2329129
31 October 2003 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1937881
7 March 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1752054
15 January 2002 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1478213
26 November 1999 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378956
11 December 1998 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1372519
17 December 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441329
13 December 1996 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1360686
18 September 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 825582
11 December 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1184901
15 November 1994 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 867794
8 December 1993 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1162900
14 April 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1153575
11 December 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 828396
2 March 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1256784
2 March 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257494
10 February 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257346
19 November 1991 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1248746
18 January 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1211856
5 January 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 908824
13 December 1989 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1242645

Deficiency record · 57

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel was underway when a material failure occurred causing one (of two) outboard engines to break free from the vessel. Make repairs to satisfaction of attending marine inspector prior to commercial service. 46 CFR 176.700(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2025
Resolution: Repairs were completed to satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 September 2023 Resolved
Independent fuel tanks must be designed and constructed IAW 46CFR182.440.(2) plastic fuel tanks are permanently mounted to the aft deck, and are not suitable for the vessel's intended service. MFR: Moeller Marine Products, Model: FTA000473, Capacity: 22 gallons each. 46CFR182.440
Action required: 60 - Rectify deficiencies prior to movement
Due 25 September 2023
Resolved 18 December 2023
Resolution: Independent fuel tanks are now designed and constructed IAW 46CFR182.440.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Fuel oil service system shutoff valves are seized in the open position, non-operable, and located directly on the deck, not properly secured or mounted. 46CFR182.455(b)(4)
Action required: 60 - Rectify deficiencies prior to movement
Due 25 September 2023
Resolved 18 December 2023
Resolution: New Fuel oil service system shutoff valves are now operational and properly secured or mounted.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 25 September 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The following general arrangement modifications were made without OCMI approval following the issuance of stability letter Serial# H1-1700251. The capacity of the fuel tanks increased from (1) 30 gal tank to (2) 22 gal tanks, location of the fuel tanks changed, the fuel tank storage box was removed, and helm console was replaced. Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. As a result, the vessel's stability has been questioned by the cognizant Officer in Charge, Marine Inspection (OCMI). A new stability test must be conducted IAW 46CFR178.310. 46CFR176.700
Action required: 60 - Rectify deficiencies prior to movement
Due 25 September 2023
Resolved 5 April 2024
Resolution: Stability ltr was issued and permanent ballast was installed IAW approved plans.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2023
Resolved 5 April 2024
Resolution: Vsl received FCC docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2023 Resolved
Vessel must have a FCC Safety Radiotelephony Certificate. Vessel does not have a valid FCC Safety Radiotelephony Certificate. Obtain an FCC Safety Radiotelephony Certificate prior to operating the vessel. 47CFR80.59
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2023
Resolved 5 April 2024
Resolution: Vsl received FCC docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 October 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was required to complete an annual inspection by 07 September 2022 and has yet to complete an annual inspection. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2022
Resolved 1 November 2022
Resolution: Conducted satisfactory Annual Inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 May 2021 Resolved
Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel did not complete annual inspection within prescribed window. Complete annual prior to carriage of passengers. 46 CFR 176.500 (b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2021
Resolution: COI issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First Aid had outdated items and was in bad condition. Replace expired contents. 46 CFR 184.710
Action required: 10 - Deficiency Rectified
Resolved 28 June 2021
Resolution: Owner provided new approved first aid kit
Stability › Incline Test › General
Issued 12 February 2018 Resolved
Provide all necessary documentation for engine repower to MSC for a determination as if it has been more than a 2% weight change.
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 4 April 2019
Resolution: Received MSC Determination letter.
Construction/Loadline › Hull › Hull Plating
Issued 27 November 2017 Resolved
After 30NOV17 vsl has been issued a NO-SAIL until dry dock examination is complete. 46CFR176.600.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 5 December 2017
Resolution: Conducted satisfactory DDX.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 October 2016 Resolved
17 PFD's taken out of service due to cracks in the orange coating covering foam floatation material. Owner pland to get jim bouy repair kit. Passenger count reduced to 13. 46CFR180.7
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 18 January 2017
Resolution: Owner replaced all Life Jackets.
Lifesaving › Hand Flares › Expired
Issued 13 October 2016 Resolved
2 hand held flares were expired. 46CFR180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2016
Resolution: Owner replaced flares.
Construction/Loadline › Structures › Superstructure
Issued 2 November 2015 Resolved
Canopy support pole cracked at weld. Repair to the satisfaction of Marine Inspector. 46CFR176.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2015
Resolution: Cracked weld repaired.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 November 2015 Resolved
Missing two portable lights. 46CFR184.30-1
Due 9 November 2015
Resolved 25 November 2015
Resolution: Portable lights supplied.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 November 2015 Resolved
Repair cracked life-jackets. Passenger count reduced to 12. 46CFR180.71
Action required: 705 - Other - as specified
Resolved 25 November 2015
Resolution: Repaired/replaced cracked life jacketsIAW 46CFR180.71. Passenger count reduced to 12.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2012 Resolved
Per the General Arrangement drawing dated 21 Nov 2011, provide sign stating, "CREW ONLY" for the temporary chains across the port & stbd bow safety railings.
Action required: 705 - Other - as specified
Due 31 December 2012
Resolved 11 February 2013
Resolution: Visited vsl and observed the crew only signs installed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 7 December 2012 Resolved
Relocate the dive ladder to the port or stbd aft side opening as a result of the stability ltr dtd Oct 23, 2012 and General Arrangement Dwg dtd 21 November 2011.
Action required: 705 - Other - as specified
Due 4 January 2013
Resolved 11 February 2013
Resolution: Visited vsl and dive ladder relocated as required by naval architect drawing.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2012 Resolved
Install 39" high permanent safety railings with access gate openings of at least 28" (may be larger) across forward end of existing safety railings as a result of stability ltr dtd Oct 23, 2012 & General Arrangement Dwg dtd 21 Nov 2011. Railings must have courses not more than 12" apart with additional separations not more than 4" openings or canvas or other solid material or netting installed.
Action required: 705 - Other - as specified
Resolved 3 February 2014
Resolution: Owner installed permanent safety railing with access gates.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 22 February 2010 Resolved
Reroute fuel line outside of electrical wiring box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 22 February 2010
Resolution: Vessel owner rerouted fuel line to satisfactory location outside of wiring box.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2010 Resolved
Provide new battery for lifering waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 22 February 2010
Resolution: Owner purchased and installed new battery for waterlight.
Construction/Loadline › Structures › Deck Plating
Issued 10 January 2007 Resolved
Repair hole in deck located at the aft port side of the vessel.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 22 January 2007
Resolution: Hole located at the aft port side of the vessel was repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 10 January 2007 Resolved
Replace most forward transverse deck frame located underneath FRP overlay on the port side.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 22 January 2007
Resolution: Most forward transverse deck frame located underneath FRP overlay on the port side was properly replaced.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 January 2007 Resolved
Renew centerline deck frame located at the vessel's bow.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 22 January 2007
Resolution: Centerline deck frame located at the vessel''s bow was renewed to original.
Construction/Loadline › Structures › Deck Plating
Issued 10 January 2007 Resolved
Replace 6 inch x 4 inch FRP overlay on top of wooden deck located at the vessel's bow.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 22 January 2007
Resolution: 6 inch x 4 inch FRP overlay on top of wooden deck located at the vessel''s bow was repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 January 2007 Resolved
Replace battery wing nuts with locking nuts or add locking washers.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 22 January 2007
Resolution: Battery wing nuts were reinforced with locking nuts.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 January 2007 Resolved
Properly label lifejacket storage with child/adult signage and provide separation between life jackets.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 3 February 2007
Resolution: Lifejacket storage were properly labeled with child/adult signage and provided with separation between life jackets.
Engineering › Fuel Oil Service System › Hose
Issued 10 January 2007 Resolved
Double clamp all fuel lines.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 22 January 2007
Resolution: All fuel ines were double clamped.
Documentation › Certificates/Documents › Stability Letter
Issued 10 January 2007 Resolved
Conduct a satisfactory pontoon simplified stability test.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 14 February 2007
Resolution: Vessel underwent a satisfactory wall-sided simplified pontoon stability test.
Engineering › Gasoline Engine (propulsion)
Issued 31 October 2003 Resolved
Prior to the carriage of passengers, provide a third party report attesting to the proper operation of the PORT outboard engine. LEGACY COMPONENT DESC: PORT outboard
Condition: Improper/Lack of Maintenance
Due 31 October 2003
Resolved 5 November 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 March 2003 Resolved
Replace retroreflective material on all PFD's that require it. LEGACY COMPONENT DESC: Retroreflective Material
Due 17 March 2003
Resolved 31 October 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 March 2003 Resolved
Provide annual service for the portable fire extinguishers. LEGACY COMPONENT DESC: Service
Due 17 March 2003
Resolved 31 October 2003
Engineering › Bilge Water Management System
Issued 7 March 2003 Resolved
Repair bilge pump, prior to carrying passengers. LEGACY COMPONENT DESC: Pump
Due 17 March 2003
Resolved 31 October 2003
Operations/Management › Drills/Instruction
Issued 7 March 2003 Resolved
Conduct underway drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 17 March 2003
Resolved 31 October 2003
Stability › Watertight Integrity
Issued 7 March 2003 Resolved
Prior to the carriage of passengers, conduct early drydock of vessel to determine condition of the inside. Vessel has had a history of water sitting inside the hulls.
Due 17 March 2003
Resolved 31 October 2003
Construction/Loadline › Hull
Issued 7 March 2003 Resolved
Cut inspection access plates to make it possible to inspect the inside.
Due 17 March 2003
Resolved 3 November 2003
Navigation
Issued 26 November 1999 Resolved
MODIFY NAVIGATION LIGHTS TO COMPLY WITH COLREGS.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 26 November 1999 Resolved
PROVIDE AN ADDITIONAL FIRE EXTINGUISHER, SIZE B-I.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Lifesaving
Issued 26 November 1999 Resolved
PROVIDE EITHER 6 RED HAND AND 6 ORANGE SMOKE FLARES OR AN ORANGE CG APPROVED DISTRESS FLAG.
Condition: Unknown
Due 26 December 1999
Resolved 10 April 2000
Lifesaving
Issued 17 December 1997 Resolved
RE-STENCIL CHILDRENS PFD'S WITH CORRECT VESSEL INFORMATION.
Condition: Unknown
Due 17 December 1997
Resolved 22 December 1997
Lifesaving
Issued 17 December 1997 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON ALL LIFEJACKETS.
Condition: Unknown
Due 17 December 1997
Resolved 22 December 1997
Fire Fighting
Issued 17 December 1997 Resolved
REPLACE OUTDATED FIRE EXTINGUISHER.
Condition: Unknown
Due 17 December 1997
Resolved 22 December 1997
Engineering
Issued 13 December 1996 Resolved
REPAIR OIL LEAK ON STARBOARD ENGINE LUBE OIL LINE.
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Documentation
Issued 11 December 1995 Resolved
PROVIDE DRUG TESTING RECORDS.
Condition: Unknown
Due 11 December 1995
Resolved 11 December 1995
Accommodation/Occupational Safety
Issued 11 December 1995 Resolved
PROVIDE 36 INCH RAILS AROUND FORWARD PASSENGER AREA.
Condition: Unknown
Due 11 December 1995
Resolved 11 December 1995
Lifesaving
Issued 11 December 1995 Resolved
PROVIDE 6 ORANGE FLARES.
Condition: Unknown
Due 11 December 1995
Resolved 11 December 1995
Lifesaving
Issued 8 December 1993 Resolved
PROVIDE 3 ADDITIONAL HAND HELD ORANGE SMOKE FLARES.
Condition: Unknown
Due 15 December 1993
Resolved 15 December 1993
Fire Fighting
Issued 8 December 1993 Resolved
PROVIDE AND INSTALL 1 B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 15 December 1993
Resolved 15 December 1993
Lifesaving
Issued 19 November 1991 Resolved
PROVIDE 3 ADULT PFD'S; PASSENGERS ALLOWED IS REDUCED TO 24 UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 19 November 1991
Resolved 19 November 1991
Fire Fighting
Issued 19 November 1991 Resolved
PROVIDE LABELING TO SHOW LOCATION OF FIRE EXTINGUISHER.
Condition: Unknown
Due 19 November 1991
Resolved 19 November 1991
Navigation
Issued 19 November 1991 Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 6 December 1991
Resolved 6 December 1991
Documentation
Issued 18 January 1991 Resolved
POST A GARBAGE STICKER.
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991
Lifesaving
Issued 18 January 1991 Resolved
REMOVE TAPE AND PROPERLY INSTALL RINGBUOY LIGHT.
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991
Documentation
Issued 18 January 1991 Resolved
PROVIDE AN FCC STATION LICENSE.
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991
Lifesaving
Issued 18 January 1991 Resolved
PROVIDE 6 ORANGE FLARES.
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991
Navigation
Issued 18 January 1991 Resolved
REPAIR ANCHOR LIGHTS. (NONE)
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991
Lifesaving
Issued 13 December 1989 Resolved
PROVIDE 4 ADDITIONAL DAY/NIGHT SIGNALING DEVICES.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989

Ownership record