Records from 2001 to 2026. Most recent: inspection, 1 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
1 May 2026
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8361500
24 June 2025
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8166516
19 April 2024
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7899433
19 April 2023
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7671888
22 June 2022
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7484001
4 May 2021
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7189404
1 July 2020
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6993203
8 July 2019
Administrative Inspection · COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6743562
18 April 2018
Administrative Inspection · COC-CVE Annual · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6394263
17 April 2017
COC-CVE Annual · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6126480
13 July 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5945130
12 April 2016
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5921394
21 April 2009
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3637007
2 May 2008
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3199159
9 May 2007
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2959528
28 April 2006
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2626454
26 July 2005
COC-CVE Annual · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2426314
20 July 2004
COC-CVE Annual
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2139010
29 July 2003
Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1860240
8 August 2002
Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1658284
13 August 2001
Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1069013
Construction/Loadline › Hull › Weld
Issued 9 May 2007
Resolved
V/W cracked stiffener in engine room # 1 transverse stiffener IWO #2 engine.
Action required: 705 - Other - as specified
Due 9 May 2007
Resolved 9 May 2007
Resolution: Crack v/w prior to our departure.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2005
Resolved
Properly mount high water alarm in engine space and secure wires appropriately.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation from operation manager attesting to the satisfactory completion of issued requirement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2005
Resolved
Within engine space electrical wires/cables, fuel hoses and hydraulic hoses requiring chaffing protection and supports to prevent damage as they pass through or over framing. Replace components where outer protective coating has been damaged, install supports and chaffing as necessary.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation from operation manager attesting to the satisfactory completion of issue requirement.
Construction/Loadline › Penetrations › Weld
Issued 26 July 2005
Resolved
Repair intake pipe for port engine water intake, weld failure identified at the 7 O’clock position, grind and weld to the satisfaction of the attending Transport Canada surveyor.
Action required: 705 - Other - as specified
Due 26 July 2005
Resolved 26 July 2005
Resolution: Prior to our departure witnessed satisfactory repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2005
Resolved
Sensor for hydraulic block on Hamilton drive removed on two of three drives. Ensure manufacture approves of this modification, with report to Transport Canada and follow-up approval to the reported installation of gasket and inoperative switch.
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.