MAURY USCG vessel records Sign in
← All vessels

GREEN NEPTUNIC

GREEN NEPTUNIC is a 1989 freight ship. The Coast Guard has recorded 17 inspections since 1989, most recently in September 2010, along with 12 deficiencies and 3 operational controls.

Records from 1989 to 2010. Most recent: inspection, 16 September 2010.

Built
1989
Last inspected
16 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8805614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
342152
Flag
BAHAMAS, THE
—
Maury page id
psix-342152

Inspections, by type

…with no type recorded13
Years with a record 12 calendar years (1989–2010)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3998 - Convention (Subpart B), Gross Ton
2744 - Convention (Subpart B), Net Ton
5165 - Dead Weight, Ton
7585 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

16 September 2010 PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3846233
24 July 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3275979
24 July 2008 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3276577
25 October 2007 PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3081743
6 October 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2794959
29 August 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 281510
24 July 1997 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 406148
17 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 395456
13 June 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 670961
13 June 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 670962
11 June 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 392095
19 September 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 441631
16 January 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 374284
10 May 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 350724
24 June 1991 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 344547
20 March 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 335944
18 December 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 334322

Deficiency record · 12

Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 24 July 2008 Resolved
Vessel could not start the EDG. Attest to the proper operation of the battery charging system and the EDG starting system. See Narrative for explanation of def. to the satisfaction of the administration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2008
Resolution: Tested and approved by the Flag surveyor. See attached report
Electrical › Electric Generation Source (service) › Generator
Issued 24 July 2008 Resolved
Vessels SSDG is non-operational. See narrative for full explanation on def. Repair and attest to the proper operation of the 02 SSDG. To the satisfaction of the Administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2008
Resolution: Technician repaired generator while Flag surveyor was on board. See attached report. Tech sent additional report on the repairs made to the electrical components that were replaced.
Communications › Radio Communications › Emergency Source of Power
Issued 24 July 2008 Resolved
The Battery Box for the GMDSS has a large dead ended cable sitting loose inside the box. This cable should be correctly installed or removed to prevent a fire/explosion hazard inside the battery box.
Action required: 705 - Other - as specified
Due 24 August 2008
Resolved 16 September 2010
Resolution: Wire was cut back and taped off. Cheif Engineer proved using power meter to USCG that wire was dead.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 6 October 2006 Resolved
Ballast Water Management Plan to be reviewed and approved by class. (request by master)
Action required: 705 - Other - as specified
Due 5 November 2006
Resolved 25 October 2007
Resolution: BWM Plan is now approved by Class.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 6 October 2006 Resolved
Steering gear flats do not have a mount for compass repeater, provide in accordance with SOLAS Ch. V Reg. 19.2.5.2
Action required: 705 - Other - as specified
Due 5 November 2006
Resolved 25 October 2007
Resolution: Inspection team cleared deficiency.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 6 October 2006 Resolved
MSD (type II) to be inspected and approved by class, attesting to build type. 33 CFR 159.15
Action required: 705 - Other - as specified
Due 5 November 2006
Resolved 25 October 2007
Resolution: This deficiency is not applicable to this vessel at this time.
Lifesaving
Issued 24 July 1997 Resolved
INSTALL GRATINGS OR NON-SLIP SURFACE IN AFT STEERING COMPARTMENT
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Navigation
Issued 24 July 1997 Resolved
VESSEL'S ECHO DEPTH SOUNDER RECORDER WAS NOT OPERATING CORRCTLY.
Condition: Unknown
Due 25 July 1997
Resolved 28 July 1997
Documentation
Issued 11 June 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Deck/Cargo
Issued 11 June 1996 Resolved
REPAIR WASTED HOLE IN STARBOARD MAIN DECK FILL CONTAINMENT.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Navigation
Issued 20 March 1990 Resolved
A VIO OF 33CFR164.11(R) IN THAT THE GYRO COMPASS REQ. BY 33CFR164.35(D) WASNOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/W IN THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Navigation
Issued 18 December 1989 Resolved
A VIO OF 33CFR164.30 IN THAT THE U.S. CHARTS 12214,12304,12304,12311,12312 AND 12313 WERE NOT O/B FOR THE VSL'S ROUTE FROM CAPE HENLOPEN DE TO PHILADELPHIA PA. NO FOREIGN EQUIVALENT CHARTS O/B.
Condition: Unknown
Due 18 December 1989
Resolved 18 December 1989

Ownership record