MAURY USCG vessel records
← All vessels

ST NICHOLAS VII

Built
1989
Last inspected
24 November 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

342156
Flag
UNITED STATES
Maury page id
psix-342156

Documentation record

Registered dimensions (L × B × D)45.6 ft × 15.5 ft × 5.0 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAROUKOS BOAT BLDG CORP · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTARPON SPRINGS, FL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 3 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

24 November 2025 Administrative Inspection · Vessel Attendance · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8273444
17 September 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8236200
11 December 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8038795
18 December 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7833712
11 October 2023 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7799469
8 May 2023 Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7684316
13 December 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7599004
7 December 2021 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7363719
8 October 2021 Hull Examination · Deficiency Check · Internal Structural Exam · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7300583
15 December 2020 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7102114
22 November 2019 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6860879
17 October 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6826673
4 December 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6591658
15 December 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6324244
24 August 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6250266
6 December 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6054833
28 November 2016 Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6048760

Deficiency record · 24

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 December 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed STBD side navigational light nonoperational. Repair STBD side navigational light to meet International and Inland Navigation Rules standard and to the satisfaction of the attending MI. Vessel restricted to daytime operations. Repair within two weeks. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 23 December 2025
Resolved 19 December 2025
Resolution: Recieved photos of operational PORT, STBD, and masthead light.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 December 2025 Resolved
A vessel of not more than 65 feet in length is not required to carry a rescue boat unless: (1) The vessel carries passengers on an open or partially enclosed deck; and (2) The cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. MI observed crewmember using MOB recovery ladder without sufficient means to secure oneself to the vessel during MOB recovery operations. Configure MOB recovery crewmember's lifejacket with adequate means to secure oneself to the vessel. Provide satisfactory proof of implementation to the attending [name withheld] within two weeks. 46 CFR 180.210 (b) (1) & (2)
Action required: 705 - Other - as specified
Due 23 December 2025
Resolved 10 December 2025
Resolution: New lifejacket acquired with safety tether line and carabiner attached.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 December 2024 Resolved
Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. MI observed 01 crew were unable to furnish valid medical certificates. 46 CFR 10.301(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 21 December 2024
Resolution: Recieved Photo of Medical Certificate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2024 Resolved
At each initial an subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition... Electrical Cable. MI observed an exposed electrical cable in the engine compartment. Remove or cap the exposed cable. old 46 CFR 179.15-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 16 December 2024
Resolution: Recieved photo of capped cable.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2021 Resolved
A Certificate of Inspection is valid for 5 years for all other vessels. Upon administrative review, MI discovered vessel overdue for renewal inspection. Vessel shall not operate with passengers until completion of renewal inspection. 46 CFR 176.107 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2021
Resolved 4 January 2022
Resolution: Completed COI inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 December 2018 Resolved
First aid kit onboard missing required items. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2018
Resolved 2 January 2019
Resolution: Owner provided first aid kit with all required contents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2018 Resolved
Two (02) electrical submersible bilge pumps did not have shutoff valves at hull penetration. 46 CFR 182.520(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2018
Resolved 2 January 2019
Resolution: Owner provided proof of two (02) metallic shut off valves at hull penetrations for both electrical submersible bilge pumps.
Construction/Loadline › Hull › Side Shell
Issued 3 October 2017 Resolved
Repair bubbles on bow in fiberglass. 46CFR176.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 9 October 2017
Resolution: Fiberglass repaired to the satisfaction of the Marine Inspector.
Engineering › Non-conventional Propulsion/Steering › Propeller (z-drive)
Issued 3 October 2017 Resolved
Remove prop for key inspection. 46CFR176.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 9 October 2017
Resolution: Prop shaft key replaced to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Door
Issued 3 October 2017 Resolved
Repair forward compartment door trim. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 5 October 2017
Resolution: Wood door trim replaced to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 3 October 2017 Resolved
Repair aft corner rub rail on strbd side. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 18 October 2017
Resolution: Aft strbd side corner rub rail repaired to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 3 October 2017 Resolved
Repair wood by ladder on strbd side. 46CFR176.610
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 20 October 2017
Resolution: Ladder repaired to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 3 October 2017 Resolved
Repair/renew wood in machinery space. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 18 October 2017
Resolution: Wood repalced in the machinery space to the satisfaction of the Marine Inspector.
Fire Fighting › Ventilation Systems › Ducts
Issued 13 December 2016 Resolved
Provide engine room ventilation closure devices and mount in vicinity of engine room ventilation louvers. 46 CFR 182.460(l)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 23 December 2016
Resolution: Operator has installed ventilation covers IWO all engine room vents using Velcro material.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 December 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 6 December 2016 Resolved
Provide random testing results for Dimitrios Lekakis iaw 46 CFR 16.230.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: Provided random testing results for Dimitrios Lekakis.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 December 2016 Resolved
Provide documentation that crew members have received EAP training iaw 46 CFR 16.401(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: Provided documentation that all crew members received EAP trainnig. O/O had training materials on hand.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 December 2016 Resolved
Provide company drug testing policy letter iaw 46 CFR 16.401(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 13 December 2016
Resolution: Provided company policy letter on drug testing. In binder with all other DAPI documentation.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 December 2016 Resolved
Provide documentation that crew members have signed company policy iaw 46 CFR 401(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: All crew members have signed company policy on drug testing. Signed policy letters are kept in vessel's DAPI binder.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 December 2016 Resolved
Provide name and contact information for employers substance abuse professional iaw 46 CFR 16.401(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 13 December 2016
Resolution: O/O has subtance abuse professional information accesible for employeese to use.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 December 2016 Resolved
Provide 5/16 inch diameter line to ring bouy iaw 46CFR180.70(c).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 13 December 2016
Resolution: Replaced line to meet 46 CFR 180.70
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 6 December 2016 Resolved
Prove proper operation of navigation lights iaw navigation rules; mast head light iaw 46 CFR 183.420.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 13 December 2016
Resolution: Mast head light bulb replaced. Proved proper operation of all navigations lights.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 December 2016 Resolved
Provide crew training on man overboard procedures iaw 46 CFR 185.520(a).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 13 December 2016
Resolution: Master and crew members completed satisfactory man overboard recovery drill.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 November 2016 Resolved
Vessel is beyond annual inspection window. A new COI inspection needs to be completed prior to operation. 46CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2016
Resolution: Completed COI exam, issued certificate.

Ownership record