Inspection history · 17
24 November 2025
Administrative Inspection · Vessel Attendance · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8273444
17 September 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8236200
11 December 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8038795
18 December 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7833712
11 October 2023
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7799469
8 May 2023
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7684316
13 December 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7599004
7 December 2021
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7363719
8 October 2021
Hull Examination · Deficiency Check · Internal Structural Exam · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7300583
15 December 2020
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7102114
22 November 2019
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6860879
17 October 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6826673
4 December 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6591658
15 December 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6324244
24 August 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6250266
6 December 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6054833
28 November 2016
Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6048760
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 December 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed STBD side navigational light nonoperational. Repair STBD side navigational light to meet International and Inland Navigation Rules standard and to the satisfaction of the attending MI. Vessel restricted to daytime operations. Repair within two weeks.
46 CFR 183.420
Action required: 705 - Other - as specified
Due 23 December 2025
Resolved 19 December 2025
Resolution: Recieved photos of operational PORT, STBD, and masthead light.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 December 2025
Resolved
A vessel of not more than 65 feet in length is not required to carry a rescue boat unless: (1) The vessel carries passengers on an open or partially enclosed deck; and
(2) The cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. MI observed crewmember using MOB recovery ladder without sufficient means to secure oneself to the vessel during MOB recovery operations. Configure MOB recovery crewmember's lifejacket with adequate means to secure oneself to the vessel. Provide satisfactory proof of implementation to the attending [name withheld] within two weeks.
46 CFR 180.210 (b) (1) & (2)
Action required: 705 - Other - as specified
Due 23 December 2025
Resolved 10 December 2025
Resolution: New lifejacket acquired with safety tether line and carabiner attached.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 December 2024
Resolved
Medical certificates issued to all other mariners will
be issued for a maximum period of 5 years. MI observed
01 crew were unable to furnish valid medical
certificates.
46 CFR 10.301(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 21 December 2024
Resolution: Recieved Photo of Medical Certificate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2024
Resolved
At each initial an subsequent inspection for
certification the marine inspector shall examine and
test the following items to the extent necessary to
determine that they are in proper operating condition...
Electrical Cable. MI observed an exposed electrical
cable in the engine compartment. Remove or cap the
exposed cable.
old 46 CFR 179.15-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 16 December 2024
Resolution: Recieved photo of capped cable.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2021
Resolved
A Certificate of Inspection is valid for 5 years for all other vessels.
Upon administrative review, MI discovered vessel overdue for renewal inspection. Vessel shall not operate with passengers until completion of renewal inspection.
46 CFR 176.107 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2021
Resolved 4 January 2022
Resolution: Completed COI inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 December 2018
Resolved
First aid kit onboard missing required items.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2018
Resolved 2 January 2019
Resolution: Owner provided first aid kit with all required contents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2018
Resolved
Two (02) electrical submersible bilge pumps did not have shutoff valves at hull penetration.
46 CFR 182.520(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2018
Resolved 2 January 2019
Resolution: Owner provided proof of two (02) metallic shut off valves at hull penetrations for both electrical submersible bilge pumps.
Construction/Loadline › Hull › Side Shell
Issued 3 October 2017
Resolved
Repair bubbles on bow in fiberglass. 46CFR176.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 9 October 2017
Resolution: Fiberglass repaired to the satisfaction of the Marine Inspector.
Engineering › Non-conventional Propulsion/Steering › Propeller (z-drive)
Issued 3 October 2017
Resolved
Remove prop for key inspection. 46CFR176.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 9 October 2017
Resolution: Prop shaft key replaced to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Door
Issued 3 October 2017
Resolved
Repair forward compartment door trim. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 5 October 2017
Resolution: Wood door trim replaced to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 3 October 2017
Resolved
Repair aft corner rub rail on strbd side. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 18 October 2017
Resolution: Aft strbd side corner rub rail repaired to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 3 October 2017
Resolved
Repair wood by ladder on strbd side. 46CFR176.610
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 20 October 2017
Resolution: Ladder repaired to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 3 October 2017
Resolved
Repair/renew wood in machinery space. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 18 October 2017
Resolution: Wood repalced in the machinery space to the satisfaction of the Marine Inspector.
Fire Fighting › Ventilation Systems › Ducts
Issued 13 December 2016
Resolved
Provide engine room ventilation closure devices and mount in vicinity of engine room ventilation louvers. 46 CFR 182.460(l)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 23 December 2016
Resolution: Operator has installed ventilation covers IWO all engine room vents using Velcro material.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 December 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 6 December 2016
Resolved
Provide random testing results for Dimitrios Lekakis iaw 46 CFR 16.230.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: Provided random testing results for Dimitrios Lekakis.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 December 2016
Resolved
Provide documentation that crew members have received EAP training iaw 46 CFR 16.401(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: Provided documentation that all crew members received EAP trainnig. O/O had training materials on hand.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 December 2016
Resolved
Provide company drug testing policy letter iaw 46 CFR 16.401(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 13 December 2016
Resolution: Provided company policy letter on drug testing. In binder with all other DAPI documentation.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 December 2016
Resolved
Provide documentation that crew members have signed company policy iaw 46 CFR 401(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 13 December 2016
Resolution: All crew members have signed company policy on drug testing. Signed policy letters are kept in vessel's DAPI binder.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 December 2016
Resolved
Provide name and contact information for employers substance abuse professional iaw 46 CFR 16.401(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 13 December 2016
Resolution: O/O has subtance abuse professional information accesible for employeese to use.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 December 2016
Resolved
Provide 5/16 inch diameter line to ring bouy iaw 46CFR180.70(c).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 13 December 2016
Resolution: Replaced line to meet 46 CFR 180.70
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 6 December 2016
Resolved
Prove proper operation of navigation lights iaw navigation rules; mast head light iaw 46 CFR 183.420.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 13 December 2016
Resolution: Mast head light bulb replaced. Proved proper operation of all navigations lights.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 December 2016
Resolved
Provide crew training on man overboard procedures iaw 46 CFR 185.520(a).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2016
Resolved 13 December 2016
Resolution: Master and crew members completed satisfactory man overboard recovery drill.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 November 2016
Resolved
Vessel is beyond annual inspection window. A new COI inspection needs to be completed prior to operation. 46CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2016
Resolution: Completed COI exam, issued certificate.