This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
244 - Simplified, Gross Ton
244 - Simplified, Net Ton
Maury page id
psix-34222
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 31
20 November 2023Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7830178
25 October 2022Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7580275
11 January 2022Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7378499
23 October 2020COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7083286
26 December 2019Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6879094
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 October 2022Resolved
Non-metallic flexible hose must be IAW SAE J1942. Found fuel line on prime mover to be cracked. Line requires replacement.
CITE 46CFR56.60-25(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2022
Resolved 28 October 2022
Resolution: Received photo evidence of rectified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2022Resolved
Gears and rotating machinery shall be provided with adequate covers and guards. Guard over rotating machinery on prime mover cracked through. Requires repair.
Cite 46 CFR 58.01-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2022
Resolved 28 October 2022
Resolution: Received photo evidene of rectified deficiency.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 6 December 2013Resolved
Route is restricted to LAKES BAYS and SOUNDS until ABS endorses loadline certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 December 2019
Resolution: Verified ABS endorsed ILL