STAR BREEZE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2019, most recently in June 2023, along with 6 deficiencies and 2 operational controls.
Records from 2019 to 2023. Most recent: inspection, 9 June 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it12969 - Convention (Subpart B), Gross Ton 4155 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
9 June 2023COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7703973
5 June 2023Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7703874
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 June 2023Resolved
07105 - Fire doors in main vertical zone bulkheads and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall be of the self-closing type. Fire door 3.3.620A did not latch in the closed position and fire door 6.2.354 only partially closed. 74 SOLAS 81 Amend II-2/30.4 (10c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 June 2023
Resolution: Doors were fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 June 2022Resolved
Indicators shall be fitted on the navigation bridge for...propeller speed and pitch position in the case of controllable pitch propellers. Vessel port-side CPP is displaying 40 degrees as maximum pitch on bridge indicator. Dive survey conducted on 14JUN2022 indicates that CPP is fully functional, however indicator is reporting incorrect pitch position to bridge display. SOLAS 2004 CONS. II-1/ 49.6.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2022
Resolved 16 June 2022
Resolution: Received/reviewed tech statement, CPP tested in full ahead, astern and at 0 pitch.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 April 2022Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause and appropriate action is taken. 8” wide temporary fiberglass patch found on 4” diameter auxiliary salt water cooling system outlet, supplying cooling water to critical main propulsion reduction gear, fuel coolers and reefers. Patch placed on cooling line in August 2021. No required reports made to company or class society. Parts received on board in December 2021. Crew has still not taken action to make permanent repairs for 4 months. Further, Main engine lube oil purifiers found out of service for 6 months. Main engine lube oil purifiers found on continuous survey machinery list which requires vessel to notify Class if an issue is found. Ship acknowledged no notification to Class – confirmed by Class (BV) representative onboard. Not making proper reports mitigates the purpose of the SMS which provides safe practices in ship operation and a safe working environment.
NOTE: All deficiencies are of a technical and operational nature which collectively provide objective evidence of a serious failure, or lack of effectiveness in implementation of the ISM Code. Sector San Diego requires as ISM audit to be conducted within the scope of maintenance and reporting of non-conformities.
Action required: 30 - Ship detained
Due 20 April 2022
Resolved 3 May 2022
Resolution: Class issued a PR17 requiring audit to be completed within 14 days so deficiency due date was changed to 5/4/2022. On 5/3/22 an audit report was received reflecting a non-conformity found.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 20 April 2022Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. Company should establish procedures, plans and instructions for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Vessel conducted non-routine 14 day cruise operation whereby garbage was generated beyond ship’s capacity to properly store it – garbage management plan does not address such a situation. Garbage found in steering gear room (a category 10 space where storage of combustible is prohibited) and above sprinkler heads in garbage room and adjacent garbage holding room – filled completely to the ceiling.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 20 April 2022
Resolution: All garbage stored in S/G room was removed from vessel, garbage from handling and storage room was reduced below fire sprinkler height limit and removal of garbage was continuing at PSCO departure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 April 2022Resolved
The purpose of this regulation is to contain a fire in the space of origin. The fire integrity of the divisions shall be maintained at openings and penetrations. Observed the following fire doors not sealing correctly or missing gasket sealing materials: Door 291, 286 and A214. Door 594 (emergency escape trunk from machinery space) self-closing device is not operational and will not remain shut due to also having a broken latch. SOLAS 74am (04 Cons Ed) II-2/9.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 3 May 2022
Resolution: Received class report - doors repairs to satisfaction of class. Def cleared.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 April 2022Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. 1) Pinhole leak found on fire main topping up pump supply pipe. 2) 2” diameter circle bulkhead penetration in purifier room. 3) Two pinhole leaks found on steam condenser piping with jubilee patches. 4) Excessive water and hydraulic fluid found under port and starboard steering gear. 5) General alarm light on alarm column in purifier flat non-operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 3 May 2022
Resolution: Line items repaired to class satisfaction or issued a condition of class. Def cleared.