MAURY USCG vessel records Sign in
← All vessels

STAR BREEZE

STAR BREEZE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 1989, most recently in June 2023, along with 12 deficiencies and 2 operational controls.

Records from 1989 to 2023. Most recent: inspection, 9 June 2023.

Built
1989
Last inspected
9 June 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8807997 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
342327
Flag
BAHAMAS, THE
—
Maury page id
psix-342327

Inspections, by type

…with no type recorded12
Years with a record 14 calendar years (1989–2023)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it12969 - Convention (Subpart B), Gross Ton
4155 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

9 June 2023 COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7703973
5 June 2023 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7703874
13 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7577060
19 September 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7562032
10 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7530057
14 June 2022 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7477782
20 April 2022 COC-CVE Annual · PSC A · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7429058
10 June 2021 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7221634
21 October 2019 COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6838429
9 December 2011 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4203813
26 January 2009 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3400366
31 December 2008 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3397524
20 August 2002 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1710565
28 June 2002 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1710758
19 June 2002 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1633491
17 May 2002 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1707824
9 May 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1616179
29 March 2002 Letter of Compliance (Initial/Renewal)
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1599495
6 March 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1407624
7 December 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385372
6 December 1995 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404050
20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 1192922
15 September 1995 Control Verification · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187392
1 September 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 957984
19 December 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347982
19 December 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958343
19 December 1991 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1263870
16 October 1991 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 346514
16 September 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006135
15 September 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1003451
8 March 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 925928
5 December 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 491568
5 December 1990 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228251
3 March 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335693
3 March 1990 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 918234
22 November 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1222217

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 June 2023 Resolved
07105 - Fire doors in main vertical zone bulkheads and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall be of the self-closing type. Fire door 3.3.620A did not latch in the closed position and fire door 6.2.354 only partially closed. 74 SOLAS 81 Amend II-2/30.4 (10c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 June 2023
Resolution: Doors were fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 June 2022 Resolved
Indicators shall be fitted on the navigation bridge for...propeller speed and pitch position in the case of controllable pitch propellers. Vessel port-side CPP is displaying 40 degrees as maximum pitch on bridge indicator. Dive survey conducted on 14JUN2022 indicates that CPP is fully functional, however indicator is reporting incorrect pitch position to bridge display. SOLAS 2004 CONS. II-1/ 49.6.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2022
Resolved 16 June 2022
Resolution: Received/reviewed tech statement, CPP tested in full ahead, astern and at 0 pitch.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 April 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause and appropriate action is taken. 8” wide temporary fiberglass patch found on 4” diameter auxiliary salt water cooling system outlet, supplying cooling water to critical main propulsion reduction gear, fuel coolers and reefers. Patch placed on cooling line in August 2021. No required reports made to company or class society. Parts received on board in December 2021. Crew has still not taken action to make permanent repairs for 4 months. Further, Main engine lube oil purifiers found out of service for 6 months. Main engine lube oil purifiers found on continuous survey machinery list which requires vessel to notify Class if an issue is found. Ship acknowledged no notification to Class – confirmed by Class (BV) representative onboard. Not making proper reports mitigates the purpose of the SMS which provides safe practices in ship operation and a safe working environment. NOTE: All deficiencies are of a technical and operational nature which collectively provide objective evidence of a serious failure, or lack of effectiveness in implementation of the ISM Code. Sector San Diego requires as ISM audit to be conducted within the scope of maintenance and reporting of non-conformities.
Action required: 30 - Ship detained
Due 20 April 2022
Resolved 3 May 2022
Resolution: Class issued a PR17 requiring audit to be completed within 14 days so deficiency due date was changed to 5/4/2022. On 5/3/22 an audit report was received reflecting a non-conformity found.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 20 April 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. Company should establish procedures, plans and instructions for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Vessel conducted non-routine 14 day cruise operation whereby garbage was generated beyond ship’s capacity to properly store it – garbage management plan does not address such a situation. Garbage found in steering gear room (a category 10 space where storage of combustible is prohibited) and above sprinkler heads in garbage room and adjacent garbage holding room – filled completely to the ceiling.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2022
Resolved 20 April 2022
Resolution: All garbage stored in S/G room was removed from vessel, garbage from handling and storage room was reduced below fire sprinkler height limit and removal of garbage was continuing at PSCO departure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 April 2022 Resolved
The purpose of this regulation is to contain a fire in the space of origin. The fire integrity of the divisions shall be maintained at openings and penetrations. Observed the following fire doors not sealing correctly or missing gasket sealing materials: Door 291, 286 and A214. Door 594 (emergency escape trunk from machinery space) self-closing device is not operational and will not remain shut due to also having a broken latch. SOLAS 74am (04 Cons Ed) II-2/9.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 3 May 2022
Resolution: Received class report - doors repairs to satisfaction of class. Def cleared.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. 1) Pinhole leak found on fire main topping up pump supply pipe. 2) 2” diameter circle bulkhead penetration in purifier room. 3) Two pinhole leaks found on steam condenser piping with jubilee patches. 4) Excessive water and hydraulic fluid found under port and starboard steering gear. 5) General alarm light on alarm column in purifier flat non-operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 3 May 2022
Resolution: Line items repaired to class satisfaction or issued a condition of class. Def cleared.
Construction/Loadline › Structures › Door
Issued 9 December 2011 Resolved
0999 - The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. Approximately 80% of the fire doors tested closed at a rate that could cause injury to a person in the way of the door (less than 2 seconds). 74 SOLAS (81) II-2/30.4
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 January 2012
Resolved 30 December 2011
Resolution: Received e-mail from captain of vessel attesting to adjustments made to doors throughout the ship to slow down the rate of closure.
Construction/Loadline › Structures › Door
Issued 9 December 2011 Resolved
0710 - It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. All fire doors are only able to be closed on one side of the door. 74 SOLAS (81) II-2/30.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2012
Resolved 30 December 2011
Resolution: Received e-mail from DNV attesting to the approval of the arrangement, as the location of the closure switches are on the side of the door in the direction of the primary escape path.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 December 2011 Resolved
0710 Fire doors in main vertical zone bulkheads and stairway enclosures...shall be of the self-closing type and capable of closing against an inclination of 3.5 degrees opposing closure. Fire door 340 (double leaf door in main passenger stairway) does not close automatically when the local door release is activated. 74 SOLAS (81), II-2/30.4.
Action required: 705 - Other - as specified
Due 16 December 2011
Resolved 12 December 2011
Resolution: Received email confirming repair of door.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 7 December 2011 Resolved
1499 The angular position of the rudder shall: if the main steering gear is power-operated, be indicated on the navigation bridge... and be recognizable in the steering gear compartment. Angle indicators on bridge and steering gear room differ by more than 5 degrees.
Action required: 705 - Other - as specified
Due 9 January 2012
Resolved 14 December 2011
Resolution: Recieved report of proper repair from vessel''s Master
Navigation
Issued 19 December 1991 Resolved
The vessels maneuvering fact sheet was incomplete in that the time and distance to stop at half speed, and the speeds at which the bow thruster iseffective were missing.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Navigation
Issued 5 December 1990 Resolved
REPAIR AND PROVE PROPER OPERATION OF LOSS OF POWER ALARMS ON BRIDGE CONSOLEPANEL FOR STEERING MOTORS 1,2,3, AND 4 AS PER SOLAS CHAPTER 2-1, REG. 29, PART 5.2.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990

Ownership record