MAURY USCG vessel records Sign in
← All vessels

KIBELE

KIBELE is a 2000 freight ship. The Coast Guard has recorded 24 inspections since 2000, most recently in September 2010, along with 10 deficiencies and 4 operational controls.

Records from 2000 to 2010. Most recent: inspection, 17 September 2010.

Built
2000
Last inspected
17 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9217797 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
TURKEY
—
Maury page id
psix-3424

Inspections, by type

…with no type recorded11
Years with a record 9 calendar years (2000–2010)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it7265 - Simplified, Gross Ton
7265 - Convention (Subpart B), Gross Ton
4279 - Convention (Subpart B), Net Ton
15324 - Displacement, Metric Ton
12235 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

17 September 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3847365
2 December 2009 ISPS III Exam · PII Safety Exam · Deficiency Check · Administrative Inspection · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3640402
3 July 2006 ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2699696
2 July 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2698041
6 June 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2672159
10 February 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2582815
10 February 2006 ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2582884
12 July 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2423823
12 April 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2332329
10 March 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307050
26 October 2004 PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2228831
28 June 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2113289
22 April 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2049904
20 April 2004 MARPOL Annex I Examination · Re-Inspection · MARPOL Annex V Examination · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2048427
19 April 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2047940
1 October 2003 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1918350
20 June 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1822432
8 January 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1727782
21 November 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1706393
29 June 2002 Control Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1640207
24 April 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1609312
7 April 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 288489
5 June 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278568
5 April 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 276590

Deficiency record · 10

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 December 2009 Resolved
Automatic Oil Drain on OWS is inoperable. The vessel is required to maintain equipment and conform with the provisions of the Convention. MARPOL 06, Annex I, Reg. 6.4.1.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 13 April 2010
Resolution: Received class report and survey attesting to ship''s pollution prevention equipment.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 December 2009 Resolved
1530 Vessels of 3000 gross tons or more required to be fitted with 02 indipendent operating radars for surface navigation. Secondary radar was found inoperable. (CFR 164.37) (A)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2009
Resolved 8 December 2009
Resolution: Attended VSL, witnessed satisfactory operation of 3cm radar.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 October 2004 Resolved
Fluorescent light bulbs for the main and emergency lighting system are missing and/or burned out throughout the ship. SOLAS 74 amended Chapter II-2 regulation 41
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 1 November 2004
Resolution: Recieved invoice from supplier.
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 26 October 2004 Resolved
The emergency generator electrical distribution system is indicating an abnormal level of insulation far exceeding the allowable limit. SOLAS 74 amended Chapter II-1 regulation 45
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2004
Resolution: Recieved class report.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 26 October 2004 Resolved
2 EEBD's located in the engine room were found empty with no spares on board to replace them.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 1 November 2004
Resolution: Recieved report from unitor.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 19 April 2004 Resolved
Vessel failed to provide departure time 96 hrs prior to arrival.
Due 19 April 2004
Resolved 19 April 2004
Resolution: Update was submitted to SANS.
Documentation › Certificates/Documents
Issued 1 October 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 4 October 2003
Resolution: RECIEVED FAXED COPY OF ENDORSED AND STAMPED COPY OF CLASSIFICATION DOCUMENT, VESSEL CLEARED TO SAIL
Engineering › Steering Gear System
Issued 24 April 2002 Resolved
Rudder carrier bush has excessive clearance. Approx 2.65mm against original 0.70mm. Rudder neck bush bearing clearance is worn approx 2.65mm against original 1.50mm causing binding and slipping of the rudder. Class report issued condition to be rectified at next dry dock. 14MAR03 see pdf cls rpt. LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 20 June 2003
Resolution: Received class report from NKK satisfying requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 April 2002 Resolved
Bunker line has not been tested in accordance with 33 CFR 156.170. Last annual test was 15MAR2000. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 24 April 2002
Resolved 26 April 2002
Resolution: Bunker line was tested SWT at 6.0kg 1.5 times MAWP. MAWP is 4.0 kg. Vessel is now allowed to bunker in U.S. waters.
Fire Fighting
Issued 7 April 2001 Resolved
Conducted fire drill. Crew was not familiar with responsibilities. One air bottle was empty.
Condition: Unknown
Due 8 April 2001
Resolved 11 April 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.