MAURY USCG vessel records
← All vessels

CAPT MIKE

CAPT MIKE is a 1988 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in February 2026, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 10 February 2026.

Built
1988
Last inspected
10 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDN6316
342531
Flag
UNITED STATES
Maury page id
psix-342531

Inspections, by type

…with no type recorded5
Years with a record 11 calendar years (2016–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)52.0 ft × 17.4 ft × 7.7 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVIS BOAT WORKS INC · PANAMA CITY, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 23 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 29

10 February 2026 Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8308951
12 January 2026 Drydock Exam · Vessel Attendance · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8295034
14 August 2025 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 8214130
13 February 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8079268
22 August 2024 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 7989336
20 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7867591
17 January 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam · Special Consideration
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7850542
2 October 2023 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7802007
9 February 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7634969
27 October 2022 Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7585193
13 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7558000
25 February 2022 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397930
19 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7382536
22 September 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7317790
8 March 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7152000
4 March 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6920831
22 January 2020 Administrative Inspection · Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6894122
16 October 2019 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6835940
3 August 2019 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6786721
11 March 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6640355
14 November 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580541
7 March 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6366672
22 January 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340387
28 September 2017 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6293340
1 March 2017 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6093380
21 April 2016 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 5859712
21 March 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5832975
3 February 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815135
8 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5795492

Deficiency record · 3

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019 Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 22 January 2020
Resolution: SATISFACTORY IN SERVICE INSPECTION CONDUCTED ON THIS DATE
Engineering › Fuel Oil Service System › Tank
Issued 28 September 2017 Resolved
Vessel had a leak and needed repairs on STBD fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 22 January 2018
Resolution: Witnessed repaired tanks full of fuel and in stalled in the vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 January 2016 Resolved
Complete a credit hull exam. Vessel hull exam is overdue as of 06Jan16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2016
Resolution: Vessel received credit hull exam

Ownership record