MAURY USCG vessel records Sign in
← All vessels

NATTY

NATTY is a 1982 freight ship. The Coast Guard has recorded 25 inspections since 1989, most recently in August 2008, along with 26 deficiencies and 4 operational controls.

Records from 1989 to 2008. Most recent: inspection, 12 August 2008.

Built
1982
Last inspected
12 August 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8132859 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
342533
Flag
PANAMA
—
Maury page id
psix-342533

Inspections, by type

…with no type recorded19
Years with a record 16 calendar years (1989–2008)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39663 - Convention (Subpart B), Gross Ton
23360 - Convention (Subpart B), Net Ton
64824 - Dead Weight, Ton
82614 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

12 August 2008 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3289032
14 April 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3183841
10 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3181754
23 January 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3134960
14 November 2007 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3094241
23 November 2004 ISPS II Exam · Ballast Water Examination · ILO-147 Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · STCW 95 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2246577
12 November 2003 Annual Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1946614
21 May 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1620912
19 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 53387
16 February 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 287382
11 August 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 280653
3 August 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 431383
5 July 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 417621
16 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 695189
9 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 389892
13 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382934
10 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 23052
10 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143742
18 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 364788
13 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 364734
8 August 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 513318
21 January 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 355628
16 January 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 475344
4 June 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 344168
28 December 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 334572

Deficiency record · 26

Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 April 2008 Resolved
Winch - Damaged By Earlier Event
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 April 2008
Resolution: Received class report from China Classification Society satisfying requirement.
Construction/Loadline › Hull › Weld
Issued 14 November 2007 Resolved
During the course of a PSC inspection, oil residue was observed leaking from a horizontal weld seam on or around frame No.30 or the No.30 starboard heavy fuel oil spare tank on the starboard quarter side of the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2008
Resolved 3 January 2008
Resolution: Received class report from China Classification Society satisfying requirement
Engineering › Steering Gear System
Issued 12 November 2003 Resolved
Starboard steering ram (aft) is leaking excessively. Hydraulic oil is leaking at an approximate rate of 10-15 drops per second. LEGACY COMPONENT DESC: Ram Seal
Action required: 705 - Other - as specified
Due 12 November 2003
Resolved 13 November 2003
Resolution: Crew renewed the gasket inside the steering ram. Satisfactory inspection and test of the steering gear was carried out by the CCS Surveyor.
Navigation › Piloting/Steering
Issued 12 November 2003 Resolved
Steering gear system's loss of power alarms, do not function as per system design. LEGACY COMPONENT DESC: Alarms
Action required: 705 - Other - as specified
Due 19 November 2003
Resolved 13 November 2003
Resolution: Crew made repairs and the steering gear loss of power alarms were tested to the satisfaction of the CCS Surveyor.
Accommodation/Occupational Safety › Potable Water System › General
Issued 12 November 2003 Resolved
Hot and cold water piping that runs though-out the engine room compartment has been altered from original design. Condition of class was assigned for piping to be altered in accordance with the original layout and dimension no later than 11JAN2004.
Action required: 705 - Other - as specified
Due 11 January 2004
Resolved 14 November 2007
Resolution: Corrected during Feb. 2007 drydock.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 12 November 2003 Resolved
The purifier, generator, and injector test station compartments watertight door handles/locking devices are not installed. Condition of class was assigned by CCS for these devices to be installed no later than 11JAN04.
Action required: 705 - Other - as specified
Due 11 January 2004
Resolved 14 November 2007
Resolution: Items were corrected during Feb. 2007 drydock.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 November 2003 Resolved
Propulsion engine cooling water pump motor improperly wired. Electrical conductors are exposed outside of the junction box.
Action required: 705 - Other - as specified
Due 19 November 2003
Resolved 13 November 2003
Resolution: Vessel crew restored the electrical conductors back into the junction box and the CCS Surveyor inspected satisfactory.
Accommodation/Occupational Safety
Issued 16 February 2001 Resolved
THE M/V FEILONGS TOILET IN THE DOCTORS CABIN/OFFICE NEXT TO THE HOSPITAL ISBROKEN AND UNWORKABLE UNDER ILO 147 STANDARDS. VSL IS MAKE REPAIRS PRIOR TO19 MAR 01.
Condition: Unknown
Due 19 March 2001
Resolved 12 November 2003
Resolution: Toilet was tested satisfactory.
Electrical
Issued 5 July 1998 Resolved
REPLACE PROTECTIVE COVERING FOR LIGHT FIXTURES IN EMERGENCY FIRE PUMP ROOM PRIOR TO NEXT U. S. PORT.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Construction/Loadline
Issued 5 July 1998 Resolved
PROVIDE CLASS CERTIFICATION OF SATISFACTORY REPAIRS TO STRESS FRACTURES IN WAY OF #4, #5 AND #6 CARGO HOLDS PRIOR TO NEXT U. S. PORT.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Navigation
Issued 9 April 1996 Resolved
COAST PILOT NOT CORRECTED. THE COAST PILOT HAD NO CORRECTIONS IN IT. VESSELOBTAINED A CORRECTED U.S. COAST PILOT PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Navigation
Issued 9 April 1996 Resolved
THE VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD. VESSEL OBTAINED INLAND NAVIGATION RULES PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Fire Fighting
Issued 13 September 1995 Resolved
VESSEL NEEDS TO MAKE PROPER AND PERMENANT REPAIRS TO EMERGENCY FIRE PUMP PRIME LINE.
Condition: Unknown
Due 20 September 1995
Resolved 19 September 1995
Navigation
Issued 13 September 1995 Resolved
VESSEL NEEDS TO MAKE PROPER AND PERMENANT REPAIRS TO STBD STEERING GEAR UNIT CURRENTLY LEAKING FLUID.
Condition: Unknown
Due 20 September 1995
Resolved 19 September 1995
Electrical
Issued 13 September 1995 Resolved
VESSEL NEEDS TO MAKE PERMENANT AND PROPER REPAIRS TO S/S GENERATOR F/O RETURN SYSTEM.
Condition: Unknown
Due 20 September 1995
Resolved 19 September 1995
Engineering
Issued 13 September 1995 Resolved
VESSEL NEEDS TO MAKE PROPER AND PERMENANT REPAIRS TO OIL SYSTEM STBD SIDE LOWER LEVEL AFT. OIL CANISTER LEAKING INTO BILGES.
Condition: Unknown
Due 20 September 1995
Resolved 19 September 1995
Unknown
Issued 18 February 1994 Resolved
VESSEL HAS OVERBOARD CONTAINER FULL OF GARBAGE MIXED WITH PLASTIC. CHIEF MATE STATED THAT THE CONTAINER IS DUMPED OVERBOARD WHEN UNDERWAY. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Navigation
Issued 13 February 1994 Resolved
US COAST PILOT VOL 5 OR BRITISH ADMIRILTY 69A NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Fire Fighting
Issued 13 February 1994 Resolved
VESSEL HAD 2 HOSES MISSING AT THE FIRE FIGHTING STATIONS ON DECK.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Navigation
Issued 13 February 1994 Resolved
US COAST GUARD LIGHT LIST VOL. IV OR FOREIGN EQUIVALENT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Navigation
Issued 21 January 1993 Resolved
REQUIRED CHART 11370 NOT ON BOARD.
Condition: Unknown
Due 30 January 1993
Resolved 21 January 1993
Navigation
Issued 21 January 1993 Resolved
U.S. COAST PILOT OR FOREIGN EQUIVALENT NOT ON BOARD.
Condition: Unknown
Due 30 January 1993
Resolved 21 January 1993
Navigation
Issued 21 January 1993 Resolved
FOREIGN EQUIVALENT LIGHT LIST BRITISH ADMIRALITY VOLUME J DATED 1979, NOT CORRECTED.
Condition: Unknown
Due 30 January 1993
Resolved 21 January 1993
Navigation
Issued 4 June 1991 Resolved
33 CFR 164.30 THIS VESSEL OVER 1600 G.T. ENTERED THE PORT OF CORPUS CHRISTI, TEXAS, WITHOUT A CURRENT EDITION OR APPLICABLE CURRENT EXTRACT OF TIDAL CURRENT TABLES FOR THE AREA TO BE TRANSITED, AS REQUIRED PER 33 CFR 164.(A)(3)(ii).
Condition: Unknown
Due 5 June 1991
Resolved 4 June 1991
Navigation
Issued 4 June 1991 Resolved
33 CFR 164.30 THIS VESSEL OVER 1600 G.T. ENTERED THE PORT OF CORPUS CHTISTI, TEXAS, WITHOUT A CURRENT EDITION OR APPLICABLE CURRENT EXTRACT OF THE TIDE TABLES FOR THE AREA TO BE TRANSITED AS REQUIRED BY, 33CFR 164.33(a)(3)(i).
Condition: Unknown
Due 5 June 1991
Resolved 4 June 1991
Documentation
Issued 4 June 1991 Resolved
33 CFR 130.3(A) THIS VESSEL OVER 300 G.T. OPERATED IN THE CORPUS CHRISTI SHIP CHANNEL, THE NAVIGABLE WATER OF THE UNITED STATES, WITHOUT HAVING A CERTIFICATE OF FINANCIAL RESPONSIBILITY TO COVER THE VESSEL AND IT'S OPERATOR.
Condition: Unknown
Due 5 June 1991
Resolved 4 June 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.