Documentation record
Registered dimensions (L × B × D)72.0 ft × 21.0 ft × 6.5 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS OF STUART,IN · STUART, FL, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 25 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 22
22 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8353209
6 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8136991
23 April 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7899326
8 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7879658
11 January 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847146
25 April 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7675099
21 April 2022
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7459046
11 April 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7426612
1 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7400579
26 August 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7297033
9 March 2021
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7150417
26 May 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6894443
3 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6894446
3 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6828117
8 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6688880
27 February 2019
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6616100
10 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6366372
1 February 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6342347
18 December 2017
Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6364842
21 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6108604
6 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5848500
14 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5832514
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2026
Resolved
Float light for one of the vessels life floats had alkaline batteries installed, light is required lithium ion. Cleared on the spot.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2026
Resolved 22 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2026
Resolved
Life ring attached line was too short and life ring line connecting float light was too long required correction.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2026
Resolved 22 April 2026
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 May 2025
Resolved
EPIRB Hydrostatic release expired. Limited vessel to less than 3nm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 7 May 2025
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025
Resolved
Lifering was beyond it service life.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2025
Resolved 7 May 2025
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 May 2025
Resolved
Waterlight for one of the life floats was inop. Restricted to daylight ops only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2025
Resolved 7 May 2025
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 May 2025
Resolved
Patch life float where needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 April 2023
Resolved
Install interconnected smoke alarms.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2023
Resolved 1 May 2023
Resolution: Appropriate smoke detectors were installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 April 2023
Resolved
Post Egress plan in overnight accommodations prior to carrying overnight passengers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 25 April 2023
Resolution: posted
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 March 2021
Resolved
Renew bunk room accomodations smoke detector with new approved type.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 9 March 2021
Resolution: Replaced with new approved detector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 March 2021
Resolved
Renew expired EPIRB battery. Prior to operating outside 3NM.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 March 2021
Resolved 9 March 2021
Resolution: Vessel Rep installed new EPIRB and provided proof of registration.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 March 2021
Resolved
Renew expired medication in first aid kit.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 9 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 9 March 2021
Resolved
Re-label paddles in life floats. (Cleared on the Spot)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 9 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 May 2020
Resolved
Life floats on board were lashed down and unable to float free. O/O corrected the deficiency on the spot. Sent the vessel rep NVIC 01-83 for guidance on stowage.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 May 2020
Resolved 26 May 2020
Resolution: Vessel rep freed and cleared the lashing securing the life floats to the pilot house's overead.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 May 2020
Resolved
Provide evidence of weaklink installed on the vessel's painter line for the life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 27 May 2020
Resolution: Vessel rep sent pictures of the tag for the weak link and pictures of the link installed properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Make electrical connections permanent type under console as well disconnect dead end wires. Prior to carrying overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 3 October 2019
Resolution: Made electrical connections permanent type under console as well disconnected dead end wires.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Remove extension cord in aft topside berth starboard side.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 3 October 2019
Resolved 3 October 2019
Resolution: Removed extension cord in aft topside berth starboard side.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2019
Resolved
Mattresses shall be covered with a material which has been treated to give it fire resistant properties. Vessel could not produce evidence of fire resistant properties. Provide evidence or replace mattresses with approved type.
CITE: 46 CFR 177.30-7(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 31 October 2019
Resolution: Replaced mattresses with approved type.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 February 2019
Resolved
Piping at the discharge of the pump does not have a PSI guage IAW CFR 46 CFR 181.10-1(c) (old).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 8 May 2019
Resolution: Guage installed and testes: all SAT
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 February 2019
Resolved
Emergency Egress in bunk room seized. O/O found that they improperly caulked the escape hatch. Crew was able to un-secure and clean the hatch freeing the hatch to open freely.
Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 February 2019
Resolved 27 February 2019
Lifesaving › Visual Distress Signals (General) › Condition
Issued 21 March 2017
Resolved
Water Light for STBD BA was full of rain water and inoperable.
Condition: Damaged By Earlier Event
Due 21 March 2017
Resolved 21 March 2017
Resolution: Corrected on the spot