MAURY USCG vessel records Sign in
← All vessels

MSC NICOLE

MSC NICOLE is a 1989 freight ship. The Coast Guard has recorded 47 inspections since 1990, most recently in March 2010, along with 18 deficiencies and 6 operational controls.

Records from 1990 to 2010. Most recent: operational control imposed, 25 March 2010.

Built
1989
Last inspected
25 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8509387 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
342833
Flag
PANAMA
—
Maury page id
psix-342833

Inspections, by type

…with no type recorded29
Years with a record 18 calendar years (1990–2010)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it31430 - Convention (Subpart B), Gross Ton
13100 - Convention (Subpart B), Net Ton
55748 - Displacement, Ton
41403 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT. MILLIONS II Commercial Fishing Vessel · MISLE 326506 · 13 February 1994 · activity 120498

Inspection history · 47

25 March 2010 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3697941
25 March 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3703033
31 January 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3672880
31 January 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3674387
24 April 2009 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3459653
7 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3390183
16 November 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364126
4 October 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3338388
2 October 2008 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3337136
29 September 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3335066
20 March 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3168390
13 May 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2648223
5 April 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2617399
5 April 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2617890
14 October 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2514346
12 October 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2512615
12 October 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2513543
24 April 2005 MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2340393
27 October 2004 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2229229
8 April 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2040242
8 October 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1922030
5 March 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1749737
30 August 2002 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1667591
15 May 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1617042
3 April 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600444
17 February 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1487157
10 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274677
11 January 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424256
5 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 19703
13 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 411758
11 January 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 411687
3 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 657017
13 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 110886
13 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390498
2 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 388268
23 August 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 657018
21 August 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 381938
28 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 376706
14 February 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 364508
13 February 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 120498
23 July 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 359794
30 July 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 470734
16 August 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 518609
19 February 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 342027
11 December 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 518875
28 June 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 442466
4 January 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 334728

Deficiency record · 18

Electrical › Electric Generation Source (emergency) › Generator
Issued 25 March 2010 Resolved
1499- Other (Prop. & Aux. Machinery)- vsl experienced a blackout condition; nothing was operational including the emergency generator. Emergency generator did not automatically start and could not provide electrical power for 1 hr and 10 min. SOLAS II-1/43.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 26 March 2010
Resolution: Received, reviewed and approved class report from DNV rectifying deficiency. Class report stated: emergency circuit breaker auxiliary contact found with a malfunction (no contact at all), breaker was cleaned, tested and found in good condition.
Electrical › Electric Generation Source (service) › Generator
Issued 25 March 2010 Resolved
1430- Auxiliary Engines- master stated that the 2 running generators were overloaded after attempting to start vsl cranes and experienced a blackout condition. The crew made several unsuccessful attempts to get the generators started. The vsl is relying completely on the emergency generator for power. SOLAS II-1/41.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 26 March 2010
Resolution: Received, reviewed and approved class report from DNV rectifying deficiency. Class report stated: diesel generator valve no.25 was found blocked. The valve was opened and suction line was brought in order, generators tested and found in order.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 31 January 2010 Resolved
Pilot reported a reduction in RPMs while transitting outbound.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 4 February 2010
Resolution: Vessel submitted a class report attesting to the proper repair of turbocharger which caused the reduction in RPMs.
Engineering › Steering Gear System › Solenoid Valve
Issued 2 October 2008 Resolved
Several leaks were noted on steering gear system including on solenoid valve
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 16 November 2008
Resolution: Received Class Report attesting to the repairs on the steering gear.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 2 October 2008 Resolved
Chief Engineer was unable to provide proof of hydrostatic test IAW 33CFR156.170 for bunkering lines. Vessel is prohibited from conducting bunkering operations in US waters until hydrostatic tests have been completed.
Action required: 703 - Prior to bunkering operations
Due 4 October 2008
Resolved 4 October 2008
Resolution: Received Report from the Master attesting to the satisfactory inspection and hydrostatic test of their FO and DO bunkering transfer pipe in accordance to 33CFR156.170
Operations/Management › Ballast Water Managment › Ballast Retention
Issued 12 October 2005 Resolved
Oily water discharged from Ballast Wing Tank #2. Have Classification Society attend the vessel to inspect the integrity and locate the source of the oily water.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2005
Resolution: Received class report stating that the tank was sound. Class also reported that the oily water was from previous port''s ballast activities
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 April 2004 Resolved
Missing section of handrail on second level of engine room. Repaired while inspector was aboard and cleared on the spot.
Due 8 April 2004
Resolved 8 April 2004
Fire Fighting › Structural Fire Protection - General
Issued 8 October 2003 Resolved
Holdback on door to A/C Machinery Room to Accomodation Space LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 9 October 2003
Resolution: Rcvd class report
Fire Fighting › Means of Escape
Issued 8 October 2003 Resolved
Self-closing door to Emergency Generator Room is not working properly. LEGACY COMPONENT DESC: Doorways
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 9 October 2003
Resolution: Rcvd class report
Engineering › Sea-water System (primary cooling)
Issued 8 October 2003 Resolved
Concrete patch on Main s/W line abouve #1 S/W Pump LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 8 April 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 October 2003 Resolved
Main Diesel Engine has temporary repair (duct tape) on F/O line port side.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 9 October 2003
Resolution: Rcvd class report
Engineering › Generator (propulsion/auxiliary-electric)
Issued 8 October 2003 Resolved
F/O leak on #2 SSDG. Approximately 1 gallon/3 minutes. Repair prior to use.
Action required: 705 - Other - as specified
Resolved 9 October 2003
Resolution: Rcvd class report
Accommodation/Occupational Safety › Cooking Systems
Issued 17 February 2002 Resolved
FIRE SCREENS IN GALLEY GREASE FILLED. REPLACE PRIOR TO NEXT PORT.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 28 February 2002
Resolution: CLEARED BY MSO CHAMS
Fire Fighting
Issued 10 February 2000 Resolved
Conduct a satisfactory fire and abandon ship drills in the presence of CG inspectors prior to departure
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Fire Fighting
Issued 11 January 1998 Resolved
INSPECTORS COULD NOT CONDUCT FIRE DRILL OR ABANDON SHIP DRILL.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Documentation
Issued 13 April 1996 Resolved
TWO COMMODITES ON THE VESSELS DANGEROUS CARGO MANIFEST DID NOT LIST THE PACKING GROUPS AND THE TYPE OF PACKAGES AS REQUIRED BY 49CFR176.30(a)(4)(6). THE MASTER WAS ADVISED AND NO CORRECTIVE ACTION WAS NEEDED BECAUSE THE CARGO HAD ALREADY BEEN DISCHARGED.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Documentation
Issued 13 April 1996 Resolved
THE 24-HOUR EMERGENCY RESPONSE TELEPHONE NUMBER LISTED ON THE VESSELS DANGEROUS CARGO MANIFEST WERE NOT IN ACCORDANCE 49CFR176.30(a)(3). THE MASTER WAS ADVISED AS TO THE REGULATIONS. NO CORRECTIVE ACTION WAS NEEDED DUE TO THE CARGO ALREADY BEING DISCHARGED.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Unknown
Issued 21 August 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 August 1995
Resolved 22 August 1995

Ownership record