Records from 2016 to 2020. Most recent: inspection, 2 September 2020.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 January 2019
Resolved
Conduct a satisfactory annual inspection for the renewal of the Certificate of Inspection. Vessel is overdue for the annual COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2019
Resolution: Deactivated COI at the request of the Owner.
Construction/Loadline › Hull › Transverse Frame
Issued 5 January 2018
Resolved
Crop and renew or make repairs to rotted frame under starboard side of fuel tank in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Construction/Loadline › Structures › Deck Plating
Issued 5 January 2018
Resolved
Make repairs to wood under starboard deck on outboard side of engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Construction/Loadline › Structures › Deck Plating
Issued 5 January 2018
Resolved
Repair damaged and decayed deck board in engine room near port side battery bank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Construction/Loadline › Structures › Superstructure
Issued 5 January 2018
Resolved
Crop damaged and decayed wood on starboard side window as identified and make available for inspection before making repairs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repair not necessary
Construction/Loadline › Hull › Side Shell
Issued 5 January 2018
Resolved
Crop decayed wood on port side freeing ports to good wood and make available for inspection prior to repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Engineering › Bilge Water Management System › Pump
Issued 5 January 2018
Resolved
Provide means to dewater space forward of collision bulkhead.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Hnad bilge pump on board
Lifesaving › Lifebuoys › Serviceable
Issued 5 January 2018
Resolved
Replace grabline on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 January 2018
Resolved
Provide enough lifejackets for all passengers and crew listed on COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 January 2018
Resolved
Store all lifejackets in readily available locations that are accessible by all passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Stowage locations previously used are appropriate per regulations
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2018
Resolved
Remove excessive dead end wire throughout engine room and rest of vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Dead end wires removed
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 January 2018
Resolved
Provide current FCC Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 January 2018
Resolved
Provide covers for all battery boxes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 January 2018
Resolved
Install metal fitting for generator fuel line thru-bulkhead penetration.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2018
Resolved
Remove and rewire electrical runs using "Romex" non-marine cable.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Removed/repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 January 2018
Resolved
Provide cover for rotating belt on generator to protect against hazard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 January 2018
Resolved
Replace worn and degraded retro-reflective tape on 8 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2018
Resolved
Repair spliced electrical cables that are spliced using wire nuts and replace with appropriate connections or new wire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: repaired/removed
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 January 2018
Resolved
Make all fire extinguishers readily available and easily accessible.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 5 January 2018
Resolved
Prove that all fire extinguishers are fully charged and inspected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 January 2018
Resolved
Prove proper shut down and engine override on MDE's.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 5 January 2018
Resolved
Prove operation of remote MDE shutdowns.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 January 2018
Resolved
Provide adequate fire extinguisher brackets to manufacturers specifications.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 13 December 2017
Resolved
Clean windings inside generator housing to remove all oil to satisfaction of attending CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 December 2017
Resolved
Ensure all wire/ cable runs are properly secured with appropriate metal clamps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 20 February 2018
Resolution: Repaired
Engineering › Fuel Oil Service System › Hose
Issued 13 December 2017
Resolved
Replace all cracked and worn fuel hoses on both MDE's, generator and coming from fuel tank in Laz. Replace to SAE J1942 standard for hoses and SAE J1475 for hose fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 20 February 2018
Resolution: Repaired
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 December 2017
Resolved
Provide covers for all electrical outlets.
Condition: Improper Installation
Due 10 January 2018
Resolved 20 February 2018
Resolution: Repaired
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 December 2017
Resolved
Repair handrails on upper deck to ensure sturdiness meets regulation standard and replace damaged wood as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 February 2018
Resolution: Repaired
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 December 2017
Resolved
Repair handrails on lower deck replacing damaged wood as necessary.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Electrical › Electrical Distribution System (service) › Switch
Issued 13 December 2017
Resolved
Re-fasten hanging electrical switch in aft side of port side of fuel tank space (lazarette).
Condition: Improper/Lack of Maintenance
Due 27 December 2017
Resolved 20 February 2018
Resolution: Removed
Construction/Loadline › Structures › Superstructure
Issued 13 December 2017
Resolved
Crop wasted and decayed wood on upper deck above railings on starboard side to good wood and make available for inspection prior to repairs.
Condition: Improper/Lack of Maintenance
Due 10 January 2018
Resolved 20 February 2018
Resolution: Repaired
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 13 December 2017
Resolved
Rewire lighting in kitchen space using permanent and appropriate gauge wiring.
Condition: Improper Installation
Due 27 December 2017
Resolved 30 April 2018
Resolution: Repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 December 2017
Resolved
Provide latch for oven in kitchen to prevent opening during vessel operation.
Condition: Improper Installation
Due 10 January 2018
Resolved 20 February 2018
Resolution: Repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 December 2017
Resolved
Provide guards on kitchen stove to prevent sliding of pots and pans while operating.
Condition: Improper Installation
Due 10 January 2018
Resolved 30 April 2018
Resolution: Installed rails
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 October 2017
Resolved
Prove proper operation of bilge high level alarms in all watertight compartments. No sail
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 October 2017
Resolved
Remove all oily water from bilge & make ready for inspection. No sail.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Engineering › Bilge Water Management System › Not Operational
Issued 26 October 2017
Resolved
Prove proper operation of bilge pumps in all watertight compartments. No sail.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 October 2017
Resolved
Complete annual coast guard exam. No sail.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Completed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 October 2017
Resolved
Install & prove operation of stern light & port side running light. Limited to day time operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 February 2018
Resolution: Repaired
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 26 October 2017
Resolved
Provide DAPI Management Information System (MIS) report
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 20 February 2018
Resolution: Repaired
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 October 2017
Resolved
Provide annual fire servicing certificate. No sail.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2018
Resolution: Repaired
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 26 October 2017
Resolved
Provide required amount of distress signals
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 20 February 2018
Resolution: Repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 October 2017
Resolved
Provide machinery guards for port & stbd shafts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 20 February 2018
Resolution: Repaired
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 October 2017
Resolved
Repair railings on upper deck as identified, prior to allowing passengers on upper deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 February 2018
Resolution: Repaired
Operations/Management › Vessel Activity › Underway
Issued 26 October 2017
Resolved
Complete satisfactory sea trial in presence of attending coast guard marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Completed
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 September 2016
Resolved
Provide PAX count embark and disembark on next several voyages
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 27 September 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 September 2016
Resolved
Repair embarkation rail and chain Port and Stbd side
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: rail course installed
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 September 2016
Resolved
Provide 2 PFDs
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2016
Resolved 27 September 2016
Resolution: Vessel acquired additional lifejackets
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 20 September 2016
Resolved
Provide maintenance record for lifesaving equipment
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: new log in place
Navigation › Piloting/Steering › Marine Charts
Issued 20 September 2016
Resolved
Provide chart for route
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: vessel acquired appropriate charts
Fire Fighting › Fire Bucket › Quantity
Issued 20 September 2016
Resolved
provide 2 fire buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: Acquired two additional fire buckets.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 September 2016
Resolved
lable stove shut off and install blank in open fuse
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: properly labled
Unknown
Issued 20 September 2016
Resolved
Lock overboard discharge for sewage
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 27 September 2016
Resolution: Locked
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 September 2016
Resolved
provide proof of supervisory traning and crew drug awarness training
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: EAP supervisory CD on board vessel
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 September 2016
Resolved
provide test strips
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: alcohol swabs on board
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2016
Resolved
repair anchor/mast light prior to operating at night
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 2 December 2016
Engineering › Fuel Oil Service System › Valve, Control
Issued 20 September 2016
Resolved
repair emer fuel shut off
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: repaired
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 August 2016
Resolved
Prove Existence of Valid Certificate of Documentation onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 August 2016
Resolved
Prove Operation of bilge high level alarms in every watertight compartment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 August 2016
Resolved
Prove Operation of remote fuel shut-off valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: Operation of valves demonstrated satisfactorily for [name withheld]. (See MISLE Act. No. 6002697)
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 August 2016
Resolved
Make aft Bulkhead of Crew Quarters compartment watertight in way of bilge suction penetration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 25 August 2016
Resolution: Due to vessel size (<65'), passenger count (<50), and route (protected), neither watertight subdivision nor a collision bulkhead is required and the bulkhead in question may be non-watertight.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 August 2016
Resolved
Install Fire extinguisher brackets, to be rigidly connected to vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 August 2016
Resolved
Complete annual Coast Guard inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: Inspection for reissuance of COI satisfactorily conducted by [name withheld]. (See MISLE Act. No. 6002697)
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 August 2016
Resolved
Provide 13 serviceable lifejackets on board in addtion to 43 found onboard. Reduce total persons onboard to 43.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 September 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 25 August 2016
Resolved
Remove all water and oil from bilges and make available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 20 September 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 August 2016
Resolved
Prove operation of Navigation lights. Restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2016
Resolved
Remove all dead end wires in bridge console, engine room and sitting room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 20 September 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 August 2016
Resolved
Post life jacket placard for every model of lifejacket onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: placard installed
Documentation › Logs/Records › Logbook (official)
Issued 25 August 2016
Resolved
Log crew training and drills for man overboard and firefighting.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 16 November 2016
Resolution: new log in place
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 July 2016
Resolved
Complete satisfactory Annual Inspection prior to carrying passengers for hire.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 September 2016
Resolution: Inspection for reissuance of COI satisfactorily conducted by [name withheld]. (See MISLE Act. No. 6002697)