Records from 1990 to 2026. Most recent: inspection, 31 July 2026.
Inspection history · 67
31 July 2026
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8451574
26 January 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8295487
21 January 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8288455
25 May 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8172606
30 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8126691
25 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7853881
17 January 2024
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7850014
17 October 2023
In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7810727
29 June 2023
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7726703
29 June 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7784472
12 April 2023
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7667046
8 March 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7636727
3 October 2022
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7570919
30 September 2022
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7606257
22 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7563176
24 March 2022
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7417732
12 January 2022
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7379581
28 October 2021
Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7341593
14 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7255734
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108385
6 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6949314
1 May 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6946667
10 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6659327
24 May 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6421794
22 May 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6420280
3 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6331996
15 February 2017
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6088445
18 April 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5856853
28 March 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5842726
21 December 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5786418
18 December 2015
Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5788401
24 January 2012
COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4243516
5 January 2012
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4218347
3 November 2008
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3356432
19 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3118397
9 November 2007
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3095697
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806461
20 March 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2605731
12 January 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2565729
14 January 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2275176
1 November 2004
Hull Examination · Re-Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2232541
10 November 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1945057
29 September 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1916623
12 November 2002
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1704090
21 February 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1493603
1 October 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 60335
23 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443125
17 November 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411998
20 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 168806
23 November 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453530
20 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424489
25 November 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380698
6 June 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 124579
26 February 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760482
23 February 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196338
19 December 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432985
13 December 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426984
14 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 661593
13 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 34008
2 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459833
11 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 125779
17 December 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423735
17 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 534985
17 January 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1319351
12 July 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1001119
5 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236645
9 February 1990
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218233
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 July 2026
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Wastage present in upper side shell adjacent to No.2 Port Fuel Tank; which resulted in a diesel discharge during bunkering operations.
No.2 Port Fuel Tank shall remain locked out and empty IAW vessel's mitigation plan until permanent repairs can be made. Master shall acknowledge status of tank No.2 Port Fuel Tank in rough log during all bunkering operations until permanent repairs are made.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2026
Resolved 14 August 2026
Resolution: Vessel completed permanent repairs on the pin hole and surrounding material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2024
Resolved
Oil lines with non-metallic hose is permitted if it meets
SAE J-1942 requirements.
MDE numbers 1, 5, and 6 did not have approved hose for control pressure lines on reduction gear.
46 CFR 182.720(e)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2024
Resolved 25 January 2024
Resolution: Hoses replaced and tested.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 March 2023
Resolved
An internal structural examination conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water. During ISE for aluminum hull in conjunction with COI, MI found eleven (11) cracks and cracked welds and marked gout out cracks. Drill stop ends of cracks. Reweld cracks to the satisfaction of attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 21 March 2023
Resolution: MI attended and verivied repairs made.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 March 2023
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Second licensed boat operator does not have radio operators permit. Provide proof of operators permit within 30 days. 47 CFR 80.159
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 13 April 2023
Resolution: Received copy of mate's FCC radio operator permit.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 March 2023
Resolved
The owner, charterer, managing operator or master must keep a correct list of names of all persons that embark on and disembark from the vessel. Vessel had passenger count sheets but not passenger names ashore. Vessel rep held training for both captains to submit names on trip report prior to getting underway.
Action required: 10 - Deficiency Rectified
Due 8 March 2023
Resolved 8 March 2023
Resolution: Training was held by vessel rep to the licensed officers onboard and issue corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 March 2023
Resolved
An internal structural examination conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water. During an internal structural exam, found approx. five (5) pits ranging from .150 to .175 deep located port main deck void at junction of chine and bottom plate. Crop and renew at next drydock (scheduled for March 2024) to the satisfaction of attending CG marine inspector.
Action required: 705 - Other - as specified
Due 31 March 2024
Resolved 17 January 2024
Resolution: Attending MI verified area had been cropped and renewd. Dye-pen had been conducted by a previous damage survey from marine casualty but not updated. Area was sound and no issues were noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 October 2022
Resolved
Repairs to machinery must not be made without the approval of the OCMI. Vessel suffered engine room fire on #3 MDE. Cut/replace softpatch over #3 MDE. NDT with dye pen on welds over lap joints. 46 CFR 176.700 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2022
Resolution: Softpatch was replaced and pressure tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2022
Resolved
Repairs to machinery must not be made without the approval of the OCMI. Vessel suffered engine room fire on #3 MDE. Renew #3 MDE. 46 CFR 176.700(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2022
Resolution: #3 MDE was replaced and tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2022
Resolved
Repairs to machinery must not be made without the approval of the OCMI. Vessel suffered engine room fire on #3 MDE. Renew melted/damaged wiring as identified by Marine Inspector and 3rd party electrician. 46 CFR 176.700(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2022
Resolution: Wiring harnesses were replaced and tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2022
Resolved
Repairs to machinery must not be made without the approval of the OCMI. Vessel suffered engine room fire on #3 MDE. Renew cooling pipe over #4 MDE. 46 CFR 176.700(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2022
Resolution: #4 MDE raw water cooling pipe was replaced and tested
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2022
Resolved
Repairs to machinery must not be made without the approval of the OCMI. Vessel suffered engine room fire on #3 MDE. Renew heat detector in overhead between #2 and #3 MDE. Test with heat gun for proper operation. 46 CFR 176.700(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2022
Resolution: Heat detectores were replaced and tested
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 October 2022
Resolved
Repairs to machinery must not be made without the approval of the OCMI. Vessel suffered engine room fire on #3 MDE. Oily in engine room bilges due to disassembly of #3 MDE. Clean bilges and dispose of all oily water. 46 CFR 176.700(a)
Action required: 10 - Deficiency Rectified
Resolved 5 October 2022
Resolution: all bilges have been pumped and cleaned
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 April 2019
Resolved
VSL IS NOT UPDATING CHARTS IAW LOCAL TO MARINERS. LAST UPDATE WAS 20FEB18.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 April 2019
Resolved 10 April 2019
Resolution: VSL OBTAINED NEW CHARTS DURING THE INSPECTION
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 April 2019
Resolved
FIRE MAIN HAS A LEAK IN THE PIPE THAT PREVENTS THE PRESSURE FROM MEETING THE REQUIRED 60PSI.
OLD T REF: 181.10-1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 10 April 2019
Resolution: Leak on pipe was repaired and fire main is now operational
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2017
Resolved
Provide guard protection from all angles to main diesels.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Installed adequate guards over rotating machinery on all six engines.
Engineering › Pressure Vessel › Shell Plate
Issued 15 February 2017
Resolved
Provide access to properly internally inspect both air receivers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Internally inspected both air receivers.
Stability › Watertight Integrity › General
Issued 21 December 2015
Resolved
vessel still had Pending NDT from Hull/ISE Required vessel to Prove sat Dye penetrant testing on engine room prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2015
Resolution: Cleared by CWO hemminger witnessing Dye pen.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 21 December 2015
Resolved
Rudder angel indicators were not matching each other or the positions of the rudder posts in the steering compartment. required vessel rep to prove sat operation of steering gear prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2015
Resolution: vessel provided third party service report clearing the issue.
Construction/Loadline › Penetrations › Gasket
Issued 21 December 2015
Resolved
bulkhead penetrations in between the passenger void and cofferdam were not watertight. required vessel rep to prove watertight integrity of the bulkhead prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2015
Resolution: Cleared deficiency via pictures and lable of material used.
Documentation › Certificates/Documents › FCC SSL
Issued 21 December 2015
Resolved
Vessel had the wrong name on ships station liscence required vessel rep to provide station liscence with the correct name.
Due 28 December 2015
Resolved 23 December 2015
Resolution: cleared via copy of new FCC station liscence
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 December 2015
Resolved
exhaust manifold was in the process of being repaired. required vessel rep to prove satisfactory repair of the exhaust leak
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2015
Resolution: cleared via picture and shipyard service report.
Engineering › Lubricating Oil Service System › Hose
Issued 21 December 2015
Resolved
discovered several hoses without requried double hose clamps, discovered one raw water hose close to bursting, and discovered one location without a required SAE J 1932 hose on a pressurized hydraulic line.
Due 28 December 2015
Resolved 23 December 2015
Resolution: cleared via reciept for new hoses, pictures of approved sae j1942 fittings, installations of the new hoses and double hose clamps.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 December 2015
Resolved
First aid kit had expired burn cream, asprin, and smellign salts. required vessel rep to provide satisfactory first aid kit.
Due 28 December 2015
Resolved 23 December 2015
Resolution: vessel rep provided picutres of satisfactory contentes within expiration dates.
Engineering › Freshwater System (cylinder head cooling) › Sensor
Issued 21 December 2015
Resolved
Jacket water temp gauge on #3 main did not work, required vessel rep to provided satisfactory J/W gauge.
Due 28 December 2015
Resolved 23 December 2015
Resolution: Vessel rep cleared deficiency via reciept for new gauge.
Documentation › Markings/Placards › Garbage Placard
Issued 21 December 2015
Resolved
vessel had the old marpol placcard, required vessel rep to provide current marpol placcard.
Due 28 December 2015
Resolved 23 December 2015
Resolution: vessel rep provide picture of correct marpol placcard.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 21 December 2015
Resolved
vessel had no emergency lighting in the aft steering compartment. requried vessel rep to provide sufficnet emergency lighting.
Due 28 December 2015
Resolved 23 December 2015
Resolution: vessel rep provided pictures of satisfactorily installed and operating emergency light.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 9 November 2007
Resolved
Battery for Emergency Lighting was Dead
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2007
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 9 November 2007
Resolved
Ampmeter needs to be repaired on battery charger
Due 9 December 2007
Resolved 13 November 2008
Resolution: repaired
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 9 November 2007
Resolved
Sewage Pump Did not work
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 November 2007
Resolved
Install Double Hose Clamps on all Sea water non-metallic Piping
Due 9 December 2007
Resolved 9 December 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 November 2007
Resolved
Replace Potable water heater relief valve
Due 9 December 2007
Resolved 13 November 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 9 November 2007
Resolved
Install 3/4 full visual device
Due 9 December 2007
Resolved 13 November 2008
Resolution: installed
Engineering › Fuel Oil Service System › Piping
Issued 9 November 2007
Resolved
Replace all F/O Return compression type fittings on return lines with flare type fittings on copper lines
Due 9 December 2007
Resolved 13 November 2008
Resolution: replaced
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 9 November 2007
Resolved
Provide two 15lb dry chem fire extinguishers for carriage of portable tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2007
Resolved 13 November 2008
Resolution: installed
Fire Fighting › Fire Main
Issued 12 November 2002
Resolved
Renew section of firemain containing multiple holes. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2002
Resolved 14 November 2002
Lifesaving › Embarkation Appliances/Stations
Issued 12 November 2002
Resolved
Properly stencil rescue platform zones. LEGACY COMPONENT DESC: Stenciling
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Lifesaving › Lifebuoys
Issued 12 November 2002
Resolved
Restencil life rings. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Lifesaving › Buoyant Apparatus
Issued 12 November 2002
Resolved
Restencil maximum capacity on lifefloats. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Lifesaving › Buoyant Apparatus
Issued 12 November 2002
Resolved
Install wood slats to seperate each lifefloat. LEGACY COMPONENT DESC: Lifefloat
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Electrical › Lighting (service)
Issued 12 November 2002
Resolved
Provide light bulb covers for stateroom and gally stove light fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Navigation › Piloting/Steering
Issued 12 November 2002
Resolved
Provide Local Notice to Mariners. LEGACY COMPONENT DESC: Local Notices to Mariners
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2002
Resolved 14 November 2002
Operations/Management › Cargo Transfer/Lightering
Issued 12 November 2002
Resolved
Provide proof of testing or renew fuel transfer hoses prior to operation of same. LEGACY COMPONENT DESC: Fuel Hoses
Action required: 703 - Prior to bunkering operations
Due 12 December 2002
Resolved 14 November 2002
Electrical › Electrical Distribution System (service)
Issued 12 November 2002
Resolved
Remove bare, dead-end wires for gally stereo. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 November 2002
Resolved
Renew engine room eyewash bottle. LEGACY COMPONENT DESC: Eyewash Station
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Engineering › Lubricating Oil Storage/Transfer System
Issued 12 November 2002
Resolved
Provide flame screen for lube oil tank. LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Electrical › Electrical Distribution System (service)
Issued 12 November 2002
Resolved
Provide blank for #2 engine room panel. LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Engineering › Bilge Water Management System
Issued 12 November 2002
Resolved
Properly label bilge manifold valves. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 14 November 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 November 2002
Resolved
Replace port main diesel engine tachometer. LEGACY COMPONENT DESC: Indicators
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 6 December 2002
Resolution: BLACKED OUT GAUGE WITH A MARKER.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 November 2002
Resolved
Provide deck railing or lifeline for the after portion of the main deck. LEGACY COMPONENT DESC: Deck Rail
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2002
Resolved 14 November 2002