MAURY USCG vessel records Sign in
← All vessels

HALKI

HALKI is a 1989 tank ship. The Coast Guard has recorded 41 inspections since 1990, most recently in July 2009, along with 11 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1990 to 2009. Most recent: inspection, 3 July 2009.

Built
1989
Last inspected
3 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8618918 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
343487
Flag
GREECE
—
Maury page id
psix-343487

Inspections, by type

…with no type recorded21
Years with a record 18 calendar years (1990–2009)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27793 - Convention (Subpart B), Gross Ton
13451 - Convention (Subpart B), Net Ton
56088 - Displacement, Ton
46538 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 41

3 July 2009 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3522086
28 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3401705
10 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391726
21 June 2008 ISPS II Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3233801
12 March 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2886147
7 March 2007 MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2883333
7 February 2007 Random ISPS/MTSA-No PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2868349
21 October 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2804975
26 June 2006 COC-TVE Renew · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2693995
27 February 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2592885
16 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2586945
29 September 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2504145
15 August 2005 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2465695
5 December 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2253669
6 June 2004 MTSA/ISPS Verification · Certificate of Compliance
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2090282
13 December 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1963820
3 November 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1951270
12 January 2003 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1729435
9 January 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1728802
2 January 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1474712
13 September 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 282168
13 September 2000 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1054598
18 July 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280220
7 September 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 432403
1 March 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 471143
20 September 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 420465
1 August 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 418917
1 August 1998 Tank Vessel Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1131713
10 July 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 405489
10 July 1997 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114686
8 April 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 475241
20 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375425
31 January 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 104397
31 January 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 535234
30 January 1994 Tank Vessel Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1447317
10 December 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142010
10 March 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 487708
29 August 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952006
23 August 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243608
28 January 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 335052
28 January 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929047

Deficiency record · 11

Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 7 March 2007 Resolved
IGS scrubber cooling water piping is soft patched (fiberglass patch). Repair to original. To satisfaction of class surveyor. Provide copy of class report to USCG by due date.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2007
Resolution: Received written report from vessel''s Classification society, Lloyd''s Register, attesting to repairs being completed and vessel is fit for intended route and service.
Engineering › Freshwater System (cylinder head cooling) › Fitting
Issued 7 March 2007 Resolved
M/E heat exchanger oil inlet piping is leaking excessively from coupling gasket. By vessels records, this appears to of been noted in vessels PMS and reported to DPA on 3/2006 and no repair has been conducted?
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2007
Resolution: Received written report from vessel''s Classification society, Lloyd''s Register, attesting to repairs being completed and vessel is fit for intended route and service.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 17 August 2005 Resolved
Pilot motor for steering gear inoperable. Repair prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 August 2005
Resolution: Motor rewound prior to departure.
Fire Fighting › Structural Fire Protection - General
Issued 12 January 2003 Resolved
Multiple fire doors and closures in the deckhouse found tied open or could not be closed would not latch. Repair to satisfaction of class. Provide class report to USCG. Vessel to drydock MAR2003.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 March 2003
Resolved 27 March 2003
Resolution: DOORS EXAMINED AND TESTED BY CLASS, FOUND TO SATISFACTORY.
Electrical › Electric Generation Source (emergency)
Issued 12 January 2003 Resolved
Emergency generator would not consistantly provide electrical power without manual intervention. Repair to satisfaction of class. Provide class report to USCG. Until repaired the vessel must man the emergency generator space with a qualified engineer while transiting in US waters.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 March 2003
Resolved 27 March 2003
Resolution: EMERGENCY GENERATOR WAS EXAMINED AND TESTED BY CLASS, FOUND TO BE SATISFACTORY.
Deck/Cargo
Issued 13 September 2000 Resolved
Provide stud at the top of the vapor recovery connection flange (at the top) in accordance with 46 CFR 39.20-1(e) to be completed by cargo operation that require vapor recovery or next dry dock.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Construction/Loadline
Issued 10 July 1997 Resolved
MISSING WELDED LOADLINE ON STARBOARD SIDE. ICLL
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Navigation
Issued 10 July 1997 Resolved
VESSEL DOES NOT HAVE AUTO PILOT ALARM.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Navigation
Issued 20 February 1995 Resolved
REPAIR AND PROVE PROPER OPERATION OF LOW LEVEL HYDRAULIC FLUID AND LOSS OF POWER (NO VOLT) AUDIBLE AND VISUAL ALARMS AT ENGINE CONTROL ROOM AND ON BRIDGE, (IAW SOLAS REG. 29.5.2 AND REG. 29, 12.2) TO SATISFACTION OF FLAG_x001C_ ADMINISTRATION.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Navigation
Issued 10 December 1992 Resolved
PRIOR TO LEAVING NEW YORK PROVIDE [name withheld] WITH DOCUMENTATION FROM CLASS SOCIETY PROVING PROPER OPERATION AND REPAIRS OF GYROCOMPASS AND REPEATERS.
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Fire Fighting
Issued 23 August 1991 Resolved
PROVIDE EVIDENCE OF ANNUAL FOAM ANALYSIS AT NEXT ENTRY TO U.S. PORT.
Condition: Unknown
Due 18 November 1991
Resolved 18 November 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.