AMERICAN STAR

AMERICAN STAR is a 1990 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1990, most recently in April 2026, along with 129 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 1990 to 2026. Most recent: inspection, 20 April 2026.

Built
1990
Last inspected
20 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN6115
343641
Flag
UNITED STATES
368296120
Maury page id
psix-343641

Inspections, by type

…with no type recorded5
Years with a record 33 calendar years (1990–2026)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.6 ft × 24.0 ft × 9.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)80.6 ft × 24.0 ft × 9.5 ft
ITC tonnagegross 132 / net 52
BuilderEQUITABLE SHIPYARDS INC · NEW ORLEANS, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCAPE MAY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 11 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it132 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
52 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6115MMSI 368296120 · active · compulsorily equipped · granted 10 February 2023, expires 10 February 2033
WDG6001MMSI 367552480 · expired · compulsorily equipped · granted 3 November 2012, cancelled 7 January 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

20 April 2026 Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8352599
23 February 2026 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8313707
8 April 2025 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8107932
6 June 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7927066
31 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7858665
2 August 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7758782
9 May 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7684654
7 February 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7633231
27 June 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7488435
23 February 2022 Internal Structural Exam · Deficiency Check · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7400083
5 April 2021 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7169223
14 December 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7113784
7 April 2020 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6936577
9 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6922857
10 February 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6906442
30 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6698507
1 May 2018 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6397710
27 February 2018 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6362317
18 May 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6144949
14 March 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5833365
20 January 2016 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5800677
24 June 2014 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4938743
17 March 2010 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3698416
16 February 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3681188
17 April 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3457817
31 March 2008 Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3176317
20 March 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3170571
16 April 2007 Administrative Inspection · Annual Inspection · Internal Structural Exam · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2985969
30 March 2007 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2898568
6 April 2006 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2622242
9 February 2006 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2585954
30 January 2006 Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2576107
17 June 2005 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2466142
5 April 2005 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2327085
22 April 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2060075
17 March 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2027633
15 April 2003 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1777159
18 April 2002 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1696319
1 November 2001 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1384914
11 May 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1389529
21 March 2000 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1379108
22 November 1999 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1365510
7 October 1999 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 816135
14 April 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1124066
6 October 1998 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1449120
21 April 1998 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 790266
22 November 1997 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1124312
7 October 1997 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1418251
14 April 1997 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1368157
15 April 1996 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1371366
12 October 1995 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1189434
29 September 1995 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1455287
21 September 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1185796
19 June 1995 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 878522
2 May 1995 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 868288
21 April 1995 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 859757
30 September 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 871273
24 February 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 856463
30 September 1993 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1448469
16 July 1993 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1157221
27 June 1993 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 161205
27 April 1993 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1431219
5 May 1992 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 954937
29 April 1991 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 922612
15 August 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 930498
1 August 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215107
18 May 1990 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921684

Deficiency record · 129

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2026 Resolved
A vessel that has a power driven fire pump must have Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, (46 CFR 182.710) of this chapter. A hole was found in the fire main in the lazarette serving the aft hydrants. Repair/replace and test to proper pressure the damaged section of fire main. 46 CFR 181.310(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2026
Resolved 8 May 2026
Resolution: Firemain pipe was repaired and tested to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2026 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, each hose must (1) be lined commercial fire hose that conforms to UL 19;(2) be 150 feet in length & 1.5 inches in diameter; and(3) have fittings that comply with NFPA 1963 (e.g., brass). One length of hose at the aft station was holed. Remove damaged hose & replace w/ new hose. (Vsl has sufficient add'l length of hose from 3rd fire station to meet minimal requirements in interim).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 14 May 2026
Resolution: Rec'd photos of new compliant fire hose in place of condemned hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2026 Resolved
A vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gal per minute at a pressure of not less than 60 psi at the pump outlet. The outlet must be fitted with a pressure gauge. The gauge was broken. Repair/replace outlet gauge.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2026
Resolved 8 May 2026
Resolution: Gauge was replaced and pump tested to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 February 2026 Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel has missed their drydock deadline of 28FEB2026. Vessel is restricted from carrying passengers until drydock credit is given. 46 CFR 176.100(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2026
Resolution: Credit dry dock completed 16APR2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 April 2025 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering gear ram in lazarette was missing a nut and unsecured on the starboard side. 46 CFR 182.30 Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2025
Resolution: Two nuts were affixed to port and starboard side of steering gear.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2025 Resolved
The intent of this part is to ensure that each vessel is provided with safe readily available and sufficient firefighting equipment. The start button on the fire pump remote start stop switch at the aft and port side fire stations must be continuously held for the fire pump to run. 46 CFR 181.01-05 Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 6 May 2025
Resolution: Marine electrician rewired switches. Verified operation. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 April 2025 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The coolant hose on the port side generator was chaffed and severely deteriorated. 46 CFR 182.10 Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 16 April 2025
Resolution: Verified new hose installed on running generator.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2025 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. The rescue platform has too much play when deployed for rescue operations and recovery of man overboard. 46 CFR 176.808(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 16 April 2025
Resolution: Added chain clips to platform to be connected to vessels bulwark.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 April 2025 Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installation. The MMSI number on the VHF DSC did not match the EPRIP or FCC station license MMSI. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 16 April 2025
Resolution: Vessel installed new VHF radio with proper MMSI number.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessels charts were outdated and did not have chart for all intended routes. 46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 16 April 2025
Resolution: Verified owner bought up to date chart.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Vessel had two outlet boxes beneath the operating station that were not mounted or secure. 46 CFR 183.01-15 Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 21 April 2025
Resolution: Outlets were mounted to deck beneath the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Vessel had new life jackets different from the donning instructions already posted. Post life jacket placard for new life jackets. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 16 April 2025
Resolution: Owner posted proper lifejacket placard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 April 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights mus be located at the operating station. The vessel did not have a portable light at the operating station. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 21 April 2025
Resolution: Portable flashlight was mounted at operating station.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 April 2025 Resolved
Vessel has lockable spaces but has no master key control system. 46 USC 3106
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 21 April 2025
Resolution: Vessel has master key control log with list of all persons with access to master key.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2024 Resolved
The minimum capacity of a fire pump must be 50 gallons per minute at a pressure not less than 60 PSI. The pump shall be outfitted with a pressure gauge. Pressure gauge was only reading 20PSI. Adjust or replace gauge. 46CFR 181.10 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 1 July 2024
Resolution: Verified fire hose could reach adeqaute pressure.Cleared def.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 May 2023 Resolved
Each buoyant apparatus must be fitted with a lifeline, pendants, a painter, and a light. Vessel was unable to determine expiration dates of batteries for 6 buoyant apparatus's. Replace batteries or provide expiration dates from manufacturer to the satisfaction of a CG marine inspector. 46 CFR 180.175(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 16 May 2023
Resolution: Identified expiration dates from manufacturer. All lights are within expiration dates and operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2022 Resolved
REMOVE THE (2) TWO POWER STRIPS CHAINED TOGETHER UNDER THE HELM, RELOCATING THE PLUGGED IN ITEMS TO A DEDICATED OUTLET AND DIRECTLY HARD-WIRE THE BOAT CABLE POWERING THE CHILLER UNIT IN THE MAIN SALON INTO A DEDICATED CIRCUIT.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 28 July 2022
Resolution: Cleared via emailed photos (uploaded as PDF)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2022 Resolved
REPLACE THE LIGHT, GLOBE, AND CAGE FOR THE STARBOARD SIDE OVERHEAD LIGHT IN THE LAZARETTE.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 June 2022
Resolved 28 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 June 2022 Resolved
THE NUT SECURING THE STARBOARD STEERING QUADRANT WAS MISSING. REPLACE THE NUT TO ENSURE THE RAM IS SECURELY ATTACHED TO THE STEERING.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 June 2022
Resolved 27 June 2022
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 June 2022 Resolved
THE PORT SIDE REMOTE PULL FOR FUEL SHUT OFF DOES NOT OPERATE SMOOTHLY, MAKING IT DIFFICULT TO FULLY SHUT OFF FUEL SUPPLY. REPAIR REMOTE PULL SO THAT IT OPERATES SMOOTHLY AND THE OPERATOR CAN POSITIVELY CONFIRM FULL CLOSURE OF THE FUEL VALVE.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 28 July 2022
Resolution: Cleared via emailed video for Acty 7488435
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 April 2021 Resolved
Liferafts are arranged so that when they float free, they will get caught in mast. Reroute life float painters to avoid being snagged through the mast support as currently arranged.46 CFR 180.130(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2021
Resolution: Master provides photos of properly rigged life floats.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
Outlet, next to water tank between fuel tanks, hot and neutral are reversed. Reverse wires to rectify. (OLD "T") 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photo showing plugged in outlet tool showing "Correct" lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
Lazarette space, forward bulkhead, starboard side, hot an neutral are reversed. Reverse wires to rectify. (OLD "T") 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photo showing plugged in outlet tool showing "Correct" lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
Engine room, forward bulkhead, port side, outlet below battery charger, open ground is shown. Locate and repair open ground. (OLD "T") 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photo showing plugged in outlet tool showing "Correct" lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
Engine room, forward bulkhead, port side, next to battery charger is a temporary splice of two conductors Make connection in a permanent enclosure. (OLD "T") 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photo of proper enclosure.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 5 April 2021 Resolved
Black "primary" VHF with DSC capability needs to be on it's own dedicated electrical circuit in addition to being connected with a 3 hour battery back up. Currently the white "back up" VHF (without DSC capability) is connected to the same electrical circuit but the VHF without DSC capability is currently wired to the battery backup. Re-arrange so that VHF with DSC capability (black "primary" one) has it's own dedicated circuit that connects to the 3 hour battery back up. VHF that does not have DSC capability should have it's own dedicated circuit as well. (OLD "T")46 CFR 183.05-25(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photos showing that radios were placed on their own dedicated circuit that was wired to battery back ups.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 April 2021 Resolved
Replace PVC plug cap on fire main piping in collision bulkhead space with metallic threaded plug. (OLD "T")46 CFR 181.15-5 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photo of stainless steel cap installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2021 Resolved
Port M/E 120 volt oil heater plug is leaking oil. Remove and reseal heater plug. (OLD "T")46 CFR 176.25-10(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 4 May 2021
Resolution: Master provided photo of block heater that was re-sealed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2021 Resolved
Submit electrical plan for microwave (900 W)/ hotdog roller (900W)/ dual toaster oven (1800 W) power arrangement by upcoming drydock in March 2022. Current arrangement using outlet multiplier on starboard side outlet has caused melting and light damage to begin at the outlet and prongs. Either reduce the potential electrical loads at damaged outlet with new, remove outlet multiplier and directly plug in microwave/ hot dog roller into the new outlet and relocate hand held radio chargers to separate circuit. Do not plug both toaster ovens into the same circuit as this overloads the circuit, remove or relocate one of the toaster ovens to another circuit. Code 705, by next drydock. 46 CFR 183.220(b)
Action required: 705 - Other - as specified
Resolved 4 May 2021
Resolution: Master provided email that stated that all the outlets in the cooking area were on their own circuits. Master provided video showing the high output devices distributed evenly between outlets
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 5 April 2021 Resolved
Engine room, midship, outboard of port M/E, re-weld broken deck vertical support to bottom support. 705, by next drydock. (OLD "T")46 CFR 176.25-1(a)
Action required: 705 - Other - as specified
Resolved 24 March 2022
Resolution: Reattended vessel. Vertical support to bottom support rewelded satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 April 2021 Resolved
Repair forward starboard hydraulic ram steering assist mount to starboard rudder tiller. Bolt hole has worn considerably and there is a 1/2"+ gap causing the bolt connections to slam back and forth when actuated by helm controls. Vessel has two additional hydraulic assist rams to assist, so issue can be addressed at next drydock. Code 705, by next drydock. (OLD "T")46 CFR 182.30-1
Action required: 705 - Other - as specified
Resolved 19 April 2022
Resolution: Viewed satisfactory repair of bolt hole with new bushing.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 9 March 2020 Resolved
Repair 3 pits on sewage tank with approved epoxy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2020
Resolved 11 March 2020
Resolution: Vessel wire wheeled the affected area and applied expoy.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 9 March 2020 Resolved
Replace ball valve on sewage tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2020
Resolved 11 March 2020
Resolution: Vessel replaced the ball valve on the sewage line with a new one.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2020 Resolved
Make weld continuous around port side strut where it meets the hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2020
Resolved 11 March 2020
Resolution: Shipyard welded the strut so it's now continuous where it meets the hull.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 February 2020 Resolved
Vessel has passed the date for required drydocking as per the certificate of inspection. Make vessel available for drydock inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2020
Resolution: the vessel has since conducted and been given credit for DD on 11MAR2020 (#6922857)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2019 Resolved
Replace identified fire hose. 46 CFR 181.15-10(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 May 2019 Resolved
Replace pressure gauge on fire pump. 46 CFR 181.10-1(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Received email showing a new gauge was installed on their fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 May 2019 Resolved
Replace grab line on lifering. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2019
Resolution: Received email showing vessel purchased a new life ring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
Remove dead end wiring in the engine room, located port side forward of the port engine. 46 CFR 183.200(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Received email showing vessel removed the dead end wiring in the engine room, located port side forward of the port engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
Remove electrical splice on the starboard engine. 46 CFR 183.340(m)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Received email showing vessel removed spliced wire.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Prove completion of DAPI supervisory training. 46 CFR 16.401(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Received email attesting that Captains attended DAPI training.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
Maintain DAPI test results for 1 year. 46 CFR 16.206(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Vessel stated they will retain DAPI test results for 1 year.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 May 2019 Resolved
Provide updated charts for areas where operations are conducted. 46 CFR 184.420(a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Vessel purchased new charts.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2019 Resolved
Replace fire pump electrical box. 46 CFR 183.210(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 July 2019
Resolution: Received email showing vessel replaced fire pump electrical box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019 Resolved
Remove string from stbd fuel shutoff. 46 CFR 182.20-40(b)(3)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 May 2019 Resolved
Replace navigation batteries. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 May 2019
Engineering › Bilge Water Management System › Not Operational
Issued 1 May 2018 Resolved
No bilge suction in the first space aft of the forepeak. Prove proper operation of bilge suction from space prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2018
Resolution: Crew cleared clog in bilge line. MI witnessed satisfactory operation of bilge suction in space.
Lifesaving › Lifefloat › Paddle
Issued 1 May 2018 Resolved
For both port and stbd life floats, have paddles properly lashed to their respective life floats.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Verified paddles for both life floats are lashed to their respective life floats.
Lifesaving › Lifefloat › Retroreflective Material
Issued 1 May 2018 Resolved
For the port lifefloat, replace deteriorated retro reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Retro for port life float replaced.
Lifesaving › Lifefloat › Painter
Issued 1 May 2018 Resolved
For stbd lifefloat, ensure proper connection to painter. Lifefloat is currently tied to the port lifefloat. Current configuration is not adequate. Attach individually to painter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Painter re-attached in an approved configuration.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 1 May 2018 Resolved
Ensure sewage discharge valve is locked to prevent tampering.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: lock installed to prevent tampering
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.3-Comprehensive Annual Inspections
Issued 1 May 2018 Resolved
Provide VGP plan for vessel including inspection procedures referenced in annual inspection sheet.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Verified presence of inspection procedures in VGP
Fire Fighting › Fire Pumps › Pressure
Issued 1 May 2018 Resolved
Install pressure gauge at discharge of fire pump
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: pressure gauge installed at discharge, near port side engine.
Construction/Loadline › Hull › Weld
Issued 1 May 2018 Resolved
Re-weld cracked welds as marked in fore peak and first space behind the fore peak.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Verified re-welded cracks in fore peak and 1st space aft of fore peak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2018 Resolved
Identified loose wire in run penetrating watertight bulkheads between 1st space aft of fore peak, 2nd space aft of forepeak, and engine room. Bundle wire and make pulkhead penetrations watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Penetrations sealed through all bulkheads the wire passes through.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 May 2018 Resolved
Cover missing for junction box in 2nd space aft of forepeak, near fresh water pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Cover placed on junction box.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 1 May 2018 Resolved
Provide adequate potection for fuel tank sight gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Plexiglass panel added to front of fuel tank sight guage.
Communications › Radio Communications › EPIRB
Issued 18 May 2017 Resolved
Provide EPIRB registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 25 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2017 Resolved
Permanently wire in freezers in compartment #2.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 25 May 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 14 March 2016 Resolved
DC02:Provide DAPI Crew List and prove program compliance.
Condition: Improper/Lack of Maintenance
Due 1 April 2016
Resolved 28 March 2016
Resolution: Company provided updated crew list, and proof of program compliance.
Lifesaving › Lifefloat › Markings
Issued 14 March 2016 Resolved
DC03:Clean/re-paint (IAW Jim-Bouy instructions) port life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Vessel repainted life float.
Communications › Audible Communications › SPD (Other)
Issued 14 March 2016 Resolved
DC04:Remove wire nuts on PA system wiring and replace with acceptable connector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Wire nuts on the PA system were removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016 Resolved
DC05:Remove plug connectors on bilge high level alarms and replace with acceptable connector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Plug connectors were replaced with permenant type.
Stability › Unintentional Flooding › General
Issued 14 March 2016 Resolved
DC06:Plug hole in aft side of E/R vent housing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Plugged hole, and welded shut.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016 Resolved
Remove dead end wires in E/R on aft bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Dead end wiring was removed.
Lifesaving › Lifebuoys › Serviceable
Issued 14 March 2016 Resolved
Repair/Replace first deck aft lifering(Tape, tears, line)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Vessel purchased new lifering.
Documentation › Logs/Records › Logbook (official)
Issued 14 March 2016 Resolved
DC09:Provide lifesaving inspection Logs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Vessel has started new life saving log.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 March 2016 Resolved
DC10:Conduct MOB drills.
Condition: Improper/Lack of Maintenance
Due 28 March 2016
Resolved 28 March 2016
Resolution: Drills were conducted at sea, all sat.
Documentation › Certificates/Documents › FCC SSL
Issued 24 June 2014 Resolved
[name withheld] must show proof of a marine radio operator's permit.
Action required: 705 - Other - as specified
Resolved 18 May 2017
Engineering › Fuel Oil Service System › Valve
Issued 24 June 2014 Resolved
Must re-label emergency fuel shut off valves.
Action required: 705 - Other - as specified
Resolved 9 September 2014
Resolution: Emergency fuel shut offs were re-labeled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 June 2014 Resolved
Must re-label upper deck PFD storage to 59 adult and 7 children.
Action required: 705 - Other - as specified
Resolved 9 September 2014
Resolution: PFD storage was re-labeled for the correct amount.
Construction/Loadline › Structures › Deck Plating
Issued 24 June 2014 Resolved
Make hole in deck on top of the lazarette watertight.
Action required: 705 - Other - as specified
Resolved 9 September 2014
Resolution: Closed up hole with a bolt and washers on both sides with sealant between the washers.
Stability › Watertight Integrity › General
Issued 24 June 2014 Resolved
Replace gasket in engine room quick acting watertight hatch.
Action required: 705 - Other - as specified
Resolved 9 September 2014
Resolution: Gasket was replaced on the hatch.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 June 2014 Resolved
Repalce missing light in lazarette.
Action required: 705 - Other - as specified
Resolved 9 September 2014
Resolution: Light was replaced in lazarette.
Construction/Loadline › Hull › Weld
Issued 16 February 2010 Resolved
Repair cracked weld in Lazarette to right of ladder (top).
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Weld repaired (gouged out & reweld)
Construction/Loadline › Structures › Superstructure
Issued 16 February 2010 Resolved
Crop & renew starboard awning support aft of pilothouse (13-15" vertical crack)
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: 3 foot aluminum stanchion cropped & renewed
Construction/Loadline › Structures › Superstructure
Issued 16 February 2010 Resolved
Repair cracked weld on port awning support aft of pilot house (top of support tube cracked all the way around).
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 17 March 2010
Resolution: Weld gouged out & re-welded
Construction/Loadline › Structures › Superstructure
Issued 15 April 2008 Resolved
Port side aft stanchion that supports port-aft corner of O1 deck had broken free from main deck at the weld. Required O/O to repair/replace aft port side stanchion.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 21 April 2008
Resolution: Stanchion rewelded to deck to satisfaction of attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 April 2008 Resolved
Dead-end wires present on port main. Required O/O to remove/secure dead end wires on port engine.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 21 April 2008
Resolution: Dead-end wires secured.
Construction/Loadline › Hull › Hull Plating
Issued 31 March 2008 Resolved
1) Repair localized corrosion on port side shaft log.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 15 April 2008
Resolution: Vessel replaced port side shaft log to the satisfaction of marine inspector. Photos of repair added to vessel file.
Stability › Watertight Integrity › General
Issued 31 March 2008 Resolved
Replace stbd side gooseneck vent sealing balls.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 21 April 2008
Resolution: Stbd side gooseneck vent sealing balls all replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2008 Resolved
Vessel Dry-dock / Internal structure exam past due date of 10 FEB 2008.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2008
Resolved 31 March 2008
Resolution: Vessel completed drydock and internal structural exam.
Electrical › Electrical Distribution System (service) › Cable
Issued 6 April 2006 Resolved
Provide metal wire supports every 24" for recently installed electrical cables in engine room.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 26 April 2006
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 April 2006 Resolved
Mark top-side of engine room escape hatches "EMERGENCY EXIT, KEEP CLEAR" with 2" high letters.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 26 April 2006
Construction/Loadline › Hull › Stiffener
Issued 9 February 2006 Resolved
Repair to original port & starboard fuel tank frame stiffeners in mid-ship void.
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 6 April 2006
Resolution: Frame stiffener fractures repaired.
Construction/Loadline › Hull › Bracket
Issued 9 February 2006 Resolved
Repair to original, cracked frame on port ENG mount frame.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 6 April 2006
Resolution: Port engine mount frame rewelded.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 February 2006 Resolved
Repair to original, 2 inch crack in weld on starboard eng exhaust doublers plate.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 6 April 2006
Resolution: Starboard eng exhaust doublers plate welds repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 February 2006 Resolved
Repair cracks on welds in starboard exhaust where exhaust penetrates aft engineering bulkhead.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 6 April 2006
Resolution: Starboard eng exhaust welds repaired.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 9 February 2006 Resolved
Cap out abandoned pump-out piping from MSD.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 6 April 2006
Resolution: MSD piping caped-out.
Construction/Loadline › Penetrations › Gasket
Issued 18 April 2005 Resolved
Tighten the Port and Starboard packing glands on the Port and Starboard shafts to reduce the excessive leaking.
Due 25 April 2005
Resolved 6 April 2006
Resolution: Inspected and found corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 April 2004 Resolved
Repair or replace 2 light ficture protective globes on the main deck forward, Port and Stdb side.
Due 22 May 2004
Resolved 24 May 2004
Resolution: light ficture protective globes renewed.
Fire Fighting › Fire Pumps › Arrangement
Issued 22 April 2004 Resolved
Provide a pressure gauge for the fire pump as per 46 CFR 181.10-1 (c) to the satisfaction of the cognizant OCMI.
Due 22 June 2004
Resolved 24 May 2004
Resolution: Pressure gauge added to the fire pump.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 April 2004 Resolved
Place reflective tape on one ring buoy, 2nd deck aft.
Due 22 May 2004
Resolved 24 May 2004
Resolution: Reflective tape renewed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 April 2004 Resolved
Repair/replace life line on one ring buoy, main deck aft.
Due 22 May 2004
Resolved 24 May 2004
Resolution: Life line on one ring buoy renewed.
Construction/Loadline › Penetrations › Gasket
Issued 22 April 2004 Resolved
Tighten the port rudder post to stop the excessive water leak.
Due 22 May 2004
Resolved 24 May 2004
Resolution: Excessive water leak in the port rudder post repaired.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 April 2003 Resolved
Remove all childrens PFD's from plastic packwges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2003
Resolved 15 April 2003
Lifesaving › Immersion Suits
Issued 15 April 2003 Resolved
Mark vessel name on immersion suit.
Due 17 April 2003
Resolved 15 April 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 April 2003 Resolved
Mark engine room escape "Emergency escpae, keep clear".
Due 25 April 2003
Resolved 21 April 2003
Resolution: [name withheld] sent E-mail and followed with phone call to tell me that this deficiency is corrected.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 April 2003 Resolved
Provide current Master's license on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2003
Resolved 21 April 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 11 May 2001 Resolved
Renew EPIRB registration.
Condition: Unknown
Due 21 May 2001
Resolved 12 December 2001
Construction/Loadline
Issued 11 May 2001 Resolved
Prove proper operation of E-room hi-water alarm.
Condition: Unknown
Due 21 May 2001
Resolved 12 December 2001
Construction/Loadline
Issued 11 May 2001 Resolved
Prove proper operation of installed bilge pump.
Condition: Unknown
Due 21 May 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 11 May 2001 Resolved
Mount hammer near emergency escape from E-room for opening hatch.
Condition: Unknown
Due 21 May 2001
Resolved 12 December 2001
Engineering
Issued 11 May 2001 Resolved
Wrap chafing around fuel hose under port Racor where chafing on deck plate.
Condition: Unknown
Due 21 May 2001
Resolved 12 December 2001
Engineering
Issued 6 October 1998 Resolved
REPAIR OR REPLACE EXHAUST MANIFOLD FROM FROM STBD MAIN ENGINE.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Accommodation/Occupational Safety
Issued 6 October 1998 Resolved
LABEL EMERGENCY ESCAPES IN ACCORDANCE WITH 46 CFR 185.606.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Lifesaving
Issued 6 October 1998 Resolved
REMOVE OR REPLACE THE 4 LIFE FLOATS.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Construction/Loadline
Issued 6 October 1998 Resolved
REPAIR OR REPLACE AND PROVE OPERATIONAL THE BILGE PIPING SYSTEM FROM THE FOREPEAK TO THE BILGE MANIFOLD.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Lifesaving
Issued 6 October 1998 Resolved
PROCURE AND INSTALL A 406 MHZ EPIRB PRIOR TO 11MAR99.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Lifesaving
Issued 6 October 1998 Resolved
CONDUCT UNDERWAY OPERATIONAL DRILLS PRIOR TO THE 1999 SEASON. (APRIL 99)
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Electrical
Issued 6 October 1998 Resolved
REPLACE FLEXIBLE NON-METALLIC HOSE COUPLING ON GENERATOR EXHAUST STBD SIDE.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Navigation
Issued 6 October 1998 Resolved
REPAIR STEERING PIVOT POINTS ON BOTH RAMS.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Fire Fighting
Issued 7 October 1997 Resolved
Service all portable fire extinguishers.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 7 October 1997 Resolved
Renew/replace six of eight deteriorated paddles for lifefloats.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Electrical
Issued 7 October 1997 Resolved
Procure/provide non-conductive mat for engineroom electrical switchboard.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Navigation
Issued 29 September 1995 Resolved
Replace the (2) outboard hydraulic hoses on the stbd side of the lazarette for the steering system and the missing hold down clamp
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
Weld the hole closed on the port side of 2nd watertight bulkhead adjacent to the hydraulic steering piping
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
Repack/make watertight the newly installed cables penetrating all watertight bulkheads
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 29 September 1995 Resolved
Repair/replace fractured stern tube on port shaft
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
Repair/replace support bracket adjacent to the ladder in the lazarette
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Navigation
Issued 29 September 1995 Resolved
Double nut or pin the linkage to the steering feedback unit
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Navigation
Issued 29 September 1995 Resolved
Provide stress relief for cable entering steering feedback unit for automatic pilot
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Lifesaving
Issued 21 April 1995 Resolved
MARK RING BUOYS WITH REFLECTIVE TAPE.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Electrical
Issued 21 April 1995 Resolved
PROVIDE PROPER LIGHT GUARD COVER FOR EXPOSED LIGHT IN FOWARD STORAGE AREA.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Accommodation/Occupational Safety
Issued 18 May 1990 Resolved
POST INSTRUCTIONS TO MSD
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Documentation
Issued 18 May 1990 Resolved
PROVIDE COPY OF LICENCES AS REQUIRED BY 46 CFR 185.10-1
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Documentation
Issued 18 May 1990 Resolved
POST STABILITY LETTER AS REQUIRED BY 46 CFR 185.12-1
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Fire Fighting
Issued 18 May 1990 Resolved
RELOCATE FIRE AXE TO PILOTHOUSE OR ADJACENT TO AS PER 46 CFR 185.35-1.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Documentation
Issued 18 May 1990 Resolved
PROVIDE COPY OF VESSEL DOCUMENTATION
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990

Casualty record · 1

17 June 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2466142
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

FJORDLAND (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.