MAURY USCG vessel records Sign in
← All vessels

CASABLANCA

CASABLANCA is a 1990 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1990, most recently in March 2026, along with 343 deficiencies, 1 operational control and 4 casualty investigations between 2007 and 2021.

Records from 1990 to 2026. Most recent: inspection, 25 March 2026.

Built
1990
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDR3383
343647
Flag
UNITED STATES
367674990, 368349750
Maury page id
psix-343647

Inspections, by type

…with no type recorded16
Years with a record 34 calendar years (1990–2026)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)75.0 ft × 28.0 ft × 9.0 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTH SEAS CATAMARAN · CAPE CORAL FL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portPORTLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3383MMSI 367674990 · active · compulsorily equipped · granted 25 July 2026, expires 25 July 2036
WDP3920MMSI 368349750 · active · compulsorily equipped · granted 23 January 2024, expires 23 January 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDI2126MMSI 367674990 · expired · compulsorily equipped · granted 28 May 2015, cancelled 5 July 2025
WCZ9371MMSI not assigned · expired · compulsorily equipped · granted 14 July 2000, cancelled 18 September 2010
WCR8914MMSI not assigned · expired · compulsorily equipped · granted 30 May 1995, cancelled 30 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NAUTILUS Passenger (Uninspected) · MISLE 168071 · 16 July 2022 · activity 7511733

Inspection history · 79

25 March 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8331662
30 May 2025 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8162139
30 May 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7926744
25 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7901718
15 September 2023 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7791992
20 August 2023 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7794651
20 August 2023 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7796054
31 May 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7701282
16 July 2022 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7511733
22 April 2022 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7435896
2 August 2021 Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7275035
31 July 2021 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7276063
11 June 2021 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7222509
2 June 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6966861
25 October 2019 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6830046
29 June 2019 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6732405
21 June 2019 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6721402
14 August 2018 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6511589
2 August 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6507505
19 May 2018 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6423430
4 May 2018 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6416373
16 August 2017 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6243781
18 July 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5952382
4 April 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5846869
21 October 2014 COI Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5023654
9 October 2014 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5002242
19 January 2012 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4227847
26 July 2011 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4094594
2 December 2009 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3643196
8 July 2008 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3260198
23 April 2008 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3190316
13 September 2007 In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3056963
2 September 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3049020
25 April 2007 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2915493
7 April 2006 Hull Examination · Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2618955
21 June 2005 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2397412
14 June 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2097730
27 October 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1936690
9 July 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1840822
29 August 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1668357
21 May 2002 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1618878
1 May 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1611539
4 October 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1074500
4 October 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1478433
4 June 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1065525
26 February 2001 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1059040
4 October 2000 Damage Survey · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1391384
21 June 2000 Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 818956
1 May 2000 Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1424889
25 October 1999 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 793056
10 May 1999 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1469266
22 May 1998 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 793795
4 November 1997 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1118572
3 October 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1108097
31 July 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1116893
12 May 1997 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1448908
29 June 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 74191
7 June 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 875122
21 May 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1083424
10 May 1996 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1457344
27 November 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 881567
26 September 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191776
26 July 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1185444
18 July 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 878408
24 August 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175059
20 July 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 864156
1 October 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1148103
20 July 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152679
9 September 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 950735
21 July 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 946039
22 October 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942307
23 September 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 936412
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937390
30 July 1991 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1246478
8 November 1990 Deficiency Check · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915641
3 October 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1242940
20 September 1990 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1241269
5 September 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897938
3 August 1990 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903047

Deficiency record · 343

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 May 2025 Resolved
Vessel missing 03 smoke flares.
Due 4 June 2025
Resolved 2 June 2025
Resolution: Flares provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 May 2025 Resolved
Rear doors in crews area on first deck do not latch or secure properly. Repair or replace as needed.
Due 2 June 2025
Resolved 2 June 2025
Resolution: Proper latches replaced on doors.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 May 2025 Resolved
Vessel Need emergency instructions posted at operating station.
Due 12 June 2025
Resolved 12 June 2025
Resolution: Emergency Instructions placed onbridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2025 Resolved
Life ring light need a non-corrosive clip at life ring.
Due 16 June 2025
Resolved 12 June 2025
Resolution: Clip provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2025 Resolved
Life ring light need a non-corrosive clip at life ring.
Due 13 June 2025
Resolved 12 June 2025
Resolution: Bracket provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2024 Resolved
Life ring needs new grab-lines and new stenciling
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2024
Resolved 18 June 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2024 Resolved
Fire extinguishing system was inspected and is operational as per tech. However, system active light was extinguished. Needs an electrician.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2024
Resolved 30 May 2025
Resolution: Alarm fixed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2023 Resolved
Repair port side fuel shut off. Cable parted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Cable repaired and tested.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 September 2023 Resolved
Repair/ replaceport side engine room ventilation closure (damper).
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Damper closure tested. works sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2023 Resolved
Repair replace main deck door (fire escape) so that it opens properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Door repaired and tested.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 September 2023 Resolved
Repair hole in stbd side hull in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Repairs completed and water tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 September 2023 Resolved
Tighten contact on stbd Fireboy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Contacts secure.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 October 2023
Resolved 30 May 2025
Resolution: License provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2023 Resolved
Provide FCC Safety Radio Certificate.
Due 15 October 2023
Resolved 30 May 2025
Resolution: Cert provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 September 2023 Resolved
Provide Coast Pilot, Light list and Tide Tables for Bridge.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Online pubs provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 September 2023 Resolved
Replace Emergency Broadcast Placard for Bridge.
Due 29 September 2023
Resolved 30 May 2025
Resolution: Placard provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2023 Resolved
Prove proper operation of Digital Selective Calling feature on VHF Radio.
Due 29 September 2023
Resolved 30 May 2025
Resolution: DSC tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 September 2023 Resolved
Repair Bilge Alarm light for stbd head.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Alarm light repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 September 2023 Resolved
Refresh “Casablanca” markings on life rings.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Markings replenished.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 15 September 2023 Resolved
Provide appropriate first aid kit.
Due 29 September 2023
Resolved 22 September 2023
Resolution: New first aid kit provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023 Resolved
All electrical splices need to be in appropriate electrical boxes.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Splices placed in proper junction boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 September 2023 Resolved
Provide bulbs or covers for all light bulb sockets,
Due 29 September 2023
Resolved 22 September 2023
Resolution: Proper bulbs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2023 Resolved
Tighten port battery terminals for generator.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Terminals tightened.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 September 2023 Resolved
Repair/ replace broken gauge on fire pump.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Gauge replaced and tested under pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2023 Resolved
Repair port engine room ground wire.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Ground wire reconnected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023 Resolved
Repair/ replace port main diesel engine exhaust pipe.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Pipe properly welded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 September 2023 Resolved
STBD HVAC room raw water valves need to be removed/ repaired/plugged.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Pipes capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023 Resolved
Unwrap stbd main engine exhaust for inspection.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Exhaust inspected. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2023 Resolved
Tighten up engine mounting bolts so they have proper security.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Longer hardware provided. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2023 Resolved
Repair replace flame screens in fuel tank vents. Will fix at drydock.
Due 29 September 2023
Resolved 30 May 2025
Resolution: Flame screens provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 September 2023 Resolved
Vessel missed it's Annual Certificate of Inspection window. Due date was 8/19/23.
Action required: 10 - Deficiency Rectified
Due 15 September 2023
Resolved 15 September 2023
Resolution: Annual inspection completed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 August 2021 Resolved
Received notification from vsl owner stating the CASABLANCA received damage from a grounding incident. Vessel is restricted from PAX carriage pending inspection of damage. Repairs, if required, will be made to the satisfaction of an attending CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2021
Resolved 1 September 2021
Resolution: Repairs complete. Sea trial conducted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 June 2021 Resolved
Current light list, tide table, and coast pilot not onboard during time of inspection. Ensure current nautical publications are onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: New publications acquired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Anti-strain clamp on junction box in port lazarette missing screw. Ensure anti-strain clamp is properly installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Installed Clamp
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 June 2021 Resolved
Could not provide FCC Safety Certificate and Bridge-to-Bridge certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 9 June 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Dead end wires found throughout the vessel. Remove all dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Electrician removed most dead-ended wires, however this will continue to be a work in progress.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Various electrical equipment/boxes missing covers. Ensure all electrical equipment/boxes have covers or guards to protect from shock.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Attended VSL. Verified SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2021 Resolved
Fire extinguishers required by COI missing from vessel. Ensure the vessel is equipped with proper amount of fire extinguishers as required by it's COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Extinguishers verified onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2021 Resolved
Life jackets are in the process of being replaced. Ensure the vessel is equipped with proper amount of lifejackets as required by it's COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Life jackets verified onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 June 2021 Resolved
Emergency exits on main deck not marked. Mark designated emergency exits on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR".
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Emergency Exits marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2021 Resolved
Temporary repair (putty) present on pipe underneath main deck. Conduct permanent repair on pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Optested/SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Various light sockets observed without bulbs. Ensure all sockets are installed with bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2021 Resolved
Two ring buoys found wasted/torn. Replace two ring buoys on upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Ring buoys replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 June 2021 Resolved
Unable to verify proper function of fixed firefighting shutdown/override and fixed fire detection. Prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Fire servicing receipt provided.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 June 2021 Resolved
Vessel's master was unfamiliar with emergency fuel/vent shutoffs. Ensure crew receive training on use/function.
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: Training conducted during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2021 Resolved
Bilge valves not labeled for spaces served. Label valves to designate spaces served. Crew confusion over spaces served.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Valves labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2021 Resolved
Hot water tank in STBD lazarette wasted. Replace prior to use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Loose wiring on compressor in STBD lazarette. Repair/replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Attended VSL. Verified SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 June 2021 Resolved
Deck hatch on STBD bow leaking excessively. Repair/replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Removed debris from sealing surfaces and water tested w/ hose. SAT
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2021 Resolved
KAPOK work vests used by crew during man overboard drill found unserviceable. Replace with suitable life/work vests.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 21 June 2021
Resolution: New life jackets placed in service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 June 2021 Resolved
Various doors on deck house found not to be weathertight. Ensure all doors on the deck house are weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 9 June 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Various wire runs below deck supported with plastic ties. Ensure wire runs below deck accessible by the crew are installed with metallic supports. Ensure wire runs above doorways utilize metallic supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Old T does not require.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
Junction box in STBD engine room hanging. Affix junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2021 Resolved
Loose wire connections found on starter of STBD main engine. Tighten loose connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Attended VSL. Verified SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 June 2021 Resolved
Generator solenoid in port engine room missing mounting screw. Install missing mounting screw.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021 Resolved
4x4 Junction box appeared to have electrical burns/mold. Open junction box to verify damage if any. Repair/replace as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 June 2021 Resolved
Emergency Egress door was unable to be easily opened in the event of Em Egress IAW 46cfr177.500(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 June 2020 Resolved
Ballast does not appear to comply with the provisions of the vessel's stability letter. Provide evidence to the attending marine inspector that the vessel's current ballast configuration complies with the vessel's stability letter.
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 16 July 2021
Resolution: Ballast issues resolved between navarc and MSC.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2020 Resolved
Electrical system appeared to have various changes including multi outlets, extension cords, splices, dead end wires, new pumps, lighting, appliances etc...Remove all unauthorized electrical additions. Ensure electrical system complies with original Coast Guard approved electrical plans.
Action required: 705 - Other - as specified
Due 31 July 2020
Resolved 8 July 2021
Resolution: Various electrical additions removed. Plans deferred to next DDX.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 June 2019 Resolved
Vessels flares were expired. Provide new flares.
Due 21 June 2019
Resolved 21 June 2019
Resolution: New flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 21 June 2019 Resolved
Vessel did not have a life jacket placard displayed. Provide placard.
Due 5 July 2019
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 August 2018 Resolved
The Certificate of Inspection was beyond it's validity dates when the vessel operated between July 30, 2018 and August 2, 2018. The 90 day waiver ended on July 29, 2018.
Due 2 August 2018
Resolved 2 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018 Resolved
Bilge piping in stbd side LAZ found disconnected. Re- solder pipe and test to satisfaction of attending MI.
Action required: 10 - Deficiency Rectified
Due 2 August 2018
Resolved 2 August 2018
Resolution: Section of piping was replaced and tested.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 August 2018 Resolved
Leak found in FF piping stbd side ER repair/replace section of piping and test.
Due 9 August 2018
Resolved 17 August 2018
Resolution: Leak properly repaired and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2018 Resolved
Weathered KAPOK PFD's found in poor condition with many no longer holding air. Submit replacement plan to the satisfaction of the Couast Guard.
Due 9 August 2018
Resolved 9 August 2018
Resolution: 90 PFD's have been replaced and final amount of KAPOKS will be replaced by next inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 August 2018 Resolved
Fuel shut off valve was unable to close completely. Repair the valve handle to ensure the valve fully closes.
Due 2 August 2018
Resolved 2 August 2018
Resolution: Valve repaired and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 August 2018 Resolved
Poor house keeping found on generator. Clean vents on the gen side of the unit.
Due 9 August 2018
Resolved 10 August 2018
Resolution: Gen set cleaned and verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2018 Resolved
Exposed wiring found on stbd side next to the sewage pump. Provide proper connection.
Due 9 August 2018
Resolved 10 August 2018
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 August 2018 Resolved
PA system does not operate on main deck. Ensure proper operation.
Due 3 August 2018
Resolved 3 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2018 Resolved
Missing indicator light for pre-engineered system on the bridge. Repair/Replace.
Due 9 August 2018
Resolved 17 August 2018
Engineering › Bilge Water Management System › Piping
Issued 4 May 2018 Resolved
Make repairs to bilge piping in LAZ.
Action required: 10 - Deficiency Rectified
Resolved 24 May 2018
Resolution: Section of piping was installed to the satisfaction of attending MI.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2017 Resolved
A valve with a garden hose was installed below the galley hatch (under sink). If the hose and connection are to remain, a check valve must be installed to ensure the system is unable to back flood the lazarette.
Due 30 August 2017
Resolved 11 June 2018
Resolution: Appeal denial from OCMI was handed down to the operator and def was resolved by removing the unauthorized fitting.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 August 2017 Resolved
Bilge high level alarm (audible) in tharboard side head found INOP. Ensure both visual and audible alarms work on the bridge.
Due 30 August 2017
Resolved 28 September 2017
Resolution: Bilge Alarm Tested Sst.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 August 2017 Resolved
The distribution panel in the galley was found with no cover. A cover must be installed.
Due 30 August 2017
Resolved 29 August 2017
Resolution: New cover has been installed.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2017 Resolved
A leak was found in the bilge piping appriximately 1.5' forward of the overboard on the transom. The piping is leaking at a union installed in the copper piping.
Due 30 August 2017
Resolved 5 September 2017
Resolution: New section of piping was soldered on and union was tightened. Tested bilge system with no leaks noted. SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 16 August 2017 Resolved
02 life rings were found unsurvicable must be replaced.
Due 30 August 2017
Resolved 29 August 2017
Resolution: New ring buoys have been provided on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017 Resolved
An abandoned electrical box was found just above the hatch for the lazarette. Ensure wires are not live and remove box and dead ended wires.
Due 30 August 2017
Resolved 29 August 2017
Resolution: Abandoned box and wires have been removed.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2017 Resolved
Bilge piping valve at the pump port side in laz is leaking. Replace valve or valve parts to correct leak.
Due 30 August 2017
Resolved 5 September 2017
Resolution: New valve was installed. Tested system. SAT.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 August 2017 Resolved
No life line provided on any of the vessels ring buoys. Provide life line IAW 46CFR 180.70.
Due 30 August 2017
Resolved 5 September 2017
Resolution: 60 FT of line was provided with forward ring buoy. SAT.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 August 2017 Resolved
The vessel could not show proof of enrollment with a valid consortium for pre-employment or random drug testing.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Vessel provided all required documentation.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 August 2017 Resolved
The vessel has no means to collect and have available all documentation referring to the vessel's Drug and Alcohol testing program.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Vessel has provided all required documentation.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 16 August 2017 Resolved
The vessel was operating with crew members not listed on the current drug testing roster.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 16 August 2017
Navigation › Piloting/Steering › Marine Charts
Issued 21 October 2014 Resolved
Provide current and up to date charts.
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 27 April 2015
Resolution: New charts on board.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 October 2014 Resolved
Provide FCC safety certificate.
Action required: 705 - Other - as specified
Due 1 June 2015
Resolved 1 June 2015
Resolution: Received proper copy
Documentation › Certificates/Documents › FCC SSL
Issued 21 October 2014 Resolved
Provide FCC station license.
Action required: 705 - Other - as specified
Due 1 June 2015
Resolved 1 June 2015
Resolution: Received copy
Operations/Management › Passenger Operations › Safety Orientation
Issued 21 October 2014 Resolved
Provide means to record passenger count ashore.
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 27 April 2015
Resolution: Passenger count available shore side at restautant owned by the vsl owner.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 October 2014 Resolved
Provide current Coast Pilot [name withheld] and Tide and Current tables.
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 27 April 2015
Resolution: New tide tables provided.
Lifesaving › Hand Flares › Expired
Issued 21 October 2014 Resolved
Renew expired flares.
Action required: 705 - Other - as specified
Due 21 October 2014
Resolved 30 April 2015
Navigation › Piloting/Steering › Compass Deviation Table
Issued 21 October 2014 Resolved
Provide compass deviation table. Talked with vessels owner who has a scheduled proffesional to swing his compas on Sat 30May15.
Action required: 705 - Other - as specified
Due 1 June 2015
Resolved 1 June 2015
Resolution: Received copy of proper Deviation table swung on 30 May...,
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 21 October 2014 Resolved
Repair fuel leak, stbd generator, prior to carrying passengers.
Action required: 705 - Other - as specified
Due 21 October 2014
Resolved 27 April 2015
Resolution: Fuel leak corrected.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 October 2014 Resolved
Tighten stbd engine alternator belts.
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 27 April 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 October 2014 Resolved
Mount high level float in starboards lazz.
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 27 April 2015
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 October 2014 Resolved
Prior to carriage of passengers complete inspection for certification. Vessel COI has been deactivated.
Action required: 705 - Other - as specified
Due 9 October 2014
Resolved 21 October 2014
Documentation › Certificates/Documents › Stability Letter
Issued 19 January 2012 Resolved
Vessel must submit calculations to MSC for review/approval for compliance with new AAWPP of 185 lbs. prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2012
Resolved 23 March 2012
Resolution: Received new stability letter from MSC. Total persons allowed reduced from 169 to 155.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 July 2011 Resolved
Complete required fire fighting and Man Overboard Drills and log date and general description. (Owner/Operator states FF and MOB drills were conducted but not logged.) MOB drill completed with CG on board.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 25 August 2011
Resolution: Vessel completed MOB drill but still has no record of FF drill. Wrote a new discrepancy to complete FF drill.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 July 2011 Resolved
All Betteries properly secured in tray/box resistant to damage by electrolyte.
Condition: Improper Installation
Due 26 August 2011
Resolved 27 July 2011
Resolution: Re-wired all float switches and electrical bilge pumps to the satisfaction of the marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2011 Resolved
Properly wire/secure unused wiring for MSD systems-Port/Stbd.
Condition: Improper Installation
Due 26 August 2011
Resolved 25 August 2011
Electrical › Electric Supply System (service) › Battery Conductor
Issued 26 July 2011 Resolved
Re-affix Perko battery selector switch to bulkhead-Port side.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 27 July 2011
Resolution: Battery switch secured to bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2011 Resolved
Repair/Replace bilge pump wiring throughout vessel. Properly crimp and insulate.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2011
Engineering › Bilge Water Management System › Pump
Issued 26 July 2011 Resolved
Ensure all bilge pumps are permanantly mounted.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: Bilge pumps affixed to engine compartment deck.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 July 2011 Resolved
Replace raw water hose-aft STDB engine. Hose cracked and worn.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 27 July 2011
Resolution: New hose installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 26 July 2011 Resolved
Provide adequate means to seal engine space vents in event of fire. (Ventilation hoses not permanently affixed and neft football used to plug vents missing.)
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 25 August 2011
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 26 July 2011 Resolved
Secure heat shielding on engine room compartment bulkhead and apply where missing (exposed plywood).
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 25 August 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 July 2011 Resolved
Install double hose clamps on all hoses where missing-port/stbd engine, generator and bilge system flex hose.
Condition: Improper Installation
Due 26 August 2011
Resolved 25 August 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 26 July 2011 Resolved
Install chaffing gear on raww water hose and hydraulic hose for STBD engine throttle.
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 25 August 2011
Operations/Management › Drills/Instruction › Fire
Issued 26 July 2011 Resolved
Second requirement to perform and log a fire fighting drill with the vessel's crew. Vessel O/O was verbally instructed to perfrom a FF drill prior to sailing when the crew arrives for the next cruise.
Condition: Improper/Lack of Maintenance
Due 27 August 2011
Resolved 25 October 2011
Resolution: Inspected the vessels logs and each drill; had been logged for the past two months with sat results.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 July 2011 Resolved
Replace raw water hose on Port and Starboard generators.
Condition: Improper/Lack of Maintenance
Due 25 September 2011
Resolved 25 October 2011
Resolution: Vessels owner replaced the effected hose with sat results.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 July 2011 Resolved
Clamp hard pipe for raw awater line on stbd side of engine.
Condition: Improper Installation
Due 25 September 2011
Resolved 25 October 2011
Resolution: Vessel reps hung properly the hard piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 26 July 2011 Resolved
Re-route crank case breather hoses.
Condition: Improper Installation
Due 25 September 2011
Resolved 25 October 2011
Resolution: Vessels reps relocated the cranckcase breather hose the the intake where it belongs.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 July 2011 Resolved
Double hose clamps on exhaust-stbd engine.
Condition: Improper Installation
Due 25 September 2011
Resolved 25 October 2011
Resolution: Vessels reps added double hose clamps to the exhaust system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 July 2008 Resolved
Properly service all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 8 July 2008 Resolved
Properly service all fixed fire extinguishing systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Fire Fighting › Fire Hoses › Condition
Issued 8 July 2008 Resolved
Replace starboard fire hose on the upper deck that is no longer serviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Fire Fighting › Fire Main › Valves
Issued 8 July 2008 Resolved
Repair valve at port fire hose station on the upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Lifesaving › Hand Flares › Expired
Issued 8 July 2008 Resolved
Provide required orange day smoke distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 July 2008 Resolved
Conduct satisfactory underway man overboard drill.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 July 2008 Resolved
Prove proper operation of all emergency lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2008
Resolved 8 July 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 July 2008 Resolved
Provide proof of enrollment in a drug testing program and an up to date roster.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Observed proof of enrollment in drug testing program with up to date roster.
Documentation › Logs/Records › Logbook (official)
Issued 8 July 2008 Resolved
Provide training logbook.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verifed presence of training logbook.
Lifesaving › Lifebuoys › Serviceable
Issued 8 July 2008 Resolved
Provide retro reflective tape on aft ring life buoy and ring life buoy in main deck passenger accommodation space.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Observed retro reflective tape on aft ring life buoy and ring life buoy in main deck passenger accomodation space.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 July 2008 Resolved
Ensure ring life buoy in main deck accommodation space is properly marked with vessels name.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 July 2008 Resolved
Provide a PFD donning placard.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verfied presence of PFD donning placards.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 July 2008 Resolved
Properly mark sizes and capacity on upper deck PFD storage containers adjacent to the operators station.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verified proper marking on PFD storage containers on the upperdeck.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 July 2008 Resolved
Properly secure all appliances and gear adrift in galley.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Observed adequate securing methods employed for appliances and gear adrift in galley.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 July 2008 Resolved
Secure/replace lighting wiring/fixtures in galley.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Observed that galley lighting fixtures had been replaced satisfactorily.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 July 2008 Resolved
Properly cover and secure wiring in junction box with loose wiring above port side steering gear.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verified junction box and loose wiring have been properly secured above port steering gear.
Engineering › Fuel Oil Service System › Filter
Issued 8 July 2008 Resolved
Provide flame arrestor bowls for fuel filters on port and starboard main engines.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verifed that flame arrestor bowls are fitted on port and starboard main engine fuel filters.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 July 2008 Resolved
Properly secure all batteries in machinery spaces.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verfied tthat batteries in machinery spaces have been secured.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 July 2008 Resolved
Properly insulate exhaust piping for starboard main engine.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verified that exhaust piping on stbd main has been properly insulated.
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 8 July 2008 Resolved
Prove proper operation of hinges and latching mechanisms on forward accommodation doors.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: witnessed proper operation of hinges and latching mechanisms on forward accomodation doors.
Fire Fighting › Fire Pumps › Pressure
Issued 8 July 2008 Resolved
Provide pressure gauge at discharge side of fire pump.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Observed operation of pressure guage at discharge side of fire pump.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 July 2008 Resolved
Provide a satisfactory rescue platform as discussed with the CG marine inspector and conduct a satisfactory MOB drill with rescue platform to the satisfaction of the attending CG marine inspector.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Observed satisfactory completion of MOB drill utilizing new rescue platform.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 July 2008 Resolved
Provide proper rail height and rail courses on port and starboard side of operators station as discussed with the CG marine inspector.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 8 August 2008
Resolution: Verified installation of adequate gates on each side of the operator''s station.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 13 September 2007 Resolved
POST EMERGENCY INSTRUCTIONS AT THE OPERATORS STATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 September 2007
Resolved 19 September 2007
Fire Fighting › Means of Escape › Doorways
Issued 13 September 2007 Resolved
OUTFIT ALL MAIN DECK EXTERIOR DOORS WITH LATCHING DEVISES AS ORIGNALLY REQUIRED WHEN DOORS WERE INSTALLED.
Action required: 705 - Other - as specified
Due 21 September 2007
Resolved 19 September 2007
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 2 May 2007 Resolved
Secure ballast in both steering spaces.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 6 June 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 May 2007 Resolved
Properly stow all loose gear in both steering compartments. Clean both steering compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 6 June 2007
Engineering › Freshwater Generation System › Piping
Issued 2 May 2007 Resolved
Repair potable water leak in starboard steering space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 4 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 2 May 2007 Resolved
Wipe down fuel on starboard main engine, find, and repair leaks
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Resolution: Fuel lines tightened on stbd main engine. Check ride conducted to confirm.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 May 2007 Resolved
Install missing access panel leading to tunnel in starboard engine compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 4 May 2007
Resolution: Access panel installed.
Electrical › Electric Supply System (service) › Cable
Issued 2 May 2007 Resolved
Tighten loose battery connections on starboard generator set.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 4 May 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 2 May 2007 Resolved
Provide non-combustible ventilation ducts and closure devices in both engine compartment ventilation systems.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 6 June 2007
Fire Fighting › Ventilation Systems › Fans
Issued 2 May 2007 Resolved
Prove proper operation of power ventilation system. Prove power ventilation shutdowns occur during engine compartment fixed fire system activation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 14 June 2007
Resolution: Electrician wired ventilation shutdown into the fixed fire fighting system. Witnessed operational test. Upon testing, when activated, main engine, generator and power ventilation shutdowns now operate properly in both port and starboard engine rooms.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 2 May 2007 Resolved
Make watertight, a hole cut in aft watertight bulkhead in starboard fuel void.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 4 May 2007
Engineering › Bilge Water Management System › Pump
Issued 2 May 2007 Resolved
Reroute wires to high bilge alarm in port engine compartment. Current arrangement allows for the wires to block the float level.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 May 2007 Resolved
Remove multi-gang outlet on port side of main passenger space on lower deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 4 May 2007
Engineering › Bilge Water Management System › Manifold
Issued 2 May 2007 Resolved
Prove proper operation of bilge manifold system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Resolution: Filled port and starboard focs''l voids with fresh water and pumped out.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2007 Resolved
Both powered bilge pumps are seized. Replace and test for proper operation both bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Resolution: Both bilge pumps replaced and tested by pumping out forecastle voids.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 May 2007 Resolved
Renew fire pump breaker on main power panel. Breaker will not reset or turn off.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 4 May 2007
Fire Fighting › Fire Bucket › Availability
Issued 2 May 2007 Resolved
Provide three two and 1/2 gallon fire buckets properly marked and lanyards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 4 May 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 May 2007 Resolved
Provide bonding cable for fuel fill hose for both port and starboad fuel fills.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 4 May 2007
Resolution: Installed
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 May 2007 Resolved
Provide emergency flashlights at the following locations: 1 at operators station, 1 entrance to port engine room, 1 entrance to starboard engine room
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 4 May 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 May 2007 Resolved
Provide bonding cable for port void fuel tank between flexible rubber hose joint.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 4 May 2007
Resolution: Installed
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 May 2007 Resolved
Provide training for 50% of crew for first aid/CPR
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 14 June 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 May 2007 Resolved
Update training log. Prove proper crew training by conducting and logging drill.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Resolution: Vessel created training log. Underway man overboard, engine room fire drill, and damage control drill conducted.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 May 2007 Resolved
Provide Coast Pilot, corrected charts, CG light list and tide/current tables
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 6 June 2007
Resolution: Nav pubs onboard
Operations/Management › Drills/Instruction › Fire
Issued 2 May 2007 Resolved
Provide fire system service report
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 14 June 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 May 2007 Resolved
Provide current COD onboard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 4 May 2007
Resolution: Owner found current COD and placed on vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 2 May 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 14 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 May 2007 Resolved
Prove proper operation of all ten bilge space alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Resolution: Replaced seven faulty bilge alarm float switches and tested, sat.
Engineering › Diesel Engine (auxiliary) › Block
Issued 2 May 2007 Resolved
Number two generator overheating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2007
Resolved 5 May 2007
Resolution: Number two generator prime mover found to be low on jacket water. Filled, placed on line and tested. sat
Electrical › Electric Generation Source (service) › Generator
Issued 7 April 2006 Resolved
Tighten main breaker box on # 2 Generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 April 2006 Resolved
Clean all bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Feedwater/Condensate Water System › Valve
Issued 7 April 2006 Resolved
Renew seawater valve through hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Fuel Oil Service System › Piping
Issued 7 April 2006 Resolved
Renew FUEL HOSE/FITTING to SAE 1942 standard or equivalent on # 2 Generator
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2006 Resolved
Renew seawater hose on # 2 Generator
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2006 Resolved
Permanently affix solenoid starter to # 2 main engine, clean all electrical wiring/renew where necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2006
Engineering › Fuel Oil Service System › Piping
Issued 7 April 2006 Resolved
Renew fuel lines to #2 maine engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 7 April 2006 Resolved
Repair engine room lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 7 April 2006 Resolved
Replace battery box in # 1 engine room
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Generation Source (emergency) › Conductor
Issued 7 April 2006 Resolved
Repair cable clamps going into battery charger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Generation Source (emergency) › Switch
Issued 7 April 2006 Resolved
Provide battery switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 7 April 2006 Resolved
Rewire battery charger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Fuel Oil Service System › Piping
Issued 7 April 2006 Resolved
Secure or renew fuel lines/piping to #1 generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Bilge Water Management System › Pump
Issued 7 April 2006 Resolved
Provide junction box or renew cable to overboard pump in # 1 engine space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2006 Resolved
Provide double hose clamp on salt water cooling.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Fuel Oil Service System › Hose
Issued 7 April 2006 Resolved
Renew fuel hose on #1 generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 7 April 2006 Resolved
Permanently cap off through hull located on salt water service for sanitary system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 7 April 2006 Resolved
Provide double hose clamp on fresh water cooling system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 7 April 2006 Resolved
Provide double hose clamps on #1 generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 7 April 2006 Resolved
Tighten down generator boxes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 7 April 2006 Resolved
Clean salt, from hose leaks, off of # 1 generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 April 2006 Resolved
Entirely remove temporary flex hose fuel system and connections to both tanks need to be threaded and capped.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 April 2006 Resolved
Remove all combustable material from bilge spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 7 April 2006 Resolved
Renew spliced cable in fore peak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 7 April 2006 Resolved
Run ground wire to engine room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Bilge Water Management System › Piping
Issued 7 April 2006 Resolved
Properly support bilge piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Bilge Water Management System › Piping
Issued 7 April 2006 Resolved
IDENTIFY pumps and piping in fore peak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 April 2006 Resolved
Provide junction box or rerun of all apliced wiring in fore peak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2006 Resolved
Properly support all wiring every 24" throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2006 Resolved
Remove dead end wiring in female head's void spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2006 Resolved
Remove dead end wiring in male head blower room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 7 April 2006 Resolved
Renew packing or seal up all penetrations through watertight bulkheads in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2006
Engineering › Sea-water System (primary cooling)
Issued 27 October 2003 Resolved
REPLACE RAW WATER BY PASS VALVE ON PORTSIDE. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 October 2003
Resolution: VALVE RENEWED
Accommodation/Occupational Safety › Occupational Safety
Issued 27 October 2003 Resolved
REPLACE DOOR KNOBS ON EXIT DOORS LEADING TO UPPER DECK. LEGACY COMPONENT DESC: Hand Grab
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 October 2003
Resolution: DOOR KNOBS INSTALLED ON DOORS
Pollution Prevention/Response › Prevention Equipment
Issued 27 October 2003 Resolved
FIX MSD VACUUM PUMP LEAKS LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 October 2003
Resolution: LEAKS CORRECTED WITH NEW PIECE OF PVC PIPE
Engineering › Compressed Air System (control)
Issued 27 October 2003 Resolved
CONNECT FAN HOSE TO BLOWER BEHIND TOILET PORT HEAD COMPARTMENT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 October 2003
Resolution: FAN HOSE CONNECTED TO BLOWER
Accommodation/Occupational Safety › Heating
Issued 27 October 2003 Resolved
REPLACE DUCT TAPE ON PORTSIDE GALLEY HEATER WITH HOSE CLAMP LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 October 2003
Resolution: HOSE CLAMP INSTALLED
Documentation › Certificates/Documents
Issued 9 July 2003 Resolved
Doc of Compliance not on board for unknown reasons. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: DOC FOUND AND BROUGHT ON VESSEL.
Fire Fighting › Fire Hydrants › Condition
Issued 9 July 2003 Resolved
Valve for fire hose, stbd side main deck, broken. Valve unable to be opened.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: Valve replaced.
Navigation › Piloting/Steering
Issued 9 July 2003 Resolved
Deviation card missing. LEGACY COMPONENT DESC: Deviation Table/Graph
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 July 2003
Resolved 23 July 2003
Resolution: OWNER HAD COMPASS CALIBRATED.
Communications › Alarms/Indicators
Issued 9 July 2003 Resolved
Bilge alarms in pilothouse not labeled to indicate which space affected. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: BILGE ALARM PANEL LABELED PROPERLY.
Lifesaving › Lifebuoys
Issued 9 July 2003 Resolved
Renew or ensure all float lights work as intended. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: BATTERIES REPLACED
Lifesaving › Lifebuoys
Issued 9 July 2003 Resolved
Renew all waterlight batteries. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: OWNER OPTED TO REMOVE BA FROM VESSEL
Lifesaving › Buoyant Apparatus
Issued 9 July 2003 Resolved
Weaklink attachment points (stanchons) to vessel broken.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: OWNER OPTED TO REMOVE BA FROM VESSEL
Lifesaving › Buoyant Apparatus
Issued 9 July 2003 Resolved
Provide spacers for BA's stacked on one another.
Condition: Improper Installation
Due 15 July 2003
Resolved 9 July 2003
Resolution: OWNER OPTED TO REMOVE BA FROM VESSEL
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 July 2003 Resolved
Stbd fuel tank has cracked weld. Make permanent repairs.
Condition: Unknown
Due 31 October 2003
Resolved 21 June 2005
Resolution: Starboard tank repaired but not in use. Flexible fuel hose was installed so that starboard engine can draw fuel from port fuel tank.
Electrical › Lighting (emergency)
Issued 9 July 2003 Resolved
Ensure batteries/flashlights in pilothouse work as intended. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: BATTERIES REPLACED IN FLASHLIGHT.
Operations/Management › Drills/Instruction
Issued 9 July 2003 Resolved
Posted lifejacket donning procedures weather worn, almost un-readable.
Condition: Improper/Lack of Maintenance
Due 15 July 2003
Resolved 9 July 2003
Resolution: PLACARD POSTED IAW WITH REGS.
Communications › Alarms/Indicators
Issued 9 July 2003 Resolved
Light inoperable in fire panel in pilothouse. LEGACY COMPONENT DESC: Fire Alarm
Condition: Improper/Lack of Maintenance
Due 15 July 2003
Resolved 9 July 2003
Resolution: LIGHT FIXED IN PANEL.
Operations/Management › Drills/Instruction
Issued 9 July 2003 Resolved
Crew unfamiliar with certain aspects of vessel operation, including emergency drills, bilge system setup, fire fighting and man overboard. Provide training as required.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 10 July 2003
Resolution: CAPTAIN AND CREW DRILLED AND CONDUCTEDTRAINING AS REQUIRED.
Electrical › Electric Supply System (service)
Issued 9 July 2003 Resolved
Electrical shore tie worn/chaffed. Renew/replace, prior to next use. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 23 July 2003
Resolution: OWNER PROCURED NEW SHORE TIE CABLE AND INSTALLED
Accommodation/Occupational Safety
Issued 9 July 2003 Resolved
Lube oil stored in galley area. Remove and stow properly.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: OIL REMOVED FROM SUBJ SPACE.
Engineering › Fuel Oil Storage/Transfer System
Issued 9 July 2003 Resolved
Bucket of fuel oil found in fuel tank compartment. Remove.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: BUCKET OF FUEL REMOVED.
Deck/Cargo › Mooring/Anchoring
Issued 9 July 2003 Resolved
Aft mooring line chaffed. Replace, and check remaining mooring lines. LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2003
Resolved 9 July 2003
Resolution: MOORING LINE RENEWED
Accommodation/Occupational Safety › Ventilation
Issued 9 July 2003 Resolved
Repair/renew engine room vent hoses which lead through galley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: HOSES REPAIRED OR PROPERLY CONNECTED.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 9 July 2003 Resolved
Remove strong odor of sewage in washroom areas. Troubleshoot, identify cause and correct. Report findings to attending OCMI.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2003
Resolved 9 July 2003
Resolution: COMPARTMENT CLEANED AND INSPECTED FOR LEAKS, APPARENT SMELL CAME FROM A PREVIOUS LEAK DURING PUMP OUT WHICH WAS RESOLVED BY CREW.
Construction/Loadline › Hull › Side Shell
Issued 9 July 2003 Resolved
Several cracks in hull and superstructure FRP. Identify and repair.
Condition: Unknown
Due 31 October 2003
Resolved 7 April 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 August 2002 Resolved
STBD FUEL TANK CRACKED AT UPPER SEAM DUE TO PRESSURE CAUSED BY FUELING, TEMP REPAIRS IN PLACE TO ALLOW CONTINUED USE OF VESSEL UNTIL PERMANENT REPAIRS CAN BE MADE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 21 June 2005
Resolution: Starboard tank repaired but not in use. Both engines drawing fuel from port tank.
Electrical › Electrical Distribution System (service)
Issued 1 May 2002 Resolved
REPAIR VOLT METER ON ELECTRICAL PANEL ON BRIDGE LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 5 June 2002
Operations/Management › Drills/Instruction
Issued 1 May 2002 Resolved
CONDUCT DRILLS PRIOR TO CARRYING PASSENGERS LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2002
Resolved 21 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 1 May 2002 Resolved
CORRECT BILGE ALARM PANEL TO CORRESPNOND WITH CORRECT COMPARTMENT LISTED ON PANEL. LEGACY COMPONENT DESC: Bilge Monitor
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2002
Resolved 21 May 2002
Engineering
Issued 4 October 2001 Resolved
RENEW PLASTIC FITTING IN FUEL OIL TANK VENT LINE AND RENEW WITH METALLIC FITTING.
Condition: Unknown
Due 12 October 2001
Resolved 12 October 2001
Construction/Loadline
Issued 4 October 2001 Resolved
GRIND OUT AND RENEW AS ORIGINAL FIRST LAYER OF GLASS AT STARBOARD TRANSOM AT TURN OF BILGE. AREA APPROXIMATELY 36" BY 8 INCHES.
Condition: Unknown
Due 12 October 2001
Resolved 12 October 2001
Construction/Loadline › Hull › Bottom Plating
Issued 4 October 2001 Resolved
GRIND OUT AND RENEW AS ORIGINAL STARBOARD TRANSOM AREA
Condition: Improper Installation
Due 4 October 2001
Resolved 9 October 2001
Engineering › Fuel Oil Service System › Hose
Issued 4 October 2001 Resolved
RENEW PLASTIC FITTING IN FUEL OIL FILL LINE
Condition: Improper Installation
Due 4 October 2001
Resolved 9 October 2001
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
INSTALL RAIL ON TOP OF ELECTRIC STOVE TO KEEP POTS FROM FALLING OFF TOP.
Condition: Unknown
Due 5 June 2001
Resolved 6 June 2001
Fire Fighting
Issued 4 June 2001 Resolved
REPLACE MISSING BULKHEAD PANEL IN STBD ENGINEROOM
Condition: Unknown
Due 5 June 2001
Resolved 6 June 2001
Electrical
Issued 4 June 2001 Resolved
REPAIR OVERHEAD LIGHT IN GALLEY
Condition: Unknown
Due 5 June 2001
Resolved 6 June 2001
Accommodation/Occupational Safety
Issued 4 October 2000 Resolved
REPAIR WATER LEAK ORIGINATIONG IN GALLEY AND LEAKING INTO ENGINEROOM.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Electrical
Issued 4 October 2000 Resolved
REPAIR EMERGENCY LIGHTING.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 4 October 2000 Resolved
CLEAN BILGES IN BOTH ENGINEROOMS AND BOTH STEERING COMPARTMENTS
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Engineering
Issued 4 October 2000 Resolved
REPAIR OIL LEAK ON OUTBOARD SIDE OF STBD ENGINE.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 4 October 2000 Resolved
REPAIR ENGINEROOM VENT HOSES ON PORT SIDE.
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 4 October 2000 Resolved
PROVIDE DIVE REPORT SURVEY
Condition: Unknown
Due 6 October 2000
Resolved 18 October 2000
Navigation
Issued 4 October 2000 Resolved
TIGHTEN RUDDER PACKING ON STBD RUDDER
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 4 October 2000 Resolved
REMOVE STORES FROM AROUND CABIN HEATER, PORT SIDE.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Construction/Loadline
Issued 4 October 2000 Resolved
MOVE BALLAST IN STBD STEERING SPACE TO MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Construction/Loadline
Issued 4 October 2000 Resolved
DRYDOCK VESSEL OR PROVIDE DIVE REPORT TO HULL CONDITION.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 21 June 2000 Resolved
RENEW BROKEN WATERLIGHT BRACKETS
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Lifesaving
Issued 21 June 2000 Resolved
STENCIL VESSEL NAME ON 1 CHILD PFD.
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Navigation
Issued 21 June 2000 Resolved
PROVIDE RULES OF THE ROAD
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Construction/Loadline
Issued 21 June 2000 Resolved
REPAIR BILGE ALARM SYSTEM
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Construction/Loadline
Issued 1 May 2000 Resolved
CONDUCT UT READINGS OF INNER HULL TO DETERMINE CONDITION OF THE INNER LAMINATE TO CORE BOND. READINGS TO BE CONDUCTED IN THE PRESENCE OF A MARINEINSPECTOR._x001C_
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Construction/Loadline
Issued 1 May 2000 Resolved
REMOVE AND REPAIR IAW NVIC 8-87 ALL BLISTERED AND DELAMINATED AREAS OF THE HULL AS MARKED BY THE MARINE INSPECTOR DURING THIS INSPECTION._x001C_ DELAMINATION AND BLISTERING IS NOTED THROUGHOUT THE UNDERWATER BODY._x001C_ _x001C_
Condition: Unknown
Due 30 October 2000
Resolved 22 May 2000
Construction/Loadline
Issued 25 October 1999 Resolved
CONDUCT CREDIT HULL EXAMINATION WITH COAST GUARD MARINE INSPECTOR._x001C_ VESSEL IS PROHIBITED FROM CARRYING PASSENGERS AFTER 30 NOVEMBER 1999 UNTIL THIS CREDIT HULL EXAMINATION IS CONDUCTED.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Electrical
Issued 10 May 1999 Resolved
PROPERLY SPLICE CABLE TO CIRCULATING PUMP FOR HEAT/AC SYSTEM, STBD SIDE.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Lifesaving
Issued 10 May 1999 Resolved
REPLACE PLASTIC GARBAGE CAN WITH METAL ONE.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Electrical
Issued 10 May 1999 Resolved
PROPERLY DEAD END OR REMOVE UNUSED WIRING.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Electrical
Issued 10 May 1999 Resolved
REPLACE BATTERY FOR GALLEY EMERGENCY LIGHTING.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Lifesaving
Issued 10 May 1999 Resolved
PROVIDE SPLINT FOR FIRST AID KIT.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Lifesaving
Issued 10 May 1999 Resolved
MISSING 1 LIFEJACKET AS REQUIRED BY COI.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Lifesaving
Issued 10 May 1999 Resolved
REPLACE RETRO REFLECTIVE TAPE AND PATCH LIFE FLOATS.
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Engineering
Issued 10 May 1999 Resolved
Replace the plastic drain valves on the Racor filters with metal valves._x001C_
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Engineering
Issued 10 May 1999 Resolved
Replace the worn fuel hose between the strainer and the engine for the starboard genset._x001C_
Condition: Unknown
Due 19 May 1999
Resolved 20 May 1999
Electrical
Issued 22 May 1998 Resolved
MAKE PROPER WIRE CONNECTIONS TO LOOSE ENDED WIRES THROUGHOUT VESSEL IN ACCORDANCE WITH 46 CFR PART 183. WIRES NOT IN CONNECTION BOXES.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Accommodation/Occupational Safety
Issued 22 May 1998 Resolved
REPAIR OR REPLACE SINK DRAIN IN GALLEY. DRAIN PIPE TAPED IN PLACE.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Accommodation/Occupational Safety
Issued 22 May 1998 Resolved
PROPERLY SECURE TOP WINDOW TO THE FORWARD DOOR LOCATED ON THE MAIN DECK.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 22 May 1998 Resolved
REMOVE ALL NON GROUNDING PORTABLE ELECTRICAL EXTENSION CORDS AND REPLACE WITH PROPER 3 WIRE GROUNDING CORDS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 22 May 1998 Resolved
REPIAR OR REPLACE CYCLE METER ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 22 May 1998 Resolved
STRAP DOWN BATTERY BOXES IN PORT AND STARBOARD ENGINE ROOM.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 22 May 1998 Resolved
PROPERLY DEAD END WIRES IN BREAKER PANEL IN GALLEY.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Construction/Loadline
Issued 22 May 1998 Resolved
REMOVE WATER FROM ALL VOIDS. THIS IS TO BE COMPLETED PRIOR TO THE CARRIAGEOF PASSENGERS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 22 May 1998 Resolved
PROVIDE DOCUMENTATION THAT THE INSTALLED EPIRB IS REGISTERED TO THIS VESSEL.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 22 May 1998 Resolved
REPOSITION AND SECURE SPEAKER WIRE AROUND PILOT HOUSE SO THAT IT DOES NOT OBSTRUCT THE STARBOARD SIDE BUOYANT APPARATUS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Fire Fighting
Issued 22 May 1998 Resolved
REPAIR OR REPLACE FIRE PUMP DISCHARGE PRESSURE GUAGE.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 12 May 1997 Resolved
Install an automatically float free and activated Category 1, 406 MHZ EPIRBon board.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Lifesaving
Issued 12 May 1997 Resolved
Brightly paint and label flare box.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Lifesaving
Issued 12 May 1997 Resolved
Place retro-reflective tape on ring buoys.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Lifesaving
Issued 12 May 1997 Resolved
Stencil life jacket stowage on bench seat, port side forward.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Fire Fighting
Issued 12 May 1997 Resolved
Stencil vessel name on fire ax.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Lifesaving
Issued 12 May 1997 Resolved
Properly rig buoyant apparatus so that each BA is attached to the painter and free from contacting another BA in the group when deployed.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Documentation
Issued 12 May 1997 Resolved
Provide proper documentation of fully compliant chemical testing program. Marine employer is not authorized to operate after 12JUN97, unless this requirement has been cleared to the satisfaction of an attending USCG Marine Inspector.
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Construction/Loadline
Issued 12 May 1997 Resolved
Place required draft markings on vessel's hull.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Engineering
Issued 10 May 1996 Resolved
SUPPORT STARBOARD MDE SALT WATER OUTLET HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
POST PLACARD FOR UPPER DECK PASSENGER ALLOWANCE PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 15 May 1996
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
REPAIR SINK GRAY WATER DRAIN IN FORWARD HEAD STARBOARD SIDE FORWARD PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Documentation
Issued 10 May 1996 Resolved
POST STABILITY LETTER ON THE VESSEL PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Electrical
Issued 10 May 1996 Resolved
REMOVE ELECTRICAL JURY RIGGED WIRING FROM CANOPY AND BOTH ENGINEROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1996
Resolved 21 May 1996
Construction/Loadline
Issued 10 May 1996 Resolved
SECURE AND PROPERLY SUPPORT LEAD BALLAST P/S. WEIGHT CONCENTRATED ON HULL._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 7 June 1996
Engineering
Issued 10 May 1996 Resolved
DOUBLE CLAMP PORT FUEL FILL HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Navigation
Issued 10 May 1996 Resolved
VESSEL MAY NOT USE COMPRESSED AIR SYSTEM UNTIL RELIEF VALVE HAS BEEN ADDED AND ASME CODE HAS BEEN VERIFIED,AND PROVIDE THE SAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
PROVIDE FLASHLIGHTS AT ENTERANCE TO ENGINEROOMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
REMOVE SPARE FUEL CONTAINER FROM ENGINEROOM PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Engineering
Issued 10 May 1996 Resolved
REMOVE EXHAUST LAGGING FROM STARBOARD ENGINE EXHAUST FOR INSPECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 7 June 1996
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
STARBOARD SALT WATER AC INLET CONNECTION REQUIRES TIGHTENING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Navigation
Issued 10 May 1996 Resolved
REPAIR DAMAGED KEY WAY ON PORT TILLER ARM PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Electrical
Issued 10 May 1996 Resolved
REPAIR TWO LIGHT IN FORWARD HEAD ON STARBOARD SIDE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 10 May 1996 Resolved
REMOUNT EXTINGUISHER BRACKET BEHIND BAR ON UPPER DECK PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 10 May 1996 Resolved
REPLACE EXTINGUISHER BRACKET BEHIND MAIN DECK BAR PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 10 May 1996 Resolved
REPLACE PORTABLE EXTINGUISHER BII IN GALLEY PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Documentation
Issued 10 May 1996 Resolved
PLACE VESSEL'S DOCUMENTATION ONBOARD PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Navigation
Issued 10 May 1996 Resolved
UPDATE LOCAL CHARTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 21 May 1996
Navigation
Issued 10 May 1996 Resolved
PROVIDE TIDE TABLE FOR VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 21 May 1996
Unknown
Issued 10 May 1996 Resolved
PROVIDE WASTE MANAGEMENT PLAN FOR VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
POST PFD DONNING PLACARD PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Unknown
Issued 10 May 1996 Resolved
REPAIR ANCHOR BRACKET FOR STARBOARD ANCHOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 21 May 1996
Engineering
Issued 10 May 1996 Resolved
DOUBLE CLAMP PORT MDE SALT WATER HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Construction/Loadline
Issued 10 May 1996 Resolved
STARBOARD MACHINERY ROOM BILGE PUMP DISCHARGE THROUGH HULL REQUIRES TIGHTENING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Engineering
Issued 10 May 1996 Resolved
REPAIR PORT ENGINE EXHAUST SOFT PATCHED PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 10 May 1996 Resolved
MOUNT FIRE AX NEAR OR IN PILOT HOUSE PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
VESSEL REQUIRED TO PERFORM UNDERWAY EMERGENCY DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Electrical
Issued 10 May 1996 Resolved
DOUBLE CLAMP BOTH SALTWATER SUPPLY SUCTION LINES FOR BOTH GENERATORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Construction/Loadline
Issued 10 May 1996 Resolved
REPAIR BOTH CHAIN LOCKER HATCHES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
REMOVE FLAMABLE LIQUID STORES FROM FUEL TANK ROOM PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 21 May 1996
Lifesaving
Issued 10 May 1996 Resolved
SECURE FAN IN PORT AFT HEAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1996
Resolved 21 May 1996
Construction/Loadline
Issued 26 September 1995 Resolved
Reinstall 1.8 long tons of ballast as required by 9 Aug 90 G-MSC-1 stability letter or submit amended stability caculations to G-MSC for review.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995 Resolved
Affix electric submersible bilge pump to hull in port & starboard engine rooms. Install, use an oil and salt water resistant wire inserted hose_x001C_ and check valve at thru-hull fitting.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Construction/Loadline
Issued 26 September 1995 Resolved
Install sea valve on all sink over board thru-hull fittings (2 each).
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Lifesaving
Issued 18 July 1995 Resolved
Restencil lifejacket lockers with one inch tall lettering.
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Fire Fighting
Issued 18 July 1995 Resolved
Replace fire hose on second deck starboard station.
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Lifesaving
Issued 18 July 1995 Resolved
Replace one strobe water light.
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Electrical
Issued 20 July 1994 Resolved
Remove speaker wire from starboard forward compartment hatch.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Electrical
Issued 20 July 1994 Resolved
Replace wire nuts with crimp connectors on port and starboard sanitary pumps.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Lifesaving
Issued 20 July 1994 Resolved
Install box cover on switch in galley aft bulkhead.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Lifesaving
Issued 20 July 1994 Resolved
Provide reflective tape on all 3 ringbuoys.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Electrical
Issued 20 July 1994 Resolved
Provide battery box port generator and secure all boxes.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Fire Fighting
Issued 20 July 1994 Resolved
Repair fire pump housing prior to carrying passengers.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Electrical
Issued 20 July 1994 Resolved
Demonstrate operation of port S/S generator.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Electrical
Issued 20 July 1994 Resolved
Remove wire nuts from pump inboard of starboard M.E.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Lifesaving
Issued 20 July 1994 Resolved
Replace 1 ring buoy with 60' line and attach waterlight.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Lifesaving
Issued 20 July 1994 Resolved
Replace line to buoyant apparatus 18' each for light.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Electrical
Issued 20 July 1994 Resolved
Rewire 2 fans on upper deck with approved wire.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Electrical
Issued 20 July 1994 Resolved
Replace wire nuts owith crimp connection on forward starboard A/C pump.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Fire Fighting
Issued 21 July 1992 Resolved
Provide markings to show location of fire extinguishers; in plain view.
Condition: Unknown
Due 21 July 1992
Resolved 21 July 1992
Lifesaving
Issued 30 July 1991 Resolved
REPAIR MINOR PUNCTURES IN OUTER SKIN OF TWO 20 MAN BOUYANT APPARATUS USING SILICONE SEALANT.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Documentation
Issued 5 September 1990 Resolved
POST A SUITABLE NUMBER OF GARBAGE WARNINGS BOTH DECKS.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Documentation
Issued 5 September 1990 Resolved
PROVIDE A WRITTEN GARBAGE MANAGEMENT PLAN.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Lifesaving
Issued 5 September 1990 Resolved
PROVIDE LIFE FLOAT WATER LIGHT BRACKET.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Documentation
Issued 3 August 1990 Resolved
POST EMERG INSTR BOTH DECKS.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Navigation
Issued 3 August 1990 Resolved
INSTALL LOCKNUTS OR COTTER KEY - JOCKEY BAR.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Navigation
Issued 3 August 1990 Resolved
INSTALL FLATWASHERS PLYWOOD SIDE RUDDER STOCK BEARINGS.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Engineering
Issued 3 August 1990 Resolved
INSTALL METALLIC EXH HANGERS (SUBSTANTIAL).
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Accommodation/Occupational Safety
Issued 3 August 1990 Resolved
HARDWIRE A/C CONTROL CIRCUITS.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Accommodation/Occupational Safety
Issued 3 August 1990 Resolved
REPAIR LATCH - STBD FWD TOILET.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Engineering
Issued 3 August 1990 Resolved
INSTALL CHAFFING - ALL E/R HOSES.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Electrical
Issued 3 August 1990 Resolved
INSTALL DRIP SHIELD SWITCHBOARD REAR.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Lifesaving
Issued 3 August 1990 Resolved
PROVIDE 9 PERSON MIN BUOYANT APPARATUS. UNTIL COMPLETE, VESSEL IS LIMITED TO 160 TOTAL, 140 PASSENGERS.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Documentation
Issued 3 August 1990 Resolved
POST ORGINAL STABILITY LTR UPON RECEIPT.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Construction/Loadline
Issued 3 August 1990 Resolved
COMPLETE GLASSING ALL PVC BHD PENETRATIONS.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Construction/Loadline
Issued 3 August 1990 Resolved
INSTALL PVC PENETRATION - COKE MACH DRAIN.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Fire Fighting
Issued 3 August 1990 Resolved
PROVIDE 25' DISCH, 10' SUCTION HOSES - EMERG FIRE PUMP.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Lifesaving
Issued 3 August 1990 Resolved
PROVIDE 15 ADULT PFD'S. UNTIL COMPLETE VESSEL IS LIMITED TO 154 TOTAL, 134 PASSENGERS.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990

Casualty record · 4

2 September 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3049020
19 May 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6423430
29 June 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6732405
31 July 2021Routine · role: Involved in a Marine Casualty · activity 7276063
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record