Records from 2007 to 2026. Most recent: inspection, 25 March 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 May 2025
Resolved
Vessel missing 03 smoke flares.
Due 4 June 2025
Resolved 2 June 2025
Resolution: Flares provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 May 2025
Resolved
Rear doors in crews area on first deck do not latch or secure properly. Repair or replace as needed.
Due 2 June 2025
Resolved 2 June 2025
Resolution: Proper latches replaced on doors.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 May 2025
Resolved
Vessel Need emergency instructions posted at operating station.
Due 12 June 2025
Resolved 12 June 2025
Resolution: Emergency Instructions placed onbridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2025
Resolved
Life ring light need a non-corrosive clip at life ring.
Due 16 June 2025
Resolved 12 June 2025
Resolution: Clip provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2025
Resolved
Life ring light need a non-corrosive clip at life ring.
Due 13 June 2025
Resolved 12 June 2025
Resolution: Bracket provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2024
Resolved
Life ring needs new grab-lines and new stenciling
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2024
Resolved 18 June 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 May 2024
Resolved
Fire extinguishing system was inspected and is operational as per tech. However, system active light was extinguished. Needs an electrician.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2024
Resolved 30 May 2025
Resolution: Alarm fixed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2023
Resolved
Repair port side fuel shut off. Cable parted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Cable repaired and tested.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 September 2023
Resolved
Repair/ replaceport side engine room ventilation closure (damper).
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Damper closure tested. works sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2023
Resolved
Repair replace main deck door (fire escape) so that it opens properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Door repaired and tested.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 September 2023
Resolved
Repair hole in stbd side hull in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Repairs completed and water tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 September 2023
Resolved
Tighten contact on stbd Fireboy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 22 September 2023
Resolution: Contacts secure.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 October 2023
Resolved 30 May 2025
Resolution: License provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2023
Resolved
Provide FCC Safety Radio Certificate.
Due 15 October 2023
Resolved 30 May 2025
Resolution: Cert provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 September 2023
Resolved
Provide Coast Pilot, Light list and Tide Tables for Bridge.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Online pubs provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 September 2023
Resolved
Replace Emergency Broadcast Placard for Bridge.
Due 29 September 2023
Resolved 30 May 2025
Resolution: Placard provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2023
Resolved
Prove proper operation of Digital Selective Calling feature on VHF Radio.
Due 29 September 2023
Resolved 30 May 2025
Resolution: DSC tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 September 2023
Resolved
Repair Bilge Alarm light for stbd head.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Alarm light repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 September 2023
Resolved
Refresh “Casablanca” markings on life rings.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Markings replenished.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 15 September 2023
Resolved
Provide appropriate first aid kit.
Due 29 September 2023
Resolved 22 September 2023
Resolution: New first aid kit provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023
Resolved
All electrical splices need to be in appropriate electrical boxes.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Splices placed in proper junction boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 September 2023
Resolved
Provide bulbs or covers for all light bulb sockets,
Due 29 September 2023
Resolved 22 September 2023
Resolution: Proper bulbs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2023
Resolved
Tighten port battery terminals for generator.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Terminals tightened.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 September 2023
Resolved
Repair/ replace broken gauge on fire pump.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Gauge replaced and tested under pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2023
Resolved
Repair port engine room ground wire.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Ground wire reconnected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023
Resolved
Repair/ replace port main diesel engine exhaust pipe.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Pipe properly welded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 September 2023
Resolved
STBD HVAC room raw water valves need to be removed/ repaired/plugged.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Pipes capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2023
Resolved
Unwrap stbd main engine exhaust for inspection.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Exhaust inspected. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2023
Resolved
Tighten up engine mounting bolts so they have proper security.
Due 29 September 2023
Resolved 22 September 2023
Resolution: Longer hardware provided. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2023
Resolved
Repair replace flame screens in fuel tank vents. Will fix at drydock.
Due 29 September 2023
Resolved 30 May 2025
Resolution: Flame screens provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 September 2023
Resolved
Vessel missed it's Annual Certificate of Inspection window. Due date was 8/19/23.
Action required: 10 - Deficiency Rectified
Due 15 September 2023
Resolved 15 September 2023
Resolution: Annual inspection completed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 August 2021
Resolved
Received notification from vsl owner stating the CASABLANCA received damage from a grounding incident. Vessel is restricted from PAX carriage pending inspection of damage. Repairs, if required, will be made to the satisfaction of an attending CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2021
Resolved 1 September 2021
Resolution: Repairs complete. Sea trial conducted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 June 2021
Resolved
Current light list, tide table, and coast pilot not onboard during time of inspection. Ensure current nautical publications are onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: New publications acquired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Anti-strain clamp on junction box in port lazarette missing screw. Ensure anti-strain clamp is properly installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Installed Clamp
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 June 2021
Resolved
Could not provide FCC Safety Certificate and Bridge-to-Bridge certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 9 June 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Dead end wires found throughout the vessel. Remove all dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Electrician removed most dead-ended wires, however this will continue to be a work in progress.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Various electrical equipment/boxes missing covers. Ensure all electrical equipment/boxes have covers or guards to protect from shock.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Attended VSL. Verified SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2021
Resolved
Fire extinguishers required by COI missing from vessel. Ensure the vessel is equipped with proper amount of fire extinguishers as required by it's COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Extinguishers verified onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2021
Resolved
Life jackets are in the process of being replaced. Ensure the vessel is equipped with proper amount of lifejackets as required by it's COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Life jackets verified onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 June 2021
Resolved
Emergency exits on main deck not marked. Mark designated emergency exits on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR".
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Emergency Exits marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2021
Resolved
Temporary repair (putty) present on pipe underneath main deck. Conduct permanent repair on pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Optested/SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Various light sockets observed without bulbs. Ensure all sockets are installed with bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2021
Resolved
Two ring buoys found wasted/torn. Replace two ring buoys on upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Ring buoys replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 June 2021
Resolved
Unable to verify proper function of fixed firefighting shutdown/override and fixed fire detection. Prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 21 June 2021
Resolution: Fire servicing receipt provided.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 June 2021
Resolved
Vessel's master was unfamiliar with emergency fuel/vent shutoffs. Ensure crew receive training on use/function.
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: Training conducted during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2021
Resolved
Bilge valves not labeled for spaces served. Label valves to designate spaces served. Crew confusion over spaces served.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Valves labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2021
Resolved
Hot water tank in STBD lazarette wasted. Replace prior to use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Loose wiring on compressor in STBD lazarette. Repair/replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Attended VSL. Verified SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 June 2021
Resolved
Deck hatch on STBD bow leaking excessively. Repair/replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2021
Resolved 1 July 2021
Resolution: Removed debris from sealing surfaces and water tested w/ hose. SAT
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2021
Resolved
KAPOK work vests used by crew during man overboard drill found unserviceable. Replace with suitable life/work vests.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 21 June 2021
Resolution: New life jackets placed in service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 June 2021
Resolved
Various doors on deck house found not to be weathertight. Ensure all doors on the deck house are weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 9 June 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Various wire runs below deck supported with plastic ties. Ensure wire runs below deck accessible by the crew are installed with metallic supports. Ensure wire runs above doorways utilize metallic supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Old T does not require.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
Junction box in STBD engine room hanging. Affix junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2021
Resolved
Loose wire connections found on starter of STBD main engine. Tighten loose connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 1 July 2021
Resolution: Attended VSL. Verified SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 June 2021
Resolved
Generator solenoid in port engine room missing mounting screw. Install missing mounting screw.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2021
Resolved
4x4 Junction box appeared to have electrical burns/mold.
Open junction box to verify damage if any. Repair/replace as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 June 2021
Resolved
Emergency Egress door was unable to be easily opened in the event of Em Egress IAW 46cfr177.500(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2021
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 June 2020
Resolved
Ballast does not appear to comply with the provisions of the vessel's stability letter. Provide evidence to the attending marine inspector that the vessel's current ballast configuration complies with the vessel's stability letter.
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 16 July 2021
Resolution: Ballast issues resolved between navarc and MSC.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2020
Resolved
Electrical system appeared to have various changes including multi outlets, extension cords, splices, dead end wires, new pumps, lighting, appliances etc...Remove all unauthorized electrical additions. Ensure electrical system complies with original Coast Guard approved electrical plans.
Action required: 705 - Other - as specified
Due 31 July 2020
Resolved 8 July 2021
Resolution: Various electrical additions removed. Plans deferred to next DDX.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 June 2019
Resolved
Vessels flares were expired. Provide new flares.
Due 21 June 2019
Resolved 21 June 2019
Resolution: New flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 21 June 2019
Resolved
Vessel did not have a life jacket placard displayed. Provide placard.
Due 5 July 2019
Resolved 8 July 2021
Resolution: Attended VSL. Verified SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 August 2018
Resolved
The Certificate of Inspection was beyond it's validity dates when the vessel operated between July 30, 2018 and August 2, 2018. The 90 day waiver ended on July 29, 2018.
Due 2 August 2018
Resolved 2 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018
Resolved
Bilge piping in stbd side LAZ found disconnected. Re- solder pipe and test to satisfaction of attending MI.
Action required: 10 - Deficiency Rectified
Due 2 August 2018
Resolved 2 August 2018
Resolution: Section of piping was replaced and tested.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 August 2018
Resolved
Leak found in FF piping stbd side ER repair/replace section of piping and test.
Due 9 August 2018
Resolved 17 August 2018
Resolution: Leak properly repaired and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2018
Resolved
Weathered KAPOK PFD's found in poor condition with many no longer holding air. Submit replacement plan to the satisfaction of the Couast Guard.
Due 9 August 2018
Resolved 9 August 2018
Resolution: 90 PFD's have been replaced and final amount of KAPOKS will be replaced by next inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 August 2018
Resolved
Fuel shut off valve was unable to close completely. Repair the valve handle to ensure the valve fully closes.
Due 2 August 2018
Resolved 2 August 2018
Resolution: Valve repaired and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 August 2018
Resolved
Poor house keeping found on generator. Clean vents on the gen side of the unit.
Due 9 August 2018
Resolved 10 August 2018
Resolution: Gen set cleaned and verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2018
Resolved
Exposed wiring found on stbd side next to the sewage pump. Provide proper connection.
Due 9 August 2018
Resolved 10 August 2018
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 August 2018
Resolved
PA system does not operate on main deck. Ensure proper operation.
Due 3 August 2018
Resolved 3 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2018
Resolved
Missing indicator light for pre-engineered system on the bridge. Repair/Replace.
Due 9 August 2018
Resolved 17 August 2018
Engineering › Bilge Water Management System › Piping
Issued 4 May 2018
Resolved
Make repairs to bilge piping in LAZ.
Action required: 10 - Deficiency Rectified
Resolved 24 May 2018
Resolution: Section of piping was installed to the satisfaction of attending MI.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2017
Resolved
A valve with a garden hose was installed below the galley hatch (under sink). If the hose and connection are to remain, a check valve must be installed to ensure the system is unable to back flood the lazarette.
Due 30 August 2017
Resolved 11 June 2018
Resolution: Appeal denial from OCMI was handed down to the operator and def was resolved by removing the unauthorized fitting.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 August 2017
Resolved
Bilge high level alarm (audible) in tharboard side head found INOP. Ensure both visual and audible alarms work on the bridge.
Due 30 August 2017
Resolved 28 September 2017
Resolution: Bilge Alarm Tested Sst.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 August 2017
Resolved
The distribution panel in the galley was found with no cover. A cover must be installed.
Due 30 August 2017
Resolved 29 August 2017
Resolution: New cover has been installed.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2017
Resolved
A leak was found in the bilge piping appriximately 1.5' forward of the overboard on the transom. The piping is leaking at a union installed in the copper piping.
Due 30 August 2017
Resolved 5 September 2017
Resolution: New section of piping was soldered on and union was tightened. Tested bilge system with no leaks noted. SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 16 August 2017
Resolved
02 life rings were found unsurvicable must be replaced.
Due 30 August 2017
Resolved 29 August 2017
Resolution: New ring buoys have been provided on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2017
Resolved
An abandoned electrical box was found just above the hatch for the lazarette. Ensure wires are not live and remove box and dead ended wires.
Due 30 August 2017
Resolved 29 August 2017
Resolution: Abandoned box and wires have been removed.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2017
Resolved
Bilge piping valve at the pump port side in laz is leaking. Replace valve or valve parts to correct leak.
Due 30 August 2017
Resolved 5 September 2017
Resolution: New valve was installed. Tested system. SAT.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 August 2017
Resolved
No life line provided on any of the vessels ring buoys. Provide life line IAW 46CFR 180.70.
Due 30 August 2017
Resolved 5 September 2017
Resolution: 60 FT of line was provided with forward ring buoy. SAT.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 August 2017
Resolved
The vessel could not show proof of enrollment with a valid consortium for pre-employment or random drug testing.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Vessel provided all required documentation.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 August 2017
Resolved
The vessel has no means to collect and have available all documentation referring to the vessel's Drug and Alcohol testing program.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Vessel has provided all required documentation.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 16 August 2017
Resolved
The vessel was operating with crew members not listed on the current drug testing roster.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 16 August 2017