Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
37 - Simplified, Gross Ton
30 - Simplified, Net Ton
Maury page id
psix-34398
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
17 June 2026Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8405883
8 September 2025Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8229178
3 September 2025Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8226350
11 September 2024Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8001209
12 July 2024Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7964186
17 June 2024Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7937632
15 September 2023Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7793588
3 February 2023Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7631499
4 April 2022COI Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7428598
4 June 2020Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6973482
6 September 2018Initial Certification
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6534837
19 September 2017Industry Initiated Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6275321
(a) A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by 136.202.
The vessel owner/operator must schedule and complete the required annual inspection with the Coast Guard. Upon successful completion of the inspection, the COI must be revalidated to restore the vessel's compliance with 46 CFR 136.202. The vessel must not engage in commercial operations until these requirements are met.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 8 September 2025
Resolution: Annual Completed
Towing vessel record was incomplete. No record of towing gear.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2024Resolved
No audible or visual high water alarm was provided at the operating station. High water was monitored via a cellular alarm system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2024Resolved
Vessel's name and hailing port were not visbile on the transom.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2024
Resolved 11 September 2024
08 - Alarms › N/A - No Subsystem › General alarm
Issued 15 September 2023Resolved
General alarm in engine room is not labeled. Correct to the satisfaction of attending CG Marine inspector.
46 CFR 143.235
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2023
Resolved 21 September 2023
Resolution: Resolved based on objective evidence provided by operator.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 April 2022Resolved
Service fire detection system and provide a copy of the report to the Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2022
Resolved 13 May 2022
Resolution: Fire service technician supplied MI with a copy of the updated servicing report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2022Resolved
Approved life jackets were not on board. Provide approved life jackets, labeled, outfitted, and properly stowed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2022
Resolved 13 May 2022
Resolution: Vessel owner/operator replaced on board lifejackets with new Type 1 pfds.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 April 2022Resolved
Crew training was not conducted or documented. Provide and document required crew safety and navigation training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2022
Resolved 13 May 2022
Resolution: Vessels captain started to maintain a log documenting crew training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022Resolved
Repair or replace pressure relief valve on vessels boiler system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 13 May 2022
Resolution: Repaired SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2022Resolved
Install cover/insulator over exposed DC knife switch in engine room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 May 2022
Resolved 13 May 2022
Resolution: Vessel Owner/Operator installed cover over DC knife switch.
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. A small puncture was found on the outside of the hull leading to the starboard fuel tank. The vessel must safely make repairs to prevent any ingress of water.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2018
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 September 2018Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. The starboard side diesel fuel tank was leaking fuel onto the outside of the hull. The vessel must safely make repairs to prevent any further discharge of fuel.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2018