WILLAMETTE QUEEN

WILLAMETTE QUEEN is a 1990 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in August 2025, along with 81 deficiencies and 5 casualty investigations between 2008 and 2016.

Records from 2008 to 2025. Most recent: inspection, 28 August 2025.

Built
1990
Last inspected
28 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WBY5958
344144
Flag
UNITED STATES
Maury page id
psix-344144

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 62 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWASH-BUCKLER INC · NEWPORT, OR, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionCombination Types
Hull shapeShip
Hull configurationMonohull
Hailing portSALEM, OR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 24

28 August 2025 COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8214174
19 August 2025 Administrative Inspection · Drydock Extension
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8213685
6 February 2025 Internal Structural Exam · Drydock Extension · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8076365
9 September 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7999198
7 March 2024 Internal Structural Exam · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7875777
27 September 2023 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7799572
15 September 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7792256
14 September 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7785244
25 May 2023 In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7701676
14 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7577618
28 September 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7568236
20 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7552980
2 September 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7302173
9 September 2020 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7053551
4 September 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6802658
28 March 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6653837
19 January 2019 Hull Examination · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6613315
5 September 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6525286
9 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6304201
23 August 2017 Annual Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6304165
12 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6056417
8 September 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5994461
4 April 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5859667
3 April 2016 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5848078

Deficiency record · 81

09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 28 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified 04 electrical cords which had multiple extensions run in series, and lighting system was spliced into new outlet. Correct to satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 5 September 2025
Resolution: Operator provided photos showing satisfactory correction of electrcial issues. See attached photographs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 August 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit was missing analgesic medicine, antiseptic preparations, and burn preparations. Add missing items to be in compliance with the requirements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 2 September 2025
Resolution: Operator provided photos verifying items were added and expiration date was valid.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 August 2025 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Operator did not have license present on vessel. Maintain and keep credential onboard while operating vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Operator provided valid MMC for second captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2025 Resolved
(a) S and L. Except as further modified in this section, where items of lifesaving equipment are not required, but are installed, such equipment and its installation shall meet the requirements of this part. Starboard side extra life buoy retroflection tape and line was wasted. Replace to comply with this requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Lifebouy taken out of service, in excess of the number required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2024 Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Vessel owner failed to provide records of compliance with drug and alcohol program. Vessel owner is to provide proof of pre-employment drug and alcohol testing for all required crew members and enrollment into random chemical testing program for dangerous drugs to the satisfaction of the attending MI.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 September 2024
Resolution: MI recieved chemical test results for crew sent from consortium via email.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 September 2024 Resolved
The construction and arrangment of a vessel must allow the safe operation of the vessel IAW the terms of its COI. MI identified a soft spot on the second deck port side of the vessel. Vessel owner is to strengthen the deck in the location of the soft spot and provide evidence of the fix to a MI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 9 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2024 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be in compliance with 177.405(b) and 177.970 of this chapter. MI identified missing insulation on the turbo charger portion of the exhaust system. Vessel owner is to porperly insulate exhaust exhaust system an prove proper installation to a MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 4 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 September 2024 Resolved
All exposed hazard, such as gears or rotating machinery, must be properly protected by cover, guard, or rail. MI identified missing guards on ventilation fan belts and on fire pump. Install guards over fan belts and on the fire pump and provide proof to a MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 4 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 9 September 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the normally unmanned spaces. MI identified that the vessel's visual indication (light bulb) for the high water level at the operation station was inoperable. Vessel owner is to replace the high water level light bulb and prove proper operation to a MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 9 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 September 2024 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. MI identified a battery in the engine room not placed in a permanetly mounted tray. Additionally, the battery must have a means to protect it from exposure of water splash or spray. Vessel owner is to secure the battery and install a cover to protect it from water splash or spray and provide proof to a MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 9 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2023 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. PORT stern wheel had 03 paddles that had portions of deteriorated/rotted wood to the point of necessitating replacement. STBD stern wheel had 01 inboard spoke that had a portion of deteriorated wood the point of necessitating replacement. Replace the 03 identified paddles and 01 spoke to the satisfaction of the attending marine inspector. 46 CFR(96) 182.05-1 / 46 CFR 182.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 27 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2023 Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline on ring life buoy showed significant deterioration. Replace to satisfaction of attending marine inspector. 46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 27 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. STBD quarter on 2nd Deck had daisy chained electrical cords for lighting equipment. Remove daisy chained equipment to satisfaction of attending marine inspector. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 27 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2022 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. STBD stern wheel had 05 inboard and 07 outboard spokes that had deteriorated/ rotted to the point of necessitating replacement. STBD Stern wheel had an additional 06 paddles that were deteriorated past the point of necessitating replacement. Replace the 12 identified spokes and 06 paddles to the satisfaction of the attending marine inspector. 46 CFR(96) 182.05-1 / 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2022
Resolved 28 September 2022
Resolution: VSL has replaced the 12 identified spokes and 06 paddles; All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2022 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Per COI vsl is required to carry 109 adult life jackets. Upon inspection vessel only had 108 serviceable life-jackets. Passenger count is reduced by 01 until full compliment of life jackets are onboard. 46 CFR(96) 180.25-5 / 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2022
Resolved 3 October 2022
Resolution: Vessel master procured a new type 1 PFD
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 September 2022 Resolved
At each initial and subsequent inspection for certification... the inspector shall view and inspect all watertight closures in the hull decks and bulkheads. Observed non watertight through hull fitting in aft port side of the engine room. Install/replace missing fitting. 46 CFR(96) 176.25-5
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2022
Resolved 28 September 2022
Resolution: Fitting has been replaced; All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2022 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. Port stern wheel had 03 inboard and 01 outboard spokes that had deteriorated/ rotted to the point of necessitating replacement. Port Stern wheel had an additional 01 paddles that were deteriorated past the point of necessitating replacement. Replace the 12 identified spokes and 06 paddles to the satisfaction of the attending marine inspector. 46 CFR(94) 182.05-1 / 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 28 September 2022
Resolution: VSL has replaced the the 04 identified spokes and 01 paddles; All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2022 Resolved
Vessels not limited to daytime operations shall be provided with an approved waterlight. Waterlight on life ring on main deck was missing. Vessel is restricted to daytime operations until replaced. 46 CFR(96) 180.30-5(b) 46 CFR 180.70(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 28 September 2022
Resolution: Waterlight was replaced; All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2022 Resolved
The ring life buoy must be of an approved type. Constructed in accordance with subpart 16.050 of this chapter. The ring life buoy located on the 2nd deck port side was no longer serviceable. Replace. 46 CFR(96) 180.30-1 / 46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 28 September 2022
Resolution: VSL replaced ring life buoy; All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical wires located above the light fixture in the dish washing area were exposed posing hazard to crew. Repair to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Cables were terminated in approved box; All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. STBD stairway lights leading to the top deck were daisy chained with fans and heating equipment. Remove daisy chained equipment to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Daisy chained equipment was removed; All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Port quarter weather deck overhead had multiple daisy chained non outdoor extension cables connecting to outdoor lighting. Remove daisy chained cables and provide plan to replace current arrangement. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 14 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 02 unapproved multi outlet plugs installed in galley area. Remove to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Unauthorized appliances were removed; All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Drapes in the second deck dining area are touching the lighting fixtures creating a potential for fire. Remove drapes to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Drapes were relocated to avoid fire hazards; All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2022 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway fr the first time on a particular vessel and at least once every three months as to the duties that the crew member is expected to conduct... Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have logs of training conducted in the past 07 months. Provide record of training to satisfaction of attending marine inspector. 46 CFR 185.420
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Vessel was given logbook to imrpove recordkeeping. Drills were conducted while inspectors were onboard, attending marine inspector witnessed recording both fire and man overboard drills; All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise document for review by the Coast Guard upon request. Vessel did not provide drill log for previous 07 months, last record of drills was Feb 2022. Provide record of drills to satisfaction of attending marine inspector. 46 CFR 185.520
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Vessel was given logbook to imrpove recordkeeping. Drills were conducted while inspectors were onboard, attending marine inspector witnessed recording both fire and man overboard drills; All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2021 Resolved
SC01:Portable fire extinguishers must be located so that they are readily accessible from the space being protected and the installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The brackets for the fire extinguishers located in the bar area and near the piano were not installed fixed to the bulkhead. Install brackets to ensure they are fixed to the bulkhead to prevent them from rolling to satisfaction of Officer in Charge, Marine Inspection (OCMI). 46 CFR 181.520
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2021
Resolved 3 September 2021
Resolution: Fire extinguishers were properly secured.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 2 September 2021 Resolved
SC02: At every vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and in satisfactory condition. The floor boards on the bow ramp used for recovering MOB, was found deteriorated. Replace with new floor boards of adequate strength to the satisfaction of the OCMI. 46CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2021
Resolved 3 September 2021
Resolution: The floorboards for the bow ramp were replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 September 2021 Resolved
SC03: A fixed CO2 fire extinguishing system shall be installed to protect the paint room on all vessels having such spaces. The following flammable liquids were found in the void containing the bow thruster up forward: paint and paint thinner canisters. Remove all flammable materials from void and place in anapproved space/enclosure to satisfaction of the OCMI. 46 CFR 181.20-1(a)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2021
Resolved 3 September 2021
Resolution: The flammable liquids were removed from the void space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
SC04: Remove twist-on wire connectors used for making connections to a lighting fixture in the space left of the engine room door; use proper termination blocks with "captive" type connectors to satisfaction of OCMI. 46 CFR 183.410
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 15 September 2021
Resolution: The light and wiring was removed from the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 2 September 2021 Resolved
SC05: At each inspection for certification and every other vessel inspection all observed unsafe practices and other hazardous situations must be corrected. The ladder leading to the sewage compartment and the ladder leading to the top deck are not properly secured and present a danger to crew. Repair ladders to the satisfaction of the OCMI. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 15 September 2021
Resolution: Ladders were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
SC06: Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlets and light covers in the following locations were found missing/broken and exposing electrical wires or ignition source:Emergency light in bar area, outlet on bow ramp, engine room outlet, engine room light, lower deck on starboard side bulkhead, upper deck on port side bulkhead, and outlet near aft refrigerator. Repair to satisfaction of OCMI. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 19 October 2021
Resolution: Electrical outlets appropriately protected.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 September 2021 Resolved
SC07: A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. The first aid kit contained expired contents. Replace expired contents in accordance with the regulations and to satisfaction of the OCMI. 46 CFR 184.710
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Replaced expired items in first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 September 2021 Resolved
SC08: The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. An awning was installed on the bow and stern without submitting a proposal to local OCMI for approval. The awning on the bow shall be removed as necessary to ensure it does not impede the lowering of the bow ramp to the satisfaction of the OCMI. 46 CFR 176.700
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Installed longer bolt for winch that allows proper operation with present awning.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 September 2021 Resolved
SC09: The owner, managing operator, or a qualified servicing facility as applicable must conduct the following tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 as amended: monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Portable fire extinguishers onboard the vessel are not inspected and maintained in accordance with required NFPA monthly inspections. Conduct and log monthly inspection/maintenance of portable fire extinguishers in accordance with NFPA 10 to the satisfaction of the OCMI. 46 CFR 176.810(b)(1)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Operator implented inspection schedule and log of monthly maintenance IAW NFPA 10.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 September 2021 Resolved
SC10: Except for a storage battery used in a rescue boat, each battery without an expiration date indicated on it or for which the owner or managing operator does not have a record of the expiration date, used in an item of lifesaving equipment, must be replaced during the annual inspection. Vessel representative did not have record of the expiration date of the ring life buoy waterlight battery. Replace waterlight battery in accordance with manufacturer’s instructions and to the satisfaction of the OCMI. 46 CFR 185.726(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 19 October 2021
Resolution: Replaced waterlight in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 September 2021 Resolved
SC11: At each inspection for certification and every other vessel inspection all observed unsafe practices and other hazardous situations must be corrected. The deck rail/stanchion on the upper deck near the port quarter and the first stanchion on the starboard side of the bow are loose and present a hazardous situation to passengers. Propose repair plan and repair the deck rail/stanchions to the satisfaction of the OCMI. 46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Installed angle iron to secure stanchions satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 September 2021 Resolved
SC12: Propulsion Machinery must be suitable in type and design capable of operating under load. One paddle wheel spoke, portside and inboard, were found rotted at the connection to the hub. Renew the one rotted paddle wheel spoke using suitable material to the satisfaction of the OCMI. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Replaced rotted spoke in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
SC13: Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The stairway lights leading to the top deck were daisy chained with fans and heating equipment. Remove daisy chained equipment to satisfaction of the OCMI. 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 September 2021 Resolved
SC13: The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate the recovery of persons who have fallen overboard. Conducted man overboard drill; crew failed the drill due to lack of announcements on PA system and proper communication with passengers. The second man overboard drill was satisfactory. 46 CFR 185.520(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2020 Resolved
Piping for vital systems over 150psig must be inspected in accordance with ANSI B 31.1. Small hydraulic oil leak discovered on the middle pump pressure gauge located on the aft bulkhead of the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 7 October 2021
Resolution: Pressure gauge replaced satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020 Resolved
Lighting Fixtures. Each lighting fixture must be fixed. lighting fixture on the port bulkhead of the changing room was found hanging by its power cable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 7 October 2021
Resolution: Lighting fixture removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020 Resolved
Cable and wiring requirements. Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Fan installed in the starboard aft overhead of the engine room had a open junction box on the motor. Power cable was non approved type and was plugged into an outlet. The fan not have a disconnect switch. Hard wire the fan using approved cable, switch, and provide a cover for the junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 7 October 2021
Resolution: Fan removed from engine room.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The port side damper leading to the engine room was broken and inoperable. Ensure damper is renewed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: Damper renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
Each life jacket kept in a stowage container must be readily available. The PFDs up forward were not readily available due to wires obstructing access. Ensure PFDs are not obstructed by wires and are readily available for immediate use.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: Wires were secured satisfactory to bottom of cabinet, no longer obstructing life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The adult and child pfds were not marked and separated. Ensure adult and child pfds are marked and separated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: Adult and child lifejackets were separated and properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. The stowage spaces for PFDs, up forward and astern, were not marked. Clearly mark all stowage spaces for PFDs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: PFD's were clearly marked with size and number in their correct locations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2019 Resolved
Cable and wire for power and lighting circuits must meet one of the following in 46 CFR 183.40(d). The cables up forward near the Life Jacket stowage area was not an approved type of cable. Renew cable IAW 46 CFR 183.40(d).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 15 October 2019
Resolution: Cable replaced with approved UL listed Boat cable
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2019 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. A small battery installation must not be in a closet, storeroom or similar space. The battery cover in the engine room was unable to close and protect the batteries from falling objects. Ensure batteries are are protected from falling objects.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 6 September 2019
Resolution: Battery cover was replaced and secured satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 September 2019 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The lighting fixture junction box located in the bar area was hanging and not properly secured. Install lighting fixture junction box IAW the manufacturer’s recommendation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 6 September 2019
Resolution: Lighting junction box was secured satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 September 2019 Resolved
High pressure gas storage cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. The cylinder in the bar area was not secured. Ensure cylinder is properly secured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: CO2 bottle was properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2019 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. 9 Paddle wheel spokes were found rotted at the connection to the hub. Renew all 9 rotted paddle wheel spokes using suitable material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 15 October 2019
Resolution: Wasted spokes were replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 March 2019 Resolved
Vessel must crop and renew extensive wood rot was found in port stern thruster room
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 28 March 2019
Resolution: All rotted wood has been cropped and renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2019 Resolved
Vessel must install three (2A) portable fire extinguishers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2019
Resolution: Vessel installed and mounted 3 (2A) portable fire extinguishers.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 January 2019 Resolved
Vessel must repair port side longitudinal frames and bilge strake are fractured in the amidship compartment underneath the galley.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: Hull damage from bridge allision cropped out and repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 January 2019 Resolved
Vessel must submit repair proposal for damage from bridge allision
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2018 Resolved
Replace cracked hydraulic hose on starboard paddle drive motor.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2018
Resolved 6 September 2018
Resolution: Replaced cracked hose with new hose
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018 Resolved
Provide sewage disposal receipts.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 6 September 2018
Resolution: Owner provided receipts from Carl's Septic Tank Cleaning Inc.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 September 2018 Resolved
Repair aft 3 stantions on port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2018
Resolved 19 September 2018
Resolution: All three stantions were repaired and reglassed/tabbed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2018 Resolved
Repair starboard linear steering ram.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2018
Resolved 6 September 2018
Resolution: Repaired leakin steering ram.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2018 Resolved
Replace rotted spokes and paddles on port and starboard paddle wheels
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 19 September 2018
Resolution: replaced all rotted spokes and paddles.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 September 2018 Resolved
Replace missing non-combustible insulation in engine room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 19 September 2018
Resolution: Repaired engine room hath and added new insulation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018 Resolved
Provide proof of enrollment in a DAPI program for all crewmembers
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 6 September 2018
Resolution: Owners provided proper documentation for crewmwembers enrolled in a DAPI program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 August 2017 Resolved
Provide either a 1st Aid Kit approved under 46 CFR 160.041, or a kit with the equivalent contents. The 1st Aid Kit must be stowed in a properly labeled, watertight container.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 8 November 2017
Resolution: See narrative.
Documentation › Logs/Records › Drug Test Records
Issued 23 August 2017 Resolved
Provide proof of enrollment in a DAPI program for all crewmembers working aboard the vessel in a safety sensitive position.
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 25 August 2017
Resolution: [name withheld] provided documentation as requested (via fax).
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 August 2017 Resolved
Replace alcohol test detectors/swabs with expired dates.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Resolution: See narrative. (New alcohol testing devices expire in January of 2018.)
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2017 Resolved
Replace retro-reflective tape on ring/life buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Engineering › Non-conventional Propulsion/Steering › Fixed-Pitch Propeller (Azipod)
Issued 23 August 2017 Resolved
Replace missing hardware on paddle boards and spokes. Repair loose spokes on the starboard side of the paddle wheel. (Was not able to find spokes/paddle boards under the "Components" drop-down list for non-conventional propulsion types.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 August 2017 Resolved
Repair and/or replace deck rail stantion at the port-side embarkation station. Current stantion is not properly affixed to the deck at its base.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 August 2017 Resolved
Provide fire servicing report for required portable fire extinguishers and the fixed CO2 system in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Resolution: Completed on July 27th, 2017, by Instant Fire Protection Co.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2017 Resolved
Remove/replace spliced wires in void compartments. Each connection to a conductor or terminal part should be made within an enclosure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2017 Resolved
Remove twist-on wire connectors used for making connections in the electrical wiring system; use proper termination blocks with "captive" type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 23 August 2017 Resolved
Replace modular smoke detecting units with ones that are UL 217 approved and which contain an independent power source.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Engineering › Bilge Water Management System › Not Operational
Issued 23 August 2017 Resolved
Repair electrical bilge pumps and high-level alarms switches in void compartments.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2017
Resolved 6 September 2017
Resolution: Fixed during the course of the inspection.
Fire Fighting › Fire Main › Material
Issued 23 August 2017 Resolved
Repair sections of fire main piping (CUNI) where electrolysis has damaged the copper nickel piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 8 November 2017
Communications › Alarms/Indicators › General Alarm
Issued 23 August 2017 Resolved
Prove proper operation of the high temperature alarm for the wet exhaust system. Either an audible or visual alarm is required.
Condition: Improper/Lack of Maintenance
Due 23 September 2017
Resolved 6 September 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2016 Resolved
Place guards over kitchen (galley) lighting (02). 46CFR183.410
Action required: 705 - Other - as specified
Due 8 October 2016
Resolved 30 September 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 September 2016 Resolved
Proivde up to date nav rules. 46CFR184.420
Action required: 705 - Other - as specified
Due 8 October 2016
Resolved 30 September 2016
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 September 2016 Resolved
Provide valid license for vessel's captain. 46CFR185.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 2 May 2016 Resolved
Turbocharger lagging was oil soaked from engine casualty and began to smolder when the turbo reached operating temperature.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 3 May 2016
Resolution: Turbocharger lagging was replaced with new lagging, and functionality was verified with engine operation test.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 3 April 2016 Resolved
Engine suffered a total loss of lube oil and jacket water, causing the engine to seize.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 2 May 2016
Resolution: Engine was totally rebuilt, all auxiliary machinery and components were reattached and functional, engine was broken in per the manufacturer's instructions, technician report was provided verifying repairs, sea trials were conducted, all sat.

Casualty record · 5

19 January 2008Routine · role: Involved in a Marine Casualty · activity 3170468
18 November 2010Routine · role: Involved in a Marine Casualty · activity 3901176
13 April 2011Routine · role: Involved in a Marine Casualty · activity 3985848
9 June 2012Routine · role: Involved in a Marine Casualty · activity 4341257
4 April 2016Routine · role: Involved in a Marine Casualty · activity 5859667
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.