WILLAMETTE QUEEN

WILLAMETTE QUEEN is a 1990 passenger vessel (inspected). The Coast Guard has recorded 123 inspections since 1990, most recently in August 2025, along with 390 deficiencies and 5 casualty investigations between 2008 and 2016.

Records from 1990 to 2025. Most recent: inspection, 28 August 2025.

Built
1990
Last inspected
28 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBY5958
344144
Flag
UNITED STATES
—
Maury page id
psix-344144

Inspections, by type

…with no type recorded21
Years with a record 35 calendar years (1990–2025)
The 123 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 62 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWASH-BUCKLER INC · NEWPORT, OR, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionCombination Types
Hull shapeShip
Hull configurationMonohull
Hailing portSALEM, OR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PITT BULL Towing Vessel · MISLE 942565 · 19 January 2008 · activity 3170468

Inspection history · 123

28 August 2025 COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8214174
19 August 2025 Administrative Inspection · Drydock Extension
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8213685
6 February 2025 Internal Structural Exam · Drydock Extension · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8076365
9 September 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7999198
7 March 2024 Internal Structural Exam · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7875777
27 September 2023 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7799572
15 September 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7792256
14 September 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7785244
25 May 2023 In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7701676
14 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7577618
28 September 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7568236
20 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7552980
2 September 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7302173
9 September 2020 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7053551
4 September 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6802658
28 March 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6653837
19 January 2019 Hull Examination · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6613315
5 September 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6525286
9 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6304201
23 August 2017 Annual Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6304165
12 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6056417
8 September 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5994461
4 April 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5859667
3 April 2016 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5848078
12 November 2015 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5773092
12 November 2015 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5773389
8 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5746347
31 July 2015 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5203770
13 May 2014 Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4857962
26 March 2014 In-Service Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4815581
19 July 2012 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4384223
11 June 2012 Deficiency Check · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4315210
9 June 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4341257
9 May 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4321672
26 January 2012 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4220078
21 December 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4211630
9 December 2011 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4205332
8 December 2011 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4204322
8 July 2011 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 4082865
28 January 2011 Damage Survey · Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3892348
18 November 2010 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 3901176
22 March 2010 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3694676
26 February 2010 Hull Examination · Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3674697
28 January 2010 Excursion Permit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3673307
6 January 2010 In-Service Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3659877
22 January 2009 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3398310
9 January 2009 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3391479
10 November 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3355169
19 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3170468
18 January 2008 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3130891
11 December 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3113410
29 October 2007 Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3082357
14 May 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2930451
4 January 2007 In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2849559
30 October 2006 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2782096
28 November 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2531105
28 November 2005 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2681643
1 September 2005 Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2491826
23 June 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2400463
10 January 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2270602
7 December 2004 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2247095
21 October 2004 Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2225431
27 July 2004 In-Service Inspection · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2147895
22 July 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2149122
19 May 2004 Quarterly Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2072324
9 February 2004 Quarterly Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1988952
15 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1942724
7 November 2003 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1957495
2 November 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2047691
4 August 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1867367
30 July 2003 Deficiency Check · In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2008791
29 July 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1860962
23 June 2003 In-Service Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1814433
4 June 2003 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1810444
30 May 2003 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1807925
23 May 2003 In-Service Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1802807
23 May 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1805026
20 March 2003 In-Service Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1757467
3 February 2003 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1735983
5 November 2002 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1700921
25 June 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1636411
22 February 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1488442
24 January 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1481059
5 November 2001 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382467
13 April 2001 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1067402
7 April 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 100050
16 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1399445
15 September 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 69857
29 October 1999 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1418619
5 October 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 788563
29 July 1999 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1442874
12 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 130737
8 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1360990
17 June 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 882491
19 April 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369128
12 April 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 788841
24 March 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1113405
24 November 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1404647
21 October 1998 Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1450213
19 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 68812
19 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1469522
30 April 1998 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 789780
8 April 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 213149
19 March 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 787138
3 March 1998 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1457543
8 October 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428841
9 October 1996 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1355975
6 November 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1409393
17 November 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 868410
9 November 1994 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1367214
15 September 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407370
14 September 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 121942
31 May 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 860768
22 March 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407287
25 October 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1134471
13 October 1993 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407216
29 June 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 960918
11 May 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 949688
15 January 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 957370
19 June 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 915745
22 May 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1323662
10 May 1990 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1321246
3 April 1990 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1013897

Deficiency record · 390

09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 28 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified 04 electrical cords which had multiple extensions run in series, and lighting system was spliced into new outlet. Correct to satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2025
Resolved 5 September 2025
Resolution: Operator provided photos showing satisfactory correction of electrcial issues. See attached photographs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 August 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit was missing analgesic medicine, antiseptic preparations, and burn preparations. Add missing items to be in compliance with the requirements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 2 September 2025
Resolution: Operator provided photos verifying items were added and expiration date was valid.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 August 2025 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Operator did not have license present on vessel. Maintain and keep credential onboard while operating vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Operator provided valid MMC for second captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2025 Resolved
(a) S and L. Except as further modified in this section, where items of lifesaving equipment are not required, but are installed, such equipment and its installation shall meet the requirements of this part. Starboard side extra life buoy retroflection tape and line was wasted. Replace to comply with this requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Lifebouy taken out of service, in excess of the number required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2024 Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Vessel owner failed to provide records of compliance with drug and alcohol program. Vessel owner is to provide proof of pre-employment drug and alcohol testing for all required crew members and enrollment into random chemical testing program for dangerous drugs to the satisfaction of the attending MI.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 September 2024
Resolution: MI recieved chemical test results for crew sent from consortium via email.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 September 2024 Resolved
The construction and arrangment of a vessel must allow the safe operation of the vessel IAW the terms of its COI. MI identified a soft spot on the second deck port side of the vessel. Vessel owner is to strengthen the deck in the location of the soft spot and provide evidence of the fix to a MI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 9 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2024 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be in compliance with 177.405(b) and 177.970 of this chapter. MI identified missing insulation on the turbo charger portion of the exhaust system. Vessel owner is to porperly insulate exhaust exhaust system an prove proper installation to a MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 4 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 September 2024 Resolved
All exposed hazard, such as gears or rotating machinery, must be properly protected by cover, guard, or rail. MI identified missing guards on ventilation fan belts and on fire pump. Install guards over fan belts and on the fire pump and provide proof to a MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 4 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 9 September 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the normally unmanned spaces. MI identified that the vessel's visual indication (light bulb) for the high water level at the operation station was inoperable. Vessel owner is to replace the high water level light bulb and prove proper operation to a MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 9 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 September 2024 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. MI identified a battery in the engine room not placed in a permanetly mounted tray. Additionally, the battery must have a means to protect it from exposure of water splash or spray. Vessel owner is to secure the battery and install a cover to protect it from water splash or spray and provide proof to a MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 9 October 2024
Resolution: Provided photo of effective repairs to MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2023 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. PORT stern wheel had 03 paddles that had portions of deteriorated/rotted wood to the point of necessitating replacement. STBD stern wheel had 01 inboard spoke that had a portion of deteriorated wood the point of necessitating replacement. Replace the 03 identified paddles and 01 spoke to the satisfaction of the attending marine inspector. 46 CFR(96) 182.05-1 / 46 CFR 182.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 27 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2023 Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline on ring life buoy showed significant deterioration. Replace to satisfaction of attending marine inspector. 46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 27 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. STBD quarter on 2nd Deck had daisy chained electrical cords for lighting equipment. Remove daisy chained equipment to satisfaction of attending marine inspector. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 27 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2022 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. STBD stern wheel had 05 inboard and 07 outboard spokes that had deteriorated/ rotted to the point of necessitating replacement. STBD Stern wheel had an additional 06 paddles that were deteriorated past the point of necessitating replacement. Replace the 12 identified spokes and 06 paddles to the satisfaction of the attending marine inspector. 46 CFR(96) 182.05-1 / 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2022
Resolved 28 September 2022
Resolution: VSL has replaced the 12 identified spokes and 06 paddles; All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2022 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Per COI vsl is required to carry 109 adult life jackets. Upon inspection vessel only had 108 serviceable life-jackets. Passenger count is reduced by 01 until full compliment of life jackets are onboard. 46 CFR(96) 180.25-5 / 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2022
Resolved 3 October 2022
Resolution: Vessel master procured a new type 1 PFD
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 September 2022 Resolved
At each initial and subsequent inspection for certification... the inspector shall view and inspect all watertight closures in the hull decks and bulkheads. Observed non watertight through hull fitting in aft port side of the engine room. Install/replace missing fitting. 46 CFR(96) 176.25-5
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2022
Resolved 28 September 2022
Resolution: Fitting has been replaced; All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2022 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. Port stern wheel had 03 inboard and 01 outboard spokes that had deteriorated/ rotted to the point of necessitating replacement. Port Stern wheel had an additional 01 paddles that were deteriorated past the point of necessitating replacement. Replace the 12 identified spokes and 06 paddles to the satisfaction of the attending marine inspector. 46 CFR(94) 182.05-1 / 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 28 September 2022
Resolution: VSL has replaced the the 04 identified spokes and 01 paddles; All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2022 Resolved
Vessels not limited to daytime operations shall be provided with an approved waterlight. Waterlight on life ring on main deck was missing. Vessel is restricted to daytime operations until replaced. 46 CFR(96) 180.30-5(b) 46 CFR 180.70(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 28 September 2022
Resolution: Waterlight was replaced; All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2022 Resolved
The ring life buoy must be of an approved type. Constructed in accordance with subpart 16.050 of this chapter. The ring life buoy located on the 2nd deck port side was no longer serviceable. Replace. 46 CFR(96) 180.30-1 / 46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 28 September 2022
Resolution: VSL replaced ring life buoy; All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical wires located above the light fixture in the dish washing area were exposed posing hazard to crew. Repair to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Cables were terminated in approved box; All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. STBD stairway lights leading to the top deck were daisy chained with fans and heating equipment. Remove daisy chained equipment to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Daisy chained equipment was removed; All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Port quarter weather deck overhead had multiple daisy chained non outdoor extension cables connecting to outdoor lighting. Remove daisy chained cables and provide plan to replace current arrangement. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 14 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 02 unapproved multi outlet plugs installed in galley area. Remove to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Unauthorized appliances were removed; All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Drapes in the second deck dining area are touching the lighting fixtures creating a potential for fire. Remove drapes to satisfaction of attending marine inspector. 46 CFR(96) 183.01-5 / 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Drapes were relocated to avoid fire hazards; All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2022 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway fr the first time on a particular vessel and at least once every three months as to the duties that the crew member is expected to conduct... Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have logs of training conducted in the past 07 months. Provide record of training to satisfaction of attending marine inspector. 46 CFR 185.420
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Vessel was given logbook to imrpove recordkeeping. Drills were conducted while inspectors were onboard, attending marine inspector witnessed recording both fire and man overboard drills; All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise document for review by the Coast Guard upon request. Vessel did not provide drill log for previous 07 months, last record of drills was Feb 2022. Provide record of drills to satisfaction of attending marine inspector. 46 CFR 185.520
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 28 September 2022
Resolution: Vessel was given logbook to imrpove recordkeeping. Drills were conducted while inspectors were onboard, attending marine inspector witnessed recording both fire and man overboard drills; All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2021 Resolved
SC01:Portable fire extinguishers must be located so that they are readily accessible from the space being protected and the installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The brackets for the fire extinguishers located in the bar area and near the piano were not installed fixed to the bulkhead. Install brackets to ensure they are fixed to the bulkhead to prevent them from rolling to satisfaction of Officer in Charge, Marine Inspection (OCMI). 46 CFR 181.520
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2021
Resolved 3 September 2021
Resolution: Fire extinguishers were properly secured.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 2 September 2021 Resolved
SC02: At every vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and in satisfactory condition. The floor boards on the bow ramp used for recovering MOB, was found deteriorated. Replace with new floor boards of adequate strength to the satisfaction of the OCMI. 46CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2021
Resolved 3 September 2021
Resolution: The floorboards for the bow ramp were replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 September 2021 Resolved
SC03: A fixed CO2 fire extinguishing system shall be installed to protect the paint room on all vessels having such spaces. The following flammable liquids were found in the void containing the bow thruster up forward: paint and paint thinner canisters. Remove all flammable materials from void and place in anapproved space/enclosure to satisfaction of the OCMI. 46 CFR 181.20-1(a)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2021
Resolved 3 September 2021
Resolution: The flammable liquids were removed from the void space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
SC04: Remove twist-on wire connectors used for making connections to a lighting fixture in the space left of the engine room door; use proper termination blocks with "captive" type connectors to satisfaction of OCMI. 46 CFR 183.410
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 15 September 2021
Resolution: The light and wiring was removed from the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 2 September 2021 Resolved
SC05: At each inspection for certification and every other vessel inspection all observed unsafe practices and other hazardous situations must be corrected. The ladder leading to the sewage compartment and the ladder leading to the top deck are not properly secured and present a danger to crew. Repair ladders to the satisfaction of the OCMI. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 15 September 2021
Resolution: Ladders were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
SC06: Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlets and light covers in the following locations were found missing/broken and exposing electrical wires or ignition source:Emergency light in bar area, outlet on bow ramp, engine room outlet, engine room light, lower deck on starboard side bulkhead, upper deck on port side bulkhead, and outlet near aft refrigerator. Repair to satisfaction of OCMI. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 19 October 2021
Resolution: Electrical outlets appropriately protected.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 September 2021 Resolved
SC07: A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. The first aid kit contained expired contents. Replace expired contents in accordance with the regulations and to satisfaction of the OCMI. 46 CFR 184.710
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Replaced expired items in first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 September 2021 Resolved
SC08: The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. An awning was installed on the bow and stern without submitting a proposal to local OCMI for approval. The awning on the bow shall be removed as necessary to ensure it does not impede the lowering of the bow ramp to the satisfaction of the OCMI. 46 CFR 176.700
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Installed longer bolt for winch that allows proper operation with present awning.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 September 2021 Resolved
SC09: The owner, managing operator, or a qualified servicing facility as applicable must conduct the following tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 as amended: monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Portable fire extinguishers onboard the vessel are not inspected and maintained in accordance with required NFPA monthly inspections. Conduct and log monthly inspection/maintenance of portable fire extinguishers in accordance with NFPA 10 to the satisfaction of the OCMI. 46 CFR 176.810(b)(1)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Operator implented inspection schedule and log of monthly maintenance IAW NFPA 10.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 September 2021 Resolved
SC10: Except for a storage battery used in a rescue boat, each battery without an expiration date indicated on it or for which the owner or managing operator does not have a record of the expiration date, used in an item of lifesaving equipment, must be replaced during the annual inspection. Vessel representative did not have record of the expiration date of the ring life buoy waterlight battery. Replace waterlight battery in accordance with manufacturer’s instructions and to the satisfaction of the OCMI. 46 CFR 185.726(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 19 October 2021
Resolution: Replaced waterlight in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 September 2021 Resolved
SC11: At each inspection for certification and every other vessel inspection all observed unsafe practices and other hazardous situations must be corrected. The deck rail/stanchion on the upper deck near the port quarter and the first stanchion on the starboard side of the bow are loose and present a hazardous situation to passengers. Propose repair plan and repair the deck rail/stanchions to the satisfaction of the OCMI. 46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Installed angle iron to secure stanchions satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 September 2021 Resolved
SC12: Propulsion Machinery must be suitable in type and design capable of operating under load. One paddle wheel spoke, portside and inboard, were found rotted at the connection to the hub. Renew the one rotted paddle wheel spoke using suitable material to the satisfaction of the OCMI. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 1 October 2021
Resolution: Replaced rotted spoke in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
SC13: Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The stairway lights leading to the top deck were daisy chained with fans and heating equipment. Remove daisy chained equipment to satisfaction of the OCMI. 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 September 2021 Resolved
SC13: The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate the recovery of persons who have fallen overboard. Conducted man overboard drill; crew failed the drill due to lack of announcements on PA system and proper communication with passengers. The second man overboard drill was satisfactory. 46 CFR 185.520(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 September 2021
Resolved 2 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2020 Resolved
Piping for vital systems over 150psig must be inspected in accordance with ANSI B 31.1. Small hydraulic oil leak discovered on the middle pump pressure gauge located on the aft bulkhead of the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 7 October 2021
Resolution: Pressure gauge replaced satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020 Resolved
Lighting Fixtures. Each lighting fixture must be fixed. lighting fixture on the port bulkhead of the changing room was found hanging by its power cable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 7 October 2021
Resolution: Lighting fixture removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020 Resolved
Cable and wiring requirements. Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Fan installed in the starboard aft overhead of the engine room had a open junction box on the motor. Power cable was non approved type and was plugged into an outlet. The fan not have a disconnect switch. Hard wire the fan using approved cable, switch, and provide a cover for the junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 7 October 2021
Resolution: Fan removed from engine room.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The port side damper leading to the engine room was broken and inoperable. Ensure damper is renewed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: Damper renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
Each life jacket kept in a stowage container must be readily available. The PFDs up forward were not readily available due to wires obstructing access. Ensure PFDs are not obstructed by wires and are readily available for immediate use.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: Wires were secured satisfactory to bottom of cabinet, no longer obstructing life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The adult and child pfds were not marked and separated. Ensure adult and child pfds are marked and separated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: Adult and child lifejackets were separated and properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. The stowage spaces for PFDs, up forward and astern, were not marked. Clearly mark all stowage spaces for PFDs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: PFD's were clearly marked with size and number in their correct locations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2019 Resolved
Cable and wire for power and lighting circuits must meet one of the following in 46 CFR 183.40(d). The cables up forward near the Life Jacket stowage area was not an approved type of cable. Renew cable IAW 46 CFR 183.40(d).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 15 October 2019
Resolution: Cable replaced with approved UL listed Boat cable
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2019 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. A small battery installation must not be in a closet, storeroom or similar space. The battery cover in the engine room was unable to close and protect the batteries from falling objects. Ensure batteries are are protected from falling objects.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 6 September 2019
Resolution: Battery cover was replaced and secured satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 September 2019 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The lighting fixture junction box located in the bar area was hanging and not properly secured. Install lighting fixture junction box IAW the manufacturer’s recommendation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 6 September 2019
Resolution: Lighting junction box was secured satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 September 2019 Resolved
High pressure gas storage cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. The cylinder in the bar area was not secured. Ensure cylinder is properly secured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 6 September 2019
Resolution: CO2 bottle was properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2019 Resolved
Propulsion Machinery must be suitable in type and design capable of operating under load. 9 Paddle wheel spokes were found rotted at the connection to the hub. Renew all 9 rotted paddle wheel spokes using suitable material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 15 October 2019
Resolution: Wasted spokes were replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 March 2019 Resolved
Vessel must crop and renew extensive wood rot was found in port stern thruster room
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 28 March 2019
Resolution: All rotted wood has been cropped and renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2019 Resolved
Vessel must install three (2A) portable fire extinguishers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2019
Resolution: Vessel installed and mounted 3 (2A) portable fire extinguishers.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 January 2019 Resolved
Vessel must repair port side longitudinal frames and bilge strake are fractured in the amidship compartment underneath the galley.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2019
Resolution: Hull damage from bridge allision cropped out and repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 January 2019 Resolved
Vessel must submit repair proposal for damage from bridge allision
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2018 Resolved
Replace cracked hydraulic hose on starboard paddle drive motor.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2018
Resolved 6 September 2018
Resolution: Replaced cracked hose with new hose
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018 Resolved
Provide sewage disposal receipts.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2018
Resolved 6 September 2018
Resolution: Owner provided receipts from Carl's Septic Tank Cleaning Inc.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 September 2018 Resolved
Repair aft 3 stantions on port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2018
Resolved 19 September 2018
Resolution: All three stantions were repaired and reglassed/tabbed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2018 Resolved
Repair starboard linear steering ram.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2018
Resolved 6 September 2018
Resolution: Repaired leakin steering ram.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2018 Resolved
Replace rotted spokes and paddles on port and starboard paddle wheels
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 19 September 2018
Resolution: replaced all rotted spokes and paddles.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 September 2018 Resolved
Replace missing non-combustible insulation in engine room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 19 September 2018
Resolution: Repaired engine room hath and added new insulation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018 Resolved
Provide proof of enrollment in a DAPI program for all crewmembers
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 6 September 2018
Resolution: Owners provided proper documentation for crewmwembers enrolled in a DAPI program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 August 2017 Resolved
Provide either a 1st Aid Kit approved under 46 CFR 160.041, or a kit with the equivalent contents. The 1st Aid Kit must be stowed in a properly labeled, watertight container.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 8 November 2017
Resolution: See narrative.
Documentation › Logs/Records › Drug Test Records
Issued 23 August 2017 Resolved
Provide proof of enrollment in a DAPI program for all crewmembers working aboard the vessel in a safety sensitive position.
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 25 August 2017
Resolution: [name withheld] provided documentation as requested (via fax).
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 August 2017 Resolved
Replace alcohol test detectors/swabs with expired dates.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Resolution: See narrative. (New alcohol testing devices expire in January of 2018.)
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2017 Resolved
Replace retro-reflective tape on ring/life buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Engineering › Non-conventional Propulsion/Steering › Fixed-Pitch Propeller (Azipod)
Issued 23 August 2017 Resolved
Replace missing hardware on paddle boards and spokes. Repair loose spokes on the starboard side of the paddle wheel. (Was not able to find spokes/paddle boards under the "Components" drop-down list for non-conventional propulsion types.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 August 2017 Resolved
Repair and/or replace deck rail stantion at the port-side embarkation station. Current stantion is not properly affixed to the deck at its base.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 August 2017 Resolved
Provide fire servicing report for required portable fire extinguishers and the fixed CO2 system in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Resolution: Completed on July 27th, 2017, by Instant Fire Protection Co.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2017 Resolved
Remove/replace spliced wires in void compartments. Each connection to a conductor or terminal part should be made within an enclosure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2017 Resolved
Remove twist-on wire connectors used for making connections in the electrical wiring system; use proper termination blocks with "captive" type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 23 August 2017 Resolved
Replace modular smoke detecting units with ones that are UL 217 approved and which contain an independent power source.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 6 September 2017
Engineering › Bilge Water Management System › Not Operational
Issued 23 August 2017 Resolved
Repair electrical bilge pumps and high-level alarms switches in void compartments.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2017
Resolved 6 September 2017
Resolution: Fixed during the course of the inspection.
Fire Fighting › Fire Main › Material
Issued 23 August 2017 Resolved
Repair sections of fire main piping (CUNI) where electrolysis has damaged the copper nickel piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 8 November 2017
Communications › Alarms/Indicators › General Alarm
Issued 23 August 2017 Resolved
Prove proper operation of the high temperature alarm for the wet exhaust system. Either an audible or visual alarm is required.
Condition: Improper/Lack of Maintenance
Due 23 September 2017
Resolved 6 September 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2016 Resolved
Place guards over kitchen (galley) lighting (02). 46CFR183.410
Action required: 705 - Other - as specified
Due 8 October 2016
Resolved 30 September 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 September 2016 Resolved
Proivde up to date nav rules. 46CFR184.420
Action required: 705 - Other - as specified
Due 8 October 2016
Resolved 30 September 2016
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 September 2016 Resolved
Provide valid license for vessel's captain. 46CFR185.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 2 May 2016 Resolved
Turbocharger lagging was oil soaked from engine casualty and began to smolder when the turbo reached operating temperature.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 3 May 2016
Resolution: Turbocharger lagging was replaced with new lagging, and functionality was verified with engine operation test.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 3 April 2016 Resolved
Engine suffered a total loss of lube oil and jacket water, causing the engine to seize.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 2 May 2016
Resolution: Engine was totally rebuilt, all auxiliary machinery and components were reattached and functional, engine was broken in per the manufacturer's instructions, technician report was provided verifying repairs, sea trials were conducted, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 August 2015 Resolved
Please submit a detailed proposal using the correct size wire/cable, over current device(s), conduit size, etc. for 100 amp service. Another option is to install a proper over current device on the pier to account for your 60 amp shore tie.
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Resolution: Wiring and connections as per approved proposal
Engineering › Lubricating Oil Service System › Hose
Issued 13 May 2014 Resolved
Hydraulic hose burst on initial pressurizing of system on 13 May 2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 14 May 2014
Resolution: Hydraulic hose company replaced burst hose.
Engineering › Reduction Gearing/Clutches › Gear
Issued 11 June 2012 Resolved
Prove proper operation of the stbd paddlewheel hyd. motor/gear box (post mechanical failure). Also provide a copy of the condition found/repair report. This must be corrected prior to carrying passengers. 46 CFR 182.220
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2012
Resolved 22 June 2012
Resolution: system operated properly.
Engineering › Reduction Gearing/Clutches › Hose
Issued 11 June 2012 Resolved
Replace supply hose (torn/worn outer jacket) and return hose (blistered) on port hydraulic motor (paddlewheel drive). Both hoses must meet SAE J1942 and be rated for the intended service and pressure. This must be completed prior to carrying passengers. 46 CFR 182.220
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2012
Resolved 22 June 2012
Engineering › Bilge Water Management System › Piping
Issued 24 January 2012 Resolved
Provide bilge piping in stbd sewage compartment IAW 46 CFR 182.500(a) and 46 CFR 182.510(a) prior to carriage of passengers. Note: vertical bilge pipe not connected to horizontal bilge pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2012
Resolution: Vessel refitted stbd sewage compartment bilge pipe: connected vertical pipe to horizontal pipe with glued-on elbow.
Construction/Loadline › Structures › Superstructure
Issued 13 January 2012 Resolved
Have ea. of the (5) 1 1/2" dia. pipe vert. stanchions fully welded to upper steel beam attaching brkts. 46 CFR 177.300 When reattaching lower mounting flange, existing lag bolts may be used for holes lining up w/ 2X8 beams. Bolts (carriage) shall be used (min. 3/8ths") shall be used in conjunction with butt blocks (min. 2X8 x 12" lg.) for unsupported attachment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2012
Resolved 26 January 2012
Resolution: Verified proper fastening and welding of stanchions.
Construction/Loadline › Structures › Superstructure
Issued 13 January 2012 Resolved
Open up rotted footing in port side outboard exterior bulkhead in way of galley convection ovens. All rotted wood needs to be excavated to good wood. Have written/sketched repair proposal ready for attending CG marine inspector. Once the bulkhead is opened, no passengers may be carried.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2012
Resolved 26 January 2012
Resolution: Main deck port and stbd bulkheads repaired IAW approved repair proposal (attached) and to satisfaction of attending U.S. Coast Guard Marine Inspector.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 January 2012 Resolved
Provide proper mechanical fastening of port and starboard main deck bulkheads to the deck clamp IAW 46 CFR 177.300. Prior to repairs submit mechanical fastening proposal to attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2012
Resolved 24 January 2012
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 January 2012 Resolved
Provide complete structural restoration of the starboard main deck bulkhead IAW 46 CFR 177.300.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2012
Resolved 24 January 2012
Operations/Management › Drills/Instruction › Fire
Issued 28 January 2011 Resolved
Must conduct emergency drills 46 CFR 185.520/.524
Due 4 February 2011
Resolved 4 February 2011
Resolution: Conducted drills with crewmembers [name withheld] (captain), [name withheld] (engineer), [name withheld](crew) and Colleen Chesbrough (crew). In addition, the following hospitality/waitstaff were als present: Mackenzie Landry, Rhonda Mann, [name withheld],
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 28 January 2011 Resolved
Properly wire automatic bilge pumps in the following compartments; port and stbd thruster compartments, potable water compartment, and sewage compartment. 46 CFR 183.340
Due 4 February 2011
Resolved 4 February 2011
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 January 2011 Resolved
Properly mount breaker panel in scullery. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Due 4 February 2011
Resolved 4 February 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2011 Resolved
Remove or properly terminate dead end wires above sewage tank. 46 CFR 183.340
Condition: Improper Installation
Due 4 February 2011
Resolved 4 February 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 28 January 2011 Resolved
Properly make water tight wire going through the bulkhead aft of the portside gangway. 46 CFR 183.210
Due 4 February 2011
Resolved 4 February 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 28 January 2011 Resolved
Properly install and demonstrate proper operation of main engine shutdown switch from primary operating station. 46 CFR 184.620(b)
Due 28 January 2011
Resolved 4 April 2011
Resolution: Rescinded
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 January 2011 Resolved
Make sanitary all deck spaces in and around scullery and galley
Due 4 February 2011
Resolved 4 February 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 21 January 2011 Resolved
Repair hydraulic leak on stbd hydraulic manifold which is leaking 30-45 drops per minute. It is to be completed by the next scheduled inspection but no later than 29 Jan 2011. 46 CFR 182.200. Item to be completed to the satisfaction of the attending C.G. inspector.
Due 29 January 2011
Resolved 28 January 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 2 December 2010 Resolved
Prior to carrying passengers, make the vessel available to a Coast Guard Inspector for sea trials. The vessel must get underway with a Coast Guard Inspector and conduct such underway machinery tests as deemed necessary and to the satisfaction of the attending Coast Guard Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 19 November 2010 Resolved
Prior to carrying passengers, provide a third party condition found and repair report in regards to the main engine overheating event occurring on the night of 18 November 2010.
Action required: 705 - Other - as specified
Due 29 January 2011
Resolved 21 January 2011
Construction/Loadline › Hull › Side Shell
Issued 18 February 2010 Resolved
Provide contact information and name of fiber glass repair technician that will be completing fiber glass repairs on the vessel. Complete repairs to port bow area as outlined in repair proposal. All repairs to be completed to the satisfaction of the attending Coast Guard Marine Inspector prior to carriage of Passengers. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2010
Resolution: Repairs completed at Newburg Oregon.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 February 2010 Resolved
Replace the damaged fwd railing stanchion located on the forward main deck adjacent to the bow ramp on the starboard side. Base of stanchion has multiple fractures rendering it no longer serviceable. 46 CFR 177.900 (b)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2010
Resolution: Base has been replaced w/ 4 x 4 pressure treated wood, w/ pipe insert.
Construction/Loadline › Structures › Superstructure
Issued 18 February 2010 Resolved
Remove all rotted bulkhead material (including paneling and internal framing) in way of the galley dish washing station, port side aft main deck. All rotted material must be excavated and prepped for re-construction. After excavation, the site must be examined by a CG marine inspector and a complete repair proposal will be presented to the inspector for review. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Due 22 March 2010
Resolved 22 March 2010
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 18 February 2010 Resolved
Tighten all fasteners associated with the propulsion paddle wheel spokes and paddles. This includes all fasteners securing outer paddle steel ring bracket to the wooden paddles; the wooden paddle-to-spoke bolts; the radial steel support ring-to-spoke bolts and all hub bolts. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Due 22 March 2010
Resolved 22 March 2010
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 18 February 2010 Resolved
Replace the following Port side paddle wheel spokes: Port Wheel #11 outboard spoke due to heavy rot in the outer 24 inches; #6 outboard spoke due to deep rot. #16 inboard spoke due to rot and wear damage caused by loose fasteners. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Due 22 March 2010
Resolved 22 March 2010
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 18 February 2010 Resolved
Replace the following Stbd side paddle wheel spokes: #1 inboard spoke due to rot; #3 inboard spoke due to rot; #4 outboard spoke due to rot; #5 outboard spoke due to rot; #7 inboard spoke due to rot; #11 inboard spoke due to rot. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Due 22 March 2010
Resolved 22 March 2010
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 18 February 2010 Resolved
Replace the badly split paddle board on the stbd side paddle wheel in way of spoke #4. New paddle shall be clear Douglas fir and of equal scantling. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Due 22 March 2010
Resolved 22 March 2010
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 18 February 2010 Resolved
Replace the missing steel bracket on the outer steel paddle support ring on the port side propulsion paddle, in board side in way of paddle #1. 46 CFR 182.100
Condition: Damaged By Earlier Event
Due 22 March 2010
Resolved 22 March 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 February 2010 Resolved
Remove the broken splash zone patch work on the aft stbd bulkhead at the bilge in the sewage tank space, remove damaged bulkhead material back to good wood, including cracked areas. Make both sides of the bulkhead available for inspection. Present a repair proposal to the inspector for review. 46 CFR 177.100
Condition: Damaged By Earlier Event
Due 22 March 2010
Resolved 22 March 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 February 2010 Resolved
Provide written repair proposal addressing the cracks on the port side of the fwd engine room bulkhead at the bilge stringers. Provide name and contact information of the fiber glass repair technician that will be completing the repairs. 46 CFR 177.100
Condition: Damaged By Earlier Event
Due 22 March 2010
Resolved 22 March 2010
Fire Fighting › Fire Hoses › Condition
Issued 28 January 2010 Resolved
Brass nozzle required to be on port side upper deck hose was missing, and stbd side had a blockage in the nozzle
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2010
Resolved 28 January 2010
Resolution: Port Nozzle returned to hose and Stbd nozzle cleared of obstruction.
Construction/Loadline › Hull › Hull Plating
Issued 28 January 2010 Resolved
Complete dry-docking and hull inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2010
Resolved 26 February 2010
Resolution: Completed dry-dock and hull inspection; Prior to carriage of passenger items were completed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 9 December 2008 Resolved
Black Water leaking into bilge from around base of toilet in aft head. Seal toilet to prevent further leaks. 46 CFR 176.818.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2009
Resolved 22 January 2009
Resolution: Received fax from vessel owner declaring parts came in and toilet has been re-installed and checked for leaks.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 December 2008 Resolved
Beer cooler is required to be hard wired into a junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 January 2009
Resolved 9 January 2009
Resolution: Marine Inspector witnessed satisfactory repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2008 Resolved
RA13: Hydraulic selenoid valve wiring is loose and cut. Secure loose ends and repair cut wires. 46CFR 183.340
Condition: Improper/Lack of Maintenance
Due 10 December 2008
Resolved 9 December 2008
Resolution: Wiring tied back and secured.
Engineering › Lubricating Oil Service System › Hose
Issued 10 November 2008 Resolved
RA14: Port side engine oil bypass filter hoses are worn; renew hoses. 46CFR182.720
Condition: Improper/Lack of Maintenance
Due 10 December 2008
Resolved 9 December 2008
Resolution: New hoses installed.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 10 November 2008 Resolved
RA15: Lagging around MDE turbo-charger is missing. Install lagging. 46CFR176.830
Condition: Unknown
Due 10 December 2008
Resolved 9 December 2008
Resolution: New lagging installed
Fire Fighting › Fire Hoses › Material
Issued 10 November 2008 Resolved
RA16: Replace fire hose located 1st deck aft with correct size and type in accordance with 46CFR181.15-10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Replaced hose.
Fire Fighting › Fire Hoses › Connections
Issued 10 November 2008 Resolved
RA17: Hose connection on both STBD side fire hoses are leaking. Repair or renew connections in accordance with 46CFR181.15-10.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2008
Resolved 12 November 2008
Resolution: Repaired or renewed brass fittings.
Engineering › Bilge Water Management System › Not Operational
Issued 10 November 2008 Resolved
RA18: Prove proper operation of bilge alarm in port aft void. 46CFR182.530
Condition: Improper/Lack of Maintenance
Due 10 December 2008
Resolved 9 December 2008
Resolution: Alarm worked properly.
Engineering › Bilge Water Management System › Not Operational
Issued 10 November 2008 Resolved
RA19: Correctly label bilge alarm panel on bridge in accordance with 46CFR182.530.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Bilge alarm panel updated and renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
RA01: Port, aft void light is missing cover. Install cover in accordance with 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Light cover replaced.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 November 2008 Resolved
RA02: Deck longitudinal in way of hatch in port aft void is loose. Renew or repair fastener in accordance with 46CFR176.802.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Installed new fastener.
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 November 2008 Resolved
RA03: Aft sink drain pipe in scullery is broken. Renew or repair pipe in accordance with 46CFR176.830.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Installed new piping.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
RA04: Light cover in sculery is broken. Renew cover in accordance with 46CFR183.410.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Light covers are a new bulb wrap around cover.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
RA06: Port hydraulic void light is missing cover. Install cover in accordance with 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 January 2009
Resolution: Marine Inspector witnessed satisfactory repair.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 10 November 2008 Resolved
RA06: Install bracket on hydraulic tank level switch in accordance with 46CFR183.340.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 January 2009
Resolution: Marine Inspector witnessed satisfactory repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2008 Resolved
RA07: Distribution box on FWD bulkhead in sewage void is not installed properly. Plug stuffing tubes and seal wire runs in accordance with 46CFR183.340.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 January 2009
Resolution: Marine Inspector witnessed satisfactory repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2008 Resolved
RA08: Secure wiring on water heater in accordance with 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Wiring was correctly installed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 November 2008 Resolved
RA09: FWD bulkhead in fuel tank void has a unsealed cable penetration. Seal penetration in accordance with 46CFR179.320.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Sealed penetration
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 10 November 2008 Resolved
RA10: Fuel fill pipe in fuel tank void has a patch on it. Remove and inspect gasket for wear in accordance with 46CFR182.440.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Gasket was checked and inspected
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2008 Resolved
RA11: Hard wire lighting for boarding platform in accordance with 46CFR183.340.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 January 2009
Resolution: Marine Inspector witnessed satisfactory repair.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 November 2008 Resolved
RA12: Seal two penetration in STBD Aft void in accordance with 46CFR179.320.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Penetration sealed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 November 2008 Resolved
MH01: Attach retro-reflective tape on portside life ring and replace light battery in accordance with 46CFR180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Replaced retro-reflective tape.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 November 2008 Resolved
MH02: Repair upper deck center aft hand rail stantion in accordance with 46CFR177.900(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Stantion repaired
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 10 November 2008 Resolved
MH03: Repair power distribution panel on bridge in accordance with 46CFR183.220.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Panel is in compliance.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 November 2008 Resolved
MH04: Correctly label life-vest stowage compartment in accordance with 46CFR180.78.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Compartment has been labled
Accommodation/Occupational Safety › Ventilation › General
Issued 10 November 2008 Resolved
MH05: Install protective covers on and prove proper operation of both galley exhaust fans in accordance with 46CFR177.600.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: In compliance.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 November 2008 Resolved
MH06: Install cover on wire juction box above port side galley entrance in accordance with 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Cover replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2008 Resolved
MH07: Secure dead-end wire on FWD STBD side speaker. 46CFR183.340.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Wire has been secured.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 November 2008 Resolved
MH08: Hydrostatic test or renew B-2 Fire Extinguisher (FWD Stairwell) 46CFR176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2008
Resolved 12 November 2008
Resolution: Loaner extinguisher is in place while oringinal is being serviced.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
MH09: Install bulbs in all open light fixtures and repair all loose light fixtures in accordance with 46CFR183.410.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Fixtures have been tightened and bulbs replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
MH10: Install cover on light fixture above ice machine in accordance with 46CFR183.410.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Light cover replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 November 2008 Resolved
MH11: Repair FWD handrail stantion at the port side embarkation ramp and the STBD handrail stantion adjecent to bow ramp. 46CFR177.900(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Handrail stantioned was repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
MH12: Remove all disconnected light fixtures in galley in accordance with 46CFR183.410.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Light fixtures have been removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2008 Resolved
RA05: Install cover on light fixture in port hydraulic void. 46CFR183.340.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 9 December 2008
Resolution: Installed a new cover
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 December 2007 Resolved
Provide written proof of enrollment in consortium.
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 11 December 2007
Documentation › Logs/Records › Drug Test Records
Issued 11 December 2007 Resolved
Provide proof of random/pre-employment testing.
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 11 December 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 December 2007 Resolved
Update drug testing policy to reflect current vessel operations.
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 11 December 2007
Documentation › Logs/Records › Drug Test Records
Issued 11 December 2007 Resolved
Update drug testing policy to reflect return to work practices.
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 11 December 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 December 2007 Resolved
Update list of treatment centers.
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 11 December 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 October 2007 Resolved
Make operable engineroom bilge audible alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 31 October 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 October 2007 Resolved
Make repairs to or renew port rail stanchion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 29 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 October 2007 Resolved
Re-label port 01 deck life ring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 29 November 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 October 2007 Resolved
Provide 1 child size lifejacket for each dining room stowage bin.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Resolution: Enough child life jackets were onboard. Master re-labeled the stowage bins to reflect the correct amount in each.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 October 2007 Resolved
Cutout 12 inch wasted area of stbd rail at embarkation and renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 29 November 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 29 October 2007 Resolved
Remove 1 12v light fixture in stbd fuel compartment and 1 12v fixture in bow compartment. blank or remove Dead end wires.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 31 October 2007
Resolution: Lighting fixtures replaced with new fixtures.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 October 2007 Resolved
Remove standing water in fuel and bow compartments.
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 29 October 2007 Resolved
Remove all potable extension cords and rewire in accordance with 46 CFR 183.50-20. 25% to be completed prior to carrying passengers and remainder prior to compleation of Febuary DD.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2008
Resolved 9 January 2009
Resolution: Marine Inspector witnessed a satisfactory repair.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 October 2007 Resolved
replace broken bulbs on upper deck light strings.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 31 October 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 29 October 2007 Resolved
Replace head lighting fixture with UL approved marine type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Resolution: Bulbs were replaced with U/L Listed "shatter-proof " bulbs.
Engineering › Thrusters › Piping
Issued 29 October 2007 Resolved
Install cover on thruster control box. eliminate excessive wire splices.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 29 October 2007
Resolution: Corrected wiring and installed temporary cover.
Engineering › Fuel Oil Service System › Filter
Issued 29 October 2007 Resolved
Connect Racor filter, install drain plug and flame shield.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 31 October 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 29 October 2007 Resolved
Repair SSDG conduit connection forward end of generator housing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 29 October 2007 Resolved
CO2 tank for soda machine is not properly secured. Properly secure prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 29 October 2007
Resolution: Secured
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 October 2007 Resolved
Install cover on potable water pump electrical motor and switch box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 29 October 2007 Resolved
Eliminate dead end live 110v wire above potable water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Engineering › Bilge Water Management System › Pump
Issued 29 October 2007 Resolved
Install pump switch to allow proper operation of the pump in Stbd potable water tank space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 31 October 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 December 2006 Resolved
Have broken fuse holder on the Blodgett convection oven repaired (right side holder). Currently has bare wire conductor wire pulled thru body of holder so that bare wire makes contact with top of fuse. Fuse holder body's metal contact (for cap contact point) had broken. Bare wires are dangerously close to holder's screw cap. No use permitted until corrected.
Condition: Improper/Lack of Maintenance
Due 7 January 2007
Resolved 4 January 2007
Stability › Incline Test › General
Issued 6 December 2006 Resolved
Comp. simp stab test, IAW 46 CFR 178.330. This req amends HO01 by postponing compliance date for testing until 04JAN07 and permitting ltd ops provided the following restricitons & req. are followed: Total # Pax is ltd to 73; ltd to calm conditions & winds NMT 30 kts; 3768 lbs of temp weight to be installed; No further changes/mods to existing ballast.
Due 4 January 2007
Resolved 4 January 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 6 December 2006 Resolved
Complete and submit to this office, an electrical load analysis that depicts the curent load on the A/C electrical system. The result of this analysis should indicate that the current a/c generator installation is still adequate in light of the sadditional electrical loads added on to this vessel since original system acceptance 46 CFR 177.202(b)(4)(ix)
Condition: Improper Installation
Due 6 January 2007
Resolved 14 May 2007
Stability › Incline Test › General
Issued 4 December 2006 Resolved
Complete a simplified stability test, in accordance with 46 CFR 18.330.
Condition: Improper Installation
Due 4 January 2007
Resolved 4 January 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 December 2006 Resolved
Have vessel prepared and have CG marine inspectors carry out a re-measurement of the vessel's passenger accommodation areas to update passenger allowance. 46 CFR 177.500
Due 4 January 2007
Resolved 4 January 2007
Construction/Loadline › Structures › Superstructure
Issued 4 December 2006 Resolved
Complete the repair to port side main under deck support stringer (outboard side under the upper deck exterior patio). You must call and schedule a CG marine inspector from this office once the rotted material has been removed, but prior to fit-up of the replacement scarf. 46 CFR 176.802
Condition: Improper Installation
Due 4 January 2007
Resolved 14 May 2007
Construction/Loadline › Structures › Deck Plating
Issued 30 October 2006 Resolved
PT01: Submit repair proposal to repair rotted area of aft second deck patio area aboe the paddle wheel.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 October 2006 Resolved
PT 02: Repair rotted base of first lower stanchion stbd side.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 October 2006 Resolved
PT 03: Repair loose hand rails Port and Starboard side of bow ramp.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Engineering › Lubricating Oil Service System › Filter
Issued 30 October 2006 Resolved
PT 04: Repair oil leak on main lube oil houseing on main diesel engine.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 30 October 2006 Resolved
PT 05: Mount forward fire pump in engine room.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Resolution: Fire pump mounted.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 October 2006 Resolved
PT 06: Replace port and starboard side electrical receptacle in engine room with splash proof fixtures.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2006 Resolved
PT 07: Rewire control solenoid for bow and stern thrusters in engine room.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Stability › Watertight Integrity › General
Issued 30 October 2006 Resolved
PT 08: Permanently close off sud tube in engine room with watertight cap. Currently open.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Fire Fighting › Fire Hoses › Material
Issued 30 October 2006 Resolved
PT 09: Replace section of garden house on fire pump with USCG approved A1, A2 or B1, B2 hose of JIC SAE 1942 approved hose.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Engineering › Fuel Oil Service System › Piping
Issued 30 October 2006 Resolved
PT 10: Properly secure fuel oil supply and hard piping in engine room starboard side deck.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 October 2006 Resolved
PT 11: Secure raw water exhaust cooling and keel cooler vent lines hanging from engine room overhead.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 30 October 2006 Resolved
PT 12: Rewire and properly secure wire from small battery charger (DC Output)
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 30 October 2006 Resolved
PT 14: Secure loose turbo charger exhaust lagging.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 October 2006 Resolved
PT 21: Secure all loose fasteners in upper life rail bases.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 October 2006 Resolved
PT 22: Secure starboard side aft corner of upper rail.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 30 October 2006 Resolved
PT 30: Make operable bow and water compartment bilge alarms.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 30 October 2006 Resolved
PT 31: Provide and install covers for various J boxes and lighting fixtures throughout the ship.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 30 October 2006 Resolved
PT 29: Provide and install blank in galley distribution panel.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 30 October 2006 Resolved
PT 16: Replace hydraulic hose penetrating forward engine room bulkhead with proper bulkhead fitting.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 30 October 2006 Resolved
PT 19: Seal cable pentration in forward port side of engine room.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 October 2006 Resolved
PT 25: Rewire stern light. Eliminate loose wire and inline splices.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 October 2006 Resolved
PT 27: Rewire anchor and mast headlights.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 30 October 2006 Resolved
PT23: Remove portable spot light on pilot house top and extension cord.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 October 2006 Resolved
PT 32: Renew hose from aft engine to starboard aft keel cooler (hose has surface cracks).
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 30 October 2006 Resolved
PT 15: Renew control air connection to the port hydraulic pump. Hose is kinked and cracked.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 October 2006 Resolved
PT 26: Permanently repair nav light mast assembly. Mast rotates freely. Mast must be oriented and permanently secured as to meet inland nav rules.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 30 October 2006 Resolved
PT 20: Secure overhead sewage pipes in hydraulic compartment.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Engineering › Compressed Air System (control) › Compressor
Issued 30 October 2006 Resolved
PT 18: Properly mount forward air compressor.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Electrical › Lighting (service) › Lighting Feeder
Issued 30 October 2006 Resolved
PT 24: Replace extension cord on cabin top with marine grade cable and fixtures.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 October 2006 Resolved
PT 13: Secure electrical box on engine room vent motor and properly rewire motor.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 November 2006
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 30 October 2006 Resolved
PT 28: Provde and post waste managment plan.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 6 November 2006
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 30 October 2006 Resolved
PT 17: Secure electrical shroud on A/C generator housing.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 13 November 2006
Operations/Management › Drills/Instruction › Fire
Issued 28 November 2005 Resolved
Fire plan does not match locations of portable CO2 extinguisher in bar/ galley area. Relocate extinguisher to match plan or change plan to show proper location of extinguishers.
Due 16 December 2005
Resolved 28 November 2005
Resolution: Chief engineer moved extinguisher to match location depicted on fire plan.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 November 2005 Resolved
Labeling for the storage of lifejackets does not match the number listed to the amount of lifejackets stored in 3 areas of the vessel. Change labels to match the number of jackets or add/ subtract jackets to match labels in lifejacket storage areas.
Due 2 December 2005
Resolved 28 November 2005
Resolution: Owner/Master changed labeling to reflect the correct number of life jackets in each storage area.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 28 November 2005 Resolved
ONLY ONE OUT OF SEVEN EMPLOYEES WERE PARTICIPATING IN RANDOM DRUG TESTING PROGRAM AS PER DOCUMENTATION FROM CONSORTIUM. (WPCI) AT THE TIME OF THE AUDIT. 11/28/2005. ON 12-7-2005 RECIEVED NOTIFICATION FROM WPCI THAT ALL SAFETY SENSITIVE PERSONNEL WERE IN RANDOM POOL.
Due 28 December 2005
Resolved 7 December 2005
Resolution: ALL PERSONNEL IN SAFETY SENSITIVE POSITIONS ARE IN RANDOM POOL A TOTAL OF EIGHT.
Engineering › Lubricating Oil Service System › Hose
Issued 1 September 2005 Resolved
Make repairs to the vessel's propulsion system (hydraulic hose replacement). To clear this requirement, fax or email a copy of the invoice that I.D.'s the replacement hose. Also provide a written/signed statement issued by vessel's master that indicates new hose was installed and tested. 46 CFR 182.200
Condition: Improper Installation
Due 1 September 2005
Resolved 1 September 2005
Fire Fighting › Fire Main › Condition
Issued 7 December 2004 Resolved
Repair as original the water leak at the fire pump PRIOR TO CARRIAGE OF PASSENGERS. 46CFR176.800(a); 46CFR181.300
Due 7 January 2005
Resolved 8 December 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 December 2004 Resolved
Renew flexible hose at seawater discharge pipe in the engine room. 46CFR182.720
Due 7 January 2005
Resolved 10 January 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 December 2004 Resolved
Renew jacket water heater discharge hose in the engine room. 46CFR182.720
Due 7 January 2005
Resolved 10 January 2005
Engineering › Steering Gear System › Piping
Issued 7 December 2004 Resolved
Renew hydraulic hose where outer cover is breached in the engine room. 46CFR182.720
Due 7 January 2005
Resolved 10 January 2005
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 7 December 2004 Resolved
Renew spud connector for the exhaust capacitor-start motor in the engine room. 46CFR183.200
Due 7 January 2005
Resolved 10 January 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 December 2004 Resolved
Renew flexible hose (hydraulic steering hose) that extends throughout all compartments. The outer cover has large patches breached with corrosion of the reinforcement layer. Found several areas like this in every compartment. 46CFR182.720
Due 7 January 2005
Resolved 10 January 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 December 2004 Resolved
Provide chafing gear for all hydraulic hose supports (both metal & plastic have been chafting) in all underdeck compartments. 46CFR182.720(e)(3)(ii).
Due 7 January 2005
Resolved 10 January 2005
Engineering › Thrusters › Piping
Issued 7 December 2004 Resolved
Renew hydraulic hose for port bow thruster (outer cover breached). 46CFR182.720
Due 7 January 2005
Resolved 10 January 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 December 2004 Resolved
Remove yellow flexible cord installed at electrical outlet (in potable water compartment) and renew with cable meeting 46CFR183.340. (This outlet serves cola machine & beer cooler).
Due 7 January 2005
Resolved 10 January 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 December 2004 Resolved
Make electrical outlet (mentioned in JA09) weather proof. 46CFR183.210
Due 7 January 2005
Resolved 10 January 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 December 2004 Resolved
Provide eye wash solution for first aid kit. 46CFR184.710
Due 7 January 2005
Resolved 10 January 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 December 2004 Resolved
Provide a total of 141 adult life jackets with properly designated locations. 46CFR180.78. Currently some of the extended size life jackets were being counted for both adult and child use. And the quantity marked on the signs did not add up correctly.
Due 7 January 2005
Resolved 10 January 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 December 2004 Resolved
Submit all vessel's drug and alcohol testing program records/documents for a Coast Guard DAPI audit. To be completed no later than 07JAN05. 46 CFR 16
Due 7 January 2005
Resolved 23 June 2005
Resolution: Confirmed with IO shop that the DAPI audit was completed on 18Mar05.
Deck/Cargo › Mooring/Anchoring
Issued 9 February 2004 Resolved
Prove proper operation of forward anchor line compartment's hatch cover and provide capturing device. LEGACY COMPONENT DESC: Anchor line compartment
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 3 March 2004
Construction/Loadline › Structures
Issued 9 February 2004 Resolved
Make engine room vapor tight. LEGACY COMPONENT DESC: Machinery Space Opening
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 3 March 2004
Fire Fighting › Combustible Materials
Issued 9 February 2004 Resolved
Make engine room fire dampers of non-combustible material. LEGACY COMPONENT DESC: Fire Dampers
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 3 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 9 February 2004 Resolved
Provide wire guards on blower motor in engine room port side. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 3 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 9 February 2004 Resolved
Prove proper operation of port and starboard gates and railings on main deck. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 3 March 2004
Electrical › Mast
Issued 9 February 2004 Resolved
Make permanent repairs to wire entering base of mast for all around white light. LEGACY COMPONENT DESC: Wire
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 3 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 9 February 2004 Resolved
Submit proposal to MSO Portland, OR inspections department for review/approval of the relocation of the adult life preservers. LEGACY COMPONENT DESC: Storage
Due 9 March 2004
Resolved 3 March 2004
Resolution: Plans submitted and approved.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 February 2004 Resolved
Provide belt guards on blower motors in engine room, port side.
Action required: 705 - Other - as specified
Due 23 February 2004
Resolved 3 March 2004
Electrical › Electrical Distribution System (service)
Issued 15 November 2003 Resolved
Remove all extension cords throughout vessel for all permanently installed equipment. This item is to be completed prior to 24NOV03. LEGACY COMPONENT DESC: Wiring
Due 24 November 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 15 November 2003 Resolved
Properly solder and shape all wires in terminal blocks throughout vessel in accordance with 46 CFR 183.05-50 (b) (3). This item is to be completed prior to 24NOV03. LEGACY COMPONENT DESC: Wiring
Due 24 November 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 15 November 2003 Resolved
Remove wire nuts throughout vessel and make splices in accordance with 46 CFR 183.05-50. This item is to be completed prior to 24NOV03 LEGACY COMPONENT DESC: Wiring
Due 24 November 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 15 November 2003 Resolved
Re-wire bilge pumps and bilge high-level alarm electrical system in accordance with 46 CFR part 183. This item is to be completed prior to 24NOV03 LEGACY COMPONENT DESC: Wiring
Due 24 November 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 15 November 2003 Resolved
Remove or end in junction box all dead-ended cables under operating console in pilot house. This item is to be completed prior to 24NOV03 LEGACY COMPONENT DESC: Wiring
Due 24 November 2003
Resolved 24 November 2003
Fire Fighting › Fixed Fire Detection System
Issued 15 November 2003 Resolved
Provide operational and maintenance manual for fire detection system. This item is to be completed prior to 24NOV03.
Due 24 November 2003
Resolved 24 November 2003
Fire Fighting › Fixed Fire Detection System
Issued 15 November 2003 Resolved
Prove that fire detection system meets the requirements of 46 CFR 76.27. This item is to be completed prior to 24NOV03
Due 24 November 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 15 November 2003 Resolved
Provide metallic wire hangers for wire and cable runs throughout the vessel. This item is to be completed prior to 24NOV03. LEGACY COMPONENT DESC: Wiring
Due 24 November 2003
Resolved 24 November 2003
Fire Fighting › Fire Pumps
Issued 12 November 2003 Resolved
Fire Pump did not provide adequate water pressure for firefighting purposes. This item is to be completed prior to carrying passengers.
Due 19 November 2003
Resolved 15 November 2003
Fire Fighting › Fixed Fire Detection System
Issued 12 November 2003 Resolved
Demonstrate operation of fire detection system in engineroom. This item is to be completed prior to carrying passengers.
Due 19 November 2003
Resolved 15 November 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 November 2003 Resolved
Provide bracket for fire extinguisher, port side at galley double door. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Mounting Bracket
Due 19 November 2003
Resolved 15 November 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 November 2003 Resolved
Provide bracket for fire extinguisher, starboard side, aft of pilot house. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Mounting Bracket
Due 19 November 2003
Resolved 15 November 2003
Fire Fighting › Remote Fuel Shutoff
Issued 12 November 2003 Resolved
Label emergency fuel shut-off next to handle. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Emergency Fuel Shutoff
Due 19 November 2003
Resolved 15 November 2003
Operations/Management › Navigation Safety
Issued 12 November 2003 Resolved
Identify all switches and lights on operating console in pilot house. This item is to be completed prior to carrying passengers.
Due 19 November 2003
Resolved 15 November 2003
Lifesaving › Lifejacket/PFD (General)
Issued 12 November 2003 Resolved
Mark all PFDs with vessel name. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Marking
Due 19 November 2003
Resolved 15 November 2003
Lifesaving › Lifejacket/PFD (General)
Issued 12 November 2003 Resolved
Re-stow all PFDs so they are accessible to all persons while standing on the deck. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Storage
Due 19 November 2003
Resolved 15 November 2003
Engineering › Bilge Water Management System
Issued 12 November 2003 Resolved
Provide hose-clamp for starboard bilge pump, No. 3 compartment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Hose
Due 19 November 2003
Resolved 15 November 2003
Engineering › Bilge Water Management System
Issued 12 November 2003 Resolved
Provide hose-clamp for starboard bilge pump, No. 4 compartment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Hose
Due 19 November 2003
Resolved 15 November 2003
Engineering › Bilge Water Management System
Issued 12 November 2003 Resolved
Provide hose-clamp for starboard bilge pump, No. 5, sewage compartment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Hose
Due 19 November 2003
Resolved 15 November 2003
Engineering › Bilge Water Management System
Issued 12 November 2003 Resolved
Shorten discharge hose where crimped closed, starboard side, No. 4 compartment bilge pump. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Hose
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Remove all speaker wire, 16 AWG, and 18 AWG wiring for bilge pumps and indicator switches throughout vessel. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Re-wire in accordance with 46 CFR 183.05-50. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Remove wire nuts throughout the vessel and make splices in accordance with 46 CFR 183.05-50. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Wires in terminal blocks throughout vessel are to be soldered and shaped in accordance with 46 CFR 183.05-50 (b) (3). This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Accommodation/Occupational Safety › Potable Water System
Issued 12 November 2003 Resolved
Repair leak in potable water fitting. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Leak
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Properly splice hydraulic solenoid valves in No. 2 compartment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Engineering › Thrusters
Issued 12 November 2003 Resolved
Provide mounting nuts where missing for hydraulic motors in No. 2 compartment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Motor
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Provide cover for junction box in No. 2 compartment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Junction Box
Due 19 November 2003
Resolved 15 November 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 November 2003 Resolved
Renew all expired items in first-aid kit. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Medicine Chest
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Provide cover for junction box above electronic equipment cabinet on upper deck. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Junction Box
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Provide cover for heater wiring behind piano, starboard upper deck. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Remove or end in junction box all dead-ended cables under operating console in pilot house. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Properly wire existing terminal strip outside of 12-volt panel under operating console. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Remove extension cords throughout vessel for all permanently-installed equipment. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003 Resolved
Remove solid conductor cable (household type) port side in overhead next to aft door and re-wire in accordance with 46 CFR part 183. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Wiring
Due 19 November 2003
Resolved 15 November 2003
Communications › Alarms/Indicators
Issued 12 November 2003 Resolved
Label indicator lights and demonstrate operation of bilge pump indicator and bilge high-level alarms. This item is to be completed prior to carrying passengers. LEGACY COMPONENT DESC: Bilge Alarm
Due 19 November 2003
Resolved 15 November 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 12 November 2003 Resolved
Demonstrate operation of propulsion and control systems. This item is to be completed prior to carrying passengers.
Due 19 November 2003
Resolved 15 November 2003
Lifesaving › Buoyant Apparatus
Issued 12 November 2003 Resolved
Renew battery for ring buoy water light. This item is to be completed prior to carrying passengers.
Due 19 November 2003
Resolved 15 November 2003
Engineering › Reduction Gearing/Clutches › Gear
Issued 7 November 2003 Resolved
Vessel is prohibited from operating with passengers until proper operation of propulsion is proved to the satisfaction of the attending marine inspector. This item is to be completed prior to carriage of passengers
Due 18 November 2003
Resolved 8 November 2003
Lifesaving › Lifebuoys
Issued 30 July 2003 Resolved
Vessel is to provide and properly install life line for ring buoy in accordance with 46 CFR 180.70. This is a no sail item and vessel is not to operate until this item is corrected. The item may be cleared with a written and signed statement from master with copy of sales receipt for line. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2003
Resolution: life line was purchased and verified by owner [name withheld]
Operations/Management › Drug and Alcohol Testing
Issued 30 May 2003 Resolved
Demonstrate that crewmembers have pre-employment drug tests and are enrolled in a random program in accordance with 46 CFR part 16. LEGACY COMPONENT DESC: Employee Coverage
Condition: Placed in Improper Service
Due 30 June 2003
Resolved 8 October 2003
Resolution: Demonstrated employment of DAPI.
Engineering › Bilge Water Management System
Issued 30 May 2003 Resolved
Clean bilges in engine room daily until oil leaks have been repaired as called for in CG-835 items 3 and 4 of 23MAY03. LEGACY COMPONENT DESC: Interface Detector
Due 7 June 2003
Resolved 23 June 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2003 Resolved
Repair and demonstrate operation of bilge alarm. This item must be completed prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 24 May 2003
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 May 2003 Resolved
Mark stowage locations for Child PFD's. This item must be completed prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 24 May 2003
Engineering › Non-conventional Propulsion/Steering
Issued 23 May 2003 Resolved
Repair all hydraulic leaks in engine room. LEGACY COMPONENT DESC: Hydraulic Paddlewheel
Condition: Improper/Lack of Maintenance
Due 4 June 2003
Resolved 23 June 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 May 2003 Resolved
Repair egine oil leaks, port side of main engine. LEGACY COMPONENT DESC: Oil Leaks
Condition: Improper/Lack of Maintenance
Due 4 June 2003
Resolved 23 June 2003
Operations/Management › Drills/Instruction › Fire
Issued 23 May 2003 Resolved
Demonstrate fire and man overboard drills in the presence of a Coast Guard inspector. This item must be completed prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 24 May 2003
Electrical › Electrical Distribution System (service)
Issued 20 March 2003 Resolved
Provide protective covers for the light switch and electrical outlet both located on the starboard bulkhead of the main engine room. (46 CFR 183.200 (b). LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Due 26 April 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 20 March 2003 Resolved
Renew or permanently remove the transformer assembly showing signs of overheating located in the electrical outlet on the starboard bulkhead of the main engine room (46 CFR 183.200 (b).
Due 26 April 2003
Resolved 23 June 2003
Electrical › Electric Supply System (service)
Issued 20 March 2003 Resolved
Provide a protective cover assembly for the lower battery assembly in main engine room to protect the battery from falling objects. (46 CFR 183.354 (b). LEGACY COMPONENT DESC: Battery Installation
Due 26 April 2003
Resolved 23 June 2003
Electrical › Electric Supply System (service)
Issued 20 March 2003 Resolved
Permanently remove the portable battery charger from the main engine room. If a battery charger assembly is desired or needed, it must be a marine grade system and permanently mounted. (46 CFR 176.830 (b). LEGACY COMPONENT DESC: Battery Charger
Due 26 April 2003
Resolved 23 June 2003
Engineering › Lubricating Oil Service System
Issued 20 March 2003 Resolved
Submit a repair proposal for review and approval for the permanent repair of the water leak in the forward cover of the hydraulic heat exchanger (46 CFR 176.700 (a). LEGACY COMPONENT DESC: Cooler
Due 2 April 2003
Resolved 23 June 2003
Construction/Loadline › Hull
Issued 3 February 2003 Resolved
Submit a proposal to repair the stbd outboard long. timber supporting upper pass deck. Area has been scarfed but was not done properly. The proposed scarf insert must fit with no gaps or clearances in the mating surfaces; the original timber remaining must be shown to be w/o any rot remaining. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Improper/Lack of Maintenance
Due 31 March 2003
Resolved 20 March 2003
Resolution: Accepted repairs. Entered special note to closely check repairs at each inspection for evidence of wood rot.
Deck/Cargo
Issued 3 February 2003 Resolved
Have all steel cable vangs and hoisting cable (for bow ramp) removed for inspection (this may be satisfied by having a competent commercial testing facility examine all gear and provide a satisfactory inspection report). LEGACY COMPONENT DESC: Bow Ramp Hoist
Due 31 March 2003
Resolved 20 March 2003
Construction/Loadline
Issued 3 February 2003 Resolved
Have hardware and steel cable support wire for the stern yoke frame removed, de-scaled/cleaned and ready for inspection. The alternative method addressed in DD01 may also be used. LEGACY COMPONENT DESC: Stern Yoke Support Wire
Condition: Improper/Lack of Maintenance
Due 31 March 2003
Resolved 20 March 2003
Engineering › Gasoline Engine (auxiliary)
Issued 3 February 2003 Resolved
Re-submit plans for the permanent installation of the 200 H.P. outboard engine currently bolted on to the yoke stern frame. This will include specifying the type and length of fuel hose used, the details for the fuel tank, and the arrangement of the engine's pilot house control. LEGACY COMPONENT DESC: Installation
Condition: Improper Installation
Due 31 March 2003
Resolved 23 June 2003
Engineering
Issued 3 February 2003 Resolved
Renew the following paddlewheel spokes: SOB15; SIB15; SOB3; SOB14; SIB16; POB15; POB14; POB13; PIB3; PIB4; PIB13; POB11. LEGACY COMPONENT DESC: Paddlewheel
Condition: Improper/Lack of Maintenance
Due 31 March 2003
Resolved 20 March 2003
Engineering
Issued 3 February 2003 Resolved
Provide a proposal to repair in place the following paddlewheel spokes: SOB5, SOB6, SOB8, SOB13, SIB9, SIB3, SIB13, PIB9. LEGACY COMPONENT DESC: Paddlewheel
Condition: Improper/Lack of Maintenance
Due 20 March 2003
Resolved 23 June 2003
Personnel › Training
Issued 5 November 2002 Resolved
Have vessel available for fire and "man overboard" drills, using full crew compliment. LEGACY COMPONENT DESC: Drills
Due 12 November 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Messroom
Issued 5 November 2002 Resolved
Clean galley/bar area, specifically under cabinets, sinks, ice maker, dishwasher, refrigerator, range, convection oven. LEGACY COMPONENT DESC: Sanitation
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Messroom
Issued 5 November 2002 Resolved
Clean inside of ice storage bin for ice maker. Remove food material presently stored inside. Repair/correct leakage originating from compresser/condenser housing (leaks into storage bin and on deck). LEGACY COMPONENT DESC: Sanitation
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Messroom
Issued 5 November 2002 Resolved
Clean inside of microwave oven, convection oven, and reach-in refrigerator. LEGACY COMPONENT DESC: Sanitation
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Potable Water System
Issued 5 November 2002 Resolved
Permanently repair opening in potable water tank. Clean and sanitize the interior of the tank. (Inspector to fax procedures from USPH guide) LEGACY COMPONENT DESC: Storage Tank
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Messroom
Issued 5 November 2002 Resolved
Clean bilges and deck in potable water tank void on the port side iwo beverage dispensing station (smells of rancid food material). LEGACY COMPONENT DESC: Sanitation
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Messroom
Issued 5 November 2002 Resolved
Clean exhaust vent fan, port side, IWO galley range (dirt and grease). LEGACY COMPONENT DESC: Ventilation
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Electrical › Electrical Distribution System (service)
Issued 5 November 2002 Resolved
Repair loose wiring connection to engine room exhaust fan motor. (original due date was 05DEC02, but extended to align with HO24, HO25, HO26) LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 12 December 2002
Resolved 26 November 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 5 November 2002 Resolved
Renew engine coolant hose between main engine and lower connection to expansion tank. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 5 December 2002
Resolved 12 November 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 5 November 2002 Resolved
Secure/Properly bracket small vent tubing in main engine coolant system (vents lead to expansion tank). Bungee cord is not acceptable. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 5 December 2002
Resolved 12 November 2002
Engineering › Compressed Air System (control)
Issued 5 November 2002 Resolved
Have the 3 air receiver pressure relief valves tested/certified by comp. valve shop. Valves must pop not more/less than 10% of stamped setting and not more than air receiver MAWP. LEGACY COMPONENT DESC: Valve
Due 12 November 2002
Resolved 12 November 2002
Electrical › Electric Generation Source (service)
Issued 5 November 2002 Resolved
Have generator proffesionally cleaned internally (full of oil and dirt). LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Electrical › Electrical Distribution System (service)
Issued 5 November 2002 Resolved
Have electrical distribution panels in galley cleaned internally. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Potable Water System
Issued 5 November 2002 Resolved
Repair leaking potable water pump in 3rd void forward of engineroom. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 12 November 2002
Resolved 12 November 2002
Engineering › Compressed Air System (control)
Issued 5 November 2002 Resolved
Permanently mount air compresser/receiver assy. in forward hold (and install box connector on electrical connection box. Bungee cord is acceptable. Should be hard mounted. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper Installation
Due 5 December 2002
Resolved 12 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 November 2002 Resolved
Provide 7 new Type I Cg approved, adult-size life jackets, stenciled with the vessel's name. These are to replace the seven jackets condemned at this inspection LEGACY COMPONENT DESC: Condition
Due 12 November 2002
Resolved 5 November 2002
Resolution: Master/owner/operator requested to reduce the number of passengers allowed on the vessel''''s COI in lieu of replacement.
Lifesaving › Lifebuoys
Issued 5 November 2002 Resolved
Install minimum 60 ft. of lifeline (meeting 46 CFR 180.70(c)) and one water light as required by 46 CFR 180.70(d). Vessel is limited to daylight use until float light is installed. Vessel must install the lifeline before next voyage with passengers. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 12 November 2002
Resolved 12 November 2002
Engineering › Non-conventional Propulsion/Steering
Issued 5 November 2002 Resolved
Prove proper operation of the stbd propulsion paddle wheel to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Stern Wheel
Condition: Unknown
Due 12 November 2002
Resolved 12 November 2002
Resolution: Stbd propulsion pump was re-built by commercial hydraulic repair facility. Copy of service report provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 5 November 2002 Resolved
Provide a full first aid kit per 46 CFR 184.710 that meets CG approval series 160.041 or is equivalent (inspector to fax kit description). LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 12 November 2002
Resolved 12 November 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 November 2002 Resolved
Permanently repair rot in upper deck hand rail stanchions, located as follows: on stbd side- 5th fwd of stern; on port side- 8th fwd of stern. (To be a drydock item) LEGACY COMPONENT DESC: Open Deck Space
Due 30 March 2003
Resolved 20 March 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 November 2002 Resolved
Permanently repair all rotted wood on bow ramp. This ramp will not be used by crew or passengers until corrected. (drydock item) LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Due 30 March 2003
Resolved 20 March 2003
Electrical › Electric Supply System (service)
Issued 5 November 2002 Resolved
Either rewire and reconnect the marine battery charger to batteries in the engineroom or remove all wiring and device from the vessel. LEGACY COMPONENT DESC: Battery Charger
Condition: Improper/Lack of Maintenance
Due 5 December 2002
Resolved 12 November 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 November 2002 Resolved
Install an instruction placard for the fixed CO2 system installed in the engineroom. Placard to be installed at the operating station. LEGACY COMPONENT DESC: Placard
Condition: Improper Installation
Due 5 December 2002
Resolved 12 November 2002
Engineering › Non-conventional Propulsion/Steering
Issued 5 November 2002 Resolved
Return propulsion paddle wheels (stern wheels) to original approved (original construction) arrangement by removing white vinyl fence panels and installing 2" x 12" [name withheld], ("best quality, wheel seasoned, clear, free of defects, and with grain suitable for intended purpose." LEGACY COMPONENT DESC: Stern Wheel
Condition: Improper Installation
Due 12 December 2002
Resolved 13 December 2002
Resolution: Owner/operator replaced all vinyl boards with No. 1 grade douglas fir planks (2 X 12''s).
Accommodation/Occupational Safety › Occupational Safety
Issued 5 November 2001 Resolved
Deck rail on upperdeck aft stbd quarter must be scarfed and renewed and the corner post must also be renewed. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 5 December 2001
Resolved 12 December 2001
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 November 2001 Resolved
Port side upper deck 2nd and 3rd posts forward of the stern must be renewed/reinforced to provide adequate support.
Condition: Improper/Lack of Maintenance
Due 5 December 2001
Resolved 12 December 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 5 November 2001 Resolved
Stbd side main deck forward rail and foremost post must be renewed/reinforced to provide adequate support. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 5 December 2001
Resolved 12 December 2001
Lifesaving › Lifebuoys
Issued 5 November 2001 Resolved
Renew ring buoy and waterlight mounts on port side upper deck. LEGACY COMPONENT DESC: Stowage
Condition: Improper/Lack of Maintenance
Due 5 December 2001
Resolved 12 December 2001
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 November 2001 Resolved
Renew socket cover for receptacle on upper deck aft bulkhead portside.
Condition: Improper Installation
Due 5 December 2001
Resolved 12 December 2001
Electrical › Lighting (service) › Lighting Fixture
Issued 5 November 2001 Resolved
Rewire stage spotlight in accordance with 46 CFR 183.340.
Condition: Improper Installation
Due 5 December 2001
Resolved 12 December 2001
Lifesaving › Lifebuoys
Issued 5 November 2001 Resolved
Renew retro tape on lower deck stbd side aft lifebuoy and on upper deck stbd side forward lifebuoy. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Due 5 December 2001
Resolved 12 December 2001
Lifesaving › Hand Flares
Issued 5 November 2001 Resolved
Provide distress flares and smoke signals as required by 46 CFR 180.68
Condition: Placed in Improper Service
Due 5 December 2001
Resolved 12 December 2001
Electrical › Lighting (service)
Issued 5 November 2001 Resolved
Wiring for the lower deck stbd side chandelier must be renewed to comply with 46 CFR 183.340 LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 20 December 2001
Resolved 25 June 2002
Electrical › Electrical Distribution System (service)
Issued 5 November 2001 Resolved
Replace missing junction box covers and repair damaged junction box LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 20 December 2001
Resolved 25 June 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 November 2001 Resolved
Clearly label all circuits in the distribution panel in the bar area.
Condition: Placed in Improper Service
Due 5 December 2001
Resolved 12 December 2001
Engineering › Bilge Water Management System
Issued 5 November 2001 Resolved
Replace the bilge strainers in the #4 void. LEGACY COMPONENT DESC: Strainer
Condition: Improper Installation
Due 20 December 2001
Resolved 25 June 2002
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 5 November 2001 Resolved
Make repairs to sewage tank access cover to allow for proper closure.
Condition: Improper Installation
Due 5 December 2001
Resolved 12 December 2001
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 November 2001 Resolved
Rewire wiring for security system in accordance with 46 CFR 183.340
Condition: Improper Installation
Due 5 December 2001
Resolved 12 December 2001
Engineering › Bilge Water Management System
Issued 5 November 2001 Resolved
Ensure proper operation of all submersible bilge pump float switches. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Due 20 December 2001
Resolved 25 June 2002
Engineering › Bilge Water Management System
Issued 5 November 2001 Resolved
Provide bilge high level alarms for #2 void, engine room, and port & stbd thruster spaces. LEGACY COMPONENT DESC: Interface Detector
Condition: Placed in Improper Service
Due 5 December 2001
Resolved 12 December 2001
Engineering › Steering Gear System
Issued 5 November 2001 Resolved
Provide protection from mechanical damage (e.g. chafing gear) for hydraulic hoses in planetary gear hose box. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper Installation
Due 5 December 2001
Resolved 12 December 2001
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 November 2001 Resolved
Renew all expired items in the first aid kit.
Condition: Improper/Lack of Maintenance
Due 5 December 2001
Resolved 12 December 2001
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 November 2001 Resolved
Vessel is restricted to operating with no more than one hundred twenty five (125) passengers until lifejackets in the amount shown on the vessel's Certificate of Inspection are provided. This item refers to adult passengers and lifejackets. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 5 December 2001
Resolved 12 December 2001
Resolution: [name withheld] stated that instead of purchasing the additional lifejackets to maintain his current passenger capacity he would prefer to have his COI ammended to reflect the 133 lifejackets on board. This results in new passenger capacity of 125.
Engineering
Issued 13 April 2001 Resolved
Prove operation of propulsion paddle prior to the carriage of passengers.
Condition: Unknown
Due 7 July 2001
Resolved 7 July 2001
Construction/Loadline
Issued 29 October 1999 Resolved
Remove any and all water in all compartments and ready spaces for inspection.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Construction/Loadline
Issued 29 October 1999 Resolved
Repair all internal leaking PVC piping.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Construction/Loadline
Issued 29 October 1999 Resolved
Make proper repair to diesel tank space chine damage at starboard side. Replace and repair all affected fiberglass._x001C_
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Documentation
Issued 29 October 1999 Resolved
Provide valid FCC station license or documentation from FCC removing requirement for certificate.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 29 October 1999 Resolved
Provide 3 smoke and 3 flare distress signals prior to carriage of passengers.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Construction/Loadline
Issued 29 July 1999 Resolved
MAKE PERMANENT REPAIRS TO BULKHEAD BETWEEN DIESEL COMPARTMENT AND WATER TANK COMPARTMENT, AT STARBOARD LOWER CHINE.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
MAKE PERMANENT REPAIRS TO SIDE SHELL AT STARBOARD CHINE AT BULKHEAD BETWEENDIESEL AND WATER TANK COMPARTMENTS.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
MAKE PERMANENT REPAIRS TO BULKHEAD BETWEEN WATER TANK COMPARTMENT AND SEWAGE COMPARTMENT, AT STARBOARD LOWER CHINE.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Unknown
Issued 8 July 1999 Resolved
Renew entire sheet of plywood in engine room forward stepped bulkhead. Plans are to be submitted to MSO prior to work, and be found satisfactory. Work and materials to be as original, except plywood to be marine grade.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Unknown
Issued 8 July 1999 Resolved
Clean bilges in Engine Room.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 21 October 1998 Resolved
CROP/RENEW BUCKLED/FRACTURED AREA OF FWD ENGINE COMPT. BULKHEAD. SUBMIT PLAN FOR APPROVAL PRIOR TO COMMENCING WORK.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 21 October 1998 Resolved
MARK HULL WITH DRAFT MARKS OR MAX LOADING MARK PER 46 CFR 185.604(i).
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Documentation
Issued 21 October 1998 Resolved
PROVIDE PROOF OF COMPLIANCE WITH CHEMICAL TESTING REQUIREMENTS FOUND IN 46 CFR 16.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998 Resolved
RENEW ROTTED PADDLES ON STERN WHEELS.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998 Resolved
VEE/WELD CRACKED WELDS AT STBD PROPULSION MOTOR MOUNTING ON AFT STERN FRAME.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Accommodation/Occupational Safety
Issued 21 October 1998 Resolved
REPLACE COMP. AIR DISTRIBUTION SYSTEM WITH PIPING SYSTEM MEETING 46 CFR 182.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Fire Fighting
Issued 21 October 1998 Resolved
REPLACE CURRENT FIXED EXTINGUISHING SYSTEM IN ENG. COMPT. WITH SYSTEM MEETING 46 CFR 181.410 OR 181.420.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 21 October 1998 Resolved
MAKE ALL PENETRATIONS IN EACH TRANSVERSE BULKHEAD WATERTIGHT. TAKE NOTE TO46 CFR 182.720(d)(1).
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998 Resolved
MARK STOWAGE AREAS OF LIFEJACKETS IAW 46 CFR 185.604.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998 Resolved
MARK ALL RING BUOYS W/RETROREFLECTIVE TAPE IAW 46 CFR 185.604.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Fire Fighting
Issued 21 October 1998 Resolved
PROVIDE 2 10 LB DRY CHEMICAL, UL APPROVED, A-II CLASS PORTABLE FIRE EXTINGUISHERS. MOUNT ONE IN FIRST DECK AND SECOND DECK DINING AREAS.
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Electrical
Issued 21 October 1998 Resolved
REWIRE FIXED BATTERY CHARGER IAW 46 CFR 183.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 21 October 1998 Resolved
MAKE PERM. REPAIRS TO FRACTURE LOCATED UNDER MAIN DIESEL ENGINE.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Accommodation/Occupational Safety
Issued 21 October 1998 Resolved
INSTALL DOOR KNOB OR SIMILAR LATCH ON ENGINE COMPARTMENT DOOR.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Accommodation/Occupational Safety
Issued 21 October 1998 Resolved
REPAIR LEAKING PVC JOINT ON HOT WATER HEATER IN AFT PORT QUARTER COMPT.
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Fire Fighting
Issued 21 October 1998 Resolved
CONDUCT SATISFACTORY FIRE AND MAN OVER BOARD DRILLS IN PRESENCE OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Construction/Loadline
Issued 21 October 1998 Resolved
REMOVE KRAFT PAPER FACED INSULATION (HOME CONST. GRADE) FROM ENG. COMPT. ALSO REMOVE STYRENE FOAM BOARD INSULATION FROM STORAGE DECK IN ENG COMPT._x001C_ THIS INSULATION MAY BE REPLACED W/SUITABLE MARINE GRADE, NON-COMBUSTIBLE_x001C_ W/VAPOR BARRIER._x001C_
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Accommodation/Occupational Safety
Issued 21 October 1998 Resolved
REMOVE PVC (4") PIPE DUCT LOCATED BETWEEN ENG. COMPT. AND SEWAGE COMPT. RESEAL OPENINGS IN ALL BULKHEADS WHERE DUCT PENETRATED.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998 Resolved
PROVIDE MEANS TO CLOSE OFF ALL ENGINE ROOM VENTILATION.
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Electrical
Issued 21 October 1998 Resolved
REWIRE POTABLE WATER PUMP ELECTRICAL SYSTEM IAW 46 CFR 183. (CURRENTLY_x001C_ WIRED WITH "ROMEX")
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998 Resolved
RENEW FUEL SUPPLY HOSES W/ MATERIAL MEETING SAE J1942.
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Fire Fighting
Issued 21 October 1998 Resolved
RENEW ENTIRE FIRE MAIN PIPING SYSTEM TO COMPLY WITH 46 CFR 56. SUBMIT PLANS FOR REVIEW PRIOR TO COMMENCING WORK.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 21 October 1998 Resolved
RENEW HYD. RETURN HOSE (PORT/STBD)(2 INCH) WITH MATERIAL MEETING SAE J1942.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998 Resolved
PROVIDE REPLACEMENT CG APPROVED FLOAT LIGHT IAW 46 CFR 180.70. (ATTACHED IAW 180.70(d)(3))
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Electrical
Issued 21 October 1998 Resolved
REPAIR CONNECTOR FITTINGS IN GENERATOR HOUSING AND STBD GEN BUS BOX.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Accommodation/Occupational Safety
Issued 21 October 1998 Resolved
IN COMPT FWD OF ENG COMPT, REPLACE MODIFIED PRESSURE VESSEL, SER. NO. 309509336. NEW COMPRESSOR/AIR FLASK MUST BE ASME PERMANENTLY MOUNTED AND WIRED IAW 46 CFR 183.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 21 October 1998 Resolved
PERMANENTLY WIRE HOT WATER HEATER IAW 46 CFR 183, LOCATED IN COMPT FWD OF ENG. COMPT.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Unknown
Issued 30 April 1998 Resolved
PROVIDE EVIDENCE OF DOCUMENTATION WITH "WILLAMETTE QUEEN" NAME, OR PROPERLYMARK VESSEL WITH EXISTING NAME.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Unknown
Issued 30 April 1998 Resolved
REMOVE POWER STRIP FROM BAR AREA.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Unknown
Issued 30 April 1998 Resolved
PROPERLY INSTALL DRIP-PROOF ELECTRICAL OUTLET IN BAR AREA.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Lifesaving
Issued 3 March 1998 Resolved
PRIOR TO OPERATING THE BOW EMBARKATION RAMP, MAKE PROPER REPAIRS TO THE RAMP. RAMP HAS NOT BEEN MAINTAINED AND HAS ROTTED WOOD AND LOOSE RAILS.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998 Resolved
MAKE PROPER REPAIR TO THE FRAME LOCATED IN THE BOW THRUSTER COMPARTMENT, STRB SIDE, FIRST FRAME IN BOARD OF THE STRB SIDE SHELL. FRAME HAS BECOME DISCONNECTED FROM THE BOTTOM SHELL.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Navigation
Issued 9 November 1994 Resolved
Provide deviation card.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Electrical
Issued 9 November 1994 Resolved
Hard wire carbonator w/ overcurrent protection.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Navigation
Issued 9 November 1994 Resolved
Provide tide & current tables.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Engineering
Issued 15 September 1994 Resolved
Demonstrate proper operation of propulsion system prior to carrying passengers.
Condition: Unknown
Due 15 September 1994
Resolved 16 September 1994
Construction/Loadline
Issued 22 March 1994 Resolved
PROVIDE APPROVED REVISED BILGE SYSTEM PLANS SHOWING NEW LOCATION OF BILGE MANIFOLD AND NEW PUMP.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Construction/Loadline
Issued 13 October 1993 Resolved
INSTALL BILGE MANIFOLD SYSTEM AS PER COAST GUARD APPROVED PLANS.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Construction/Loadline
Issued 13 October 1993 Resolved
SECURE FIXED BALLAST SO THAT IT CAN'T SHIFT.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Engineering
Issued 11 May 1992 Resolved
INSTALL REACH ROD, PULL CABLE OR OTHER MEANS TO OPERATE THE F/O SHUTOFF VALVE FROM OUTSIDE OF THE F/O TANK SPACE.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Electrical
Issued 22 May 1991 Resolved
INSTALL COVERS OVER BATTERIES TO PROTECT FROM DAMAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991
Unknown
Issued 22 May 1991 Resolved
PROVIDE PROOF OF INSTALLATION OF VALVES IN DISCHARGE LINES FOR BILGE PUMPS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991
Electrical
Issued 22 May 1991 Resolved
REPAIR EMERGENCY LIGHTS TO OPERATE PROPERLY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991
Documentation
Issued 22 May 1991 Resolved
PROVIDE MARPOL PLACARD FOR DISPOSAL OF GARBAGE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991
Documentation
Issued 22 May 1991 Resolved
PROVIDE PROPER ELECTRICAL DRAWINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991
Fire Fighting
Issued 22 May 1991 Resolved
PROVIDE PROOF OF SERVICING TEST OF FIXED HALON SYSTEM IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991
Navigation
Issued 22 May 1991 Resolved
PROVIDE PROPER BOW AND STERN LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1991
Resolved 22 May 1991

Casualty record · 5

19 January 2008Routine · role: Involved in a Marine Casualty · activity 3170468
18 November 2010Routine · role: Involved in a Marine Casualty · activity 3901176
13 April 2011Routine · role: Involved in a Marine Casualty · activity 3985848
9 June 2012Routine · role: Involved in a Marine Casualty · activity 4341257
4 April 2016Routine · role: Involved in a Marine Casualty · activity 5859667
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.