MAURY USCG vessel records Sign in
← All vessels

COUNTRY GIRL

COUNTRY GIRL is a 1990 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1990, most recently in April 2026, along with 135 deficiencies and 1 casualty investigation in 2025.

Records from 1990 to 2026. Most recent: inspection, 27 April 2026.

Built
1990
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAK2843
344504
Flag
UNITED STATES
367684160
Maury page id
psix-344504

Inspections, by type

…with no type recorded7
Years with a record 35 calendar years (1990–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.0 ft × 18.3 ft × 8.0 ft
Registered tonnagegross 55 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBUDDY CANNADY BOAT WORKS · MANTEO, NC, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMANTEO, NC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Simplified, Gross Ton
44 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9574MMSI 367684160 · active · compulsorily equipped · granted 7 May 2026, expires 7 May 2036
WAK2843MMSI 367028830 · expired · compulsorily equipped · granted 30 March 2005, cancelled 18 July 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

27 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8325284
5 May 2025 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8129639
3 May 2025 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8141435
9 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8099896
19 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8096196
6 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7907347
9 September 2023 Type not recorded
No type recorded · USCGC RICHARD SNYDER (WPC 1127) · USCG East District (CGD-E) · Activity 7799884
8 May 2023 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7681615
28 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7658159
11 July 2022 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7503548
11 April 2022 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7425881
31 March 2021 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7164797
9 February 2021 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7137362
7 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6998380
19 February 2020 Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6911854
14 January 2020 Special · Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6890927
30 August 2019 Type not recorded
No type recorded · USCGC RICHARD SNYDER (WPC 1127) · USCG East District (CGD-E) · Activity 6809163
12 August 2019 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6780743
20 March 2019 Annual Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6646079
11 April 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6390092
11 May 2017 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6188275
11 April 2017 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6119616
14 February 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6082267
31 July 2016 Type not recorded
No type recorded · USCGC NANTUCKET (WPB 1316) · USCG Southeast District (CGD-SE) · Activity 5965927
13 April 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5853079
20 May 2014 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4862989
5 January 2012 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4218864
10 August 2011 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4111514
29 October 2010 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3880534
1 April 2009 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3444366
12 May 2008 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3204425
11 September 2007 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3054891
4 June 2007 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2951441
10 April 2007 Hull Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2904860
5 May 2006 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2641818
6 April 2005 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2328376
9 March 2005 Hull Examination · Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2302882
7 July 2004 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2125876
10 May 2004 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2064534
2 March 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2016743
8 October 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1990554
7 May 2003 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1792600
24 March 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1763793
17 March 2003 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1759525
1 May 2002 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1606689
20 November 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1474095
19 October 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 36307
5 June 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1065293
7 May 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1408730
7 May 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1462951
6 April 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1413689
30 September 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1039481
19 May 1999 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421668
12 May 1999 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446768
11 February 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1130205
22 April 1998 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1428939
16 April 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392661
26 March 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446461
9 April 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1387974
11 April 1995 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1402015
13 March 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1432890
12 April 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1410959
18 May 1993 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 837712
28 April 1993 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 838176
20 May 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1266937
13 April 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 962301
10 October 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1249452
6 May 1991 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1000571
2 May 1990 Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1214229

Deficiency record · 135

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2026 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. The waterlight battery is expired. Replace expired battery for the ring life buoy waterlight and the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 3 June 2026
Resolution: Owner replaced the waterlights on each of the ring life buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 April 2026 Resolved
Each paddle must be lashed to the life float to which it belongs. The life float paddles were not lashed. Lash each life float paddle to which it belongs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 3 June 2026
Resolution: The life float paddles are lashed to the life floats.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 April 2026 Resolved
Each vessel must be equipped with at least two operable portable battery light. One of these light must be located at the operating station and the other at the access to the propulsion machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 3 June 2026
Resolution: A protable light is located at the operating station and at the access to the propulsion machinery space.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 April 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications. The publications (Coast Pilot [name withheld]) on board were found to be out of date. Obtain up-to-date Coast Pilot and Light List and place them on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 3 June 2026
Resolution: Up-to-date Coast Pilot and Light List are on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 April 2025 Resolved
46 CFR 179.360 (a) A hatch exposed to the weather must be watertight. Aft watertight hatch is unable to be closed, ensure the hatch can open/close and check for watertight integrity when closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 3 June 2026
Resolution: The stern watertight hatch is able to be closed and opened. A new gasket was placed around the hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2025 Resolved
46 CFR 185.604 (f) The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Lifejacket stowage needs to be labeled with the number of lifejackets being stowed in the compartment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 17 April 2025
Resolution: Received objective evidence via email that numbers were added to labels.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 April 2025 Resolved
46 CFR 180.175 (4) Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Waterlight must have battery replaced annually as per manufacturer.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 17 April 2025
Resolution: Received objective evidence via email that new batteries were purchased for the waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2025 Resolved
46 CFR 180.75 (a) Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. The vessel is restricted to carrying 28 adult passengers and 1 child passenger until life jacket lights are replaced while operating outside of the lakes bays and sounds route.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 17 April 2025
Resolution: Received objective theat owner procured new lights for lifejackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 April 2025 Resolved
46 cfr 182.520 (b) A portable hand bilge pump must be: (1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and (2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Vessels hand pump is leaking.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 17 April 2025
Resolution: Received objective evidence via email that vessel has a new hand bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 9 April 2025 Resolved
46 CFR 177.100 General requirement. The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Main deck is not supported sufficiently from below.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 17 April 2025
Resolution: Received objective evidence via email that the deck was repaired with extra support.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is missing 02 life jackets and 01 was not serviceable. Total POB reduced to 27 adults.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 8 May 2024
Resolution: New life jackets purchased and placed in service. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2024 Resolved
Flexible hoses containing fuel oil must be protected from mechanical damage. 01 fuel line on STBD MDE is chaffed/damaged. Replace in accordance with suitable hose specified in 46CFR182.720(e).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 8 May 2024
Resolution: Vessel owner replaced fuel hose. Provided documentation that hose meets SAE-J1942 standard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2023 Resolved
All electrical equipment must be protected. Install panel or drip proof protection IVO wiring on alarm panel near engine room door IAW 46CFR183.10-10.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
Resolution: Removed water line and installed covers; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2023 Resolved
Ensure breaker is labeled IVO engine room door IAW 46CFR176.25-15.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 May 2023
Resolution: Breaker properly labled; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 May 2023 Resolved
Vessel does not have adequate quantities of distress signals. Vessel must have 06 red hand flares and 06 orange smoke distress signals IAW 46CFR180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
Resolution: Vessel owner purchased appropriate amount of distress signals and placed in service; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2023 Resolved
Life ring is faded. Repair or replace IAW 46CFR180.70.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 May 2023
Resolution: New life ring placed in service aboard vessel; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2023 Resolved
Stowage areas for life jackets must be marked IAW 46CFR186.604(f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 May 2023
Resolution: Life jacket stowage has been marked.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 May 2023 Resolved
Vessel does not have chart for operating area. Provide chart IAW 46CFR184.420(A)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 May 2023
Resolution: chart purchased and placed on the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2022 Resolved
EPIRB Battery is expired replace with new. Vessel is restricted to 3NM from land. Replace to the satisfaction of CG MI in accordance with 46CFR185.728.
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 14 April 2022
Resolution: EPIRB replaced with EPIRB from the CRYSTAL DAWN. MI verified the device is now registered to the COUNTRY GIRL, all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2022 Resolved
EPIRB hydrostatic release is mismarked, updated expiry from two years before install in accordance with 46CFR1856.728.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 14 April 2022
Resolution: hydrostatic release is properly marked, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2022 Resolved
FWD high water alarm is inoperable, replace or repair prior to carrying passengers in accordance with 46CFR182.25-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 14 April 2022
Resolution: FWD high water repaired, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022 Resolved
Lifering is not properly marked and missing retro-reflective material. Mark in accordance with 46CFR182.604.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 14 April 2022
Resolution: Lifering properly marked and retro-reflective material properly applied.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 April 2022 Resolved
Provide guards/preventative measures around rotating macheinery. Port MDE belt drive and both port and starboard shaft. Install in accordance with 46CFR176.802(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 11 July 2022
Resolution: Guards fabricated and placed IVO stbd and port shaft.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 11 April 2022 Resolved
Replace/repair netting on lifefloats in accordance with 46CFR185.700.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 14 April 2022
Resolution: lifefloat netting repaired, all sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 April 2022 Resolved
Provide means of closure for all openings in the engine room compartments in accordance with 46CFR181.20-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 11 July 2022
Resolution: Vessel management procured equipment to secure ventilation to ER.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 March 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Vessel acquired 08 required flares.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 31 March 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Vessel replaced hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 March 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Vessel replaced all 03 waterlight batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Vessel replaced all lifejacket chem lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021 Resolved
FOUND RING LIFE BUOY TO BE NO LONGER SERVICEABLE. REPLACE LIFE BUOY.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Vessel replaced required lifering.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 July 2020 Resolved
Found vessel missing two hand red flares and two hand orange smoke distress signals. Vessel to procure required flares.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 7 July 2020
Resolution: Vessel procured additional red flares.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 July 2020 Resolved
Found vessels floating water light battery to be expired on the life float. Vessel to replace battery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2020
Resolved 7 July 2020
Resolution: Vessel replaced floating water light battery.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 July 2020 Resolved
Found pre engineered fire system manual pull improperly secured. Replace with correct size pin.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2020
Resolved 7 July 2020
Resolution: Proper retention pin installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2019 Resolved
Found log book missing. Procure log book.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 12 August 2019
Resolution: Logbook procured, drills to be recorded for future verification.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Risk evaluation, training and instruction to seafarers
Issued 3 April 2019 Resolved
Found DAPI proof of enrollment was not available. Provide proof of enrollment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 12 August 2019
Resolution: Found DAPI enrollment for 02 crew.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 April 2019 Resolved
Found tidal currents and light list missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 12 August 2019
Resolution: All pubs found onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2019 Resolved
Found ring lifebuoy no longer serviceable. Replace ring lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 5 April 2019
Resolution: Installed new ring lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 April 2019 Resolved
Found lifefloat improperly connected to the painter. Properly secure painter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 5 April 2019
Resolution: Properly secured painter to lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 April 2019 Resolved
Found floating water light batteries expired for life floats. Install new batteries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 5 April 2019
Resolution: Installed new batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 April 2019 Resolved
Found oars for life floats not labeled. Label oars.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 5 April 2019
Resolution: Labeled oars.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 April 2019 Resolved
Found 04 flares expired. Replace flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 5 April 2019
Resolution: Replaced flares.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 April 2019 Resolved
Found annual inspection paperwork missing for the pre-engineered system. Provide paperwork.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 12 August 2019
Resolution: Servicing report found onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 April 2019 Resolved
Found bilge high-level visual alarms inop. Repair visual indicator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 12 August 2019
Resolution: All visual indicators tested sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 3 April 2019 Resolved
Found sewage overboard valve missing securing device. Install securing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 12 August 2019
Resolution: Securing device now installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2018 Resolved
Found floating waterlight housing cracked for life float. Replace waterlight housing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: Floating waterlight was replaced.
Lifesaving › Lifefloat › Paddle
Issued 11 April 2018 Resolved
Found oars missing for one lifefloat. Procure another pair of paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: New paddles were installed.
Lifesaving › Lifefloat › Lifeline
Issued 11 April 2018 Resolved
Found weak link for the lifefloat lifeline not properly secured to the vessel. Secure lifeline weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: Secure weak ling to vessel.
Lifesaving › Hand Flares › Quantity
Issued 11 April 2018 Resolved
Found vessel missing four flares. Procure flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: Proper number of flares are on board the vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 April 2018 Resolved
Found fire equipment service in progress but not yet completed. Provide proof of fire servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 20 April 2018
Resolution: Proof of fire servicing was provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 April 2017 Resolved
Found proof of drug and alcohol testing not available. Provide proof of program enrollment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 11 May 2017
Resolution: Received proof of compliance and enrollment in APCA Drug Consortium.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 April 2017 Resolved
Found the following publications out of date: Coast Pilot [name withheld], and Tidal Currents. Procure pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 11 May 2017
Resolution: Current publications have been procured and placed aboard vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 11 April 2017 Resolved
Found charts missing. Procure charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 13 April 2017
Resolution: Purchased new charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2017 Resolved
Found medical kit missing. Procure required items.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 13 April 2017
Resolution: Purchased required items.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 11 April 2017 Resolved
Found life preserver lights expired. Install new lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 13 April 2017
Resolution: Installed new lights.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2017 Resolved
Found floating water light batteries expired on life floats. Replace batteries.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 13 April 2017
Resolution: Installed new batteries.
Lifesaving › Lifefloat › Paddle
Issued 11 April 2017 Resolved
Found oars for life floats not labeled. Label oars.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 13 April 2017
Resolution: Labeled oars.
Communications › Radio Communications › EPIRB
Issued 11 April 2017 Resolved
Found EPIRB hydrostatic release expired. Install new hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 13 April 2017
Resolution: Installed new EPIRB.
Fire Fighting › Fire Pumps › Capacity
Issued 11 April 2017 Resolved
Found fire pump not capable of producing 5 gpm. Install new pump or provide 3 fire buckets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 13 April 2017
Resolution: Procured three fire buckets.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 April 2017 Resolved
Found portable and fixed fire system (FM 200) servicing out of date. Have equipment serviced.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 13 April 2017
Resolution: Firefighting equipment was serviced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 April 2017 Resolved
Found bilge high level alarms inoperable. Repair alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 13 April 2017
Resolution: Repaired bilge alarm connector in engine room.
Documentation › Logs/Records › Logbook (official)
Issued 11 April 2017 Resolved
Found log book missing. Procure log book.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 13 April 2017
Resolution: Started new log book.
Documentation › Certificates/Documents › Stability Letter
Issued 13 April 2016 Resolved
Stability letter not on board as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: The stability letter and addendum to stability letter are both on board.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 13 April 2016 Resolved
No valid proof of drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: Proof of drug testing was provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 April 2016 Resolved
Certificate expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: Valid FCC radiotelephony safety certificate was provided as required.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 April 2016 Resolved
Vessel fitted with Class D VHF-DSC radio. Provide proof of purchase of Class A VHF-DSC radio or an exemption request seeking a "ship exemption" from FCC for carriage of Class D radio.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 18 April 2016
Resolution: Class A VHF-DSC radio was placed on board and tested as required by the FCC.
Lifesaving › Hand Flares › Expired
Issued 13 April 2016 Resolved
Night flares expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: The required number of red (night) flares were provided.
Lifesaving › Lifefloat › Serviceable
Issued 13 April 2016 Resolved
Life floats unserviceable. Apply paint, retro reflective tape and correct size weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: Life floats were painted, new retro placed on them and the proper size weak link.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 April 2016 Resolved
Not equipped with proper float light lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: Length of float light lanyard on ring buoy was made proper size.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 13 April 2016 Resolved
Portable fire extinguisher needs to be charged.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: The portable fire extinguisher that was low in charge was replaced.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 13 April 2016 Resolved
Provide emergency instructions must be posted as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: Emergency instruction were provided as required.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 April 2016 Resolved
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 18 April 2016
Resolution: Life jacket placard was provided.
Operations/Management › Vessel Activity › Other
Issued 13 April 2016 Resolved
User fees need to be paid as required by 46 CFR 2.10.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 18 April 2016
Resolution: User fees appear to be paid or in process of being paid.
Stability › Unintentional Flooding › General
Issued 20 May 2014 Resolved
Hole in shaft tube. Repair as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Resolution: Hole in shaft tube was repaired with like material and tested satisfactory.
Stability › Watertight Integrity › General
Issued 20 May 2014 Resolved
Prove proper operation of water tight hatch at aft steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Resolution: Water tight hatch was inspection and tested satisfactory.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 May 2014 Resolved
Audible alarm for pre-engineered fire system not working. Prove proper operation of this alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Resolution: Audible alarm for pre-engineered fire system was tested satisfactory.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 May 2014 Resolved
COI needs to be on board as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Resolution: COI was placed back on board as required.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2014 Resolved
Replace expired items in first aid kit or replace it.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: First aid kit was replaced with an approved one.
Lifesaving › Hand Flares › Expired
Issued 20 May 2014 Resolved
Vessel needs 6 orange or red as required and allowed by the regulations. Vessel limited to lake, bays and sounds route until cleared.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: 6 flares were replaced as required.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 May 2014 Resolved
Lifebuoy needs retro and name of vessel on it as required.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: Lifebuoy''s retro was added along with vessels name as required.
Lifesaving › Lifefloat › Retroreflective Material
Issued 20 May 2014 Resolved
Retro on life floats replace as needed.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: Retro on life floats were replaced as required.
Engineering › Bilge Water Management System › Pump
Issued 20 May 2014 Resolved
Prove proper operation of visual indicator for #1 and #3 bilge pump.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: Proved proper operation of visual indicators for #1 and #3 bilge pumps.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 May 2014 Resolved
Battery expired on Epirb, repair or replace. Vessel limited to lakes, bays, and sounds until cleared.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: Eqirb was replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 May 2014 Resolved
Hydro release expired on Epirb, replace as required. Vessel limited to lakes, bays, and sounds route until completed.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 21 May 2014
Resolution: Hydro release was replaced as required.
Stability › Watertight Integrity › General
Issued 10 April 2007 Resolved
Install watertight hatch IWO steering gear compartment (aft cockpit deck) IAW 46 CFR 171.124(a), (b) and (c) by 13MAY2007.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 4 June 2007
Resolution: Installed.
Stability › Weathertight Integrity › General
Issued 10 April 2007 Resolved
Renew WTH IWO cabin top due to broken hinges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 4 June 2007
Resolution: Renewed.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 10 April 2007 Resolved
Install flame shield IWO generator Racor fuel filter.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 27 August 2007
Personnel › Training › First Aid/CPR
Issued 10 April 2007 Resolved
Provide CPR/First Aid cards.
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 4 June 2007
Resolution: Provided.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 10 April 2007 Resolved
Upgrade fire detection system w/ visual alarms and supervised contacts.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 4 June 2007
Resolution: Installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 5 May 2006 Resolved
Install suitable vent closures IWO Engine room ventilation IAW 46 CFR 182.465(h).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 23 April 2007
Resolution: Vessel is not required to have vent closures in accordance with ABYC A-4 4.7.6.1 incorporated by reference 46CFR182.465(i).
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 March 2005 Resolved
install 2 hose clamps on each raw water hose connection on the generator's diesel eng.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 6 April 2005
Resolution: hose clamps installed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 March 2005 Resolved
NO RETRO-REFLECTIVE TAPE ON LIFEBUOY
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 6 April 2005
Resolution: Retro-reflective tape installed
Documentation › Markings/Placards › Garbage Placard
Issued 9 March 2005 Resolved
MARPOL V placard not posted
Condition: Unknown
Due 31 March 2005
Resolved 31 March 2005
Resolution: MARPOL V placard posted
Lifesaving › Lifefloat › Painter
Issued 9 March 2005 Resolved
replace frayed lifefloat line next to weak link
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 6 April 2005
Resolution: Frayed life line replaced
Engineering › Bilge Water Management System › Not Operational
Issued 11 May 2004 Resolved
Repair or replace #3 bilge pump auto visual light indicator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 7 July 2004
Engineering › Bilge Water Management System › Not Operational
Issued 11 May 2004 Resolved
Replace or repair high water bilge alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 7 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 11 May 2004 Resolved
Provide copy of service fire service report for portable fire extinguishers, fixed fire extinguishing systems and the fire and smoke detection system. Fax report to [phone withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 11 May 2004
Resolution: Service reported provied by Master. Faxed copy to [name withheld]
Documentation › Logs/Records
Issued 17 March 2003 Resolved
Provide bridge log with EPIRB test and drills logged monthly. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Navigation › Piloting/Steering
Issued 17 March 2003 Resolved
Provide current U.S. Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Navigation › Piloting/Steering
Issued 17 March 2003 Resolved
Provide current Tidal Current Tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Documentation › Markings/Placards
Issued 17 March 2003 Resolved
Post proper life jacket donning placard.
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Lifesaving › Lifebuoys
Issued 17 March 2003 Resolved
Re-new retro-reflective tape on lifebuoy ring. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 17 March 2003 Resolved
Install MSD 3/4 full indicator. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Lifesaving › Buoyant Apparatus
Issued 17 March 2003 Resolved
Re-new both (2) lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 7 May 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 17 March 2003 Resolved
Re-new mesh screen (30x30) on F/O vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 7 May 2003
Communications › Alarms/Indicators
Issued 17 March 2003 Resolved
Install/Provide bilge high level alarm with visible and audible indicators at the operating station. LEGACY COMPONENT DESC: High Water Alarm
Action required: 705 - Other - as specified
Due 25 April 2003
Resolved 7 May 2003
Lifesaving
Issued 7 May 2001 Resolved
ALL FOUR LIFEFLOAT PADDLES DRYROTTED AND CRACKED. TO BE REPLACED PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 7 May 2001 Resolved
HYDROSTATIC RELEASE ON EPIRB WAS EXPIRED. TO BE CORRECTED PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 7 May 2001 Resolved
OBTAIN 100% INFLATABLE BUOYANT APPARTUS PER 46 CFR 180.200 BASED ON VSL ROUTE AND CONSTRUCTION. AS CURRENTLY RIGGED, VESSEL SHALL ONLY OPERATE DURING WARM WATER MONTHS (01MAY-30NOV).
Condition: Unknown
Due 30 November 2001
Resolved 27 December 2001
Resolution: VESSEL OWNER ELECTED TO OPERATE VESSEL DURING WARM WATER MONTHS ONLY.
Construction/Loadline
Issued 7 May 2001 Resolved
REPAIR OR REPLACE STARBOARD ENGINE SEA SUCTION VALVE. THIS REQUIREMENT MUSTBE CORRECTED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 7 May 2001 Resolved
REPAIR 3 CRACKED GUSSETS STBD SIDE IN ENGINE ROOM ON FRAMES 3, 4, & 5 BACK FROM FORWARD BULKHEAD. REMOVE PAINT TO DETERMINE IF CRACK CONTINUES INTO FRAME. REPAIR AS NECESSARY. THIS REQUIREMENT MUST BE CORRECTED PRIOR TO THECARRIAGE OF PASSENGERS.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE THREE ADDITIONAL NIGHT FLARES.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE LIFEJACKET DONNING PLACARD THAT MATCHES LIFEJACKETS ONBOARD.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 19 May 1999 Resolved
PROVIDE LIGHT LIST, COAST PILOT AND TIDE/CURRENT TABLES.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Lifesaving
Issued 19 May 1999 Resolved
REPLACE RETROREFLECTIVE TAPE ON BOTH LIFE FLOATS. INSTALL NEW PAINTER BETWEEN FLOATS. MAKE-UP GRAB LINES ON BOTH FLOATS. REPAIR GOUGES IN FORWARD FLOAT.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Lifesaving
Issued 19 May 1999 Resolved
INSTALL MISSING WATERLIGHT FOR RING BOUY WITH 3-6 FT LANYARD AND CLIP.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Lifesaving
Issued 22 April 1998 Resolved
INCORPERATE INTO THE SAFETY BRIEFING THE PROCEDURE FOR DONNING A LIFE JACKET.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Engineering
Issued 22 April 1998 Resolved
PERMANENTLY MOUNT GENERATOR INSTRUMENT PANEL.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
PROVIDE RATED WEAK LINK FOR LIFE FLOAT.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
PERMANANTLY MARK VESSEL'S NAME ON LIFE FLOAT.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
PLACE NON CORROSIVE CLIP ON LIFE RING LIFE LINE.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Navigation
Issued 22 April 1998 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Documentation
Issued 22 April 1998 Resolved
PROVIDE LOG BOOK TO RECORD DRILLS AND EPIRB MONTHLY TEST.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
PLACE REGISTERED EPIRB BACK ON BOARD PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 22 May 1998
Resolved 7 May 1998
Lifesaving
Issued 22 April 1998 Resolved
REMOVE ALL COMBUSTIBLE/FLAMMABLES FROM ENGINE COMPARTMENT BILGE.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Engineering
Issued 28 April 1993 Resolved
INSTALL FUEL SHUTOFF ON THE DISCHARGE SIDE OF THE FUEL FILTER.
Condition: Unknown
Due 31 May 1993
Resolved 1 June 1993
Accommodation/Occupational Safety
Issued 28 April 1993 Resolved
PROVIDE/INSTALL MARPOL V PLACARD (GARBAGE).
Condition: Unknown
Due 31 May 1993
Resolved 1 June 1993
Lifesaving
Issued 28 April 1993 Resolved
STENCIL THE EMERGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 31 May 1993
Resolved 1 June 1993
Lifesaving
Issued 13 April 1992 Resolved
REPLACE OUTDATED EPIRB WITH ONE MANUFACTURED AFTER 31OCT1988.
Condition: Unknown
Due 13 April 1992
Resolved 13 April 1992
Documentation
Issued 13 April 1992 Resolved
PROVIDE EVIDENCE OF RECENT DRUG TESTING FOR ALL CREW MEMBERS.
Condition: Unknown
Due 13 April 1992
Resolved 13 April 1992
Engineering
Issued 6 May 1991 Resolved
_x001C_ REPLACE FLAME SCREENS ON STARBOARD FUEL VENTWITH 30 X 30 MESH OR CAP VENT AT FUEL TANK OR CAP OFF VENT AT FUEL TANK.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991 Resolved
PROVIDE ROTATING MACHINERY GUARD OR EXTENSION ARM FOR LEVER WHICH OPERATES LIVE BAIT WELL PUMP.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991 Resolved
_x001C_ STENCIL EPRIB WITH VESSEL NAME AND REMOUNT EPIRB TO BE FLOAT FREE.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991 Resolved
_x001C_ STENCIL RING BUOY WITH VESSEL NAME.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991 Resolved
_x001C_ PROVIDE 1 ADDITIONAL ADULT LIFEJACKET WITH LIGHT ATTATCHED AND PROVIDE ONE WATER PROOF LIGHT FOR AN ADULT LIFEJACKET.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Documentation
Issued 6 May 1991 Resolved
_x001C_ POST STABILITY LETTER ON BOASRD VESSEL.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991

Casualty record · 1

3 May 2025Routine · role: Involved in a Marine Casualty · activity 8141435
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.