MAURY USCG vessel records Sign in
← All vessels

SAMARA

SAMARA is a 1985 freight ship. The Coast Guard has recorded 7 inspections since 1990, most recently in June 2008, along with 10 deficiencies.

Records from 1990 to 2008. Most recent: inspection, 2 June 2008.

Built
1985
Last inspected
2 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8411061 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
344702
Flag
MALTA
—
Maury page id
psix-344702

Inspections, by type

…with no type recorded3
Years with a record 7 calendar years (1990–2008)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it7521 - Dead Weight, Ton
13989 - Displacement, Ton
8960 - Convention (Subpart B), Gross Ton
3339 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

2 June 2008 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3218005
31 May 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2947743
9 May 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2644516
29 August 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2179745
24 December 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 411110
14 March 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 342413
22 February 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 335448

Deficiency record · 10

Fire Fighting › Emergency Fire Pumps › Pressure
Issued 29 August 2004 Resolved
Emergency Fire Pump discharge guage broken. Repair as original. (SOLAS 74(A)II-2/21).
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 2 September 2004
Lifesaving › Launching Appliances › Winch Brake
Issued 29 August 2004 Resolved
Stbd MLB braking system not operating properly. Brake did not stop lifeboat while lowering. Class Society Surveyor to attest to proper repair and operation. (SOLAS 74(A)41.1)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2004
Resolved 2 September 2004
Lifesaving › Lifeboat › Hull
Issued 29 August 2004 Resolved
Stbd MLB port side aft hull damaged in area where hull meets davit block. Class Society Surveyor to attest to structural integrity and/or proper repairs. (SOLAS 74(A) III/41.1)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2004
Resolved 2 September 2004
Lifesaving › Launching Appliances › Block
Issued 29 August 2004 Resolved
Stbd MLB aft davit fall block outer plate damaged. Make repairs to the satisfaction of Class. (SOLAS 74(A)III/3)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2004
Resolved 2 September 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 August 2004 Resolved
Provide Approval Letter for MSD(sewage tank). Placard missing from outside of tank. (33CFR159.55)
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 2 September 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 29 August 2004 Resolved
Hole on deck just outside entrance to meat room (Reefer room # 113). Repair as original. (ILO 147)
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 2 September 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 August 2004 Resolved
Ladder leading to stbd lifeboat separating from railing near top. Repair as original. (ILO 147)
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 2 September 2004
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 29 August 2004 Resolved
All containment on deck must have mechanical means of closing. (33CFR155.310(A)(3))
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 8 May 2006
Resolution: Deficiency is not applicable to freight vessels.
Deck/Cargo › Cargo Refrigeration › General
Issued 29 August 2004 Resolved
Soft patch on sea water cooling line to refrigeration system in lower engine room. Repair to the satisfaction of Class Society Surveyor. .
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2004
Resolved 2 September 2004
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 29 August 2004 Resolved
Steering panels A & B in steering compartment missing lights on indicators. (SOLAS 74(A)V/19)
Action required: 705 - Other - as specified
Due 29 September 2004
Resolved 2 September 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.