MAURY USCG vessel records
← All vessels

CARNIVAL FANTASY

Built
1990
Last inspected
28 April 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2020
…with no type recorded37
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8700773
344935
Flag
LIBERIA
Maury page id
psix-344935

Documentation record

Tonnage as PSIX records it70367 - Convention (Subpart B), Gross Ton
44464 - Convention (Subpart B), Net Ton
37510 - Displacement, Metric Ton
6850 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 85 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 85

28 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6944887
5 April 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6935697
5 March 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6921057
9 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6905548
4 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6902475
28 January 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6897807
5 December 2019 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6863668
13 November 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6857589
10 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6831986
26 September 2019 In-Service Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6821532
12 September 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6807754
8 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6807234
7 September 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6804804
5 August 2019 In-Service Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6772208
1 August 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6773344
22 July 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6757136
22 July 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6758478
8 July 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6736959
5 July 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6813945
20 June 2019 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6688505
18 May 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6687430
19 April 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6668451
6 April 2019 Examination of Repairs · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6651986
18 March 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6656061
20 February 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6628934
15 February 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626390
15 February 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626435
20 December 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6600695
19 December 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6606758
17 December 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605905
6 December 2018 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6588212
4 November 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575686
4 November 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575845
6 October 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553052
17 September 2018 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6538793
8 September 2018 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6535129
29 August 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6543076
28 August 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6525533
14 July 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498146
5 July 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6466459
5 July 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6499113
21 June 2018 Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6435941
7 June 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6441540
19 May 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6435030
2 April 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390232
29 March 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6393268
5 March 2018 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6365836
10 February 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358250
4 January 2018 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6330163
15 December 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6416303
2 October 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6279836
9 September 2017 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6261868
9 September 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6270604
4 September 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6270596
3 August 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6229601
1 July 2017 Ballast Water Examination · Administrative Inspection · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6166283
17 June 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6188825
8 June 2017 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6166264
20 May 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6182701
15 May 2017 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6144962
2 May 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6137243
1 May 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6138097
1 May 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6173730
14 April 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6124690
13 April 2017 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6123524
13 April 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6126275
13 March 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6104045
2 February 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6088449
25 January 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6077062
19 January 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6074189
19 January 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084162
5 January 2017 COC-CVE Annual · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6065038
22 December 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6062446
24 November 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6097649
15 November 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6044079
25 October 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029359
17 October 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6023766
8 July 2016 Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5925309
5 April 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5847692
1 April 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5845078
7 March 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5828175
4 March 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5832606
22 February 2016 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5819533
3 February 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5809046
7 January 2016 ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5790338

Deficiency record · 18

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 September 2019 Resolved
Before the ship leaves port and at all time during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The No. 8 lifeboat is inoperable due to damaged fuel tank. Total persons allowed on board is reduced to 3415 until such time the No. 8 lifeboat is repaired and proven operational. SOLAS 74 (amended) III/20.2 Action Code: 50 ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2019
Resolved 12 September 2019
Resolution: Replacement lifeboat was installed, outfitted and found to be in good order to intended service. Restored total persons allowed on board to 3560.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 September 2019 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The fast recovery system for the the Number 7 life raft davit is defective. SOLAS 74 (amended) III/20.2 50 ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2019
Resolved 12 September 2019
Resolution: No. 7 crane quick recovery unit was repaired and proven operational.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 August 2019 No resolution recorded
Passenger ships of 500 gross tons and over shall carry at least one rescue boat complying with the requirements of Section 5.1 of the Lifesaving Appliance Code on each side of the ship. PSCO noted severe damage to the hull and keel of the No. 2 rescue boat.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 June 2019 Resolved
THE DOORS SHALL BE CAPABLE OF REMOTE RELEASE AND CAPABLE OF RELEASE ALSO INDIVIDUALLY FROM A POSITION AT BOTH SIDES OF THE DOOR. PSCO NOTED FIRE DOOR "915" IS INOPERABLE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 8 July 2019
Resolution: Fire door tested and found satisctory after leaks to power cylinder was repaired by ships crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 June 2019 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO NOTED LIFEBOAT #3, AND #9 NAVIGATION ALL AROUND WHITE LIGHTS WERE INOPERABLE.
Action required: 10 - Deficiency Rectified
Due 20 June 2019
Resolved 20 June 2019
Resolution: Lamps were renewed to fixtures, tested, and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY OR APPLICALBE REGULATIONS. PSCO OBSERVED ELCTRICAL INSULATION RESISTANCE INDICATED FOR SWITCHBOARD "ES2-3"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 8 July 2019
Resolution: Grounds were identified and removed. Electrical insulation resistance is now within acceptable ranges.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 June 2019 Resolved
FIRE DOORS SHALL BE CAPABLE OF REMOTE RELEASE AND CAPABLE OF RELEASE INDIVIDUALLY. PSCO NOTED FIRE DOORS THAT DID NOT PROPERLY RELEASE LOCALLY.
Action required: 10 - Deficiency Rectified
Due 20 June 2019
Resolved 20 June 2019
Resolution: Door were adjusted, tested, and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 December 2018 Resolved
The controls required for stopping oil fuel transfer pumps shall be located outside the space concerned. The newly installed F/O transfer pump for HFO was not provided with a means of stopping outside the space concerned. 74SOLAS(01) II/2/11.5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2019
Resolved 20 December 2018
Resolution: With Classification Society representative witnessed satisfactory test of port and starboard emergency stop of transfer pump located outside the space concerned. Received class report stating that they were satisfied installation and test.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 21 June 2018 Resolved
0610-lifeboats-approved means to enable persons to cling to the boat should it be upturned in the form of keel rails together with grab lines secured from gunwale to gunwale under keel or other approved arrangements shall be provided. PSCO noted that on each lifeboat the grab lines are broken or deteriorated rendering them inoperable. 74SOALS III/11(a)(xvii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 July 2018
Resolution: replaced all grab lines on all lifeboats.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2018 Resolved
0999-safety in general-marking of escape routes; the means of escape including stairways and exits shall be marked by lighting or photo luminescent strip indicators placed at all parts of the escape route. PSCO noted electrical low location lighting on deck 2 near cabins 617 & 565 were inoperable. 74SOLAS(2014) II-2/13.3.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 June 2018
Resolution: Electrician repaired the electric low location lighting strips.
Engineering › Electric Propulsion System › Feeder Circuitry
Issued 5 March 2018 Resolved
1410-Propulsion& Aux. Machinery-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceedto sea without danger to the ship or persons on board. The starboard propulsion motor failed upon entry into the Port of Mobile, Alabama.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2018
Resolved 5 March 2018
Resolution: Spare SLIO-02 module for the CPP control unit was installed and found satisfactory. Starboard propulsion system was repaired and proven operational to the Coast Guard and Lloyd's Register classification surveyor.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 13 April 2017 Resolved
1410 - propulsion main engine - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship and all respects will remain fit to proceed to sea without danger to the ship or persons on board. Starboard main engine inoperable. Prove proper operation. 74 SOLAS 14 I/11.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 April 2017
Resolution: ABB technician attended vessel and found Vector Selma Computer system CPU faulty. Replaced CPU and system was inspected and tested by ABB. System was found to be back in normal working condition.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 January 2017 Resolved
0799-Batteries shall be suitably housed in compartments used primarily for thier accomidation and properly constructed and ventilated. Batteries were stored on the ground in the battery room. 04SOLAS (97 cons) II-I/45.9.1
Condition: Improper Installation
Due 4 February 2017
Resolved 19 January 2017
Resolution: Vessel removed batteries from the deck and stored them in proper compartments.
Engineering › Steering Gear System › Motor
Issued 5 January 2017 Resolved
0936- overload alarm shall be provided for shuch sircuits and motors to protect against escess current. Overload switch not operating properly on #3 steering gear. 04 SOLAS 997 cons) II-I/30.3
Condition: Improper/Lack of Maintenance
Due 31 January 2017
Resolved 5 January 2017
Resolution: switch was replaced and tested properly. Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 January 2017 Resolved
9800-the condition of the ship and its equipment shall be maintained to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Piping serving sewage tank 2 is deteroriated and leaking. 04 SOLAS(97 cons) I/II.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 2 February 2017
Resolution: Piping serving the sewage tank #2 was renewed.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 March 2016 Resolved
1410 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. STBD shaft propellor, aft stern tube bearing is overheating causing an alarm at low RPM's. 74SOLAS(2014) CH.I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2016
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 7 March 2016 Resolved
1410 - The vessel is required to provide immediate notification to the U.S. Coast Guard if the vessel experiences a temperature outside of the operating perimeters set by the manufacturer. In addition, tug assistance will be required for inbound transit if high temperatures are experienced or if the STBD shaft is secured, size and number to the satisfaction to the Biscayne Bay Pilots.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 5 April 2016
Resolution: Vessel provided a Class report
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 22 February 2016 Resolved
1410 - The Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Starboard shaft propeller, aft stern tube bearing over heating causing a reduction in propulsion capabilities - 74 SOLAS (2014) I/11(a) - 50ac
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 29 February 2016
Resolution: Class has submitted report removing condition of class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.