CAPTAINS LADY II

CAPTAINS LADY II is a 1990 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1991, most recently in October 2025, along with 38 deficiencies.

Records from 1991 to 2025. Most recent: inspection, 2 October 2025.

Built
1990
Last inspected
2 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5638
345056
Flag
UNITED STATES
367086610, 367710610 (licence lapsed)
Maury page id
psix-345056

Inspections, by type

…with no type recorded4
Years with a record 33 calendar years (1991–2025)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)76.0 ft × 21.0 ft × 6.5 ft
Registered tonnagegross 69 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS OF STUART INC · STUART, FL, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWBURYPORT, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Simplified, Gross Ton
55 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5638MMSI 367710610 · expired · compulsorily equipped · granted 14 January 2016, cancelled 21 March 2026
WDC8411MMSI 367086610 · expired · compulsorily equipped · granted 12 January 2006, cancelled 19 March 2016
WAO5604MMSI not assigned · expired · compulsorily equipped · granted 1 June 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 65

2 October 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8240939
9 December 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8039587
24 September 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8003191
28 September 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7787622
8 June 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7709524
2 May 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668525
5 December 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7592859
22 September 2022 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7546347
7 October 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7327494
4 November 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7094115
15 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7077195
10 October 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6833040
25 October 2018 Drydock Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6567845
10 October 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6558185
12 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6539041
25 September 2017 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6272479
19 July 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6213642
20 December 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6069391
24 October 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6028197
15 October 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5742997
8 October 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5001974
7 June 2012 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4337630
5 June 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4334680
12 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206290
13 December 2010 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3909803
7 October 2010 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3865856
7 November 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3369051
16 October 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3345771
25 September 2007 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3065763
23 January 2007 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2860479
23 October 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2806142
11 October 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2511644
14 March 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2309545
15 October 2004 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2221316
7 October 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1922828
10 March 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1754968
23 September 2002 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1679118
8 April 2002 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1602380
11 October 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1454985
12 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1062136
2 October 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1461321
23 September 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1375910
24 March 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1121541
23 November 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 806452
28 September 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 798844
14 January 1998 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1108587
16 October 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1111048
9 December 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1442490
22 October 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1159685
24 September 1996 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1143513
26 September 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 879662
26 October 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1171117
5 October 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1171361
27 September 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 867838
6 September 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 4473
13 December 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 849248
30 September 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 835082
30 September 1993 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1143556
30 September 1993 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1155465
26 October 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957498
26 October 1992 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1134040
1 October 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268557
24 September 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 961882
4 November 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1252852
22 March 1991 Hull Examination · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 908699

Deficiency record · 38

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 October 2018 Resolved
Where cable protection is carried through watertight decks or bulkheads, installation shall be such that will ensure watertight integrity of the structure. Multiple penetrations through the bulkhead in the engine room. 46 CFR 183.20-20
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 3 December 2018
Resolution: Bulkhead penetrations were filled with a fire retardent foam
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 10 October 2018 Resolved
During inspection, spaces may be examined to determine that they are servicerable. Water tank in void #3 has a hole.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 3 December 2018
Resolution: New water tank was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2018 Resolved
Each hatch exposed to the weather must be watertight. Forward hatch is letting water into the space. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2018
Resolution: Replaced gasket
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 10 October 2018 Resolved
When life floats are stowed in tiers, the separate units must be kept apart by spacers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2018
Resolution: Inserted wood spacers inbetween the life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 October 2018 Resolved
A vessel of more than 65 ft. must carry at least one rescue boat or the OCMI determines that vessel is sufficiently equipped to allow the crew to recover a helpless person in the water. Provide acceptable means to recover helpless person in the water.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2018
Resolution: Vessel provided ladder with rescue platform
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 September 2017 Resolved
Provide proof of drug and alcohol testing for all employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 25 October 2018
Resolution: Provided proof of drug testing for all crewmembers
Engineering › Bilge Water Management System › Interface Detector
Issued 25 September 2017 Resolved
Provide labeling for each compartment on bilge high level alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2017
Resolved 13 October 2017
Resolution: Bilge alarm panel was properly labeled.
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2017 Resolved
Prove proper operation of engine room audible alarm for bilge high level panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2017
Resolved 13 October 2017
Resolution: Engine room high level alarm was found to be functional.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 October 2016 Resolved
Vessel rep did not have the Certificate of Documentation for the inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 25 October 2016
Resolution: Vessel rep. provided COD.
Engineering › Steering Gear System › Rudder Bearing
Issued 24 October 2016 Resolved
Shaft packing on rudder posts were leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 19 July 2017
Resolution: Received attestation from vessel's owner that one packing had been adjusted and the other replaced.
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 24 October 2016 Resolved
Life jackets need to be labeled with the ship's name.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 19 July 2017
Resolution: Received photo and owner's attestation to properly labeled PFDs.
Engineering › Fuel Oil Service System › Piping
Issued 15 October 2015 Resolved
F/O fill pipe has hose section that is not grounded.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 8 January 2016
Resolution: New grounding wire was installed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 October 2015 Resolved
Engineroom emergency escape was not marked on the inside of the hatch.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 8 January 2016
Resolution: New signs were attached both inside and outside of engine room hatch.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 15 October 2015 Resolved
BA has failed retro, and broken grablines.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 8 January 2016
Resolution: New life lines and retro tape was installed on all life floats.
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2011 Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 136 PERSONS(PASSENGERS AND CREW)
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 5 June 2012
Resolution: Weight ratio has been done and total persons has gone to 136.
Lifesaving › Hand Flares › Expired
Issued 25 September 2007 Resolved
Expired flares
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2007
Resolved 27 September 2007
Resolution: New flares procured
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2007 Resolved
Broken wire on tank room bilgfe high level alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2007
Resolved 27 September 2007
Resolution: New wire installed and tested alarm.
Communications › Radio Communications › EPIRB
Issued 25 September 2007 Resolved
Epirb hydrostatic release expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2007
Resolved 27 September 2007
Resolution: New hydo release procured and installed
Communications › Radio Communications › EPIRB
Issued 7 October 2003 Resolved
Renew hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 15 October 2004
Lifesaving › Buoyant Apparatus › Painter
Issued 7 October 2003 Resolved
Provide a second painter and weak link for lifefloats, or provide evidence that all 8 rafts have a combined weight of less than 40 pounds.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 15 October 2004
Operations/Management › Drills/Instruction › Fire
Issued 7 October 2003 Resolved
Prior to next operating season, conduct fire and man overboard drills in the presence of a marine inspector.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 1 June 2004
Accommodation/Occupational Safety
Issued 11 October 2001 Resolved
Make crew quarters emergency escape hatch operable.
Condition: Unknown
Due 1 May 2002
Resolved 1 April 2002
Resolution: Properly repaired crew quarter emergency escape hatch.
Lifesaving
Issued 11 October 2001 Resolved
Prior to operating during 2002 season, conduct satisfactory fire and man overboard drills in the presence of Marine Inspector.
Condition: Unknown
Due 1 May 2002
Resolved 1 April 2002
Resolution: Conducted satisfactory fire and man overboard drills in the presence of a marine inspector.
Fire Fighting
Issued 11 October 2001 Resolved
Service vessels fixed CO2 fire extinguishing system that serves engine room.
Condition: Unknown
Due 1 May 2002
Resolved 1 April 2002
Resolution: CO2 system has been properly serviced.
Fire Fighting
Issued 2 October 2000 Resolved
PRIOR TO OPERATING NEXT SEASON, PROVIDE ACCEPTABLE STORAGE BOX TO KEEP 1 1/2 INCH FIRE HOSES PERMANENTLY ATTACHED TO THE STATION.
Condition: Unknown
Due 2 October 2000
Resolved 2 October 2000
Lifesaving
Issued 2 October 2000 Resolved
PROVIDE REGISTRATION STICKER FOR THE EPIRB BY 9 OCT OO.
Condition: Unknown
Due 9 October 2000
Resolved 26 October 2000
Fire Fighting
Issued 23 September 1999 Resolved
LOCAL CO2 CYLINDER RELEASE MOUNTED FACING THE BULKHEAD. PROPERLY MOUNT CONTROL DEVICE ON THE CO2 CYLINDER.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 23 September 1999 Resolved
POST COMPLETE BUT SIMPLE INSTRUCTIONS FOR THE OPERATION OF THE FIXED GAS FIRE EXTINGUISHING SYSTEM AT OR NEAR EACH PULL BOX AND STOP VALVE CONTROL IN THE SPACE WHERE THE CYLINDERS ARE STORED. IN ACCORDANCE WITH 46CFR 185.612.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Lifesaving
Issued 23 September 1999 Resolved
PROVIDE US COAST GUARD FIRST AID KIT ON BOARD THE VESSEL.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Construction/Loadline
Issued 23 November 1998 Resolved
PORT AND STBD EXHAUST COOLING OVERBOARD THROUGH HULL GATE VALVE SEATS AND DISCS DAMAGED. VALVES RENEWED.
Condition: Unknown
Due 25 November 1998
Resolved 24 November 1998
Lifesaving
Issued 16 October 1997 Resolved
Properly register and mount new 406Mhz EPIRB in accordance with 46CFR 180.64_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
Renew life float painter.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Navigation
Issued 16 October 1997 Resolved
Post a durable placard next to all radio telephone installations with the emergency broadcast instructions and information specific to the individualvessel. See 184.510.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Navigation
Issued 24 September 1996 Resolved
PROVE PROPER OPERATION OF STERN LIGHT.
Condition: Unknown
Due 1 October 1996
Resolved 15 October 1996
Documentation
Issued 24 September 1996 Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE DRUG TESTING PROGRAM REQUIREMENTS CONTAINED IN 46 CFR PART 16 AND 49 CFR PART 40.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Lifesaving
Issued 24 September 1996 Resolved
RENEW EPIRB BATTERY DUE TO EXPIRE ON 30 SEP 1996.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Lifesaving
Issued 24 September 1996 Resolved
INSTALL RETRO REFLECTIVE TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Documentation
Issued 30 September 1993 Resolved
PROVIDE SATISFACTORY EVIDENCE THAT CHEMICAL TESTING REQUIRED BY 46 CFR PART16 IS BEING CONDUCTED OF VESSEL'S CREW NO LATER THAN 31OCT93.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.