Inspection record

Last inspected 1 August 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

345157
Flag
UNITED STATES
Maury page id
psix-345157

Documentation record

Tonnage as PSIX records it37 - Simplified, Gross Ton
30 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

1 August 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972465
25 May 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7199302
26 January 2021 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7131271
20 May 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953649
27 February 2020 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6921573
22 February 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6630671
4 August 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6502627
10 May 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6526795
3 May 2018 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6400683
15 March 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6100666
22 April 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6315185
19 April 2016 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5857886

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 November 2021 Resolved
A dry exhaust pipe must be kept clear from and suitabliy insulated or shielded from, combustable material. Part of the exhaust lagging was missing after the piping was replaced. 46 CFR 182.430(g)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 25 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 10 November 2021 Resolved
A hatch exposed to the weather must be watertight. The gasket on the hatch leading to the lazerette no longer provides a watertight seal. 46 CFR 179.360(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 25 January 2022
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 January 2021 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Improperly installed mechanically remote fuel shut-off valve cabling to fuel supply valves located after both fuel Racor filters. Re-locate and install remote shut off valve cabling at fuel tank main supply valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 12 March 2021
Resolution: Pics sent via email. Def rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2020 Resolved
COMPLETE ANNUAL SERVICE FOR PORTABLE FIRE EXTINGUISHERS AND FIXED CO2 FIRE FIGHTING SYSTEM.
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 1 June 2020
Resolution: Recieved service report.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 May 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 15 June 2020
Resolution: Pictures received.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 May 2020 Resolved
PROVIDE MACHINERY GUARD OVER PTO PUMP BELT AT FORWARD END OF STARBOARD PROPULSION ENGINE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 15 June 2020
Resolution: Pictures received.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 February 2019 Resolved
Repair or renew small 45 degree elbow on the port main engine raw water suction line. (small pin hole leak)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 February 2019 Resolved
Renew all 4" flexible pipe on both port and starboard main engine at the suction strainer
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 February 2019 Resolved
Repair fiberglass stringer in the engine room IWO starboard side bilge and the first frame from forward bulkhead.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 28 February 2019 Resolved
Re-attach portside fuel tank support brackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 February 2019 Resolved
Renew ball joints on steering jockey bar and properly maintain. (found metal shavings)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 February 2019 Resolved
Prove proper operation on starboard main engine lube oil gauge.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2019 Resolved
Tighten packing on portside rudder post.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 1 April 2019
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 March 2017 Resolved
Fire extinguisher located in aft cabin needs proper securing bracket.
Due 15 April 2017
Resolved 27 June 2017
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 22 April 2016 Resolved
Prove proper operation of strut bearing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2016
Resolved 26 April 2016
Resolution: Repaired strut bearing, sea trials conducted.

Ownership record