Records from 1990 to 2025. Most recent: inspection, 18 August 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
18 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8212395
25 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7942313
22 May 2023
Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694125
22 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7483450
10 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7193625
26 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6725383
28 March 2018
Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6379800
17 April 2017
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6126484
4 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5847297
26 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4822836
15 December 2011
Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4207972
27 December 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3916606
18 March 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3698355
6 March 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3428577
21 March 2008
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3168774
12 March 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2886196
19 April 2006
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2628180
25 February 2004
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2012799
14 March 2003
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1815063
24 October 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370390
2 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451592
12 March 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442799
13 March 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364569
18 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441166
16 May 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082546
15 March 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467918
6 March 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424136
4 February 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415942
15 October 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462357
31 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1137412
3 February 1993
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465097
2 March 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268903
2 April 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225040
2 March 1990
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909627
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2024
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Vessel did not have the number of child size life jackets equal to at least 10% of the number of persons permitted on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 August 2025
Resolution: Vessel had proper number of child-sized life vests on board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 June 2024
Resolved
Each ring buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel did not have the vessel's name on the ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 16 September 2025
Resolution: Vessel rep marked ring buoy with vessel name in block capital letters.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 May 2023
Resolved
Fire extinguishers required on a vessel must be acceptable to the [name withheld] extinguisher was out of service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: Verified vessel has fire extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 May 2023
Resolved
A vessel on lakes, bays, and sounds, or rivers route must carry 06 flares. All flares on vessel were expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: Verified vessel has flares.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 22 May 2023
Resolved
On a vessel of not more than 65’ in length, a battery powered bullhorn may serve as the PA. Vessel carries more than 49 passengers needs to have a PA.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 21 June 2023
Resolution: Verified vessel has bullhorn for use as PA system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2019
Resolved
03 Adult Lifejackets and 03 Children Lifejackets beyond their service life. Lifejackets will need to be replaced. Reducing Passenger count to 65 until replaced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 7 October 2019
Resolution: Contacted VSL rep to confirm that own purchased 03 Adult Lifejackets and 03 Children Lifejackets for the VSL. Passenger count returned to 68, deficiency cleared.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 March 2018
Resolved
Provide lifejacket donning placard
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 17 April 2018
Resolution: Cleared by attending CG inspector.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 April 2017
Resolved
Missing 02 PFD's, reduced totals persons allowed to 66 until required quantity onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 21 April 2017
Resolution: Addtional life jackets provided
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 April 2017
Resolved
Fire extinguisher due for annual service/inspection. April 2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 21 April 2017
Resolution: Extinguisher serviced.
Lifesaving › Hand Flares › Expired
Issued 4 April 2016
Resolved
5 flares were expired. Required vessel rep to provide sufficent flares.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2016
Resolved 7 April 2016
Resolution: Recieved reciept from zams clearing all discrepant items in their fleet.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 April 2016
Resolved
extinguisher was past it's annual service window. required vessel rep to provide reciept for service of the extinguisher
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2016
Resolved 7 April 2016
Resolution: vessel rep provided reciept for service of extinguisher
Lifesaving › Lifebuoys › Serviceable
Issued 4 April 2016
Resolved
ring buoy plug was punctured. required vessel rep to provide a servicable ring buoy.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2016
Resolved 7 April 2016
Resolution: vessel rep provided reciept for new ring buoy.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 April 2016
Resolved
vessel did not have emergency instruction onboard
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 April 2016
Resolution: vessel rep provided satisfactory emergency instruction prior to departure of CGMI
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2016
Resolved
no drills were being logged or conducted.
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 April 2016
Resolution: prior to departure ran drills with vesel rep and master, provided guidance they used to establish drill log
Fire Fighting › Fire Bucket › Availability
Issued 26 March 2014
Resolved
vessel was missing 3 fire buckets.
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 1 April 2014
Resolution: Operator sent MSU Houma reciepts and pictures of the new fire buckets onboard the vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 March 2014
Resolved
The B-1 fire extinguisher on board was out of the required pressure range and was corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 27 March 2014
Resolution: Owner provided proof of new extinguisher purchased.
Lifesaving › Hand Flares › Expired
Issued 26 March 2014
Resolved
vessel had 1 red hand flares expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 27 March 2014
Resolution: Owner provided proof of purchase of new hand flares.
Lifesaving › Hand Flares › Expired
Issued 27 December 2010
Resolved
All six red hand flares expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Resolution: Purchased six new red hand flares.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 December 2010
Resolved
SOLAS approved tape wasted on life jackets including child-size life jackets, correct as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Resolution: Replaced approved reflective type onto life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 December 2010
Resolved
Required life jacket donning placard for each type of life jacket onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2010
Resolution: Two types of life jacket donning placards posted visible to all passengers and crew.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 December 2010
Resolved
Required to service fire fighting extinguishers annually. Need fire fighting annual service certification.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Resolution: Serviced fire extinguisher.
Communications › Audible Communications › Horn/Whistle
Issued 6 March 2009
Resolved
Vessel had no horn on board
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2009
Resolution: Air horn purchased
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 March 2009
Resolved
Fire extinguisher needs to be serviced or replaced
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2009
Resolution: Rcvd fax confirmation that fire extinguisher had been serviced.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 6 March 2009
Resolved
Portable fuel tank needs to be secured on fan tail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2009
Resolution: Fuel tank secured
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 March 2009
Resolved
Battery needs to be secured on fan tail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 12 March 2007
Resolved
Service all portable fire extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2007
Resolution: Portable fire extinguishers were serviced by local safety company.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 March 2007
Resolved
Label toilet as out of service.
Due 12 April 2007
Resolved 16 April 2007
Resolution: Toilet labeled as out of service.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 19 April 2006
Resolved
Missing PFD donning placard for one style of PFD being carried.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2006
Resolved 3 May 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 April 2006
Resolved
Separate adult/childrens PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2006
Resolved 3 May 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 April 2006
Resolved
Life ring buoy needs new retro tape and vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2006
Resolved 3 May 2006
Lifesaving › Hand Flares › Expired
Issued 18 April 2006
Resolved
Replace all expired flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2006
Resolved 3 May 2006
Lifesaving › Lifejacket/PFD (General)
Issued 20 February 2004
Resolved
Stencil Life ring with vessel's name. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Stenciled life ring.
Lifesaving › Buoyant Apparatus
Issued 20 February 2004
Resolved
Attach life line to life ring. LEGACY COMPONENT DESC: life ring life line
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Attached life line.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 20 February 2004
Resolved
Conduct annual fire extinguisher inspection. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Inspected fire extinguisher.
Lifesaving › Lifejacket/PFD (General)
Issued 20 February 2004
Resolved
Stencil life jacket locker. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 1 April 2004
Resolution: Stenciled life jacket locker.
Lifesaving › Lifejacket/PFD (General)
Issued 20 February 2004
Resolved
Provide and install life jacket donning placard. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Mounted life jacket donning placard.
Lifesaving › Hand Flares
Issued 20 February 2004
Resolved
Provide and install 3 red and 3 orange flares on board. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 25 March 2004
Resolution: Provided flares.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 March 2003
Resolved
Provide new reflective material on all lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2003
Resolved 21 March 2003
Construction/Loadline › Hull › Weld
Issued 14 March 2003
Resolved
Reweld 5 fractured welds on the stern of the vsl.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2003
Resolved 21 March 2003
Fire Fighting
Issued 18 February 1997
Resolved
SERVICE FIRE EXT.
Condition: Unknown
Due 18 February 1997
Resolved 20 February 1997
Unknown
Issued 15 March 1996
Resolved
Provide written chemical drug testing program policy as per 46 CFR part 16.Policy to include preemployment, random, and accident drug testing. Also toinclude employee assistance program and record keeping, etc.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Lifesaving
Issued 15 March 1996
Resolved
Provide vessel name stenciled on all life preservers.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 15 March 1996
Resolved
Relocate engine starting batteries in engine mounting bay to be clear of accumulated water and secure to prevent movement. Provide battery boxes with covers.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996