RAIN is a 1990 tank ship. The Coast Guard has recorded 44 inspections since 1990, most recently in April 2003, along with 38 deficiencies and 1 operational control.

Records from 1990 to 2003. Most recent: inspection, 8 April 2003.

Built
1990
Last inspected
8 April 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8819196 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
345486
Flag
LIBERIA
—
Maury page id
psix-345486

Inspections, by type

…with no type recorded28
Years with a record 12 calendar years (1990–2003)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29998 - Dead Weight, Ton
10084 - Regulatory (Subpart C or D), Net Ton
18033 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

8 April 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1770329
26 March 2003 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1770272
5 March 2003 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1752984
22 March 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1495859
14 March 2002 Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1493564
12 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 209961
12 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 768377
31 January 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 286661
23 January 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 286351
11 January 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1056530
31 August 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 147584
28 January 2000 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 273901
8 March 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 426315
7 January 1999 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 424116
7 January 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 809652
16 November 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 422830
4 February 1998 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 452858
25 September 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 647240
11 September 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 407667
7 April 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 510042
25 February 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 484812
30 December 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 399466
30 December 1996 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102059
30 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1106924
23 September 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 370698
23 September 1994 Letter of Compliance (Initial/Renewal) · MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864370
22 September 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1180998
1 April 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 856575
4 March 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 855857
26 February 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 364901
8 January 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 364093
8 January 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1165135
20 April 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 647242
22 March 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 349524
22 March 1992 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1263276
22 March 1992 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1403528
10 December 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 497505
7 May 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 343610
7 May 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 908097
30 October 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 515041
4 September 1990 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1240599
20 March 1990 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 335852
20 March 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930747
20 March 1990 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931378

Deficiency record · 38

Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 8 April 2003 Resolved
Classification Society markings (DNV) on loadline were painted over the existing Classification letters (NKK) instead of being ground in or welded permanently to the hull.
Condition: Improper/Lack of Maintenance
Due 31 May 2003
Resolved 16 October 2024
Resolution: cleared
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 April 2003 Resolved
Flame screens dirty or wasted on Fuel vents.
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 8 April 2003
Resolution: Inspected proper repairs to all flame screens.
Deck/Cargo › Holds/Tanks
Issued 8 April 2003 Resolved
Make permanent repairs to butterworth openings, Install new rubber gaskets where needed, replace worn bolts, tighten existing bolts, and ensure vapor tight. LEGACY COMPONENT DESC: Ullage
Condition: Improper/Lack of Maintenance
Due 27 April 2003
Resolved 8 April 2003
Resolution: Proper repairs and corrections made to all ullage, butterfly openings and deck covers.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 8 April 2003 Resolved
Make permanent repairs to lower sight glass water indicator valve on deck water seal tank.
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 8 April 2003
Resolution: Inspected proper repairs to the lower sight glass water indicator valve.
Construction/Loadline › Structures › Door
Issued 8 April 2003 Resolved
Ensure 2nd deck stbd side and all exterior hatch's are weathertight.
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 8 April 2003
Resolution: Inspected repairs of all weather tight hatches, all satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 April 2003 Resolved
Install lighting fixture globe guards to all exposed exterior glass lights.
Condition: Improper/Lack of Maintenance
Due 8 April 2003
Resolved 8 April 2003
Resolution: Inspected all installations of exterior deck lights, all found satisfactory.
Deck/Cargo › Vapor Control Systems
Issued 14 March 2002 Resolved
Paint and label the last 1 meter of vapor line in accordance with 46 CFR 39.20 (d).
Due 14 April 2002
Resolved 21 March 2002
Resolution: Vapor line painted in accordance with CFR 46.
Pollution Prevention/Response › Prevention Equipment
Issued 14 March 2002 Resolved
Liquid overfill alarms on deck cannot be seen on the cargo deck. Relocate alarms so they maybe seen in accordance with 46 CFR 39.20-7 (d) (2) & (3). LEGACY COMPONENT DESC: Cargo Monitor/Control System
Due 14 April 2002
Resolved 21 March 2002
Resolution: Alarms lights raised 2 meters.
Lifesaving › Lifeboat
Issued 14 March 2002 Resolved
Clean off the windows of the lifeboats so the boats maybe navigated from inside. LEGACY COMPONENT DESC: View (at steering position)
Due 14 April 2002
Resolved 21 March 2002
Resolution: Windws cleaned.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System
Issued 14 March 2002 Resolved
Make permanent repairs to hole in foam line leading to the aft port canon near centerline. LEGACY COMPONENT DESC: Piping
Due 14 April 2002
Resolved 21 March 2002
Resolution: Corroded foam line replaced with new section of pipe.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 14 March 2002 Resolved
Cargo pump #4 has a bad seal. Vessel may not use cargo pump until proper repairs have been examined by class. LEGACY COMPONENT DESC: Cargo Pump
Due 14 April 2002
Resolved 21 March 2002
Resolution: New seals installed on #4 cargo pump.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 March 2002 Resolved
Make pumproom safe for entry by Marine Chemist so that US Coast Guard may examine pumproom. Pumproom is contaminated with cargo and cannot be examined. LEGACY COMPONENT DESC: Contaminated atmosphere
Due 14 April 2002
Resolved 21 March 2002
Resolution: Pumproom safe for empty and cleaned.
Personnel › Training
Issued 14 March 2002 Resolved
Conduct satisfactory fire drill in the presence of USCG Inspector. LEGACY COMPONENT DESC: Fire Fighting Basic
Due 14 April 2002
Resolved 14 March 2002
Personnel › Training
Issued 14 March 2002 Resolved
Conduct satisfactory abandon ship drill in the presence of USCG Inspector. LEGACY COMPONENT DESC: Abandon Ship Drills
Due 14 April 2002
Resolved 14 March 2002
Lifesaving › Lifeboat
Issued 14 March 2002 Resolved
Provide fenders for stbd lifeboat. LEGACY COMPONENT DESC: Fender
Due 14 April 2002
Resolved 21 March 2002
Resolution: fenders installed.
Fire Fighting
Issued 23 January 2001 Resolved
REPLACE TACHOMETER ON EMERGENCY FIRE PUMP ENGINE.
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Fire Fighting
Issued 11 January 2001 Resolved
Repair/replace tachometer on emergency firepump engine.
Condition: Unknown
Due 11 January 2001
Resolved 11 January 2001
Fire Fighting
Issued 28 January 2000 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP (REPALCE BATTERY)
Condition: Unknown
Due 28 January 2000
Resolved 31 January 2000
Deck/Cargo
Issued 28 January 2000 Resolved
PROVE PROPER OPERATION OF HIGH LEVEL ALARM (VISUAL)
Condition: Unknown
Due 28 January 2000
Resolved 31 January 2000
Navigation
Issued 28 January 2000 Resolved
PROVE PROPER OPERATION OF GMDDS RADIO (REPLACE BATTERY)
Condition: Unknown
Due 28 January 2000
Resolved 31 January 2000
Deck/Cargo
Issued 7 January 1999 Resolved
CARGO PIPING MARKED WITH TEST PRESSURE, MARK PIPING WITH MAWP. TO BE CLEARED BEFORE NEXT U.S. PORT. (TO COLD TO PAINT)
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Lifesaving
Issued 7 January 1999 Resolved
SOLAS 74 II-1, REG 45 (2) RUBBER MAT MISSING BEHIND MAIN SWITCHBOARD, INSTALL MAT.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Deck/Cargo
Issued 11 September 1997 Resolved
THE PIC FOR THE VESSEL SIGNED THE DOI WITHOUT INSPECTING ALL ITEMS LISTED ON THE DOI.
Condition: Unknown
Due 11 September 1997
Resolved 25 September 1997
Navigation
Issued 30 December 1996 Resolved
MAGNETIC COMPASS WAS NOT ILUMINATED.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Fire Fighting
Issued 30 December 1996 Resolved
FIRE HOSE ON FOCS'LE WAS WASTED.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Navigation
Issued 8 January 1994 Resolved
ECHO DEPTH SOUNDER RECORDER NOT OPERATION PROPERLY.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Navigation
Issued 8 January 1994 Resolved
ECHO DEPTH SOUNDER NOT OPERATING PROPERLY.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Navigation
Issued 8 January 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Navigation
Issued 8 January 1994 Resolved
LIGHT LIST FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Documentation
Issued 8 January 1994 Resolved
MAKE THE PUMPROOM AVAILABLE FOR INSPECTION BY HAVING IT CERTIFIED GAS FREE BY A MARINE CHEMIST, AT NEXT U.S. PORT. CONTACT THE LOCAL COAST GUARD OCMI TO SCHEDULE THE INSPECTION.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Construction/Loadline
Issued 8 January 1994 Resolved
REPAINT THE VESSEL'S LOAD LINE MARKS PRIOR TO RETURN TO US WATERS.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Lifesaving
Issued 8 January 1994 Resolved
PROVE PROPER OPERATION OF EXPLOSIVE METER WITH SPAN GAS UPON RETURN TO US WATERS.
Condition: Unknown
Due 8 February 1994
Resolved 8 March 1994
Construction/Loadline
Issued 8 January 1994 Resolved
MAKE PROPER REPAIRS TO WASTED DOGGING DEVICE TO WATER TIGHT DOOR ON 02 DECKSTARBOARD SIDE PRIOR TO RETURN TO US WATERS.
Condition: Unknown
Due 8 February 1994
Resolved 8 March 1994
Deck/Cargo
Issued 8 January 1994 Resolved
PROVIDE PERMANENT REPAIRS TO THE SCRUBBER DISCHARGE LINE WHERE WASTED TO THE SATISFACTION OF THE CLASS SOCIETY PRIOR TO 31 MARCH 94 PER CLASS SOCIETY REQUIREMENT.
Condition: Unknown
Due 31 March 1994
Resolved 8 March 1994
Fire Fighting
Issued 8 January 1994 Resolved
PROVIDE NEW GLOVES AND HATS FOR TWO FIREMEN'S OUTFITS ON BOARD PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 8 February 1994
Resolved 8 March 1994
Navigation
Issued 22 March 1992 Resolved
FOR AREA TO BE TRANSITTED, A CURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT OF THE US COAST PILOT. _x001C_ 33 C.F.R. 164.33(a)(2)(i)_x001C_ _x001C_
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 7 May 1991 Resolved
46 CFR 35.30-10 No cargo tank hatches, ullage holes, or Butterworth plates shall be opened or shall remain open without flame screens, except under the supervision of the senior members of the crew on duty, unless the tank opened is gas free. _x001C_
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Documentation
Issued 20 March 1990 Resolved
49CFR176.30(A)THE CARRIER SHALL PREPARE A DANGEROUS CARGO MANIFEST, LIST OR STOWAGE PLAN. THIS DOCUMENT MUST BE KEPT IN A DESIGNATED HOLDER ON OR NEAR THE VESSELS BRIDGE.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.