Records from 1990 to 2025. Most recent: inspection, 12 March 2025.
Inspection history · 38
12 March 2025
PSC A
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090089
23 May 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5881148
3 October 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4993875
17 August 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4110091
29 April 2009
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3459697
23 May 2008
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3209087
23 May 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3219510
21 April 2004
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2041040
20 April 2004
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2054623
16 April 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2053777
6 July 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 292007
6 July 2001
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1067109
21 June 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 279176
8 November 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486738
17 April 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 427949
17 April 1999
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 791424
8 March 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 413381
8 March 1998
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1408062
28 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 394663
14 February 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388121
8 September 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 538254
22 January 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 438553
19 September 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 510676
15 August 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 704309
28 February 1994
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1164335
27 February 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 107175
25 October 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457115
7 March 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 832617
5 March 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 453480
22 October 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 524864
23 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 449197
8 February 1992
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 954550
7 December 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 518326
15 August 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 518396
22 January 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341243
22 January 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 907458
17 November 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 503395
22 March 1990
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 903658
Electrical › Electrical Distribution System (service) › Cable
Issued 3 October 2014
No resolution recorded
Electrical installations shall be such that appropriate steps are taken to ensure unifiormity in the implementation and application in respect to electrical installations. Numerous electricalcable runs in the engine room that pass through class A boundaries appear to have improper packing insulation. 74 SOLAS (09) II-1/40.2 action taken 40a
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 October 2014 — due date passed with no resolution recorded
Engineering › Steering Gear System › Valve
Issued 21 April 2004
Resolved
Repair leaking valve on Starboard steering gear pump. IAW SOLAS Ch. II-1 Reg. 29. Prior to next US port. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Coast Guard witnessed satisfactory operation of the steering gear pump.
Fire Fighting › Means of Escape › Doorways
Issued 21 April 2004
Resolved
Adjust self closing fire doors that open from engine room to steering room, that open into the galley, and on main deck that open into ladder well. IAW SOLAS CH. II-2 Reg. 46+47. Prior to next US port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Coast Guard witnessed satisfactory repairs of all firedoors
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 21 April 2004
Resolved
Replace hand rail on port Accomadation ladder. IAW ICLL Reg. 25, Proir to next US port
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Coast Guard witnessed operational satisfaction of port accomadation hand rail.
Fire Fighting › Ventilation Systems › Fans
Issued 21 April 2004
Resolved
Provide covers for fire dampers in hospital space. IAW SOLAS Ch. II-2 Reg. 16, Prior to next US port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Due to new construction there are no longer any fire dampers in the hospital.
Engineering › Sea-water System (primary cooling) › Pump
Issued 21 April 2004
Resolved
Prove to the satisfaction of class that soft patch in engine room 2nd level portt side meets adequate standards for service. IAW SOLAS CH. II-1 Reg 26, Prior to next US port LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Issue was addressed at dry dock, and there is no longer any evidence of a soft patch, witnessed by Coast Guard.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 April 2004
Resolved
Repair main engine exhaust leak in engine room upper level, where piping is black from exhuast leak. IAW SOLAS Ch. II-1 Reg. 26, Prior to next US port
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Coast Guard witnedded satisfactory operation of the MDE
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 21 April 2004
No resolution recorded
Install stud for the vapor recovery flange connections. IAW 33 CFR 154.810, Prior to next US port
Condition: Unknown
Action required: 705 - Other - as specified
Resolution: Due to the new classification of the vessel, the vessel no longer has a Vapor recovery system.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 20 April 2004
Resolved
Make permanent repairs to No. 2 cylinder of the main engine IAW SOLAS CH II-1 REG 26 to the satisfaction of Class. LEGACY COMPONENT DESC: Cylinder Liner
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2004
Resolution: Received Class report attesting to the proper operation of the No. 2 cylinder/main propulsion.
Engineering
Issued 17 April 1999
Resolved
OWS failed to operate properly when first tested.
Condition: Unknown
Due 17 April 1999
Resolved 26 April 1999
Lifesaving
Issued 8 March 1998
Resolved
STARBOARD SIDE ENCLOSED MOTOR LIFE BOAT DAVITS INOPERATIVE.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Documentation
Issued 8 March 1998
Resolved
VESSEL NOT ADHERING TO THE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 28 August 1996
Resolved
PORT AND STBD EMBARKATION LADDERS WERE WEIGHT TESTED AND FAILED TO MEET REQUIREMENTS.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Documentation
Issued 22 March 1990
Resolved
VESSELS IOPP FORM "B" DID NOT INDICATE IF VESSEL IS CERTIFIED FOR CRUDE CARRIER, PRODUCT CARRIER, OR CRUDE/PRODUCT CARRIER.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Navigation
Issued 22 March 1990
Resolved
VESSEL WAS MISSING U.S. CHART 12304 OR FOREIGN EQUIL IN SIZE AND DETAIL.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990