Records from 1990 to 2018. Most recent: inspection, 30 August 2018.
Inspection history · 35
30 August 2018
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6527056
9 August 2016
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5967282
20 July 2016
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5947843
7 July 2016
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5933709
19 April 2016
Examination of Repairs · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5859087
21 August 2014
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4961198
11 July 2012
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4375131
23 September 2010
Drydock Exam · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3855916
21 July 2008
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3295551
30 June 2008
Drydock Exam · Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3281932
27 June 2007
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2978008
21 September 2006
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2772852
6 June 2005
Re-Inspection · Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2381251
20 September 2004
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2203923
5 September 2003
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1899637
26 August 2002
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1617161
24 August 2001
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1445872
28 June 2001
Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1068691
31 August 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1382020
25 July 2000
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1361747
29 June 1999
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1427686
5 August 1998
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1445371
2 July 1996
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1390289
16 April 1996
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1445196
13 July 1995
Re-Inspection · Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1427086
8 July 1994
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1464534
23 September 1993
Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1154942
28 August 1993
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 214543
20 July 1993
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1446001
17 July 1992
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1261179
26 June 1992
Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1267342
10 June 1992
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1267498
19 June 1991
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1203962
20 July 1990
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907529
12 January 1990
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 912117
Lifesaving › Buoyant Apparatus › Serviceable
Issued 7 July 2016
Resolved
Make permanent repairs to body of buoyant apparatus or renew with appropriate sized IBA.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 9 August 2016
Resolution: Repairs completed to body of buoy.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 July 2016
Resolved
Properly mount midship space high bilge level alarm.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 9 August 2016
Resolution: High bilge level alarm affixed to frame.
Construction/Loadline › Hull › Stringer
Issued 7 July 2016
Resolved
Make permanent repairs to fracture within longitudinal stringer just aft of insert in midship compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 20 July 2016
Resolution: Attended vessel on the trailer at Purvis and Foster, Detroit, MI and examined a weld fracture that had been satisfactorily repaired.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 7 July 2016
Resolved
Make MSD useable by function test after installation of lines which were removed prior to welding within the midship compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 9 August 2016
Resolution: MSD properly piped in.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 July 2016
Resolved
Make permanent repairs to through hull fitting/leaking within the midship compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 9 August 2016
Resolution: Valve renewed and reinstalled. Operated properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 July 2016
Resolved
Remove "wing" type nuts from battery terminals and install permanent type connectors.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 9 August 2016
Resolution: Nylock type nuts installed on battery terminals.
Construction/Loadline › Structures › Scuttle
Issued 7 July 2016
Resolved
Install/replace screw type handle/dog closure device on forward emergency escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 9 August 2016
Resolution: Dog handle installed on port side securing bolt of emergency escape.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 July 2016
No resolution recorded
Provide Radio, Ops permit, and GLA.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Valve
Issued 7 July 2016
Resolved
Make permanent repairs to fuel shutoff for port main engine. Inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 9 August 2016
Resolution: Fuel shutoff lubricated. Exercised at time of inspection and operated properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 July 2016
Resolved
Make permanent repairs to shutdown on starboard main engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 9 August 2016
Resolution: Starboard main engine CO2 system shutdown functioned properly during removal of canon plug.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 July 2016
Resolved
Mark stowage locations to include adult/child and numbers at each location.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 9 August 2016
Resolution: Stowage locations sighted.
Communications › Radio Communications › EPIRB
Issued 7 July 2016
No resolution recorded
Install approved 406 Cat I prior to ops beyond 3NM.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 July 2016 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2016
Resolved
Update first aid kit to comply with current expiration dates and 160.041 list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 9 August 2016
Resolution: All items within first aid kit updated satisfactorily.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 July 2016
No resolution recorded
Provide FCC type approved radar.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016 — due date passed with no resolution recorded
Navigation › Piloting/Steering › Marine Charts
Issued 7 July 2016
No resolution recorded
Provide charts and all nautical pubs for route and area of operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 7 July 2016
No resolution recorded
Provide DAPI program compliance per 46CFR16
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2016
Resolved
Provide cover plate for aft passenger compartment lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 9 August 2016
Resolution: Cover plate installed over lighting fixture.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 July 2012
Resolved
Fire Suppression System Visual Alarm indicator light inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2012
Resolution: Visual alarm/system operation indicator verified operational.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 July 2012
Resolved
Owner not enrolled in a consortium. Owner to provide documentation attesting to enrollment under the DAPI program to satisfy requirement for pre-employment drug testing and enrollment in a random drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2012
Resolution: Owner provided proof of enrollment within a DAPI program and completion of pre-employment testing.
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 July 2012
Resolved
Remote Fuel shut off valves inoperable. Port and Starboard remote fuel shut off valves require repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2012
Resolution: Fuel shut-offs repaired. Witnessed operation of valves.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 11 July 2012
Resolved
Aft Buoyant Apparatus (BA) float light inoperable. Owner to renew/repair as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2012
Resolution: Witnessed float light operation. Batteries replaced.
Communications › Radio Communications › EPIRB
Issued 11 July 2012
Resolved
Provide proof of EPIRB registration with NOAA.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2012
Resolution: Epirb registration verified.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 July 2012
Resolved
Operator to obtain Marine Radio Operators Permit
Action required: 705 - Other - as specified
Due 15 September 2012
Resolved 8 July 2016
Resolution: Sighted permit.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 July 2012
Resolved
Lifebuoy needs to have ship name affixed to the buoy along with the approriate life line and light.
Action required: 705 - Other - as specified
Due 15 September 2012
Resolved 17 August 2012
Resolution: Vessel name and retroflective tape noted along with proper attachment of light line.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 July 2012
Resolved
Fore and Aft Buoyant Apparatus have surface cracks. Make appropriate repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2012
Resolved 7 July 2016
Resolution: Item updated on later inspection activity.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 11 July 2012
Resolved
Fore Buoyant Apparatus (BA) weak link rated capacity tag missing. Renew weak link or re-install missing tag.
Action required: 705 - Other - as specified
Due 15 September 2012
Resolved 6 September 2012
Resolution: Owner provided photo of new weak link. Photo in unit e file.
Stability › Weathertight Integrity › General
Issued 11 July 2012
Resolved
Renew Damaged Port Window.
Action required: 705 - Other - as specified
Due 15 September 2012
Resolved 8 July 2016
Resolution: Item updated on later inspection activity.
Communications › Radio Communications › EPIRB
Issued 23 September 2010
Resolved
Hydrostatic release expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2010
Resolution: New hydrostatic release installed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 September 2010
Resolved
System not wired to automatically shut down engines as required by 46 CFR 181.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2010
Resolution: Owner demonstrated engines shut down if clean agent extinguishers activated.
Construction/Loadline › Hull › Hull Plating
Issued 23 September 2010
Resolved
Noted fractures in bottom plating, starboard side, forward. Fractures had been marked by an indelible ink pen that did not appear recent, indicating owner/operators had knowledge of fractures and still operated.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 October 2010
Resolution: Fractures had been repaired by drill stop, vee(d) and welded.
Construction/Loadline › Hull › Keel
Issued 30 June 2008
Resolved
12" fracture located stbd side forepeak IWO of CVK weld.
Action required: 705 - Other - as specified
Resolved 7 July 2008
Resolution: Fracture has been ground out and welded, sat
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 21 September 2006
Resolved
Provide documentation that 50% of crew is First Aid/CPR certified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Documentation provided.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 21 September 2006
Resolved
Replace Halon bottle pull cords for discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Replaced
Lifesaving › Hand Flares › Not on Board
Issued 21 September 2006
Resolved
Provide 3 hand held flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Provided
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 21 September 2006
Resolved
Prove proper operation of gas vapor detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Vapor detection system works.
Lifesaving › Lifefloat › Markings
Issued 21 September 2006
Resolved
Properly mark lifefloats with max person capacity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Properly marked
Lifesaving › Lifefloat › Lifeline
Issued 21 September 2006
Resolved
Provide 100' UV protected life line with weak link fo both lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2007
Resolution: Life line was installed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 September 2006
Resolved
Provide SOLAS approved retroreflective tape to lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Completed.
Navigation › Piloting/Steering › Marine Charts
Issued 21 September 2006
Resolved
Provide new navigation chart on vessel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: New chart is on vessel
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 September 2006
Resolved
Properly fasten all loose wires and provide a means to run them so they are not lying along the bottom longitudinals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Wires are out of bilges.
Stability › Watertight Integrity › General
Issued 21 September 2006
Resolved
Install double clamping on all hoses 6" above water line and below.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Completed
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 21 September 2006
Resolved
Repair 1/4" fracture on aft ladder bottom rung IWO STBD hand rail.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: Fracture has been welded.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 September 2004
Resolved
Vessel is not to carry passengers prior to completing a thorough Inspection and completion of drills
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 10 August 2007
Resolution: Inspection and Drills complete.
Lifesaving › Lifebuoys › Stowage
Issued 5 September 2003
Resolved
PROPERLY ATTACH 3-FOOT LANYARD AND CORROSION RESISTANT CLIP TO RING BUOY LIGHT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 27 June 2007
Resolution: 3 foot lanyard attached.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 September 2003
Resolved
[name withheld] AND ABANDONSHIP DRILLS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 10 August 2007
Resolution: Underway drills were conducted.
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2003
Resolved
POST GREAT LAKES AGREEMENT FCC SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 27 June 2007
Resolution: Great Lakes agreement posted
Documentation › Markings/Placards › Capacity Marking
Issued 5 September 2003
Resolved
PROPERLY MARK "18 ADULT / 4 CHILDREN LIFEJACKETS" AT STOWAGE LOCATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 27 June 2007
Resolution: Completed
Lifesaving › Visual Distress Signals (General)
Issued 15 May 2002
Resolved
Provide four signal devices for full complement required LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2002
Resolved 26 August 2002
Lifesaving
Issued 24 August 2001
Resolved
Renew hydrostaic release for EPIRB.
Condition: Unknown
Due 24 December 2001
Resolved 26 August 2002
Lifesaving
Issued 24 August 2001
Resolved
Provide waterlight, weak link, and painter for 6 person life float.
Condition: Unknown
Due 24 December 2001
Resolved 26 August 2002
Engineering
Issued 24 August 2001
Resolved
Prove proper operation of gas vapor detection system.
Condition: Unknown
Due 24 December 2001
Resolved 26 August 2002
Lifesaving
Issued 24 August 2001
Resolved
Complete fire and man overboard drills.
Condition: Unknown
Due 24 December 2001
Resolved 26 August 2002
Lifesaving
Issued 31 August 2000
Resolved
Provide & post lifejacket donning instructions IAW 46 CFR 185.516
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Electrical
Issued 31 August 2000
Resolved
Provide two operable portable battery lights IAW 46 CFR 183.430
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Documentation
Issued 31 August 2000
Resolved
Post Certificate of Inspection & Stability Letter IAW 46 CFR 176.302 & 176.306.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Provide flammable vapor detection system as required by 46 CFR 182.115(c) for machinery powered by gasoline. System must be installed IAW 46 CFR 182.480.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Navigation
Issued 31 August 2000
Resolved
Provide efficient sound producing device IAW 33 CFR 86.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Provide two paddles & one approved water light for lifefloat, mark paddles with vsls name. Remove plastic wire ties from lifefloat pendants & replace with suitable break away material. Must be completed prior to carriage of passengers for hire.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Provide existing ring life buoy with approved waterlight, lanyard and at least 60 feet of line.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Engineering
Issued 31 August 2000
Resolved
Mount ventilation ducting in engine space above level of bilge pump suctionto keep ducting from being under water.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Provide crew training & document training.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Documentation
Issued 31 August 2000
Resolved
Provide proof that master is enrolled in Owners drug program consortium andthat program is in compliance with federal regulations.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Renew retroreflective tape on lifefloat.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Fire Fighting
Issued 31 August 2000
Resolved
Document crew firefighting training and drills.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Post emergency instructions at operating station IAW 46 CFR 185.512
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Navigation
Issued 31 August 2000
Resolved
Raise mounting bracket on all around white light so that it will not be obscured by vsl radar dome.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Navigation
Issued 31 August 2000
Resolved
Repair/replace all around white light
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Provide IAW 180.68, six hand orange smoke distress signals or an approved substitution.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 31 August 2000
Resolved
Document or log EPIRB test requirements IAW 46 CFR 185.728
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Accommodation/Occupational Safety
Issued 31 August 2000
Resolved
Provide missing dive deck safety chain IWO vsl boarding ladder
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Documentation
Issued 25 July 2000
Resolved
Provide a current FCC Placard.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Documentation
Issued 25 July 2000
Resolved
_x001C_ stencil "Emergency Escape IWO forward hatch._x001C_
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Construction/Loadline
Issued 25 July 2000
Resolved
Provide proper repair IWO Stem weld to keel, this repair is required to correct a manufactures Deficiancey._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Accommodation/Occupational Safety
Issued 25 July 2000
Resolved
Relocate anchor line pass-through IWO collision bulkhead.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000