MAURY USCG vessel records Sign in
← All vessels

WHITNEY BAY

WHITNEY BAY is a 1990 freight ship. The Coast Guard has recorded 59 inspections since 1990, most recently in October 2024, along with 29 deficiencies and 17 operational controls.

Records from 1990 to 2024. Most recent: inspection, 8 October 2024.

Built
1990
Last inspected
8 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8911085 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
345804
Flag
LIBERIA
—
Maury page id
psix-345804

Inspections, by type

…with no type recorded24
Years with a record 26 calendar years (1990–2024)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it4085 - Convention (Subpart B), Net Ton
14415 - Displacement, Ton
9487 - Dead Weight, Ton
8739 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 59

8 October 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8015900
2 January 2024 PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7844197
23 January 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7622383
19 January 2023 Ballast Water Examination · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7623972
11 October 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7574292
10 May 2022 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7447830
24 April 2022 PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7435487
18 March 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7413359
14 March 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7411413
24 October 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7339252
19 October 2021 COE-Offshore · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7335491
1 March 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7147872
10 September 2020 COE-Administrative · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7054919
6 March 2020 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6921974
2 January 2020 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6878366
16 December 2019 COE-Administrative · PII Safety Exam · Ballast Water Examination · ISPS II Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6874664
10 July 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6744604
10 July 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6744964
29 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6651812
22 March 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6647160
14 March 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6642571
12 June 2018 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6441890
10 June 2018 COE-Offshore
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6434691
10 June 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6436741
6 February 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6350761
5 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6349650
2 February 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6348717
20 November 2017 Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6310819
18 November 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6309052
15 December 2016 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6058488
21 September 2016 Ballast Water Examination · COE-Offshore · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6005762
19 September 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6004692
16 December 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5782696
27 December 2010 Ballast Water Examination · ISPS III Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3916422
8 October 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3865917
17 December 2009 PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3652025
7 July 2008 PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3254389
4 July 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3256693
18 October 2006 Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2802993
4 April 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2616543
10 December 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2549267
9 December 2005 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2548324
6 December 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2546659
21 January 2005 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2278777
24 November 2004 ISPS II Exam · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2247626
10 March 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2021878
23 October 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1935024
19 December 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1720928
18 December 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1720677
2 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 287688
23 May 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 278020
17 December 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 435752
27 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 368426
30 December 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 363399
7 December 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486905
4 February 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 458420
12 December 1991 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 347658
5 April 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 342954
20 March 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 335943

Deficiency record · 29

08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 8 October 2024 Resolved
An alarm system shall be provided indicating any fault requiring attention. Port aft bilge alarm in the engine room was missing. Crew member installed new bilge alarm and tested satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2024
Resolved 8 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 January 2024 Resolved
07105- Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. A-60 door leading from engine space into an accommodation space was found with a loose door frame. Door frame welds were found broken allowing light and air to pass through the frame. 17ac/74SOLAS(97)II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2024
Resolved 10 January 2024
Resolution: Class conducted inspection. Door was welded and a light test was conducted.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 9 January 2024 Resolved
14104- Oil filtering equipment shall be design approved by the administration. Oil filtration equipment was found to have a pressurized leak. The leak produced approximately 1 gallon every 10 minutes when turned on. 17ac MARPOL I/14.6
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2024
Resolved 10 January 2024
Resolution: Class conducted inspection. Pipe was refitted.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 January 2023 Resolved
07105 - Fire Doors - Doors required to be self-closing shall not be fitted with hold-back hooks. Observed 04 fire doors with hold-back hooks installed. 74 SOLAS 97 II-2 / 47.2
Action required: 10 - Deficiency Rectified
Resolved 19 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 January 2023 Resolved
07105 - Fire Doors - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. AC room door was not capable of self-closing. 74 SOLAS 97 II-2 / 47.1
Action required: 10 - Deficiency Rectified
Resolved 19 January 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2022 Resolved
09209 - Electrical- Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCOs witnessed missing latching, secure pin, and cover in light distribution board in BOSUN locker. SOLAS 74 (97 Cons) II-I/40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2022 Resolved
09209 - Electrical- Cables and wiring shall be installed and supported in such manner as to avoid chafing or other damage. PSCOs witnessed broken wiring support bracket at BOSUN locker entrance. 74 SOLAS (97 Cons) II-I/ 45.5.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 October 2021 Resolved
The steering gear compartments shall be: provided with suitable arrangements to ensure woring access to steering gear machinery and controls. These arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. PSCE observed an absence of gratings or non-slip surface in the steering gear room.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 October 2021
Resolved 14 March 2022
Resolution: RECEIVED SATISFACTORY EVIDENCE THAT THE DEFICIENCY HAS BEEN RECTIFIED TO BE IN COMPLIANCE WITH THE REQUIREMENTS OF THE CONVENTION.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 December 2019 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO's observed port side lifeboat engine shutting off immediately after starting. PSCO's observed several attempts with no satisfactory result.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2019
Resolved 22 December 2019
Resolution: WHITNEY BAY submitted class survey report certifying proper repair and function of their lifeboat
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 March 2019 Resolved
Survival craft embarkation arrangements shall be so designed that lifeboats can be boarded and launched directly from the stowed position. Sheave that holds self launching cable in position broke free from support arm. Vessel is unable to launch starboard lifeboat from inside the craft.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2019
Resolved 28 March 2019
Resolution: Defective parts were replaced. see attached class report.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 20 November 2017 Resolved
The davit armwere moving in an uneven manner, leading to the falls Binding and catching
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2017
Resolved 21 November 2017
Resolution: Class Report : Ships crew found fall wire out of position. Crew readjusted the stopper and put in proper position.
Fire Fighting › Firemans Outfit › Gloves
Issued 20 November 2017 Resolved
THE GLOVES AND HOODS FOR THE FIREMAN'S OUTFITS ARE DETERIORATED
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 November 2017
Resolved 21 November 2017
Resolution: Class Report: Company has provided for new replacements of all needed worn FFE gloves and hoods.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 September 2016 Resolved
0715-Detection-Maintenance, testing and inspections shall be carried out based on guidelines developed by the organization. Vessels crew is testing heat detectors on board with open flame causing damage to the fire detection system. Vessel does not have proper equipment on board to test the heat detectors.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 15 December 2016
Resolution: Vesel emailed in Class report and documentation pertaining to vessel having equipment to safely test fixed smoke detection system.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 27 December 2010 Resolved
1510 - Navigation Equipment - Vessel required to have an operating Gyro repeater, PSCO noted that the Gyro repeater on the bridge was indicating a difference of 10* variance from master Gyro. Site: 33CFR164.35(c). Action taken: 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2010
Resolution: Class submitted survey report attesting that the gyro compass and repeaters are fully functional.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 8 October 2010 Resolved
0830 - Accident Prevention, Machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service, and shall be so installed and protected to reduce minimum dangers to persons onboard. Cylinder #4 fuel oil steam heating steam pipe is broken and emitting steam. Solas 74(04) II-1r reg 26, 70(a)
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 28 December 2010
Resolution: Sector Delaware Bay received class report from NKK attesting to the tightening of the joint, and the line is in good working order with no leaking steam noted.
Electrical › Electric Supply System (service) › Cable
Issued 8 October 2010 Resolved
0950-Safety General, Electrical cables and wiring external to equipment shall be at least of a flame retardant and so installed as not to impair the original flame retardant properties. Wire run inside mooring deck door leading to the steering gear compartment is severely wasted, all electrical cable shielding is rusted away. Solas74(04) ChII-I Reg 45 5.2 70(a)
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 28 December 2010
Resolution: Sector Delaware Bay received class report from NKK attesting to the insulation of all wire runs, noting that they are all in satisfactory condition.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 8 October 2010 Resolved
2100-Marpol, No significant change shall be made in the equipment, fittings, arrangements without the approval of the administration. Sewage treatment tank has epoxy repairs to the tank plating. Discharge piping has been modified to go overboard and piping has been removed.MARPOL 73/78 (2006) ANNEX VI/Reg 3.4 (70a)
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 28 December 2010
Resolution: Sector Delaware Bay received class report from NKK attesting to the addition of a plate to replace the epoxy repairs. Discharge piping has been restored to original piping arrangement.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 8 October 2010 Resolved
1430-Propulsion Aux Machinery, Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. Emergency Diesel generator engine fuel injector supply lines leak during engine operation. Solas74(04) Ch II-2 Reg 4 2.2.5.4 70(a)
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 28 December 2010
Resolution: Sector Delaware Bay received class report from NKK attesting to the repairs made to the copper gaskets, and no further leakage has been confirmed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 October 2010 Resolved
1530-Radar, A 3 GHz radar or where considered appropriate by the Administration, a second 9 GHz radar, or other means, to determine and display range and bearing of other surface craft. . . Vessel's port radar was inoperative on inbound transit, radar condition was not identified on NOA and the COTP was not notified.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2010
Resolved 14 October 2010
Resolution: Radar technician arrived onboard during exam. Radar motor brushes were replaced on the radar motor.
Engineering › Fuel Oil Service System › Pump
Issued 17 December 2009 Resolved
1410 propulsion main engine- Pressure vessels and fittings shall be of a design adequate for the service for which they were intended. During the engine room inspection it was noted that the number one fuel pump was leaking excessively. VSL is to make permanent repairs and have class attest to the condition of all fuel pumps prior to departure from port. SOLAS 2004 cons. ed., CH II-I/REG 26.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2009
Resolved 18 December 2009
Resolution: Ships engineers replace various parts and corrected the leaking #1 M/E fuel pump. Class has submitted a report attesting to the proper repairs. Report has been scanned into this activity.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 6 December 2005 Resolved
Vessels Incinerator was inoperable. Crew could not fire the same. Vessel is in violation of 33CFR151.19(e)(1). Rectify deficiency prior to next U.S port to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 13 December 2005
Resolved 4 April 2006
Resolution: Recieved class report attesting the proper operation of the incinerator.
Engineering › Steam Boiler (auxiliary/waste heat) › Inner Casing
Issued 6 December 2005 Resolved
Vessels boiler housing is seperated. Allowing exhaust gas into the engine room. Vessel is in violation of SOLAS 2004 Chapter II-1 Regulation 26 1. Rectify deficiencies within 30 days to the satisfaction of class.
Condition: Unknown
Due 6 January 2006
Resolved 4 April 2006
Resolution: Recieved class report attesting to the proper repair of the boiler housing.
Electrical › Lighting (service)
Issued 10 March 2004 Resolved
LIGHTING WITHIN THE EMERGENCY ESCAPE TRUNK FROM THE ENGINE ROOM TO THE MAIN DECK WAS FOUND INOPERATIVE (SOLAS 74 CHAPTER III PART B REG 11.5) LEGACY COMPONENT DESC: ESCAPE TRUNK LIGHTING
Condition: Improper/Lack of Maintenance
Due 10 March 2004
Resolved 10 March 2004
Resolution: CORRECTED ON THE SPOT.
Deck/Cargo › Cargo Stowage › General
Issued 10 March 2004 Resolved
HYDRAULIC OIL LEAKING FROM THE RAM ON THE PORT SIDE OF CARGO HATCH #2 (SOLAS 74 CHAPTER I REG 11(a)). AS PER NKK CLASS REPOR, DATED 10MAR04, VSL WAS GIVEN 'TIL 31JUL04, WHEN NEXT DRYDOCKING IS SCHEDULED, TO HAVE REPAIRED. LEGACY COMPONENT DESC: CARGO HATCH #2 HYDRAULIC RAM
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 29 November 2004
Resolution: Recieved class report attesting to repair.
Navigation
Issued 17 December 1999 Resolved
VESSEL'S ECHO DEPTH SOUNDER WAS INOPERATIVE DURING INBOUND TRANSIT
Condition: Unknown
Due 17 December 1999
Resolved 24 December 1999
Engineering
Issued 17 December 1999 Resolved
IAW 33 CFR 155.820, BUNKER LINES MUST BE PRESSURE TESTED TO 1 1/2 TIMES THEIR MAXIMUM ALLOWABLE WORKING PRESSURE._x001C_ ****VESSEL MUST TEST BUNKER LINES BEFORE BEING ALLOWED TO BUNKER IN U. S. WATERWAYS****
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Accommodation/Occupational Safety
Issued 17 December 1999 Resolved
TOILET IN HOSPITAL SPACE IS INOPERATIVE IN VIOLATION OF STANDARDS SET FORTHWITHIN ILO-147.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Navigation
Issued 20 March 1990 Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART 12304 OR IT'S ACCEPTABLE FOREIGN EQUIVALENT WHICH WAS REQ. FOR THE VSL'S TRANSIT FROM CAPE HENLOPEN DE. TO ARNOLD'S POINT N.J.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Navigation
Issued 20 March 1990 Resolved
A VIO OF SOLAS 191 IN THAT THE VSL FAILED IT'S EMERGENCY STEERING GEAR TEST
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.