MAURY USCG vessel records Sign in
← All vessels

LIBRA

LIBRA is a 1988 tank ship. The Coast Guard has recorded 27 inspections since 1990, most recently in August 2006, along with 11 deficiencies and 3 operational controls.

Records from 1990 to 2006. Most recent: inspection, 5 August 2006.

Built
1988
Last inspected
5 August 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8700412 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
345973
Flag
SINGAPORE
—
Maury page id
psix-345973

Inspections, by type

…with no type recorded12
Years with a record 10 calendar years (1990–2006)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23926 - Simplified, Gross Ton
23926 - Convention (Subpart B), Gross Ton
48422 - Displacement, Ton
40141 - Dead Weight, Ton
11582 - Convention (Subpart B), Net Ton
11582 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

5 August 2006 COC-TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2736545
2 September 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2481944
14 May 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2357585
18 April 2005 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2336829
2 April 2005 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2323631
13 August 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1879728
1 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1784781
23 April 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1779235
28 March 2003 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1764492
14 September 2002 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1676164
25 May 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1618469
18 February 2002 Certificate of Compliance · Deficiency Check · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1487733
28 January 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 286570
28 January 2001 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395619
11 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 22159
11 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 431678
11 August 1999 Tank Vessel Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 776864
23 October 1993 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1157423
15 August 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 14376
14 August 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 465861
10 August 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 843056
18 May 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 830934
25 October 1992 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 950075
23 March 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 342786
23 March 1991 Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305550
23 March 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 335987
23 March 1990 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1290695

Deficiency record · 11

Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 April 2005 Resolved
Three of the four flange connections for the Vapor Control System were missing studs. Provide a permanently attched stud for each vapor connection flange that meets the requirements of 46 CFR 39.20-1(e) prior to next U.S. Port.
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2005
Resolved 17 April 2005
Resolution: Permanent studs installed.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 April 2005 Resolved
One of the four fireman's outfits onboard was badly deteriorated and in an unsatisfactory condition. Provide a complete fireman's outfit that meets the requirements of SOLAS 74 Amended, Chapter II-2, regulation 17 prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2005
Resolved 4 April 2005
Resolution: A complete fireman''s outfit, SOLAS approved, was received by the vessel.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 April 2005 Resolved
There were no 2005 Tide Tables on board the vessel during the time of inspection for the area transited. Provide 2005 Tide Tables that meet the requirements of 33 CFR 164.33(a)(3)(i) prior to departure from port. Due to the unavailability of the Tide Tables, vessel was permitted to sail and Tide Tables must be provided by Next U.S. Port.
Action required: 15 - Rectify deficiencies by next port
Due 4 April 2005
Resolved 4 April 2005
Resolution: Vessel received 2005 Tide Tables prior to departure.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 April 2005 Resolved
Vessel did not have 2005 Tidal Current Tables onboard for the area transited during the time of inspection. Provide 2005 Tidal Current Tables for the area transited that meet the requirements of 33 CFR 164.33(a)(3)(ii) prior to departure from port. Due to the unavailability of the Tidal Current Tables, vessel was permitted to sail and Tidal Current Tables must be provided by Next U.S. Port.
Action required: 15 - Rectify deficiencies by next port
Due 4 April 2005
Resolved 4 April 2005
Resolution: Vessel received 2005 Tidal Current Table prior to departure.
Deck/Cargo › Vapor Control Systems
Issued 18 February 2002 Resolved
Vessel has VCS installed w/no Letter of Approval from Class, high/ low vapor pressure alarms unable to be tested, & vapor line improperly labeled: 46CFR39.10-1, .20-13, .20-1(d)(2); Provide Class ltr, proper marking, and test high/low pressure alarms prior to loading cargoes requiring VCS.
Action required: 705 - Other - as specified
Resolved 25 May 2002
Resolution: VCS Letter of Approval from Class was inspected, vapor line properly labeled and proof of vapor line highl/low pressure alarms properly tested. This deficiency cleared.
Pollution Prevention/Response › Prevention Equipment
Issued 18 February 2002 Resolved
Overfill alarm: (on deck)-improperly labeled and not visual/ (in cargo control room)-no audio alarm; 33CFR155.480(a)(1); (on deck)- Provide label "OVERFILL ALARM" and visual alarm indicator/ (in cargo control room)- Provide audio alarm prior to conducting cargo operations. LEGACY COMPONENT DESC: Overfill Devices
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 25 May 2002
Resolution: Observered properly labeled over-fill alarm on deck and CCR. Tested audio visual alarm indicator all satisfactory.
Construction/Loadline › Structures
Issued 18 February 2002 Resolved
No safe bow access; SOLAS 74Am(96Am)II-1/3-3; Class to address and provide report to USCG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2002
Resolved 19 February 2002
Resolution: Rcvd Class Report which identified that Flag State (Greece) and Class(NKK) extended requirmement for vessel to install safe bow access until 15Dec2002.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 18 February 2002 Resolved
Excessive corrosion at bottom of deck water seal; SOLAS 74Am I/11; Class to address and provide report to USCG prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2002
Resolved 19 February 2002
Resolution: Rcvd Class report addressing corrosion. Class issued report citing that Deck water seal was acceptable and made a recommendation for Deck water seal to be closely examined at each periodical survey.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 18 February 2002 Resolved
Approx 1 cm hole in Foam Fire Main line located on main deck adjacent to Deck Water Seal; SOLAS 74Am I/11; Provide temporary repair and Class to address when permanent repair will be made, prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2002
Resolved 19 February 2002
Resolution: Rcvd Class report citing that proper temp repair was made to foam fire main. Class report cited that permanent repair must be made NLT 18Apr2002.
Pollution Prevention/Response › Prevention Equipment
Issued 18 February 2002 Resolved
Emergency Lightering equipment (Two complete sets of 6", 8", 10' Reducers, adapters, bolts, washers, nuts, gaskets) not stowed in a weather protected, marked location; 33CFR157.410; Provide emergency lightering equipment IAW referenced regulation NLT 4Mar2002.
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 25 May 2002
Resolution: Emergency lightering equipment stowed in proper protected and marked location. This deficiency cleared.
Deck/Cargo
Issued 25 October 1992 Resolved
DUE TO EMPTY CARGO SYSTEMS, EMERGENCY STOPS FOR THE CARGO PUMPS WERE NOT TESTED. TEST CARGO PUMP EMERGENCY STOPS PRIOR TO DISCHARGE OF CARGO AT NEXTU.S. PORT WITNESSED BY USCG INSPECTOR.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.